Semi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA

QualiFi™ 6000SA is a semi-automatic, safety-enhanced melt flow indexer developed for B2B plastics testing laboratories that require higher throughput, reduced operator involvement, and improved safety compared to a standard automatic weight-loading instrument. It measures MFR across 0.1–100 g/10 min and MVR up to 3000 cm³/10 min at temperatures from 50 to 450 °C. This melt flow index tester integrates pneumatic material compaction, pneumatic residual extrusion, pneumatic barrel cleaning, and a weight fall-prevention guard within the QualiFi™ Series platform—delivering a safer, faster, and more repeatable testing workflow than the QualiFi™ 5000. CE certified and CNAS proficiency-verified, the QualiFi™ 6000SA is a reliable upgrade melt flow index tester for high-frequency QC and production monitoring environments across North America.

The QualiFi™ 6000SA is a pneumatic-assisted semi-automatic melt flow indexer designed for plastics testing environments where test throughput, operator safety, and measurement repeatability are higher priorities than compact benchtop design. Built on the QualiFi™ Series platform, it retains the core measurement precision, dual PID temperature control, and software capabilities of the QualiFi™ 5000 while adding pneumatic-assisted functions and a weight fall-prevention guard that reduce manual intervention, minimize human error, and improve operator safety during frequent testing cycles.

The weight is manually selected by the operator but automatically lifted and lowered without physical handling once selected, similar to the QualiFi™ 5000 lifting mechanism. A weight fall-prevention guard is added in the 6000SA, physically securing the weight stack and reducing the risk of uncontrolled weight movement during operation. Material compaction is performed pneumatically with adjustable force and time (10–50 kg), removing variability from manual compaction and improving repeatability for high-viscosity materials.

Pneumatic residual material extrusion uses adjustable pneumatic load (10–50 kg) to remove remaining polymer from the barrel after each test, reducing between-test cleaning time and effort. Pneumatic barrel cleaning completes the post-test cycle using compressed air to clear internal residue, eliminating the need for manual rod cleaning typically required on standard melt flow index testers. These three pneumatic functions reduce total turnaround time between tests, making the QualiFi™ 6000SA suitable for high-frequency QC environments where multiple tests are performed per shift.

All core QualiFi™ Series platform features are retained, including the 10.1-inch HD touch screen, 50–450 °C dual PID temperature control, ±0.2 °C temperature accuracy, 0.002 mm piston displacement resolution, 8 customizable test plans, 5,000-group USB data storage with DMS software, optional PC two-way control, and multi-language interface support. The floor-standing design (580×480×1450 mm) accommodates the pneumatic assembly and weight guard system and requires a compressed air supply above 0.6 MPa.

Semi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA Applications

The QualiFi™ 6000SA melt flow indexer is designed for B2B plastics testing environments where test frequency, operational safety, and throughput are key requirements, and where variations from manual compaction in a standard melt flow index tester can impact result consistency.

High-Frequency Production QC:
Incoming and outgoing inspection of polyolefin, engineering plastic, and specialty resin batches at high testing volumes. Pneumatic cleaning and residual extrusion reduce between-test downtime and improve workflow efficiency.

High-Viscosity Polymer Testing:
MFR/MVR evaluation of materials such as nylon, polycarbonate, fluoroplastics, and other engineering resins requiring stable and repeatable compaction force. Pneumatic compaction eliminates operator-dependent variation associated with manual loading.

Petrochemical & Compounding Lines:
Process control and product validation of polymer melts and compound formulations that require consistent test conditions and fast changeover between samples without dismantling the barrel assembly.

Plastics Manufacturing Operations:
Batch qualification, supplier verification, and extrusion or injection molding process monitoring based on defined MFR limits in accordance with ISO 1133 and ASTM D1238 standards.

Regulated & Accredited Laboratories:
Third-party testing, certification, and inspection workflows requiring traceable data export, user access control, and CNAS-verified measurement consistency across repeated test cycles.

Academic & Applied Research:
Polymer behavior analysis, blend formulation studies, and comparative melt flow testing across material grades with detailed data logging and reproducible test conditions.

Standards

The QualiFi™ 6000SA melt flow indexer is designed and verified in accordance with internationally recognized standards for thermoplastic melt flow rate testing, laboratory measurement accuracy, and equipment safety.

