Guarded Hot Plate Thermal Conductivity Tester

Guarded Hot Plate Thermal Conductivity Tester

Skip to product information
Guarded Hot Plate Thermal Conductivity Tester
SKU:

Guarded Hot Plate Thermal Conductivity Tester

Get personalized pricing for your specific requirements

Guarded Hot Plate Thermal Conductivity Tester – QualiGTX™ GHP

Guarded Hot Plate Apparatus for Insulation Boards and Mortars, 300 × 300 mm Specimen

The QualiGTX™ GHP Guarded Hot Plate Thermal Conductivity Tester determines the thermal conductivity (lambda value) of insulation materials using the steady-state guarded hot plate method. It covers a measurement range of 0.010 to 3.000 W/(m·K) and accommodates specimens measuring 300 × 300 mm. These measurements establish whether insulation materials satisfy specified thermal performance requirements for building applications. As a primary reference method, the guarded hot plate also provides the benchmark for calibrating comparative thermal conductivity instruments. The system delivers measurement accuracy within 2% and repeatability below 1%.

Designed for foam concrete, insulation mortars, and other comparable cast or molded materials, the apparatus tests specimens prepared using a corresponding 300 × 300 mm mold. Its automated loading and unloading system maintains consistent clamping pressure throughout testing. This is particularly important when evaluating rigid materials, where variations in specimen surface flatness and contact resistance at the plate interfaces can introduce measurement errors. Applying uniform pressure helps maintain consistent thermal contact conditions and improves repeatability between successive tests.

The temperature controls provide flexibility for testing under specified conditions, with the cold plate adjustable from 5 to 50 °C and the hot plate adjustable from ambient temperature to 80 °C. This allows laboratories to establish the required mean test temperature rather than relying on fixed operating conditions. The apparatus accepts specimens from 10 to 45 mm thick, with 25 mm identified as the preferred thickness. It operates on a single-phase power supply with a consumption of 2 kW. The equipment weighs 215 kg and measures 1600 mm in height, with a footprint of 800 × 600 mm. The specified operating environment is 10 to 40 °C, and installation in an air-conditioned laboratory is recommended.

Guarded Hot Plate Thermal Conductivity Tester – QualiGTX™ GHP Applications

Accurate thermal conductivity measurements support material selection, insulation performance assessment, building energy calculations, and the development of new construction products. The QualiGTX™ GHP provides laboratories and manufacturers with a primary-method solution for evaluating heat transfer through insulation and cement-based materials.

  • Foam Concrete Manufacturing and Quality Control: Monitors thermal conductivity across production batches to identify changes associated with variations in mix density, foaming agent concentration, and curing conditions. This helps manufacturers maintain consistent insulation performance throughout production.
  • Insulation Mortars and Thermal Render Evaluation: Measures the thermal properties of insulating plasters and render formulations intended for application to masonry and concrete surfaces, supporting material qualification and product performance assessment.
  • External Wall Insulation Systems: Establishes thermal conductivity values for insulation materials used in external wall assemblies. These measurements provide essential input for calculating the thermal performance of complete wall systems.
  • Rigid Insulation Board Assessment: Evaluates the thermal conductivity of rigid insulation boards and panels within the supported thickness range, providing measurement data for manufacturing quality checks and product acceptance.
  • Building Energy Performance and Code Requirements: Determines declared lambda values used in thermal transmittance (U-value) calculations, supporting building energy assessments and regulatory documentation.
  • Lightweight and Aerated Concrete Research: Helps researchers and manufacturers compare different concrete formulations during product development, particularly when reducing heat transfer is a key material design objective.
  • Pavement and Subgrade Insulation Evaluation: Characterizes the thermal properties of insulating layers incorporated into road structures to limit frost penetration and support pavement construction requirements.
  • Independent Construction Materials Testing Laboratories: Provides guarded hot plate measurement data for third-party testing, material certification, and product approval services where recognized primary-method results are required.
  • Porous and Cellular Material Research: Supports investigations into the relationship between pore structure, material density, moisture content, and heat transfer behavior in porous and cellular materials.

