Automatic Melt Flow Indexer (MFI)

Automatic Melt Flow Indexer (MFI)

Skip to product information
Automatic Melt Flow Indexer (MFI)
In Stock
SKU:

Automatic Melt Flow Indexer (MFI)

Get personalized pricing for your specific requirements

Automatic Melt Flow Indexer (MFI) — QualiFi™ 6000A

Flagship Fully Automatic MFI System with Software-Controlled Variable Load and Pneumatic Operation

The QualiFi™ 6000A is a high-performance automatic melt flow indexer designed for advanced laboratories and quality control facilities that require precise automation, strong measurement reliability, and enhanced operational safety in thermoplastic melt flow testing. It features a software-driven weight selection system with variable load capability, complete pneumatic control for sample compaction, residual material extrusion, and barrel cleaning, along with a 10.1-inch high-definition touchscreen interface.

This model delivers both Melt Mass Flow Rate (MFR) and Melt Volume Flow Rate (MVR) testing across a broad operating range of 50–450 °C, supporting flow measurements from 0.1–100 g/10 min (MFR) and 0.01–3,000 cm³/10 min (MVR). This extensive range represents the widest testing capability within the QualiFi™ melt flow indexer series.

Positioned at the top of the QualiFi™ lineup, the 6000A stands apart from the 4000A and 5000A models through its software-controlled multi-weight selection system with variable load functionality, enabling fully programmable multi-stage load changes within a single test cycle. Automatic weight lifting and lowering, pneumatic sample handling and cleaning, a built-in safety guard for weight control, and a protective barrier between the furnace and loading system collectively reduce manual intervention and improve consistency throughout testing—from sample loading to final data export.

The QualiFi™ 6000A has been part of CNAS inter-laboratory proficiency testing programs for several consecutive years, consistently achieving Z-scores within the ±0.11 range. These results reflect highly stable measurement performance aligned with internationally recognized reference standards.

Automatic Melt Flow Indexer (MFI) — QualiFi™ 6000A Applications

The QualiFi™ 6000A melt flow indexer is designed for quality control, research and development, and incoming material inspection workflows in any laboratory or industrial setting where thermoplastic melt flow properties are a key specification or process control parameter.

Plastic Raw Material Production & Quality Control

Used for incoming raw material inspection, batch consistency checks, and production quality monitoring in polymer manufacturing environments. The software-driven variable load system and 8-group stored test program capability allow quick switching between test conditions for different resin grades without repeated manual setup. This supports efficient, high-throughput testing where melt flow index is a critical acceptance parameter.

Engineering Plastics Testing

Suitable for melt flow measurement of high-temperature engineering polymers such as polycarbonate (PC), polyamide (PA), fluoropolymers, and polyoxymethylene (POM), operating across a full 50–450 °C range. Independent multi-zone temperature control with ±0.1 °C stability ensures consistent thermal conditions required for accurate testing of advanced engineering materials.

Polyolefin & Commodity Polymer Testing

Provides reliable MFR and MVR measurement for polyethylene (PE), polypropylene (PP), polystyrene (PS), ABS, and similar thermoplastics under standard testing conditions. Automated weight handling and software-based load selection reduce manual steps and help maintain consistency in routine melt flow index testing.

Pharmaceutical & Medical-Grade Polymer Testing

Supports melt flow evaluation of medical and pharmaceutical-grade polymers used in regulated applications. Built-in user access control, 5,000-test USB data storage, DMS data management software, and optional PC connectivity enable structured data handling and traceable documentation for compliance requirements.

Petrochemical Industry & Refinery QC

Used for verifying polymer consistency in petrochemical production and refinery environments where stable melt flow behavior is essential for downstream processing. The corrosion-resistant surface treatment and reinforced aluminum structure support long-term operation in demanding laboratory conditions.

Research Institutions & Universities

Ideal for academic research, polymer development studies, and comparative melt flow analysis. The system supports both MVR-based and calculated MFR methods, enabling direct comparison between measurement approaches for advanced material characterization studies.

Commodity Inspection & Certification Laboratories

Applied in third-party testing, certification, and regulatory compliance environments. Alignment with ISO 1133 and ASTM D1238 standards, combined with CNAS proficiency testing history and CE certification, ensures suitability for accredited laboratories requiring traceable and standardized melt flow measurements.