  • ISO 1133-1:2011 — Plastics: Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics — Part 1: Standard procedure
  • ISO 1133-2:2011 — Plastics: Determination of MFR and MVR of thermoplastics — Part 2: Method for materials sensitive to time-temperature history and/or moisture
  • ASTM D1238 — Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer (Procedures A and B)
  • IEC 61010-1 / EN 61010-1:2010+A1:2019 — Safety requirements for electrical equipment used in measurement, control, and laboratory applications (CE certified)
  • EN 61326-1:2013 — Electrical equipment for measurement, control, and laboratory use: EMC requirements (CE certified)
  • ISO 9001:2015 — Quality management system standard applied to laboratory instrument manufacturing processes

Certifications and Proficiency Verification

The QualiFi™ 6000SA is built on the validated QualiFi™ Series platform and maintains the same core compliance framework across the product family, including CE certification and repeated CNAS proficiency testing validation.

CE Certification:
Complies with EN 61010-1:2010+A1:2019 (Low Voltage Directive) and EN 61326-1:2013 (EMC requirements), confirmed through ECM Certificate of Compliance.

CNAS Proficiency Testing:
Verified through consecutive CNAS inter-laboratory proficiency comparisons, with all results within acceptable limits. Reported Z-scores remain in the range of −0.07 to +0.11 across all evaluation rounds.

Technical Patents:
The QualiFi™ Series includes multiple registered technical patents covering core measurement systems, thermal control architecture, and structural design innovations.

Semi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA Key Features

Pneumatic Systems and Safety Step-up from QualiFi™ 5000

The QualiFi™ 6000SA integrates enhanced pneumatic systems over the QualiFi™ 5000, improving consistency, efficiency, and operator safety in melt flow index testing workflows.

Pneumatic Material Compaction (10–50 kg adjustable):
Provides controlled compaction force and timing, eliminating operator-dependent variation during sample preparation and improving run-to-run MFR/MVR repeatability.

Pneumatic Residual Material Extrusion (10–50 kg adjustable):
Uses controlled pneumatic load to remove remaining polymer from the barrel after testing, reducing reliance on manual rod operation and accelerating post-test processing.

Pneumatic Barrel Cleaning:
Applies compressed air to clear residual material from the barrel interior, significantly reducing between-test preparation time and improving efficiency in high-frequency testing environments.

Weight Fall-Prevention Guard:
A mechanical safety system that physically secures the weight stack, preventing uncontrolled descent during setup, weight changes, or loading operations. This adds an extra layer of operational safety compared to the QualiFi™ 5000.

Preloading System (Dual Mode):
Supports two controlled loading ranges to ensure accurate and repeatable test conditions across different materials:

  • Calibration weight load: 0.325–21.6 kg
  • Additional load: 10–50 kg

Both modes allow adjustable positioning to support precise reproduction of test parameters for varied material types.

Preheating Function:
Supports both no-load and loaded preheating operation modes, enabling flexible preparation protocols based on material characteristics and specific testing requirements.

Core Measurement Platform

Core components including the oven, die, and piston are manufactured from low-thermal-expansion, corrosion-resistant alloy materials that comply with ISO 1133 dimensional stability and hardness requirements, ensuring long-term measurement accuracy under high-temperature conditions.

Temperature Control System:
Operating range: 50–450 °C
Temperature resolution: 0.01 °C
Maximum indication error: ≤0.2 °C
Fluctuation: ≤±0.2 °C
Temperature gradient: ≤±0.1 °C

The system uses dual PID temperature control for rapid, overshoot-free heating and stable regulation. After material loading, temperature recovery time is typically ≤2 minutes, supporting continuous high-frequency testing.

Measurement Precision System:
Piston displacement resolution: 0.002 mm
Maximum indication error: ±0.02 mm
Timer resolution: 0.001 s

These parameters support high-accuracy MFR/MVR determination with stable time and displacement tracking during extrusion testing.

Extended Flow Measurement Capability:
Maximum measurable flow rate reaches up to 3000 cm³/10 min, extended through a lever-operated die plug device for broader material applicability.

Weight Handling and Automation:
The system enables automatic lifting and lowering of weights without manual handling during operation. Weight selection is performed manually prior to test initiation, supporting controlled and repeatable loading conditions.

User Interface and Observation System:
A 10.1-inch HD full-color touchscreen is integrated at the front of the oven for direct control and monitoring. A variable-angle metal observation mirror with 15° adjustable viewing and a shatter-resistant surface allows safe visual inspection during operation.

