The QualiFlame™ GWT is a high-performance glow wire tester designed for precision fire hazard and flammability simulation. Engineered for electronics and appliance R&D, it delivers reliable thermal contact testing from 500°C to 1000°C under a 0.97 N force without compromising on safety or global compliance.

  • 500°C To 1000°C Temperature
  • Precise 0.97 N Force
  • Controlled 7 Mm Penetration
  • Accurate 30 Second Timer

Get personalized pricing for your specific requirements

Glow Wire Tester – QualiFlame™ GWT

Glow Wire Test Apparatus for Electrical Insulation and Plastics

The QualiFlame™ GWT Glow Wire Tester is designed for fire hazard testing of electrotechnical products, plastics, and electrical insulation materials. The system uses an electrically heated nickel-chromium loop as the ignition source to evaluate how finished products, molded components, and insulation materials respond when exposed to a glowing element.

The glow wire test apparatus operates from 500°C to 1000°C with temperature stability of ±2°C. During testing, the heated wire contacts the specimen under a calibrated force of 0.97 N. The instrument is suitable for appliance manufacturers, electrical component suppliers, polymer testing laboratories, and certification organizations conducting glow wire flammability and fire resistance evaluations.

Available Configurations

The QualiFlame™ GWT is available in two configurations: a version with an integrated test chamber and a configuration without the chamber. The chambered model provides an enclosed testing area exceeding 0.5 m³, featuring a dark interior and black test background to improve flame visibility through the large viewing window.

An included exhaust pipe helps direct combustion products away from the testing area during operation. A touchscreen control system manages the test sequence, while a separate remote control box provides convenient operation near the specimen.

Temperature and Ignition Time Measurement

A digital timer controls the standard 30-second contact period with an accuracy of ±0.1 seconds. Separate timing channels measure ignition time and flame extinction time over a range of 0 to 999.9 seconds. Test timing data is recorded automatically, while manual timeout control is also available when required.

The system uses an armored Type K thermocouple rated from -40°C to 1100°C to measure the glow wire tip temperature. Temperature data is displayed through a digital indicator for clear monitoring during the test.

Glow Wire Heating and Safety Features

The QualiFlame™ GWT provides continuously variable current adjustment for precise control of glow wire heating. A built-in ammeter allows operators to monitor the heating current directly during testing.

For electrical protection, the control system incorporates fuses and a miniature circuit breaker. These safety components help protect the electrical control circuit during operation.

The QualiFlame™ GWT provides a controlled setup for glow wire testing, fire hazard evaluation, ignition behavior analysis, and flame extinction measurement of electrical insulation, plastics, and electrotechnical components.

Glow Wire Tester – QualiFlame™ GWT Applications

The QualiFlame™ GWT Glow Wire Tester supports fire hazard evaluation for electrical products, plastics, polymer materials, and electrical insulation. It is suitable for product development, quality assessment, material evaluation, and third-party testing.

  • Household Appliance Manufacturing: Evaluates housings, terminal blocks, and internal plastic components used in refrigerators, washing machines, and small kitchen appliances for resistance to ignition caused by overheated components.

  • Electrical Connectors and Terminal Blocks: Tests insulating housings and components positioned near current-carrying conductors and screw terminals to assess ignition behavior under glowing wire contact.

  • Switches, Sockets, and Wiring Accessories: Evaluates finished wiring devices to determine their response to contact with a heated glow wire and assess the potential for localized ignition to spread.

  • Plastics and Polymer Compounding: Supports evaluation of flame-retardant polymer formulations by analyzing ignition temperature and burning behavior during material development and grade qualification.

  • Wire and Cable Insulation: Assesses insulation and jacketing compounds for resistance to ignition when exposed to glowing contact points, overheated connections, or similar thermal conditions.

  • Lighting Fixtures and Luminaires: Tests lamp holders, drivers, diffusers, and other polymer components positioned near sustained heat sources.

  • Automotive Electrical Components: Evaluates fuse boxes, relay housings, connector bodies, and other electrical components used in automotive wiring systems.

  • IT and Audio-Video Equipment: Tests enclosure materials and internal polymer components used in power supplies, adapters, and electronic equipment for their response to glowing wire contact.