Standards Compliance

The QualiFi™ 6000A melt flow indexer is engineered and manufactured in accordance with internationally recognized standards governing thermoplastic melt flow testing, laboratory instrument safety, and electromagnetic compatibility.

ISO 1133
Plastics — Determination of melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics. This serves as the primary international standard defining test procedures, measurement principles, and performance expectations for melt flow index testing systems.

ASTM D1238
Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer. This is the key North American reference standard for MFR and MVR determination and defines operational procedures for melt flow index instruments.

EN 61010-1:2010+A1:2019
Safety requirements for electrical equipment used in measurement, control, and laboratory environments. This standard supports CE compliance for electrical and operational safety in laboratory instruments.

EN 61326-1:2013
Electromagnetic compatibility requirements for measurement, control, and laboratory equipment. Ensures stable performance of the instrument in environments with electromagnetic interference.

CE Marking
The QualiFi™ 6000A carries CE marking, confirming compliance with applicable European Union directives for safety, health, and environmental protection requirements related to laboratory measurement and control equipment.

Certifications & Proficiency Verification

The QualiFi™ 6000SA is built on the validated QualiFi™ Series platform and shares the same certification framework and performance verification standards applied across the product family, including CE compliance and CNAS inter-laboratory testing participation.

CE Certification
Complies with EN 61010-1:2010+A1:2019 (Low Voltage Directive) and EN 61326-1:2013 (Electromagnetic Compatibility). Conformity is verified through ECM Certificate of Compliance, confirming adherence to essential safety and EMC requirements for laboratory measurement equipment.

CNAS Proficiency Testing
Participates in consecutive CNAS inter-laboratory proficiency testing programs with consistently satisfactory outcomes. Recorded Z-scores remain within −0.07 to +0.11 across all evaluation rounds, demonstrating stable measurement performance and strong inter-laboratory comparability.

Technical Patents
The QualiFi™ Series incorporates multiple registered patents covering key innovations in measurement technology, thermal control systems, and instrument design architecture, supporting enhanced testing precision and operational reliability.

Automatic Melt Flow Indexer (MFI) — QualiFi™ 6000A Key Features

Instrument Design & Construction

The QualiFi™ 6000A is engineered with a focus on durability, operational safety, and efficient laboratory ergonomics, making it suitable for both intensive quality control and research environments.

All-Aluminum Body with Advanced Surface Treatment
The instrument is built on a full aluminum structure with enhanced surface finishing technology, delivering strong mechanical durability and resistance to corrosion, including salt spray conditions. This construction supports stable performance in demanding laboratory and production quality control settings.

Trapezoidal Barrel Design with 15° Tilt
An innovative trapezoidal barrel layout combined with a 15° inclined body and upper rotating mechanism ensures a compact system footprint while improving workflow accessibility. This ergonomic design allows easier access for sample loading and operation, optimizing space efficiency in laboratory setups.

Integrated Thermal Insulation System
The unit incorporates eco-conscious, molded thermal insulation integrated into the structure. This design improves heat retention within the furnace, stabilizes temperature conditions and contributes to reduced energy consumption during continuous operation.

Movable Protective Safety Cover
A movable protective barrier positioned between the furnace and loading assembly enhances operational safety during weight handling and sample loading. This feature reduces exposure to high-temperature zones and supports safer, controlled test execution throughout the workflow.

Software-Controlled Variable Load System

The QualiFi™ 6000A features an advanced software-driven load management system designed to deliver fully automated, highly repeatable melt flow testing with minimal operator involvement. This system is a core differentiator of the model within the QualiFi™ Series.

Software-Controlled Multi-Weight Selection with Variable Load Function
The instrument uses a software-managed multi-weight selection system with variable load capability, allowing fully programmable load changes during a single test cycle. This eliminates dependence on preset manual configurations and supports more flexible, condition-specific testing workflows.

Automatic Weight Handling System
Weights are lifted and lowered automatically through a motorized control system, removing the need for manual weight handling. This reduces operator exposure to high-temperature components and helps eliminate load sequencing errors, improving overall test consistency and repeatability.

Integrated Weight Safety Guard
A built-in weight safety guard is included as standard to prevent unintended weight drop events during automatic load transitions. This enhances operational safety and ensures stable load control throughout the testing process.