Safety Structure:
A movable protective cover shields the area between the furnace body and loading mechanism during high-temperature operation, improving operator safety and reducing exposure to heated components.

Software and Data Management

The system supports Mass Method (A), Volume Method A, and Volume Method B testing, with automatic identification of ISO/ASTM test intervals and automated test initiation to streamline workflow execution.

Test Configuration:
Provides 8 customizable test plans for direct selection before testing, reducing repetitive parameter setup in routine laboratory operations and improving workflow efficiency.

Real-Time Monitoring:
Displays temperature–time and MVR–number curves in real time on the screen, enabling immediate evaluation of thermal stability and result consistency during testing.

Data Storage and Reporting:
USB flash drive storage supports up to 5,000 test result groups. Integrated DMS data management software enables data export and structured report generation for laboratory documentation and traceability.

PC Integration and Connectivity:
Optional PC software allows two-way system control and remote database upload, supporting centralized data management in multi-instrument environments.

Multi-Language Interface:
Supports English, French, German, Italian, Russian, and Chinese for flexible international laboratory use.

User Access Control:
Includes user authority management with configurable role-based permissions to safeguard measurement data integrity and prevent unauthorized parameter modifications in shared laboratory settings.

Theory and Method

Melt Flow Rate Measurement Principle

The QualiFi™ 6000SA operates based on the extrusion plastometer principle defined in ISO 1133 and ASTM D1238. A thermoplastic resin sample is introduced into a heated barrel and stabilized at the specified test temperature. A piston applies a defined load, forcing the molten polymer through a standard die (Φ2.095 mm) located at the base of the barrel.

MFR (mass method, Procedure A) is determined by measuring the mass of extrudate collected at timed intervals. MVR (volume methods A and B) is calculated from piston displacement over a defined time period. The QualiFi™ 6000SA automates weight lifting, timing control, cutting, and result calculation, while also integrating pneumatic compaction, pneumatic residual extrusion, and pneumatic barrel cleaning. These additions reduce the number of manual operations per test cycle compared to the QualiFi™ 5000.

Pneumatic Compaction System

Material compaction, the process of pressing the loaded polymer charge into the barrel prior to testing, is performed pneumatically on the QualiFi™ 6000SA with adjustable load and time (10–50 kg). In conventional melt flow index testers, this step is carried out manually using a feeding rod, which can introduce variation in applied force and compaction duration.

The pneumatic system provides a consistent and repeatable compaction force across all test cycles, independent of operator technique. This improves run-to-run repeatability of MFR/MVR results, particularly for high-viscosity polymers and powder materials where pre-test density uniformity is critical.

Pneumatic Residual Extrusion and Barrel Cleaning

After each test cycle, remaining polymer in the barrel must be removed before the next sample is introduced. The QualiFi™ 6000SA performs this in two pneumatic stages:

First, pneumatic residual extrusion applies an adjustable load (10–50 kg) to expel remaining polymer from the barrel and die, replacing manual push-rod operation used in conventional systems.

Second, pneumatic barrel cleaning uses compressed air to remove residual material from the internal barrel surface.

Together, these steps significantly reduce post-test turnaround time, minimize operator effort, and reduce exposure to high-temperature components, strengthening the safety-oriented design of the 6000SA.

Weight Fall-Prevention Guard

In floor-standing melt flow indexers, the weight stack is positioned at an elevated height, creating a potential risk of uncontrolled descent during setup, weight adjustment, or mechanical irregularities.

The QualiFi™ 6000SA incorporates a dedicated weight fall-prevention guard that physically restricts the weight stack movement and prevents uncontrolled descent events. This hardware safety mechanism is not included in the QualiFi™ 5000 and is specifically designed for the taller floor-standing structure of the 6000SA.

Dual PID Temperature Control and High-Precision Displacement

The QualiFi™ 6000SA retains the same core temperature control and measurement architecture as the QualiFi™ 5000 platform. A high-temperature heating system and sensor assembly rated for continuous operation from 50 to 450 °C is controlled by a dual PID temperature regulation system.

This ensures rapid, overshoot-free heating, stable multi-zone thermal distribution with a temperature gradient of less than ±0.1 °C, and recovery to stable conditions within 2 minutes after sample loading.