Standards

The QualiGTX™ GHP is designed around the internationally recognized guarded hot plate procedure for determining steady-state thermal resistance and associated thermal properties of insulation materials.

  • ISO 8302 – Thermal Insulation: Determination of Steady-State Thermal Resistance and Related Properties, Guarded Hot Plate Apparatus.

Guarded Hot Plate Thermal Conductivity Tester – QualiGTX™ GHP Key Features

The QualiGTX™ GHP integrates a guarded heating plate arrangement, automated specimen handling, and independently adjustable hot- and cold-side temperatures to support controlled steady-state thermal conductivity testing.

  • Primary Guarded Hot Plate Method: Uses a separately controlled guard surrounding the central measuring area to minimize lateral heat transfer physically. This arrangement establishes the reference conditions required for primary-method thermal conductivity measurements.
  • 300 × 300 mm Specimen Dimensions: Accommodates specimens prepared with a matching casting mold, allowing foam concrete and insulation mortar samples to be molded directly to the required test dimensions instead of being cut afterward.
  • Automated Specimen Handling and Consistent Clamping: Automates specimen loading and unloading while maintaining uniform pressure across the test surface. Consistent plate contact helps control interface resistance and reduces variations between measurements.
  • Wide Thermal Conductivity Range: Measures values from 0.010 to 3.000 W/(m·K), covering materials ranging from high-performance insulation products to denser cement-based construction materials.
  • 10 to 45 mm Specimen Thickness: Supports a range of standard cast and board-type specimen thicknesses, with 25 mm recommended as the preferred testing dimension.
  • Adjustable Cold Plate Temperature: Provides cold-side temperature settings from 5 to 50 °C, allowing laboratories to establish the required boundary conditions for measurements at specified mean temperatures.
  • Adjustable Hot Plate Temperature: Operates from ambient temperature to 80 °C, supporting tests that require elevated mean temperatures above normal laboratory conditions.
  • Measurement Accuracy Within 2% and Repeatability Below 1%: Provides the measurement consistency needed for determining declared thermal conductivity values and preparing product certification or approval documentation.
  • Single-Phase 2 kW Power Requirement: Operates from a single-phase electrical supply while accommodating the equipment's heating and cooling requirements, without requiring a three-phase connection.
  • Rigid 215 kg Construction: The substantial equipment frame provides mechanical stability and helps maintain plate alignment, supporting consistent contact conditions across the specimen.

Theory and Method

The guarded hot plate method determines thermal conductivity by measuring the heat passing through a material under stable temperature conditions. A specimen with known thickness and surface area is placed between heated and cooled plates. Once steady-state conditions are established, the apparatus measures the heat flow through the specimen and the temperature difference between its two faces. These values, together with the specimen dimensions, are used to calculate thermal conductivity. Although the calculation itself is straightforward, obtaining an accurate result depends on ensuring that the measured heat travels through the specimen rather than escaping through surrounding areas.

This is the central problem addressed by the guarded plate arrangement. Heat generated by a conventional heater naturally spreads in multiple directions. Some of this energy can travel sideways instead of passing through the designated measuring area. If this lateral heat loss is included in the measurement, the calculated thermal conductivity becomes higher than the actual value. The resulting error is particularly significant for highly insulating materials, where accurate heat flow measurement is essential.

To control this effect, the guarded hot plate places a separately powered guard ring around the central metered heating section. Both sections are maintained at the same temperature, eliminating the temperature gradient that would otherwise drive heat sideways between them. With lateral heat transfer suppressed, the energy supplied to the central measuring section passes through the specimen rather than escaping around its edges. This physical control of heat flow is what establishes the guarded hot plate as an absolute reference method. Heat flow meter instruments are consequently calibrated against measurements obtained using this technique.