  • Certification and Third-Party Laboratories: Supports glow wire testing for product evaluation, including the determination of glow wire flammability and ignition temperature characteristics for certification and approval processes.

Glow Wire Tester Standards

The QualiFlame™ GWT is designed around internationally recognized glow wire test methods covering apparatus configuration, glow wire temperature control, specimen contact, and testing procedures.

  • IEC 60695-2-10: Fire hazard testing – Part 2-10: Glowing/hot-wire based test methods – Glow-wire apparatus and common test procedure.

  • UL 746A: Standard for Polymeric Materials – Short Term Property Evaluations.

These standards provide test procedures and requirements used to evaluate the fire-related behavior of polymeric and electrical insulating materials under controlled glow wire conditions.

Glow Wire Tester – QualiFlame™ GWT Key Features

The QualiFlame™ GWT Glow Wire Tester combines precise temperature control, automated timing, and adjustable electrical current to provide consistent and controlled glow wire testing for plastics, electrical insulation, and electrotechnical components.

  • Touchscreen Program Control: Controls the approach, contact, dwell, and withdrawal sequence according to preset parameters, reducing operator-dependent timing variations during glow wire testing.

  • Remote Control Box: Allows operators to start and stop the test sequence from a convenient position while maintaining direct visibility of the specimen.

  • Optional Integrated Test Chamber: Available with or without an integrated enclosure, providing flexibility for laboratories with existing extraction or testing enclosures.

  • Precision Contact Timer: Controls the standard 30-second contact period with ±0.1 s accuracy and provides a timer range from 0 to 9999 seconds.

  • Separate Ignition and Extinction Timing Channels: Records ignition and flame extinction times independently over a range of 0 to 999.9 seconds, with automatic data recording and manual timeout functionality.

  • Continuously Variable Current Adjustment: Provides smooth control of glow wire heating current, allowing operators to achieve the required tip temperature without changing fixed current ranges.

  • Built-In Ammeter Monitoring: Displays glow wire current in real time, providing an additional reference during temperature setup and test operation.

  • Digital Temperature Indicator: Displays the measured glow wire tip temperature directly for convenient monitoring during calibration and testing.

  • Armored Type K Thermocouple: Covers a temperature range of -40°C to 1100°C and is designed for repeated glow wire testing cycles.

  • Nickel-Chromium 80/20 Glow Wire: Uses a Ø4 mm ±0.04 mm nickel-chromium glow wire to maintain the specified geometry and consistent heat transfer during testing.

  • Calibrated Application Force: Applies the specified contact force to help maintain consistent specimen contact and improve test repeatability between laboratories.

  • Controlled 7 mm Penetration Limit: Limits glow wire travel to the specified penetration depth, helping prevent excessive penetration through thin test specimens.

  • Dark Interior and Black Background: Improves visibility of brief or low-intensity flames, supporting accurate observation and timing during the test.

  • Supplied Exhaust Pipe and Buckle: Provides a dedicated route for combustion products to exit the test area without requiring a custom extraction connection.

  • Consumables Kit Included: Includes a spare glow wire loop, thermocouple, silver foil, metal brush, pine board, tissue paper, and specimen disc for testing and maintenance requirements.

  • Fuse and Miniature Circuit Breaker Protection: Provides electrical protection for the control circuit against overload during extended testing and high-temperature operation.

  • Customizable Power Supply and Interface Language: Supports different local power supply configurations and operator interface language requirements for international laboratory use.

Theory and Method

The QualiFlame™ GWT Glow Wire Tester reproduces a localized thermal failure that can occur in electrical and electronic products. An overheated component, damaged connection, overloaded resistor, or heating element can reach high temperatures and come into contact with nearby plastic or electrical insulation. Glow wire testing evaluates whether the material ignites under this contact and measures how long any resulting flame continues after the heat source is removed.

The test uses a 4 mm diameter nickel-chromium 80/20 glow wire as the standardized heat source. Its electrical resistance and thermal characteristics provide a controlled heating element for repeatable testing cycles.