Piston displacement is measured with a resolution of 0.002 mm and a maximum indication error of ±0.02 mm. Timer resolution is 0.001 s, supporting precise MVR calculation across a measurement range of 0.01 to 3000 cm³/10 min.

Semi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA Technical Specifications

Parameter QualiFi™ 6000SA
Measurement Method MFR (mass method) / MVR (volume method A & B)
MFR Measurement Range 0.1–100 g/10min
MVR Measurement Range 0.01–3000 cm³/10min
Display Mode Full-color touch screen (10.1-inch HD)
Cutting Method Automatic cutting
Timer Resolution 0.001 s
Temperature Control Range 50–450 °C
Temperature Resolution 0.01 °C
Temperature Indication Error ≤ 0.2 °C
Temperature Fluctuation ≤ ±0.2 °C
Temperature Gradient (0–75 mm above die) ≤ ±0.3 °C
Temperature Recovery Time (after loading) ≤ 2 min
Loading Mode Electric loading — weight preset manually, auto lifted/lowered
Weight Selection Mode Manual pre-selection
Preloading Range Calibration weight: 0.325–21.6 kg; Additional load: 10–50 kg
Pneumatic Compaction Load 10–50 kg (adjustable), pneumatic operation
Pneumatic Residual Extrusion Load 10–50 kg (adjustable), pneumatic operation
Pneumatic Barrel Cleaning Yes — compressed air assisted
Weight Fall-Prevention Guard Yes — hardware fitted
Piston Displacement Indication Error ± 0.02 mm
Piston Displacement Resolution 0.002 mm
Standard Die Diameter Φ2.095 mm
Data Storage Capacity 5,000 groups (USB flash drive)
Test Plans 8 configurable and saveable test plans
Air Source Requirement > 0.6 MPa (required for pneumatic functions)
Voltage 220V (-15% / +10%) VAC, 50Hz, 0.5 kVA (110V is also available)
Dimensions L×W×H 580 × 480 × 1450 mm
Main Unit Weight 100 kg
Certifications CE (EN 61010-1:2010+A1:2019; EN 61326-1:2013); CNAS proficiency verified
Software Languages English, French, German, Italian, Russian, Chinese

Standard Configuration

Each QualiFi™ 6000SA ships with all accessories required for immediate MFR and MVR testing per ISO 1133 and ASTM D1238, plus PC software. Note that a compressed air supply of more than 0.6 MPa is required for the pneumatic functions.

Item Quantity
Main unit (including 1 barrel) 1 set
Basic weight set (piston rod, guide bush, weight tray, weight cover) 1 set
Standard die Φ2.095 mm 1 piece
Level 1 piece
Barrel cleaning rod 1 piece
Feeding rod 1 piece
Die cleaning rod 1 piece
Cutter 1 piece
Funnel 1 piece
Fuse 2 pieces
Special tweezers 2 pieces
Hexagon wrench (2 mm) 1 piece
USB flash drive 1 piece
Fixed wrench (8–10) 1 piece
Power cable 1 piece
PC software (DMS data management) 1 set

Optional Accessories

Item Description
Sample Forming Machine Compression pre-forming device for powder, flake, film fragment, or granule specimens prior to MFR/MVR testing — particularly useful for materials that cannot be loaded directly into the melt flow indexer barrel

Delivery time varies upon stock availability. Our standard dispatch and shipping times are generally within 1 week, however for some high demand items the delivery may be extended to 2-3 weeks. If you require these items urgently please contact us to check accurate stock availability and to organize faster shipping methods.

🚚

Important Delivery Information

Delivery time varies upon stock availability. Our standard dispatch and shipping times are generally within 1 week, however for some high demand items the delivery may be extended to 2-3 weeks.

Need it urgently? Contact us here to check stock and organize faster shipping.

Orders:
Purchaser acknowledges that when placing an order on the Qualitest:

A. the placing of the order signifies the purchaser's assent to place said order at the Qualitest and that the order will be accepted by the successful processing of the order by Qualitest USA LC.
B. the purchaser typing their name when requested to do so by the Qualitest constitutes a signature to contract
C. the purchaser has the full authority to enter into the contract for such entity, and such grant of authority was indicated by purchaser by placement of the order through the Qualitest.
D. A minimum handling fee will be applied to the shipping total for all orders.