Specimen thickness also influences measurement quality because it affects both temperature development and heat loss. With a thin specimen, the temperature difference across the material is relatively small, making the thermal resistance at the plate-to-specimen interfaces a more significant part of the overall measurement. Increasing specimen thickness produces a larger temperature difference, but also increases the potential for heat loss through exposed edges and extends the time needed to reach steady-state conditions.

A thickness of 25 mm provides a practical balance between these competing factors for most insulation materials. This explains why it is the preferred specimen dimension within the apparatus's supported range of 10 to 45 mm.

Laboratory temperature stability is equally important for reliable measurements. The guard system uses a control loop to maintain the temperature balance between the central measuring plate and the surrounding guard, while operating within the influence of the ambient environment. Fluctuations in room temperature place additional demands on this control process and can extend the time required to establish stable measurement conditions. Maintaining a consistent laboratory environment, preferably through air conditioning, therefore helps the apparatus achieve steady-state readings more efficiently.

Guarded Hot Plate Thermal Conductivity Tester - QualiGTX™ GHP Technical Specifications

Parameter Specification
Test Principle Steady-state guarded hot plate
Measured Property Thermal conductivity (lambda), thermal resistance
Measurement Range 0.010 to 3.000 W/(m·K)
Specimen Size 300 × 300 mm
Specimen Thickness 10 to 45 mm (25 mm preferred)
Cold Plate Temperature 5 °C to 50 °C
Hot Plate Temperature Ambient to 80 °C
Test Accuracy ≤ 2%
Test Repeatability < 1%
Specimen Handling Automated loading with uniform clamping
Applicable Materials Foam concrete, insulation mortars, rigid insulation boards, and similar materials
Operating Environment 10 °C to 40 °C, air-conditioned laboratory recommended
Voltage AC 220 V, 2 kW total (110V is also available)
Dimensions (W × D × H) 800 × 600 × 1600 mm
Weight 215 kg

Delivery time varies upon stock availability. Our standard dispatch and shipping times are generally within 1 week, however for some high demand items the delivery may be extended to 2-3 weeks. If you require these items urgently please contact us to check accurate stock availability and to organize faster shipping methods.

🚚

Important Delivery Information

Delivery time varies upon stock availability. Our standard dispatch and shipping times are generally within 1 week, however for some high demand items the delivery may be extended to 2-3 weeks.

Need it urgently? Contact us here to check stock and organize faster shipping.

Orders:
Purchaser acknowledges that when placing an order on the Qualitest:

A. the placing of the order signifies the purchaser's assent to place said order at the Qualitest and that the order will be accepted by the successful processing of the order by Qualitest USA LC.
B. the purchaser typing their name when requested to do so by the Qualitest constitutes a signature to contract
C. the purchaser has the full authority to enter into the contract for such entity, and such grant of authority was indicated by purchaser by placement of the order through the Qualitest.
D. A minimum handling fee will be applied to the shipping total for all orders.

Shipping within the U.S.A.:

All orders will be shipped best way prepaid, via courier for smaller packages or via Freight forwarders for larger crates. A handling fee may be applicable to orders. Title to merchandise transfers to the purchaser upon delivery to the carrier. Loss or damage in transit is the responsibility of the purchaser. Qualitest USA will provide assistance with information needed for processing claims.

Shipping outside of the U.S.A.:

All orders will be shipped best way, via courier for smaller packages or via Freight forwarders for larger crates. A low handling fee may be applicable. Title to merchandise transfers to the purchaser upon delivery to the carrier. Loss or damage in transit is the responsibility of the purchaser. Qualitest USA will provide assistance with information needed for processing claims. Export fees, duties, taxes, and customs clearance are the responsibility of the purchaser.

Shipping insurance is not included, please contact our sales representatives if you need shipping insurance.

Partial shipment: Qualitest USA reserves the right to make partial shipments unless otherwise instructed by the purchaser.

