AutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus (Combo EN-ASTM Model)

AutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus (Combo EN-ASTM Model)

Skip to product information
AutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus (Combo EN-ASTM Model)
SKU:

AutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus (Combo EN-ASTM Model)

Get personalized pricing for your specific requirements

AutoVicat-367-EN-ASTM – 8-Station Automatic Vicat Needle Apparatus

The AutoVicat-367-EN-ASTM is an advanced 8-Station Automatic Vicat Needle Apparatus designed for efficient and precise testing of construction materials. This EN-ASTM combination model supports testing procedures based on both European and ASTM standards, providing a versatile solution for cement and related material laboratories.

Featuring programmable test sequences and dedicated data recording software, the system streamlines Vicat testing while improving measurement consistency and laboratory productivity. Its multi-station configuration allows multiple samples to be tested efficiently, while the supplied accessories support complete testing workflows.

With automated operation, computerized data management, and compatibility with EN and ASTM Vicat testing requirements, the AutoVicat-367-EN-ASTM provides a reliable solution for quality control, research, and material testing applications.

AutoVicat-367-EN-ASTM – 8-Station Automatic Vicat Needle Apparatus

The AutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus is designed for automated determination of initial and final setting times of cement and related construction materials. This EN-ASTM combination model supports testing according to EN 196-3, ASTM C191 Method B, and EN 480-2, with the required optional equipment.

The system features eight measuring points arranged in a rectangular trough, allowing multiple samples to be tested within a single setup. Testing can be performed in air or in a constant-temperature water bath. The water-bath configuration can include a heat exchanger and cooler to help maintain the required test temperature.

For EN-based testing, the apparatus supports programmable test sequences, helping streamline automated Vicat penetration measurements. For ASTM testing, samples can be tested in humid air conditions above 95% relative humidity, as required by the applicable procedure.

During operation, the system automatically records the initial setting time, final setting time, and corresponding setting plots. The combined weight of the plunger and Vicat needle is 300 g with a tolerance of ±1 g. After every penetration, the Vicat needle is automatically cleaned, helping maintain consistent testing conditions throughout the sequence.

Key Features

  • 8-station automatic Vicat testing system

  • Supports EN 196-3, ASTM C191 Method B, and EN 480-2

  • Automated measurement of initial and final setting times

  • Automatic recording of setting curves and test data

  • Programmable testing sequences for EN procedures

  • Testing in air or constant-temperature water bath

  • Optional heat exchanger and cooling system for temperature control

  • 300 g ±1 g combined plunger and needle weight

  • Automatic cleaning of the Vicat needle after each penetration

  • Rectangular trough with eight measuring positions

Important Note

A standard PC or laptop is required to operate the equipment and is not included with the apparatus.

For EN 480-2 testing, the following additional equipment is required:

  • Additional weight: 1.0366.10

  • Plunger: 1.0366.12

  • Optional extra cooling unit: 1.0366.13, for maintaining a test temperature of 5°C

Theory and Methodology

The AutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus applies the standard Vicat penetration principle to evaluate how cement or gypsum paste develops resistance to penetration as setting progresses. By automating the penetration sequence and recording measurements digitally, the system helps reduce manual intervention and provides consistent monitoring of the material's transition from a workable paste toward a rigid structure.

Standard Vicat Penetration Theory

Vicat testing determines setting behavior by measuring the penetration of a standardized needle or plunger into a prepared cement paste at controlled time intervals.

  • Initial Setting Time: The point at which the penetration reaches the specified criterion for initial set, indicating that the paste is beginning to lose its plastic and workable characteristics.

  • Final Setting Time: The point at which the penetration reaches the specified final-set criterion, indicating that the material has developed substantially greater structural rigidity.

The applicable requirements of ASTM C191 Method B, EN 196-3, and EN 480-2 define important testing parameters, including specimen preparation, apparatus configuration, environmental conditions, and penetration components. The combined weight of the plunger and Vicat needle is 300 g with a tolerance of ±1 g, according to the applicable setup.

AutoVicat-367-EN-ASTM Method Execution

The AutoVicat-367-EN-ASTM automates the Vicat penetration process through programmed mechanical operation, electronic measurement, and computerized data recording. This approach provides a repeatable testing sequence while reducing the need for continuous manual observation.