Dual Preloading Modes
The system supports two preloading configurations for flexible testing setup:

  • Calibration Weight Load: 0.325–21.6 kg range for standard calibration procedures
  • Additional Load: 10–50 kg adjustable range for extended test conditions

These adjustable settings enable precise reproduction of test conditions across different materials and standards, supporting consistent and traceable measurement results.

Pneumatic Automation System

The QualiFi™ 6000A integrates a fully pneumatic control system to ensure consistent specimen preparation, efficient workflow transitions, and improved operational safety across melt flow testing procedures.

Pneumatic Compaction with Adjustable Load Control
Pneumatic compaction operates with adjustable force settings (10–50 kg) and configurable compaction time, ensuring uniform specimen packing. This removes operator-dependent variability and supports consistent sample preparation conditions across repeated tests.

Pneumatic Residual Material Extrusion
An automated pneumatic extrusion function applies adjustable load (10–50 kg) to efficiently purge residual material from the barrel after testing. This enables rapid transition between samples while maintaining repeatable cleaning performance.

Pneumatic Barrel Cleaning System
The system includes pneumatic-assisted barrel cleaning to standardize inter-test preparation. This eliminates manual brushing, reduces contamination risk, and ensures consistent cleaning efficiency between consecutive tests.

Air Supply Requirement
The system operates with a compressed air requirement of >0.6 MPa, ensuring stable pneumatic performance for compaction, extrusion, and cleaning functions throughout the testing cycle.

Temperature Control

  • Full operating range of 50–450 °C, enabling testing from commodity plastics to high-temperature engineering polymers on a single melt flow index tester platform.
    Multi-stage independent temperature control with dynamic heat distribution ensures a temperature gradient within ≤±0.1 °C along the barrel above the die.
  • Temperature indication error is ≤0.2 °C, with temperature fluctuation maintained within ≤±0.2 °C, and a fine temperature resolution of 0.01 °C for precise control.
  • Temperature recovery after specimen loading is ≤2 minutes, helping reduce overall cycle time in high-throughput melt flow index testing workflows.
  • An intelligent dual PID control algorithm ensures fast heating response, stable temperature rise, and consistent thermal recovery throughout operation.

Measurement Performance

  • MFR measurement range: 0.1–100 g/10 min; MVR measurement range: 0.01–3,000 cm³/10 min — one of the widest measurement ranges available in the melt flow indexer category, enabling accurate testing across very low to very high flow thermoplastics.
  • Piston displacement indication error: ±0.02 mm; displacement resolution: 0.002 mm, ensuring highly precise piston movement tracking during measurement cycles.
  • Timer resolution: 0.0005 seconds — the finest timing resolution in the QualiFi™ melt flow indexer series, supporting highly accurate flow rate calculations.
  • Die plug device based on a lever principle, extending the measurable range up to 3,000 cm³/10 min while preventing barrel leakage during high-flow testing conditions.

Control Software & Data Management

  • Menu-guided 10.1-inch full HD color touchscreen interface with real-time temperature–time curve and MVR curve visualization, providing clear monitoring of testing conditions and flow behavior during operation.
  • Mass method, Volume Method A, and Volume Method B testing are fully supported, with automatic ISO/ASTM effective interval identification and automatic test start for standardized workflow execution.
  • 8 stored test plan groups enable fast setup across multiple materials and specifications, improving efficiency in multi-material quality control environments.
  • The volume method automatically calculates MFR values from the input specimen mass, allowing direct comparison with mass method results for consistent data validation.
  • 5,000-group USB flash storage capacity and integrated DMS data management software support data export, analysis, and structured report generation. Optional PC software enables two-way control between PC and touchscreen, with direct upload to external databases and information systems.
  • Multi-language interface support includes English, French, German, Italian, Russian, and additional languages for broader usability in global laboratories.
  • A user authority management system with role-based access control protects measurement data and helps prevent operational errors.
  • Optional CNAS-validated inter-laboratory proficiency testing records demonstrate performance consistency, with Z-scores maintained within ±0.11 across evaluations.