Payment terms: All payments to Qualitest USA are to be made in U.S. Dollars (USD)

A. Credit Card - Qualitest USA will accept Visa, Master Card, AMEX or Discover. Required information from the purchaser is the credit card number, 3 digit security code, expiration date, card holder's name (exactly as it appears on the card), billing address, and valid telephone number for us to use in case of difficulty. Qualitest USA reserves the right to delay shipment pending verification of credit card validity.
B. Wire Transfer - Transfer must be made to Qualitest and confirmed for the full purchase amount (merchandise, handling and shipping) prior to shipment. Please contact us by phone at 1.877.884.TEST (8378)(outside U.S. +1.905.944.9825) or by fax at +1.954.697.8211 for bank information.
C. Open Account - Available to U.S.A. and Canadian customers only. Terms on open accounts are Net 30 days from date of shipment. Qualitest USA reserves the right to refuse shipment of new orders if any unpaid invoices are older than 30 days. Purchasers may apply for an open account by providing:

their bank information
3 credit references from other suppliers
Please allow 5 business days for confirmation of credit and creation of an open account.

Return Policy:

Qualitest USA may accept return of purchased merchandise within North America for refund or credit under the following conditions -

  • There may be an additional restocking fee charged to the transaction if items are already shipped to customer.
  • Goods must be returned to Qualitest USA within 5 days of the date of the receipt of the purchased goods.
  • All freight, duties, customs, and other related shipping charges for the returned merchandise are borne by the purchaser. Shipments made freight collect will be refused.
  • Merchandise must be returned properly packaged in brand new, salable condition, along with original packaging and all documentation, accessories and certificates.
  • Purchaser has confirmed return authorization directly with Qualitest.
  • Merchandise is regular catalog item. Special order items can not be returned.
  • All returned merchandise is subject to inspection by Qualitest. Qualitest reserves the right to refuse return of any merchandise that is used, damaged, or not part of the current published price list. In the case Qualitest does not accept the returned merchandise, reasonable attempts will be made to notify the Buyer and the merchandise will be returned to Buyer as they were received by Qualitest. Damaged merchandise that can be restored to original condition and thus accepted for return will be evaluated on an individual basis. The purchaser will be advised of additional expenses for the repair and restoration of the returned item. After approval, these expenses will be charged to the purchaser in addition to the restocking fee.


Change of Terms:

The acceptance of any order by Qualitest USA is subject to purchaser's assent to all of the terms and conditions set forth herein. Purchaser's assent to these terms and conditions shall be presumed from the purchaser's placement of an order through the Qualitest. Any and all other terms and conditions are expressly rejected, and no addition or modification of terms and conditions shall be binding without the prior agreement of Qualitest USA in writing.

Complete Agreement:

The terms and conditions in the Qualitest web site, incorporated herein by reference, including forms, acknowledgements, quotations, invoices and sales terms and conditions constitute the entire and exclusive agreement between the purchaser and Qualitest USA LC.

Information:

Qualitest USA makes every effort to insure the accuracy of the product information displayed on its web sites, but makes no warranties, expressed or implied, as to the accuracy of the data portrayed on the web sites. Qualitest USA reserves the right to change product information, including pricing information at any time without notice. 

Trademarks and Copyrights:

The WorldofTest.com Qualitest contains trademarked product names. Product names are not to be reproduced or used in any fashion by any party other than Qualitest without the express written consent of Qualitest International Inc.. All pictures, descriptions, and other content of this web site are copyrighted by Qualitest USA and may not be used without the express written permission of Qualitest USA. Purchaser acknowledges that they have no right, title, or interest in the trademarks or copyrights in the products, and purchaser covenants that it will take no action to register or otherwise interfere with such rights. Please contact us with any requests for permission or questions about our trademarks. 