Shipping within the U.S.A.:

All orders will be shipped best way prepaid, via courier for smaller packages or via Freight forwarders for larger crates. A handling fee may be applicable to orders. Title to merchandise transfers to the purchaser upon delivery to the carrier. Loss or damage in transit is the responsibility of the purchaser. Qualitest USA will provide assistance with information needed for processing claims.

Shipping outside of the U.S.A.:

All orders will be shipped best way, via courier for smaller packages or via Freight forwarders for larger crates. A low handling fee may be applicable. Title to merchandise transfers to the purchaser upon delivery to the carrier. Loss or damage in transit is the responsibility of the purchaser. Qualitest USA will provide assistance with information needed for processing claims. Export fees, duties, taxes, and customs clearance are the responsibility of the purchaser.

Shipping insurance is not included, please contact our sales representatives if you need shipping insurance.

Partial shipment: Qualitest USA reserves the right to make partial shipments unless otherwise instructed by the purchaser.

Payment terms: All payments to Qualitest USA are to be made in U.S. Dollars (USD)

A. Credit Card - Qualitest USA will accept Visa, Master Card, AMEX or Discover. Required information from the purchaser is the credit card number, 3 digit security code, expiration date, card holder's name (exactly as it appears on the card), billing address, and valid telephone number for us to use in case of difficulty. Qualitest USA reserves the right to delay shipment pending verification of credit card validity.
B. Wire Transfer - Transfer must be made to Qualitest and confirmed for the full purchase amount (merchandise, handling and shipping) prior to shipment. Please contact us by phone at 1.877.884.TEST (8378)(outside U.S. +1.905.944.9825) or by fax at +1.954.697.8211 for bank information.
C. Open Account - Available to U.S.A. and Canadian customers only. Terms on open accounts are Net 30 days from date of shipment. Qualitest USA reserves the right to refuse shipment of new orders if any unpaid invoices are older than 30 days. Purchasers may apply for an open account by providing:

their bank information
3 credit references from other suppliers
Please allow 5 business days for confirmation of credit and creation of an open account.

Return Policy:

Qualitest USA may accept return of purchased merchandise within North America for refund or credit under the following conditions -

  • There may be an additional restocking fee charged to the transaction if items are already shipped to customer.
  • Goods must be returned to Qualitest USA within 5 days of the date of the receipt of the purchased goods.
  • All freight, duties, customs, and other related shipping charges for the returned merchandise are borne by the purchaser. Shipments made freight collect will be refused.
  • Merchandise must be returned properly packaged in brand new, salable condition, along with original packaging and all documentation, accessories and certificates.
  • Purchaser has confirmed return authorization directly with Qualitest.
  • Merchandise is regular catalog item. Special order items can not be returned.
  • All returned merchandise is subject to inspection by Qualitest. Qualitest reserves the right to refuse return of any merchandise that is used, damaged, or not part of the current published price list. In the case Qualitest does not accept the returned merchandise, reasonable attempts will be made to notify the Buyer and the merchandise will be returned to Buyer as they were received by Qualitest. Damaged merchandise that can be restored to original condition and thus accepted for return will be evaluated on an individual basis. The purchaser will be advised of additional expenses for the repair and restoration of the returned item. After approval, these expenses will be charged to the purchaser in addition to the restocking fee.


Change of Terms:

The acceptance of any order by Qualitest USA is subject to purchaser's assent to all of the terms and conditions set forth herein. Purchaser's assent to these terms and conditions shall be presumed from the purchaser's placement of an order through the Qualitest. Any and all other terms and conditions are expressly rejected, and no addition or modification of terms and conditions shall be binding without the prior agreement of Qualitest USA in writing.

Complete Agreement:

The terms and conditions in the Qualitest web site, incorporated herein by reference, including forms, acknowledgements, quotations, invoices and sales terms and conditions constitute the entire and exclusive agreement between the purchaser and Qualitest USA LC.

Information:

Qualitest USA makes every effort to insure the accuracy of the product information displayed on its web sites, but makes no warranties, expressed or implied, as to the accuracy of the data portrayed on the web sites. Qualitest USA reserves the right to change product information, including pricing information at any time without notice. 

Trademarks and Copyrights:

The WorldofTest.com Qualitest contains trademarked product names. Product names are not to be reproduced or used in any fashion by any party other than Qualitest without the express written consent of Qualitest International Inc.. All pictures, descriptions, and other content of this web site are copyrighted by Qualitest USA and may not be used without the express written permission of Qualitest USA. Purchaser acknowledges that they have no right, title, or interest in the trademarks or copyrights in the products, and purchaser covenants that it will take no action to register or otherwise interfere with such rights. Please contact us with any requests for permission or questions about our trademarks. 