Resistive Heating and Temperature Control

Electrical current passes through the nickel-chromium wire, generating heat through electrical resistance. The glow wire reaches an equilibrium temperature when the electrical heat input balances heat losses through radiation and convection.

An armored Type K thermocouple positioned at the glow wire tip measures the actual temperature directly. This provides a more reliable temperature measurement than estimating temperature from electrical current alone. The control panel includes adjustable current control and an ammeter, allowing operators to fine-tune the heating conditions before and during testing.

Specimen Contact and Mechanical Control

Mechanical test parameters are also critical for consistent glow wire testing. The specimen carriage advances at 18 mm/s, applies a calibrated contact force of 0.97 N, and limits penetration to 7 mm. These controlled parameters help prevent excessive penetration through thin-wall specimens and maintain consistent contact conditions throughout the test.

During the test, operators monitor and record key observations, including ignition time, flame extinction time after glow wire withdrawal, and whether burning particles ignite the tissue paper positioned on the pine board beneath the specimen.

The resulting observations can be used to determine the applicable flammability index, ignition temperature characteristics, or pass/fail assessment, depending on the test method and product requirements.

Glow Wire Tester - QualiFlame™ GWT Technical Specifications

Parameter Specification
Model QualiFlame™ GWT
Configuration With or without integrated test chamber
Glow Wire Element Ø4 mm ±0.04 mm, nickel-chromium 80/20
Temperature Range 500°C to 1000°C, continuously adjustable
Temperature Accuracy ±2°C
Thermocouple Ø1.0 mm Type K (Ni/Cr-Ni/Al), armored sheath rated -40°C to 1100°C
Searing Time 30 s ±0.1 s (OMRON H5CN-XAN-Z digital timer, 0 s to 9999 s, preset table)
Ignition Timing 0 s to 999.9 s ±0.1 s, automatic recording, manual timeout
Flame Extinction Timing 0 s to 999.9 s ±0.1 s, automatic recording, manual timeout
Penetration Depth 7 mm ±0.5 mm
Application Force 0.97 N ±0.1 N
Approach Speed 18 ±3 mm/s
Test Background Black
Test Process Automatic control, independent test cycle
Test Chamber Volume ≥0.5 m³ (chambered configuration)
Control System Microcontroller with touch screen program
Reference Standards IEC 60695-2-10, UL 746A
Voltage 220 V, 48 Hz to 60 Hz, 800 VA (110V is also available)
Display Panel Language English (other languages available on request)

Delivery time varies upon stock availability. Our standard dispatch and shipping times are generally within 1 week, however for some high demand items the delivery may be extended to 2-3 weeks. If you require these items urgently please contact us to check accurate stock availability and to organize faster shipping methods.

🚚

Important Delivery Information

Delivery time varies upon stock availability. Our standard dispatch and shipping times are generally within 1 week, however for some high demand items the delivery may be extended to 2-3 weeks.

Need it urgently? Contact us here to check stock and organize faster shipping.

Orders:
Purchaser acknowledges that when placing an order on the Qualitest:

A. the placing of the order signifies the purchaser's assent to place said order at the Qualitest and that the order will be accepted by the successful processing of the order by Qualitest USA LC.
B. the purchaser typing their name when requested to do so by the Qualitest constitutes a signature to contract
C. the purchaser has the full authority to enter into the contract for such entity, and such grant of authority was indicated by purchaser by placement of the order through the Qualitest.
D. A minimum handling fee will be applied to the shipping total for all orders.

Shipping within the U.S.A.:

All orders will be shipped best way prepaid, via courier for smaller packages or via Freight forwarders for larger crates. A handling fee may be applicable to orders. Title to merchandise transfers to the purchaser upon delivery to the carrier. Loss or damage in transit is the responsibility of the purchaser. Qualitest USA will provide assistance with information needed for processing claims.

Shipping outside of the U.S.A.:

All orders will be shipped best way, via courier for smaller packages or via Freight forwarders for larger crates. A low handling fee may be applicable. Title to merchandise transfers to the purchaser upon delivery to the carrier. Loss or damage in transit is the responsibility of the purchaser. Qualitest USA will provide assistance with information needed for processing claims. Export fees, duties, taxes, and customs clearance are the responsibility of the purchaser.

