Compact Geosynthetic Clay Liner Permeameter – QualiGTX™ CLP C

Permeability Coefficient Testing of Geosynthetic Clay Liners and Sodium Bentonite Waterproofing Blankets

The QualiGTX™ CLP C is designed to measure the hydraulic permeability of geosynthetic clay liners (GCLs) by monitoring water movement through sodium bentonite waterproofing blankets under a controlled hydraulic differential. During testing, the laboratory measures the volume of water passing through a specimen over a defined period and uses this information, together with the specimen thickness, to determine its permeability coefficient. The instrument accommodates specimens with a diameter of ø70 mm and supports applied pressures up to 50 kPa. Its high-strength aluminum alloy specimen holder maintains secure clamping throughout the test.

Obtaining consistent permeability measurements requires careful temperature management. As hydrated bentonite restricts water movement, testing can continue for extended periods, making the results particularly sensitive to changes in water viscosity. Even minor temperature fluctuations can influence the measured flow rate and introduce inconsistencies between tests. To address this issue, the QualiGTX™ CLP C incorporates a water-conditioning system with both heating and cooling capabilities. This arrangement maintains the permeant at a predetermined temperature before it reaches the specimen, rather than allowing its temperature to fluctuate with laboratory conditions. The water supply and reservoir tank are provided in a custom configuration, making this system particularly suitable for laboratories that report permeability results at a standardized reference temperature.

The instrument also features a large-format color touchscreen for configuring test parameters, monitoring operating conditions, and managing automatic timing. This integrated interface simplifies operation during lengthy permeation tests and minimizes the need for continuous technician involvement. Its vertical column construction brings the water circuit, specimen cell, and control components together within a compact floor area of 720 × 700 mm. Qualitest North America offers the QualiGTX™ CLP C to geosynthetic manufacturers, independent testing facilities, and engineering consultancies conducting GCL permeability and containment liner conformance evaluations.

Compact Geosynthetic Clay Liner Permeameter – QualiGTX™ CLP C Applications

Permeability testing establishes whether geosynthetic clay liners provide the hydraulic barrier performance required for their intended applications. The QualiGTX™ CLP C supports this evaluation at different stages, from manufacturing quality checks and incoming material inspection to construction verification and engineering research.

  • GCL Manufacturing Quality Assurance: Provides routine permeability measurements across production batches, helping manufacturers monitor water transmission characteristics between rolls and identify inconsistencies in bentonite distribution before products leave the facility.

  • Landfill Cell and Cap Projects: Verifies that supplied GCL materials achieve the permeability requirements established in landfill containment designs, supporting barrier performance throughout construction.

  • Incoming Material Inspection: Enables independent laboratories and project quality teams to assess delivered GCL rolls against specified permeability limits before installation begins.

  • Mining and Tailings Containment Systems: Evaluates sodium bentonite barriers intended for use beneath heap leach pads, tailings storage facilities, and process water containment ponds.

  • Reservoirs, Canals, and Retention Basins: Measures the seepage resistance of GCL materials used in water storage facilities and water conveyance infrastructure.

  • Secondary Containment Installations: Supports the assessment of barrier materials specified for areas beneath storage tanks, fuel distribution facilities, and chemical containment bunds.

  • Wastewater Treatment and Agricultural Lagoons: Determines the suitability of GCL products for manure storage facilities, aeration basins, and industrial wastewater process ponds.

  • Academic and Scientific Research: Provides testing capabilities for investigations into bentonite hydration behavior, cation exchange processes, and the long-term performance of geosynthetic clay barriers.

Compact Geosynthetic Clay Liner Permeameter – QualiGTX™ CLP C Key Features

The QualiGTX™ CLP C brings together controlled water conditioning, reliable specimen containment, and automated measurement functions in a compact vertical configuration. Its features address the practical requirements of laboratories conducting extended permeability tests on sodium bentonite liners.

  • Integrated Water Heating and Cooling: Regulates permeant temperature through both heating and cooling, maintaining the selected setting and limiting viscosity-related variations that could affect comparisons between test results.

  • High-Strength Aluminum Alloy Specimen Holder: Provides firm, consistent specimen restraint while keeping the holder assembly relatively lightweight. Its construction also makes specimen replacement easier and reduces operator fatigue during repeated testing.

  • Large-Format Color Touchscreen: Provides a centralized interface for entering test conditions, viewing live operating information, and accessing results, making routine operation and operator training more straightforward.

  • Automatic Digital Timing: Controls the measurement interval without requiring manual stopwatch operation, reducing timing inconsistencies during water collection and permeability calculations.