Warranty Disclaimer:

No warranty or affirmation of fact, express or implied, other than expressly set forth herein is made or authorized by Qualitest USA. Qualitest USA disclaims any and all liability for product defect claims. Qualitest USA does not express or imply a warranty that any product on the web site(s) is fit for a particular purpose. Qualitest USA honors the product warranty as published and made available by Qualitest USA. Warranty claims for products not manufactured by Qualitest are the responsibility of the manufacturer. Qualitest USA will always make its best good faith effort to resolve warranty claims. 


Force Majeure:

Qualitest USA shall not be liable for any delay in or impairment of performance resulting in whole or in part from Acts of God, service interruptions, labor disruptions, insurrections, governmental decrees or controls, war risks, severe weather, supplies or raw materials, inability to procure or ship products, inability to obtain permits and/or licenses, or any other circumstances or causes beyond the control of Qualitest USA in the conduct of its business. 

Qualitest USA Privacy Policy 

I. What legal provisions govern our data processing practices? How and from where (internal/external sources) is personal data acquired? What are the rights of the user (web site visitor/registered customer)? 

1. General
As a general principle, no personal details need to be provided when visiting our Internet site. Data made available to us by you is treated in strict confidence and in accordance with the provisions of the Federal Data Protection Act. With a few exceptions (see point 2 below), our web server only registers non-personal (anonymous) data concerning the use of our site. Specifically, the log files of our web server, as a general rule, only contain the user's IP address, the last page visited by the user, the browser used, date, time and the file requested. This anonymous data, however, does not permit conclusions to be drawn about the individual users, and merely serves to prepare statistics on the use of our Internet site for the purpose of its improvement. At the same time, great importance is placed on ensuring that usage data is not linked with personal data. 

2. Personal data

Person-related data (personal data) is only used if the newsletter is ordered (by email), product(s) is (are) ordered, or to supply product information. We undertake to use the personal data entrusted to us only for the purposes stated. Purchase history is retained for assistance with future customer needs. 

II. What security measures are used to protect personal data? What are the user's options for processing personal data? 

3. Technical measures

Databases are optimally protected against third party access, loss, misuse and falsification through the use of appropriate technical means. In order to determine the popularity of individual topic areas, cookies are used in those sections. These text files are stored on your hard disk and facilitate your use of our Internet site. Thanks to these cookies, there is no need for specific registration each time you visit a section requiring registration, and we can supply you with the personalized contents you request. 

It is for you to decide whether you want to work with cookies and, if so, which kind (permanently stored on the hard disk or only placed for the time of the browser activity). However, we draw your attention to the fact that access to fields requiring registration is only possible with activated cookies. 

III. What data is communicated to third parties and for what purposes? 

4. Communication of personal data

Personal data entrusted to us by you is not communicated, leased or sold to third parties. 

IV. Which department answers questions about the processing of personal data? 

5. Contact

In the light of the rapid technical developments in connection with the Internet, we make every effort to constantly improve our Internet site and technical precautions, including those connected with data protection. We will keep you suitably informed about such measures. Any changes will be published here. Further information is available at any time by contacting Qualitest USA.

Disclaimer of liability Qualitest USA shall not be liable for direct, indirect or consequential losses resulting from or in connection with access to, use of or queries to the Qualitest web site or its links with other web sites, even if Qualitest USA has previously been informed of the possibility of such losses. No guarantee is provided as to the accuracy of the information disseminated via the Qualitest USA web site. In addition, Qualitest USA guarantees neither the reliability nor the completeness of the information contained on its web site. The information made available on the Qualitest and WorldofTest.com web site may be amended at any time without prior notice. In particular, Qualitest USA shall not be liable for losses caused by transmission errors, technical faults and interruptions, breakdowns or an unlawful interference with the user's data processing system or the generally accessible systems and transmission networks. Nor shall Qualitest USA be liable for losses resulting from breakdowns, interruptions or overloads occurring to any data processing systems. If certain links are activated on the Qualitest and WorldofTest.com web site, the user may under certain circumstances leave the Qualitest web site. Qualitest USA assumes no responsibility for the contents, products or services offered or other information or offers contained on these linked web sites. 

Related Products