Shipping insurance is not included, please contact our sales representatives if you need shipping insurance.

Partial shipment: Qualitest USA reserves the right to make partial shipments unless otherwise instructed by the purchaser.

Payment terms: All payments to Qualitest USA are to be made in U.S. Dollars (USD)

A. Credit Card - Qualitest USA will accept Visa, Master Card, AMEX or Discover. Required information from the purchaser is the credit card number, 3 digit security code, expiration date, card holder's name (exactly as it appears on the card), billing address, and valid telephone number for us to use in case of difficulty. Qualitest USA reserves the right to delay shipment pending verification of credit card validity.
B. Wire Transfer - Transfer must be made to Qualitest and confirmed for the full purchase amount (merchandise, handling and shipping) prior to shipment. Please contact us by phone at 1.877.884.TEST (8378)(outside U.S. +1.905.944.9825) or by fax at +1.954.697.8211 for bank information.
C. Open Account - Available to U.S.A. and Canadian customers only. Terms on open accounts are Net 30 days from date of shipment. Qualitest USA reserves the right to refuse shipment of new orders if any unpaid invoices are older than 30 days. Purchasers may apply for an open account by providing:

their bank information
3 credit references from other suppliers
Please allow 5 business days for confirmation of credit and creation of an open account.

Return Policy:

Qualitest USA may accept return of purchased merchandise within North America for refund or credit under the following conditions -

  • There may be an additional restocking fee charged to the transaction if items are already shipped to customer.
  • Goods must be returned to Qualitest USA within 5 days of the date of the receipt of the purchased goods.
  • All freight, duties, customs, and other related shipping charges for the returned merchandise are borne by the purchaser. Shipments made freight collect will be refused.
  • Merchandise must be returned properly packaged in brand new, salable condition, along with original packaging and all documentation, accessories and certificates.
  • Purchaser has confirmed return authorization directly with Qualitest.
  • Merchandise is regular catalog item. Special order items can not be returned.
  • All returned merchandise is subject to inspection by Qualitest. Qualitest reserves the right to refuse return of any merchandise that is used, damaged, or not part of the current published price list. In the case Qualitest does not accept the returned merchandise, reasonable attempts will be made to notify the Buyer and the merchandise will be returned to Buyer as they were received by Qualitest. Damaged merchandise that can be restored to original condition and thus accepted for return will be evaluated on an individual basis. The purchaser will be advised of additional expenses for the repair and restoration of the returned item. After approval, these expenses will be charged to the purchaser in addition to the restocking fee.


Change of Terms:

The acceptance of any order by Qualitest USA is subject to purchaser's assent to all of the terms and conditions set forth herein. Purchaser's assent to these terms and conditions shall be presumed from the purchaser's placement of an order through the Qualitest. Any and all other terms and conditions are expressly rejected, and no addition or modification of terms and conditions shall be binding without the prior agreement of Qualitest USA in writing.

Complete Agreement:

The terms and conditions in the Qualitest web site, incorporated herein by reference, including forms, acknowledgements, quotations, invoices and sales terms and conditions constitute the entire and exclusive agreement between the purchaser and Qualitest USA LC.

Information:

Qualitest USA makes every effort to insure the accuracy of the product information displayed on its web sites, but makes no warranties, expressed or implied, as to the accuracy of the data portrayed on the web sites. Qualitest USA reserves the right to change product information, including pricing information at any time without notice. 

Trademarks and Copyrights:

The WorldofTest.com Qualitest contains trademarked product names. Product names are not to be reproduced or used in any fashion by any party other than Qualitest without the express written consent of Qualitest International Inc.. All pictures, descriptions, and other content of this web site are copyrighted by Qualitest USA and may not be used without the express written permission of Qualitest USA. Purchaser acknowledges that they have no right, title, or interest in the trademarks or copyrights in the products, and purchaser covenants that it will take no action to register or otherwise interfere with such rights. Please contact us with any requests for permission or questions about our trademarks. 