  • Dedicated Water Reservoir: Supplies the permeation circuit from an integrated reservoir, allowing the test arrangement to operate independently of direct laboratory water supply connections.

  • Pressure Capacity up to 50 kPa: Accommodates the applied hydraulic pressure differentials required for measuring water transmission through sodium bentonite waterproofing blankets.

  • ø70 mm Specimen Compatibility: Uses a defined specimen diameter to maintain consistent flow area across tests and simplify sample preparation.

  • Space-Efficient Vertical Construction: Arranges the reservoir, specimen cell, and operating controls within a vertical frame measuring 720 × 700 mm in floor footprint.

Theory and Method

The permeability coefficient of a geosynthetic clay liner is determined by examining the relationship between water flow through the specimen and the hydraulic conditions under which that flow occurs. Four measurements form the basis of the calculation: the volume of water collected, the duration of collection, the hydraulic head difference across the specimen, and the specimen thickness.

Darcy's relationship provides the basis for calculating the coefficient:

k = QL / (A · Δh · t)

Where:

  • k = Permeability coefficient

  • Q = Volume of water passing through the specimen

  • L = Specimen thickness

  • A = Cross-sectional flow area

  • Δh = Hydraulic head difference across the specimen

  • t = Water collection period

Each measurement directly affects the calculated result. Inaccurate thickness measurements, inconsistent collection intervals, or errors in determining the hydraulic differential can therefore compromise the reported permeability coefficient. Reliable testing depends on controlling these variables throughout the measurement process.

Temperature control is another important consideration because the measured hydraulic conductivity reflects both the properties of the specimen and the behavior of the fluid passing through it. Water viscosity decreases as temperature rises, with an approximate reduction of two percent per degree Celsius near room temperature. Consequently, even modest temperature changes during an extended test can alter the measured flow rate without any corresponding change in the GCL itself.

Maintaining the permeant at a consistent temperature helps separate actual specimen performance from variations caused by fluid properties. When results must be compared under standardized conditions, measurements can also be corrected to a designated reference temperature, such as 20 °C. Combining temperature-controlled water supply with reference-temperature correction improves the consistency of reported results across different operators and testing laboratories.

The extremely low flow rates encountered during GCL testing are closely related to the hydration and swelling behavior of sodium bentonite. When exposed to water, montmorillonite mineral layers attract water molecules and hydrated sodium ions into the spaces between their layers. This process causes the bentonite particles to expand. As the material swells within its confined structure, the interconnected voids between particles become progressively smaller, leaving narrow and increasingly tortuous pathways for water movement.

The degree of swelling and the resulting restriction of water flow depend not only on hydration but also on the compressive stress applied to the material. Confinement influences how much the bentonite can expand and, consequently, how effectively it closes the available flow paths. For this reason, maintaining secure specimen containment is essential to obtaining meaningful permeability measurements. The clamping assembly must prevent water from bypassing the specimen along its perimeter, ensuring that the collected permeant represents water that has passed through the bentonite rather than leakage around its edges.

Compact Geosynthetic Clay Liner Permeameter - QualiGTX™ CLP C Technical Specifications

Parameter Specification
Test Method Permeability coefficient of sodium bentonite GCL under specified hydraulic differential
Specimen Diameter ø70 mm
Maximum Applied Pressure 50 kPa
Specimen Holder Material High-strength aluminum alloy
Control System Large-format color touchscreen
Timing Digital, automatic
Water Supply Temperature-controlled with heating and cooling, plus reservoir tank (custom configuration)
Dimensions (W × D × H) 720 × 700 × 1910 mm
Weight 110 kg

Configuration

Item Description
Specimen Holder High-strength aluminum alloy clamping assembly for ø70 mm specimens
Control System Large-format color touchscreen with automatic digital timing
Water Conditioning Unit Temperature-controlled supply with heating and cooling, custom order
Water Reservoir Permeant supply tank, custom order
Support Frame Floor-standing vertical column structure

Delivery time varies upon stock availability. Our standard dispatch and shipping times are generally within 1 week, however for some high demand items the delivery may be extended to 2-3 weeks. If you require these items urgently please contact us to check accurate stock availability and to organize faster shipping methods.

🚚

Important Delivery Information

Delivery time varies upon stock availability. Our standard dispatch and shipping times are generally within 1 week, however for some high demand items the delivery may be extended to 2-3 weeks.

Need it urgently? Contact us here to check stock and organize faster shipping.