Accessories & Safety

  • Adjustable metal observation mirror with 15° free-angle adjustment, explosion-proof and shatter-resistant design, and switchable viewing angles for clear monitoring of sample extrusion during testing.
  • Cutting segment collection box prevents fragment contamination of cut-off samples, helping maintain test integrity and result accuracy.
  • Stacking accessory support provides organized placement and easy access to all standard accessories during operation, improving workflow efficiency.
  • Standard accessory set includes: barrel, piston rod, guide bush, weight tray and cover, Φ2.095 mm die, barrel cleaning rod, feeding rod, die cleaning rod, cutter, funnel, special tweezers, USB flash drive, wrenches, power cable, and PC software.

Theory and Method

Extrusion Plastometry — MFR and MVR Determination
The QualiFi™ 6000A operates based on the extrusion plastometry principle defined in ISO 1133 and ASTM D1238. A thermoplastic resin sample is introduced into a heated cylindrical barrel and brought to a controlled test temperature under defined preheating conditions. A specified dead-weight load is then applied through a piston, forcing the molten polymer through a precision-engineered die at the base of the barrel.

The melt flow indexer determines either the mass of extrudate collected over set time intervals (Mass Method, Method A: MFR expressed in g/10 min) or piston displacement over time intervals (Volume Method, Method B: MVR expressed in cm³/10 min), enabling evaluation of flow resistance under standardized conditions.

The melt flow index is inversely related to polymer viscosity under test conditions. Higher MFR or MVR values indicate lower melt viscosity and easier flow, while lower values reflect higher viscosity and greater flow resistance. This makes melt flow index a key parameter for quality control, batch consistency evaluation, molecular weight distribution screening, and process verification across thermoplastic materials.

Software-Controlled Variable Load System
A defining feature of the QualiFi™ 6000A within the QualiFi™ melt flow indexer range is its software-driven weight selection system with variable load functionality. Instead of manual weight selection or fixed configurations, test loads are fully programmed through software. The system automatically selects, lifts, and lowers required weights, including multi-stage load variation within a single test cycle, without manual intervention. This removes errors related to incorrect weight selection, handling contamination, and load sequencing inconsistencies in multi-step testing protocols.

Multi-Stage Independent Temperature Control with Dual PID Algorithm
Temperature control is managed by a high-performance heating and sensing system designed for continuous operation across 50–450 °C. Multi-stage independent control ensures dynamic heat distribution along the barrel, maintaining a temperature gradient of ≤±0.1 °C above the die.

Temperature indication error is ≤0.2 °C, with fluctuation maintained within ≤±0.2 °C. The dual PID control algorithm enables rapid heating response and stable recovery, achieving temperature stabilization within less than 2 minutes after sample loading, significantly improving overall test cycle efficiency.

High-Precision Displacement Measurement
Piston displacement used in MVR calculations is measured using a high-precision system with an indication error of ±0.02 mm and a resolution of 0.002 mm. The timer resolution of 0.0005 seconds enables highly accurate measurement of short interval cut-off sequences, supporting high-flow materials and extended measurement ranges up to 3,000 cm³/10 min.

Pneumatic Operation — Compaction, Residual Extrusion, and Barrel Cleaning
The system integrates pneumatic automation across three key stages of the workflow.
Pneumatic compaction applies adjustable force and time (10–50 kg) to ensure uniform specimen packing, eliminating variability associated with manual compaction.
Pneumatic residual extrusion uses adjustable load (10–50 kg) to rapidly purge remaining material from the barrel after testing, improving turnaround efficiency.
Pneumatic barrel cleaning enables fast, consistent cleaning without manual intervention, reducing contamination risk and improving repeatability.

Preloading and Preheating Modes
The QualiFi™ 6000A supports two preloading modes: calibration weight load (0.325–21.6 kg) and additional load (10–50 kg), both adjustable for accurate reproduction of test conditions across different materials. Two preheating modes (no-load and loaded) provide flexibility for various polymer types and testing protocols, supporting diverse laboratory requirements on a single platform.

Measurement and Control Software
The onboard software supports Mass Method (Method A), Volume Method A, and Volume Method B testing in full compliance with ISO 1133 and ASTM D1238 standards. It automatically identifies effective test intervals and initiates measurements at the correct piston position without operator input, ensuring standardized operation.