Warranty Disclaimer:

No warranty or affirmation of fact, express or implied, other than expressly set forth herein is made or authorized by Qualitest USA. Qualitest USA disclaims any and all liability for product defect claims. Qualitest USA does not express or imply a warranty that any product on the web site(s) is fit for a particular purpose. Qualitest USA honors the product warranty as published and made available by Qualitest USA. Warranty claims for products not manufactured by Qualitest are the responsibility of the manufacturer. Qualitest USA will always make its best good faith effort to resolve warranty claims. 


Force Majeure:

Qualitest USA shall not be liable for any delay in or impairment of performance resulting in whole or in part from Acts of God, service interruptions, labor disruptions, insurrections, governmental decrees or controls, war risks, severe weather, supplies or raw materials, inability to procure or ship products, inability to obtain permits and/or licenses, or any other circumstances or causes beyond the control of Qualitest USA in the conduct of its business. 

Qualitest USA Privacy Policy 

I. What legal provisions govern our data processing practices? How and from where (internal/external sources) is personal data acquired? What are the rights of the user (web site visitor/registered customer)? 

1. General
As a general principle, no personal details need to be provided when visiting our Internet site. Data made available to us by you is treated in strict confidence and in accordance with the provisions of the Federal Data Protection Act. With a few exceptions (see point 2 below), our web server only registers non-personal (anonymous) data concerning the use of our site. Specifically, the log files of our web server, as a general rule, only contain the user's IP address, the last page visited by the user, the browser used, date, time and the file requested. This anonymous data, however, does not permit conclusions to be drawn about the individual users, and merely serves to prepare statistics on the use of our Internet site for the purpose of its improvement. At the same time, great importance is placed on ensuring that usage data is not linked with personal data. 

2. Personal data

Person-related data (personal data) is only used if the newsletter is ordered (by email), product(s) is (are) ordered, or to supply product information. We undertake to use the personal data entrusted to us only for the purposes stated. Purchase history is retained for assistance with future customer needs. 

II. What security measures are used to protect personal data? What are the user's options for processing personal data? 

3. Technical measures

Databases are optimally protected against third party access, loss, misuse and falsification through the use of appropriate technical means. In order to determine the popularity of individual topic areas, cookies are used in those sections. These text files are stored on your hard disk and facilitate your use of our Internet site. Thanks to these cookies, there is no need for specific registration each time you visit a section requiring registration, and we can supply you with the personalized contents you request. 

It is for you to decide whether you want to work with cookies and, if so, which kind (permanently stored on the hard disk or only placed for the time of the browser activity). However, we draw your attention to the fact that access to fields requiring registration is only possible with activated cookies. 

III. What data is communicated to third parties and for what purposes? 

4. Communication of personal data

Personal data entrusted to us by you is not communicated, leased or sold to third parties. 

IV. Which department answers questions about the processing of personal data? 

5. Contact

In the light of the rapid technical developments in connection with the Internet, we make every effort to constantly improve our Internet site and technical precautions, including those connected with data protection. We will keep you suitably informed about such measures. Any changes will be published here. Further information is available at any time by contacting Qualitest USA.

Disclaimer of liability Qualitest USA shall not be liable for direct, indirect or consequential losses resulting from or in connection with access to, use of or queries to the Qualitest web site or its links with other web sites, even if Qualitest USA has previously been informed of the possibility of such losses. No guarantee is provided as to the accuracy of the information disseminated via the Qualitest USA web site. In addition, Qualitest USA guarantees neither the reliability nor the completeness of the information contained on its web site. The information made available on the Qualitest and WorldofTest.com web site may be amended at any time without prior notice. In particular, Qualitest USA shall not be liable for losses caused by transmission errors, technical faults and interruptions, breakdowns or an unlawful interference with the user's data processing system or the generally accessible systems and transmission networks. Nor shall Qualitest USA be liable for losses resulting from breakdowns, interruptions or overloads occurring to any data processing systems. If certain links are activated on the Qualitest and WorldofTest.com web site, the user may under certain circumstances leave the Qualitest web site. Qualitest USA assumes no responsibility for the contents, products or services offered or other information or offers contained on these linked web sites. 

Related Products