Orders:
Purchaser acknowledges that when placing an order on the Qualitest:

A. the placing of the order signifies the purchaser's assent to place said order at the Qualitest and that the order will be accepted by the successful processing of the order by Qualitest USA LC.
B. the purchaser typing their name when requested to do so by the Qualitest constitutes a signature to contract
C. the purchaser has the full authority to enter into the contract for such entity, and such grant of authority was indicated by purchaser by placement of the order through the Qualitest.
D. A minimum handling fee will be applied to the shipping total for all orders.

Shipping within the U.S.A.:

All orders will be shipped best way prepaid, via courier for smaller packages or via Freight forwarders for larger crates. A handling fee may be applicable to orders. Title to merchandise transfers to the purchaser upon delivery to the carrier. Loss or damage in transit is the responsibility of the purchaser. Qualitest USA will provide assistance with information needed for processing claims.

Shipping outside of the U.S.A.:

All orders will be shipped best way, via courier for smaller packages or via Freight forwarders for larger crates. A low handling fee may be applicable. Title to merchandise transfers to the purchaser upon delivery to the carrier. Loss or damage in transit is the responsibility of the purchaser. Qualitest USA will provide assistance with information needed for processing claims. Export fees, duties, taxes, and customs clearance are the responsibility of the purchaser.

Shipping insurance is not included, please contact our sales representatives if you need shipping insurance.

Partial shipment: Qualitest USA reserves the right to make partial shipments unless otherwise instructed by the purchaser.

Payment terms: All payments to Qualitest USA are to be made in U.S. Dollars (USD)

A. Credit Card - Qualitest USA will accept Visa, Master Card, AMEX or Discover. Required information from the purchaser is the credit card number, 3 digit security code, expiration date, card holder's name (exactly as it appears on the card), billing address, and valid telephone number for us to use in case of difficulty. Qualitest USA reserves the right to delay shipment pending verification of credit card validity.
B. Wire Transfer - Transfer must be made to Qualitest and confirmed for the full purchase amount (merchandise, handling and shipping) prior to shipment. Please contact us by phone at 1.877.884.TEST (8378)(outside U.S. +1.905.944.9825) or by fax at +1.954.697.8211 for bank information.
C. Open Account - Available to U.S.A. and Canadian customers only. Terms on open accounts are Net 30 days from date of shipment. Qualitest USA reserves the right to refuse shipment of new orders if any unpaid invoices are older than 30 days. Purchasers may apply for an open account by providing:

their bank information
3 credit references from other suppliers
Please allow 5 business days for confirmation of credit and creation of an open account.

Return Policy:

Qualitest USA may accept return of purchased merchandise within North America for refund or credit under the following conditions -

  • There may be an additional restocking fee charged to the transaction if items are already shipped to customer.
  • Goods must be returned to Qualitest USA within 5 days of the date of the receipt of the purchased goods.
  • All freight, duties, customs, and other related shipping charges for the returned merchandise are borne by the purchaser. Shipments made freight collect will be refused.
  • Merchandise must be returned properly packaged in brand new, salable condition, along with original packaging and all documentation, accessories and certificates.
  • Purchaser has confirmed return authorization directly with Qualitest.
  • Merchandise is regular catalog item. Special order items can not be returned.
  • All returned merchandise is subject to inspection by Qualitest. Qualitest reserves the right to refuse return of any merchandise that is used, damaged, or not part of the current published price list. In the case Qualitest does not accept the returned merchandise, reasonable attempts will be made to notify the Buyer and the merchandise will be returned to Buyer as they were received by Qualitest. Damaged merchandise that can be restored to original condition and thus accepted for return will be evaluated on an individual basis. The purchaser will be advised of additional expenses for the repair and restoration of the returned item. After approval, these expenses will be charged to the purchaser in addition to the restocking fee.


Change of Terms:

The acceptance of any order by Qualitest USA is subject to purchaser's assent to all of the terms and conditions set forth herein. Purchaser's assent to these terms and conditions shall be presumed from the purchaser's placement of an order through the Qualitest. Any and all other terms and conditions are expressly rejected, and no addition or modification of terms and conditions shall be binding without the prior agreement of Qualitest USA in writing.

Complete Agreement:

The terms and conditions in the Qualitest web site, incorporated herein by reference, including forms, acknowledgements, quotations, invoices and sales terms and conditions constitute the entire and exclusive agreement between the purchaser and Qualitest USA LC.

Information:

Qualitest USA makes every effort to insure the accuracy of the product information displayed on its web sites, but makes no warranties, expressed or implied, as to the accuracy of the data portrayed on the web sites. Qualitest USA reserves the right to change product information, including pricing information at any time without notice. 