Eight stored test plan groups allow pre-configuration of complete test parameters for different materials, reducing setup time and improving efficiency in multi-material testing environments. Real-time temperature–time curves and MVR flow curves displayed on the 10.1-inch touchscreen enable continuous monitoring of thermal stability and test repeatability throughout operation.

Automatic Melt Flow Indexer (MFI) — QualiFi™ 6000A Technical Specifications

Parameter QualiFi™ 6000A
Measurement Methods MFR (Mass Method) / MVR (Volume Method A & B)
MFR Measurement Range 0.1–100 g/10 min
MVR Measurement Range 0.01–3,000 cm³/10 min
Display Full-color 10.1-inch HD touch screen
Cutting Method Automatic
Timer Resolution (s) 0.0005
Temperature Control Range (°C) 50–450 °C
Temperature Resolution (°C) 0.01 °C
Temperature Indication Error ≤0.2 °C
Temperature Fluctuation ≤±0.2 °C
Temperature Gradient above Die (0–75 mm) ≤±0.3 °C
Temperature Recovery Time after Loading ≤2 minutes
Loading Mode Electric (automatic weight lifting/lowering)
Weight Selection System Software-controlled; multi-weight set with variable load function
Preload Range — Calibration Weight Mode (kg) 0.325–21.6 kg
Preload Range — Additional Load Mode (kg) 10–50 kg
Compaction Load Range (kg) 10–50 kg — pneumatic
Residual Material Extrusion Load Range (kg) 10–50 kg — pneumatic
Piston Displacement Indication Error (mm) ±0.02 mm
Piston Displacement Display Resolution (mm) 0.002 mm
Voltage 220V AC (-15% to +10%), 50 Hz, 0.5 kVA (110V is also available)
Air Source Requirement >0.6 MPa
Dimensions W×D×H (mm) 600×500×1,450 mm
Weight (kg) 120 kg
Data Storage 5,000 test groups (USB flash drive)
Software DMS data management software; optional PC two-way control software
Interface Languages English, French, German, Italian, Russian, and others
Certifications CE (EN 61010-1, EN 61326-1); CNAS inter-laboratory proficiency testing — satisfactory

Standard Accessory Configuration

Item Quantity
Main unit (including 1 barrel) 1 set
Basic weight set (piston rod, guide bush, weight tray, weight cover) 1 set
Die Φ2.095 mm 1 piece
Barrel cleaning rod 1 piece
Feeding rod 1 piece
Die cleaning rod 1 piece
Automatic cutter 1 piece
Funnel 1 piece
Level 1 piece
Special tweezers 2 pieces
Fuse 2 pieces
Hexagon wrench (2 mm) 1 piece
Fixed wrench (8–10 mm) 1 piece
USB flash drive 1 piece
Power cable 1 piece
PC software 1 set

Optional Accessories

Item Description
Sample Forming Machine Compression pre-forming device for powder, flake, film fragment, or granule specimens prior to MFR/MVR testing — particularly useful for materials that cannot be loaded directly into the melt flow indexer barrel

Delivery time varies upon stock availability. Our standard dispatch and shipping times are generally within 1 week, however for some high demand items the delivery may be extended to 2-3 weeks. If you require these items urgently please contact us to check accurate stock availability and to organize faster shipping methods.

🚚

Important Delivery Information

Delivery time varies upon stock availability. Our standard dispatch and shipping times are generally within 1 week, however for some high demand items the delivery may be extended to 2-3 weeks.

Need it urgently? Contact us here to check stock and organize faster shipping.

Orders:
Purchaser acknowledges that when placing an order on the Qualitest:

A. the placing of the order signifies the purchaser's assent to place said order at the Qualitest and that the order will be accepted by the successful processing of the order by Qualitest USA LC.
B. the purchaser typing their name when requested to do so by the Qualitest constitutes a signature to contract
C. the purchaser has the full authority to enter into the contract for such entity, and such grant of authority was indicated by purchaser by placement of the order through the Qualitest.
D. A minimum handling fee will be applied to the shipping total for all orders.

Shipping within the U.S.A.:

All orders will be shipped best way prepaid, via courier for smaller packages or via Freight forwarders for larger crates. A handling fee may be applicable to orders. Title to merchandise transfers to the purchaser upon delivery to the carrier. Loss or damage in transit is the responsibility of the purchaser. Qualitest USA will provide assistance with information needed for processing claims.