Warranty Disclaimer:

No warranty or affirmation of fact, express or implied, other than expressly set forth herein is made or authorized by Qualitest USA. Qualitest USA disclaims any and all liability for product defect claims. Qualitest USA does not express or imply a warranty that any product on the web site(s) is fit for a particular purpose. Qualitest USA honors the product warranty as published and made available by Qualitest USA. Warranty claims for products not manufactured by Qualitest are the responsibility of the manufacturer. Qualitest USA will always make its best good faith effort to resolve warranty claims. 


Force Majeure:

Qualitest USA shall not be liable for any delay in or impairment of performance resulting in whole or in part from Acts of God, service interruptions, labor disruptions, insurrections, governmental decrees or controls, war risks, severe weather, supplies or raw materials, inability to procure or ship products, inability to obtain permits and/or licenses, or any other circumstances or causes beyond the control of Qualitest USA in the conduct of its business. 

Qualitest USA Privacy Policy 

I. What legal provisions govern our data processing practices? How and from where (internal/external sources) is personal data acquired? What are the rights of the user (web site visitor/registered customer)? 

1. General
As a general principle, no personal details need to be provided when visiting our Internet site. Data made available to us by you is treated in strict confidence and in accordance with the provisions of the Federal Data Protection Act. With a few exceptions (see point 2 below), our web server only registers non-personal (anonymous) data concerning the use of our site. Specifically, the log files of our web server, as a general rule, only contain the user's IP address, the last page visited by the user, the browser used, date, time and the file requested. This anonymous data, however, does not permit conclusions to be drawn about the individual users, and merely serves to prepare statistics on the use of our Internet site for the purpose of its improvement. At the same time, great importance is placed on ensuring that usage data is not linked with personal data. 

2. Personal data

Person-related data (personal data) is only used if the newsletter is ordered (by email), product(s) is (are) ordered, or to supply product information. We undertake to use the personal data entrusted to us only for the purposes stated. Purchase history is retained for assistance with future customer needs. 

II. What security measures are used to protect personal data? What are the user's options for processing personal data? 

3. Technical measures

Databases are optimally protected against third party access, loss, misuse and falsification through the use of appropriate technical means. In order to determine the popularity of individual topic areas, cookies are used in those sections. These text files are stored on your hard disk and facilitate your use of our Internet site. Thanks to these cookies, there is no need for specific registration each time you visit a section requiring registration, and we can supply you with the personalized contents you request. 

It is for you to decide whether you want to work with cookies and, if so, which kind (permanently stored on the hard disk or only placed for the time of the browser activity). However, we draw your attention to the fact that access to fields requiring registration is only possible with activated cookies. 

III. What data is communicated to third parties and for what purposes? 

4. Communication of personal data

Personal data entrusted to us by you is not communicated, leased or sold to third parties. 

IV. Which department answers questions about the processing of personal data? 

5. Contact

In the light of the rapid technical developments in connection with the Internet, we make every effort to constantly improve our Internet site and technical precautions, including those connected with data protection. We will keep you suitably informed about such measures. Any changes will be published here. Further information is available at any time by contacting Qualitest USA.

Disclaimer of liability Qualitest USA shall not be liable for direct, indirect or consequential losses resulting from or in connection with access to, use of or queries to the Qualitest web site or its links with other web sites, even if Qualitest USA has previously been informed of the possibility of such losses. No guarantee is provided as to the accuracy of the information disseminated via the Qualitest USA web site. In addition, Qualitest USA guarantees neither the reliability nor the completeness of the information contained on its web site. The information made available on the Qualitest and WorldofTest.com web site may be amended at any time without prior notice. In particular, Qualitest USA shall not be liable for losses caused by transmission errors, technical faults and interruptions, breakdowns or an unlawful interference with the user's data processing system or the generally accessible systems and transmission networks. Nor shall Qualitest USA be liable for losses resulting from breakdowns, interruptions or overloads occurring to any data processing systems. If certain links are activated on the Qualitest and WorldofTest.com web site, the user may under certain circumstances leave the Qualitest web site. Qualitest USA assumes no responsibility for the contents, products or services offered or other information or offers contained on these linked web sites. 

Related Products