Multi-Station Testing Capacity

The system incorporates eight measuring points arranged in a rectangular trough, allowing multiple specimens to be evaluated within one testing setup. The apparatus automatically moves between measuring positions according to the programmed sequence, supporting efficient multi-sample testing.

Automated Needle Penetration

The apparatus controls the penetration process mechanically according to the programmed test sequence. Automated positioning and measurement help maintain consistent testing intervals and reduce variations associated with repeated manual operation.

Automatic Needle Cleaning

After each penetration, the Vicat needle is automatically cleaned before the next measurement. This helps prevent residual cement paste from affecting subsequent penetration measurements and supports consistent test conditions throughout the sequence.

Temperature and Humidity Control

Testing can be performed in air or in a constant-temperature water bath, depending on the applicable procedure and configuration. The water-bath setup can include a heat exchanger and cooling unit for maintaining the required temperature. For ASTM testing, the required humid-air conditions above 95% relative humidity can be provided using the appropriate environmental setup.

Digital Depth and Setting-Time Recording

Electronic measurement and PC-based software allow the system to record penetration data throughout the test. The apparatus automatically determines and records initial setting time, final setting time, and setting plots, providing a digital representation of the material's setting progression for analysis and documentation.

AutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus (Combo EN-ASTM Model)Technical Specifications

Dimensions (W x D x H) 700 x 600 x 600 mm 
Weight 55 kg
Power Supply 110 - 230 V / 50 - 60 Hz
Scope of delivery
  • The Base unit is designed as a table model, including the control unit and standard software for programmable test sequences and data recording.
  • 8 Vicat molds (conical hard plastic rings) measuring 70/80 mm in diameter and 40 mm in height (compliant with EN standards).
  • 8 Vicat molds (conical hard plastic rings) measuring 60/70 mm in diameter and 40 mm in height (compliant with ASTM standards).
  • 8 glass base plates, each with a diameter of 120 mm.
  • 8 centerings for Vicat molds (conical hard plastic rings) measuring 70/80 mm in diameter and 40 mm in height (EN compliant).
  • 8 centerings for Vicat molds (conical hard plastic rings) measuring 60/70 mm in diameter and 40 mm in height (ASTM compliant).
  • 1 pair of cleaning brushes.
  • 1 tee wrench, size 1.25 mm.
  • 1 tee wrench, size 2 mm.
  • 2 spare glass plates, each with a diameter of 120 mm.
  • 2 spare initial-set needles, diameter 1.13 mm (EN).
  • 3 spare initial-set needles, diameter 1.0 mm (ASTM).
  • Coarse filter sponge.
  • Fine filter sponge.
  • Serial cable.
  • Frame for the cover plate.
  • 8 cover plates for generating moist air (ASTM).
  • Hermetic stopper (ASTM).
  • Mud stop sponge (ASTM).
  • Dearerate set hose (ASTM).
  • Humidity sensor cover (ASTM).
  • USB/RS232 adapter.
  • Mains cable.
 

Delivery time varies upon stock availability. Our standard dispatch and shipping times are generally within 1 week, however for some high demand items the delivery may be extended to 2-3 weeks. If you require these items urgently please contact us to check accurate stock availability and to organize faster shipping methods.

🚚

Important Delivery Information

Delivery time varies upon stock availability. Our standard dispatch and shipping times are generally within 1 week, however for some high demand items the delivery may be extended to 2-3 weeks.

Need it urgently? Contact us here to check stock and organize faster shipping.

Orders:
Purchaser acknowledges that when placing an order on the Qualitest:

A. the placing of the order signifies the purchaser's assent to place said order at the Qualitest and that the order will be accepted by the successful processing of the order by Qualitest USA LC.
B. the purchaser typing their name when requested to do so by the Qualitest constitutes a signature to contract
C. the purchaser has the full authority to enter into the contract for such entity, and such grant of authority was indicated by purchaser by placement of the order through the Qualitest.
D. A minimum handling fee will be applied to the shipping total for all orders.

Shipping within the U.S.A.:

All orders will be shipped best way prepaid, via courier for smaller packages or via Freight forwarders for larger crates. A handling fee may be applicable to orders. Title to merchandise transfers to the purchaser upon delivery to the carrier. Loss or damage in transit is the responsibility of the purchaser. Qualitest USA will provide assistance with information needed for processing claims.