Shipping outside of the U.S.A.:

All orders will be shipped best way, via courier for smaller packages or via Freight forwarders for larger crates. A low handling fee may be applicable. Title to merchandise transfers to the purchaser upon delivery to the carrier. Loss or damage in transit is the responsibility of the purchaser. Qualitest USA will provide assistance with information needed for processing claims. Export fees, duties, taxes, and customs clearance are the responsibility of the purchaser.

Shipping insurance is not included, please contact our sales representatives if you need shipping insurance.

Partial shipment: Qualitest USA reserves the right to make partial shipments unless otherwise instructed by the purchaser.

Payment terms: All payments to Qualitest USA are to be made in U.S. Dollars (USD)

A. Credit Card - Qualitest USA will accept Visa, Master Card, AMEX or Discover. Required information from the purchaser is the credit card number, 3 digit security code, expiration date, card holder's name (exactly as it appears on the card), billing address, and valid telephone number for us to use in case of difficulty. Qualitest USA reserves the right to delay shipment pending verification of credit card validity.
B. Wire Transfer - Transfer must be made to Qualitest and confirmed for the full purchase amount (merchandise, handling and shipping) prior to shipment. Please contact us by phone at 1.877.884.TEST (8378)(outside U.S. +1.905.944.9825) or by fax at +1.954.697.8211 for bank information.
C. Open Account - Available to U.S.A. and Canadian customers only. Terms on open accounts are Net 30 days from date of shipment. Qualitest USA reserves the right to refuse shipment of new orders if any unpaid invoices are older than 30 days. Purchasers may apply for an open account by providing:

their bank information
3 credit references from other suppliers
Please allow 5 business days for confirmation of credit and creation of an open account.

Return Policy:

Qualitest USA may accept return of purchased merchandise within North America for refund or credit under the following conditions -

  • There may be an additional restocking fee charged to the transaction if items are already shipped to customer.
  • Goods must be returned to Qualitest USA within 5 days of the date of the receipt of the purchased goods.
  • All freight, duties, customs, and other related shipping charges for the returned merchandise are borne by the purchaser. Shipments made freight collect will be refused.
  • Merchandise must be returned properly packaged in brand new, salable condition, along with original packaging and all documentation, accessories and certificates.
  • Purchaser has confirmed return authorization directly with Qualitest.
  • Merchandise is regular catalog item. Special order items can not be returned.
  • All returned merchandise is subject to inspection by Qualitest. Qualitest reserves the right to refuse return of any merchandise that is used, damaged, or not part of the current published price list. In the case Qualitest does not accept the returned merchandise, reasonable attempts will be made to notify the Buyer and the merchandise will be returned to Buyer as they were received by Qualitest. Damaged merchandise that can be restored to original condition and thus accepted for return will be evaluated on an individual basis. The purchaser will be advised of additional expenses for the repair and restoration of the returned item. After approval, these expenses will be charged to the purchaser in addition to the restocking fee.


Change of Terms:

The acceptance of any order by Qualitest USA is subject to purchaser's assent to all of the terms and conditions set forth herein. Purchaser's assent to these terms and conditions shall be presumed from the purchaser's placement of an order through the Qualitest. Any and all other terms and conditions are expressly rejected, and no addition or modification of terms and conditions shall be binding without the prior agreement of Qualitest USA in writing.

Complete Agreement:

The terms and conditions in the Qualitest web site, incorporated herein by reference, including forms, acknowledgements, quotations, invoices and sales terms and conditions constitute the entire and exclusive agreement between the purchaser and Qualitest USA LC.

Information:

Qualitest USA makes every effort to insure the accuracy of the product information displayed on its web sites, but makes no warranties, expressed or implied, as to the accuracy of the data portrayed on the web sites. Qualitest USA reserves the right to change product information, including pricing information at any time without notice. 

Trademarks and Copyrights:

The WorldofTest.com Qualitest contains trademarked product names. Product names are not to be reproduced or used in any fashion by any party other than Qualitest without the express written consent of Qualitest International Inc.. All pictures, descriptions, and other content of this web site are copyrighted by Qualitest USA and may not be used without the express written permission of Qualitest USA. Purchaser acknowledges that they have no right, title, or interest in the trademarks or copyrights in the products, and purchaser covenants that it will take no action to register or otherwise interfere with such rights. Please contact us with any requests for permission or questions about our trademarks. 