Trademarks and Copyrights:

The WorldofTest.com Qualitest contains trademarked product names. Product names are not to be reproduced or used in any fashion by any party other than Qualitest without the express written consent of Qualitest International Inc.. All pictures, descriptions, and other content of this web site are copyrighted by Qualitest USA and may not be used without the express written permission of Qualitest USA. Purchaser acknowledges that they have no right, title, or interest in the trademarks or copyrights in the products, and purchaser covenants that it will take no action to register or otherwise interfere with such rights. Please contact us with any requests for permission or questions about our trademarks. 

Warranty Disclaimer:

No warranty or affirmation of fact, express or implied, other than expressly set forth herein is made or authorized by Qualitest USA. Qualitest USA disclaims any and all liability for product defect claims. Qualitest USA does not express or imply a warranty that any product on the web site(s) is fit for a particular purpose. Qualitest USA honors the product warranty as published and made available by Qualitest USA. Warranty claims for products not manufactured by Qualitest are the responsibility of the manufacturer. Qualitest USA will always make its best good faith effort to resolve warranty claims. 


Force Majeure:

Qualitest USA shall not be liable for any delay in or impairment of performance resulting in whole or in part from Acts of God, service interruptions, labor disruptions, insurrections, governmental decrees or controls, war risks, severe weather, supplies or raw materials, inability to procure or ship products, inability to obtain permits and/or licenses, or any other circumstances or causes beyond the control of Qualitest USA in the conduct of its business. 

Qualitest USA Privacy Policy 

I. What legal provisions govern our data processing practices? How and from where (internal/external sources) is personal data acquired? What are the rights of the user (web site visitor/registered customer)? 

1. General
As a general principle, no personal details need to be provided when visiting our Internet site. Data made available to us by you is treated in strict confidence and in accordance with the provisions of the Federal Data Protection Act. With a few exceptions (see point 2 below), our web server only registers non-personal (anonymous) data concerning the use of our site. Specifically, the log files of our web server, as a general rule, only contain the user's IP address, the last page visited by the user, the browser used, date, time and the file requested. This anonymous data, however, does not permit conclusions to be drawn about the individual users, and merely serves to prepare statistics on the use of our Internet site for the purpose of its improvement. At the same time, great importance is placed on ensuring that usage data is not linked with personal data. 

2. Personal data

Person-related data (personal data) is only used if the newsletter is ordered (by email), product(s) is (are) ordered, or to supply product information. We undertake to use the personal data entrusted to us only for the purposes stated. Purchase history is retained for assistance with future customer needs. 

II. What security measures are used to protect personal data? What are the user's options for processing personal data? 

3. Technical measures

Databases are optimally protected against third party access, loss, misuse and falsification through the use of appropriate technical means. In order to determine the popularity of individual topic areas, cookies are used in those sections. These text files are stored on your hard disk and facilitate your use of our Internet site. Thanks to these cookies, there is no need for specific registration each time you visit a section requiring registration, and we can supply you with the personalized contents you request. 

It is for you to decide whether you want to work with cookies and, if so, which kind (permanently stored on the hard disk or only placed for the time of the browser activity). However, we draw your attention to the fact that access to fields requiring registration is only possible with activated cookies. 

III. What data is communicated to third parties and for what purposes? 

4. Communication of personal data

Personal data entrusted to us by you is not communicated, leased or sold to third parties. 

IV. Which department answers questions about the processing of personal data? 

5. Contact

In the light of the rapid technical developments in connection with the Internet, we make every effort to constantly improve our Internet site and technical precautions, including those connected with data protection. We will keep you suitably informed about such measures. Any changes will be published here. Further information is available at any time by contacting Qualitest USA.

Disclaimer of liability Qualitest USA shall not be liable for direct, indirect or consequential losses resulting from or in connection with access to, use of or queries to the Qualitest web site or its links with other web sites, even if Qualitest USA has previously been informed of the possibility of such losses. No guarantee is provided as to the accuracy of the information disseminated via the Qualitest USA web site. In addition, Qualitest USA guarantees neither the reliability nor the completeness of the information contained on its web site. The information made available on the Qualitest and WorldofTest.com web site may be amended at any time without prior notice. In particular, Qualitest USA shall not be liable for losses caused by transmission errors, technical faults and interruptions, breakdowns or an unlawful interference with the user's data processing system or the generally accessible systems and transmission networks. Nor shall Qualitest USA be liable for losses resulting from breakdowns, interruptions or overloads occurring to any data processing systems. If certain links are activated on the Qualitest and WorldofTest.com web site, the user may under certain circumstances leave the Qualitest web site. Qualitest USA assumes no responsibility for the contents, products or services offered or other information or offers contained on these linked web sites. 

Related Products