Shipping outside of the U.S.A.:

All orders will be shipped best way, via courier for smaller packages or via Freight forwarders for larger crates. A low handling fee may be applicable. Title to merchandise transfers to the purchaser upon delivery to the carrier. Loss or damage in transit is the responsibility of the purchaser. Qualitest USA will provide assistance with information needed for processing claims. Export fees, duties, taxes, and customs clearance are the responsibility of the purchaser.

Shipping insurance is not included, please contact our sales representatives if you need shipping insurance.

Partial shipment: Qualitest USA reserves the right to make partial shipments unless otherwise instructed by the purchaser.

Payment terms: All payments to Qualitest USA are to be made in U.S. Dollars (USD)

A. Credit Card - Qualitest USA will accept Visa, Master Card, AMEX or Discover. Required information from the purchaser is the credit card number, 3 digit security code, expiration date, card holder's name (exactly as it appears on the card), billing address, and valid telephone number for us to use in case of difficulty. Qualitest USA reserves the right to delay shipment pending verification of credit card validity.
B. Wire Transfer - Transfer must be made to Qualitest and confirmed for the full purchase amount (merchandise, handling and shipping) prior to shipment. Please contact us by phone at 1.877.884.TEST (8378)(outside U.S. +1.905.944.9825) or by fax at +1.954.697.8211 for bank information.
C. Open Account - Available to U.S.A. and Canadian customers only. Terms on open accounts are Net 30 days from date of shipment. Qualitest USA reserves the right to refuse shipment of new orders if any unpaid invoices are older than 30 days. Purchasers may apply for an open account by providing:

their bank information
3 credit references from other suppliers
Please allow 5 business days for confirmation of credit and creation of an open account.

Return Policy:

Qualitest USA may accept return of purchased merchandise within North America for refund or credit under the following conditions -

  • There may be an additional restocking fee charged to the transaction if items are already shipped to customer.
  • Goods must be returned to Qualitest USA within 5 days of the date of the receipt of the purchased goods.
  • All freight, duties, customs, and other related shipping charges for the returned merchandise are borne by the purchaser. Shipments made freight collect will be refused.
  • Merchandise must be returned properly packaged in brand new, salable condition, along with original packaging and all documentation, accessories and certificates.
  • Purchaser has confirmed return authorization directly with Qualitest.
  • Merchandise is regular catalog item. Special order items can not be returned.
  • All returned merchandise is subject to inspection by Qualitest. Qualitest reserves the right to refuse return of any merchandise that is used, damaged, or not part of the current published price list. In the case Qualitest does not accept the returned merchandise, reasonable attempts will be made to notify the Buyer and the merchandise will be returned to Buyer as they were received by Qualitest. Damaged merchandise that can be restored to original condition and thus accepted for return will be evaluated on an individual basis. The purchaser will be advised of additional expenses for the repair and restoration of the returned item. After approval, these expenses will be charged to the purchaser in addition to the restocking fee.


Change of Terms:

The acceptance of any order by Qualitest USA is subject to purchaser's assent to all of the terms and conditions set forth herein. Purchaser's assent to these terms and conditions shall be presumed from the purchaser's placement of an order through the Qualitest. Any and all other terms and conditions are expressly rejected, and no addition or modification of terms and conditions shall be binding without the prior agreement of Qualitest USA in writing.

Complete Agreement:

The terms and conditions in the Qualitest web site, incorporated herein by reference, including forms, acknowledgements, quotations, invoices and sales terms and conditions constitute the entire and exclusive agreement between the purchaser and Qualitest USA LC.

Information:

Qualitest USA makes every effort to insure the accuracy of the product information displayed on its web sites, but makes no warranties, expressed or implied, as to the accuracy of the data portrayed on the web sites. Qualitest USA reserves the right to change product information, including pricing information at any time without notice. 

Trademarks and Copyrights:

The WorldofTest.com Qualitest contains trademarked product names. Product names are not to be reproduced or used in any fashion by any party other than Qualitest without the express written consent of Qualitest International Inc.. All pictures, descriptions, and other content of this web site are copyrighted by Qualitest USA and may not be used without the express written permission of Qualitest USA. Purchaser acknowledges that they have no right, title, or interest in the trademarks or copyrights in the products, and purchaser covenants that it will take no action to register or otherwise interfere with such rights. Please contact us with any requests for permission or questions about our trademarks. 