Warranty Disclaimer:

No warranty or affirmation of fact, express or implied, other than expressly set forth herein is made or authorized by Qualitest USA. Qualitest USA disclaims any and all liability for product defect claims. Qualitest USA does not express or imply a warranty that any product on the web site(s) is fit for a particular purpose. Qualitest USA honors the product warranty as published and made available by Qualitest USA. Warranty claims for products not manufactured by Qualitest are the responsibility of the manufacturer. Qualitest USA will always make its best good faith effort to resolve warranty claims. 


Force Majeure:

Qualitest USA shall not be liable for any delay in or impairment of performance resulting in whole or in part from Acts of God, service interruptions, labor disruptions, insurrections, governmental decrees or controls, war risks, severe weather, supplies or raw materials, inability to procure or ship products, inability to obtain permits and/or licenses, or any other circumstances or causes beyond the control of Qualitest USA in the conduct of its business. 

Qualitest USA Privacy Policy 

I. What legal provisions govern our data processing practices? How and from where (internal/external sources) is personal data acquired? What are the rights of the user (web site visitor/registered customer)? 

1. General
As a general principle, no personal details need to be provided when visiting our Internet site. Data made available to us by you is treated in strict confidence and in accordance with the provisions of the Federal Data Protection Act. With a few exceptions (see point 2 below), our web server only registers non-personal (anonymous) data concerning the use of our site. Specifically, the log files of our web server, as a general rule, only contain the user's IP address, the last page visited by the user, the browser used, date, time and the file requested. This anonymous data, however, does not permit conclusions to be drawn about the individual users, and merely serves to prepare statistics on the use of our Internet site for the purpose of its improvement. At the same time, great importance is placed on ensuring that usage data is not linked with personal data. 

2. Personal data

Person-related data (personal data) is only used if the newsletter is ordered (by email), product(s) is (are) ordered, or to supply product information. We undertake to use the personal data entrusted to us only for the purposes stated. Purchase history is retained for assistance with future customer needs. 

II. What security measures are used to protect personal data? What are the user's options for processing personal data? 

3. Technical measures

Databases are optimally protected against third party access, loss, misuse and falsification through the use of appropriate technical means. In order to determine the popularity of individual topic areas, cookies are used in those sections. These text files are stored on your hard disk and facilitate your use of our Internet site. Thanks to these cookies, there is no need for specific registration each time you visit a section requiring registration, and we can supply you with the personalized contents you request. 

It is for you to decide whether you want to work with cookies and, if so, which kind (permanently stored on the hard disk or only placed for the time of the browser activity). However, we draw your attention to the fact that access to fields requiring registration is only possible with activated cookies. 

III. What data is communicated to third parties and for what purposes? 

4. Communication of personal data

Personal data entrusted to us by you is not communicated, leased or sold to third parties. 

IV. Which department answers questions about the processing of personal data? 

5. Contact

In the light of the rapid technical developments in connection with the Internet, we make every effort to constantly improve our Internet site and technical precautions, including those connected with data protection. We will keep you suitably informed about such measures. Any changes will be published here. Further information is available at any time by contacting Qualitest USA.

Disclaimer of liability Qualitest USA shall not be liable for direct, indirect or consequential losses resulting from or in connection with access to, use of or queries to the Qualitest web site or its links with other web sites, even if Qualitest USA has previously been informed of the possibility of such losses. No guarantee is provided as to the accuracy of the information disseminated via the Qualitest USA web site. In addition, Qualitest USA guarantees neither the reliability nor the completeness of the information contained on its web site. The information made available on the Qualitest and WorldofTest.com web site may be amended at any time without prior notice. In particular, Qualitest USA shall not be liable for losses caused by transmission errors, technical faults and interruptions, breakdowns or an unlawful interference with the user's data processing system or the generally accessible systems and transmission networks. Nor shall Qualitest USA be liable for losses resulting from breakdowns, interruptions or overloads occurring to any data processing systems. If certain links are activated on the Qualitest and WorldofTest.com web site, the user may under certain circumstances leave the Qualitest web site. Qualitest USA assumes no responsibility for the contents, products or services offered or other information or offers contained on these linked web sites. 