Warranty Disclaimer:

No warranty or affirmation of fact, express or implied, other than expressly set forth herein is made or authorized by Qualitest USA. Qualitest USA disclaims any and all liability for product defect claims. Qualitest USA does not express or imply a warranty that any product on the web site(s) is fit for a particular purpose. Qualitest USA honors the product warranty as published and made available by Qualitest USA. Warranty claims for products not manufactured by Qualitest are the responsibility of the manufacturer. Qualitest USA will always make its best good faith effort to resolve warranty claims. 


Force Majeure:

Qualitest USA shall not be liable for any delay in or impairment of performance resulting in whole or in part from Acts of God, service interruptions, labor disruptions, insurrections, governmental decrees or controls, war risks, severe weather, supplies or raw materials, inability to procure or ship products, inability to obtain permits and/or licenses, or any other circumstances or causes beyond the control of Qualitest USA in the conduct of its business. 

Qualitest USA Privacy Policy 

I. What legal provisions govern our data processing practices? How and from where (internal/external sources) is personal data acquired? What are the rights of the user (web site visitor/registered customer)? 

1. General
As a general principle, no personal details need to be provided when visiting our Internet site. Data made available to us by you is treated in strict confidence and in accordance with the provisions of the Federal Data Protection Act. With a few exceptions (see point 2 below), our web server only registers non-personal (anonymous) data concerning the use of our site. Specifically, the log files of our web server, as a general rule, only contain the user's IP address, the last page visited by the user, the browser used, date, time and the file requested. This anonymous data, however, does not permit conclusions to be drawn about the individual users, and merely serves to prepare statistics on the use of our Internet site for the purpose of its improvement. At the same time, great importance is placed on ensuring that usage data is not linked with personal data. 

2. Personal data

Person-related data (personal data) is only used if the newsletter is ordered (by email), product(s) is (are) ordered, or to supply product information. We undertake to use the personal data entrusted to us only for the purposes stated. Purchase history is retained for assistance with future customer needs. 

II. What security measures are used to protect personal data? What are the user's options for processing personal data? 

3. Technical measures

Databases are optimally protected against third party access, loss, misuse and falsification through the use of appropriate technical means. In order to determine the popularity of individual topic areas, cookies are used in those sections. These text files are stored on your hard disk and facilitate your use of our Internet site. Thanks to these cookies, there is no need for specific registration each time you visit a section requiring registration, and we can supply you with the personalized contents you request. 

It is for you to decide whether you want to work with cookies and, if so, which kind (permanently stored on the hard disk or only placed for the time of the browser activity). However, we draw your attention to the fact that access to fields requiring registration is only possible with activated cookies. 

III. What data is communicated to third parties and for what purposes? 

4. Communication of personal data

Personal data entrusted to us by you is not communicated, leased or sold to third parties. 

IV. Which department answers questions about the processing of personal data? 

5. Contact

In the light of the rapid technical developments in connection with the Internet, we make every effort to constantly improve our Internet site and technical precautions, including those connected with data protection. We will keep you suitably informed about such measures. Any changes will be published here. Further information is available at any time by contacting Qualitest USA.

Disclaimer of liability Qualitest USA shall not be liable for direct, indirect or consequential losses resulting from or in connection with access to, use of or queries to the Qualitest web site or its links with other web sites, even if Qualitest USA has previously been informed of the possibility of such losses. No guarantee is provided as to the accuracy of the information disseminated via the Qualitest USA web site. In addition, Qualitest USA guarantees neither the reliability nor the completeness of the information contained on its web site. The information made available on the Qualitest and WorldofTest.com web site may be amended at any time without prior notice. In particular, Qualitest USA shall not be liable for losses caused by transmission errors, technical faults and interruptions, breakdowns or an unlawful interference with the user's data processing system or the generally accessible systems and transmission networks. Nor shall Qualitest USA be liable for losses resulting from breakdowns, interruptions or overloads occurring to any data processing systems. If certain links are activated on the Qualitest and WorldofTest.com web site, the user may under certain circumstances leave the Qualitest web site. Qualitest USA assumes no responsibility for the contents, products or services offered or other information or offers contained on these linked web sites. 

Related Products