Portable Ferrograph Analyzer

Portable Ferrograph Analyzer

Skip to product information
Portable Ferrograph Analyzer
SKU:

Portable Ferrograph Analyzer

The QualiFG™ Port is a compact, field-ready portable ferrograph analyzer engineered for rapid wear debris assessment in lubricating oil. Designed for maintenance and condition monitoring teams, it combines electromagnetic particle capture with neural-network image recognition to deliver automated wear classification, trend analysis, and structured reporting directly at the asset location.

  • 6× Optical Magnification, 5 MP CMOS Camera
  • 256-Level Adjustable Magnetic Field Control
  • 4 Automated Wear-Type Classification Outputs
  • Sub-1-Minute Detection With Auto Injection And Cleaning

Get personalized pricing for your specific requirements

Portable Ferrograph Analyzer – QualiFG™ Port

The Portable Ferrograph Analyzer QualiFG™ Port is a compact, field-ready ferrograph system engineered for rapid assessment of ferromagnetic wear debris in lubricating oil. It integrates electromagnetic particle capture with advanced image-recognition capabilities, enabling on-device wear particle imaging, classification of wear patterns, and generation of maintenance-oriented reports within a unified workflow.

Designed for reliability and condition monitoring teams, this portable solution supports fast screening directly at the asset location, eliminating the delay associated with full laboratory ferrography procedures. The system supports automated sample injection, automated cleaning cycles, trend monitoring, early-stage fault alerts, and report generation, all within a rugged portable enclosure suitable for onsite operation.

QualiFG™ Port is well-suited for field inspections, route-based oil analysis, and rapid condition evaluation tasks where immediate wear debris insights are critical. It helps maintenance teams identify developing issues earlier, supporting informed decisions before equipment degradation progresses into serious failure conditions.

Portable Ferrograph Analyzer – QualiFG™ Port Applications

Field screening for rotating equipment:
QualiFG™ Port is well-suited for rapid on-site evaluation of ferromagnetic wear debris in gearboxes, bearings, hydraulic units, and circulating oil systems. Its short analysis cycle allows maintenance teams to quickly determine whether equipment is operating normally or showing early signs of abnormal wear that require further inspection.

Trend monitoring and early warning:
This Ferrograph analyzer supports condition-based maintenance through historical data review, wear trend tracking, and particle concentration analysis. It enables operators to observe gradual changes in machine health, making it valuable for maintenance strategies focused on long-term performance patterns rather than single-point results.

Wear-type classification for maintenance decisions:
QualiFG™ Port categorizes ferromagnetic wear particles into key types, including abrasive wear particles, adhesive wear particles, sliding wear particles, and cutting wear particles. This classification enhances diagnostic clarity, helping maintenance teams interpret wear behavior more effectively and prioritize corrective actions.

Reporting and maintenance documentation:
The system is designed to support structured reporting needs across maintenance teams. It offers data review, export functions, wear condition evaluation, and maintenance guidance outputs, making it easier to maintain consistent inspection records across multiple sites and operational teams.

Standards

ASTM D7690 – Provides guidance for the microscopic characterization of wear and contaminant particles deposited on ferrograms. It is commonly referenced in ferrogram microscopy workflows for consistent particle evaluation and analysis practices.

ASTM D7684 – Establishes terminology and classification guidance for microscopic particle identification programs. It supports standardized description of wear particles, helping ensure consistent reporting and interpretation across oil analysis and condition monitoring systems.

Portable Ferrograph Analyzer – QualiFG™ Port Key Features

Portable field-ready design:
QualiFG™ Port features a compact, lightweight structure designed for onsite condition monitoring. Its form factor supports field-based screening, making it suitable for inspections outside traditional laboratory environments.

Electromagnetic adsorption and image recognition:
The system integrates electromagnetic particle capture with image-recognition technology to detect ferromagnetic wear debris in lubricating oil. This combined approach forms the core mechanism for particle detection and analysis.

High-definition optical imaging:
Equipped with 6× optical magnification and a 5 MP CMOS industrial camera (2592 × 1944 resolution), the system delivers detailed wear particle imaging. This level of clarity supports automated classification and structured reporting.

Reflective LED illumination:
An LED reflective lighting system enhances visibility of particle surface texture and coloration during imaging, improving consistency in wear particle evaluation.

Adjustable magnetic field control:
The magnetic field intensity can be adjusted across 256 levels, allowing flexible configuration for varying sample conditions and wear debris concentrations.

Automatic sample injection and cleaning:
The instrument includes automated sample injection and cleaning functions. Cleaning performance can be monitored through the software, with configurable sampling and cleaning durations for operational control.

Four wear-type outputs:
QualiFG™ Port categorizes wear particles into four groups: abrasive wear particles, adhesive wear particles, sliding wear particles, and cutting wear particles. This supports clearer interpretation of wear conditions beyond basic detection.

Automated reporting and trend analysis:
The software provides historical data review, trend analysis, wear particle statistics, and automated report generation with condition evaluation and maintenance guidance. This helps standardize documentation for condition monitoring programs.

Theory and Method

A Ferrograph screening system of this type operates by capturing ferromagnetic wear particles from a lubricating oil sample and analyzing them through optical imaging combined with software-based recognition. In QualiFG™ Port, electromagnetic adsorption draws ferromagnetic particles onto the inner surface of the detection cell, where they are arranged for optical inspection and digital analysis.

Once deposited, the particles are recorded by the optical imaging system, and the resulting images are processed using image-recognition techniques to assess particle size, shape, and wear characteristics. QualiFG™ Port applies a neural-network-based analysis approach to support real-time evaluation of particle morphology and dimensional features, enabling automated interpretation and structured reporting from the same dataset.

This approach is designed for rapid wear screening rather than full laboratory ferrogram microscopy. In practical use, it functions as an early-warning and trend-monitoring tool, helping maintenance teams identify abnormal wear patterns and determine when more detailed oil analysis or maintenance action is required.

Portable Ferrograph Analyzer – QualiFG™ Port Technical Specification

Parameter QualiFG™ Port
Product Type Portable Ferrograph Analyzer / Ferrograph
Detection Principle Electromagnetic adsorption + image recognition
Detection Target Ferromagnetic particles in lubricating oil
Detection Range 5–500 μm
Optical Magnification
Camera 5 MP CMOS industrial camera
Camera Resolution 2592 × 1944
Light Source LED reflective light source
Wear Type Output Normal abrasive, adhesive wear, sliding wear, cutting wear
Output Indicators Total wear amount, large/small particle counts, equivalent circle radius, major axis dimension, wear evaluation
Detection Duration Less than 1 minute
Display 12.1-inch, 1280 × 800 color LCD touchscreen
CPU 8-core 64-bit processor; 4 Cortex-A76 + 4 Cortex-A55
GPU ARM Mali-G610
NPU Up to 6 TOPS
Memory 16 GB RAM
Storage 256 GB eMMC
Ports USB / RJ45
Working Temperature -20°C to 60°C
Power DC 24 V or power adapter
Maximum Power Less than 100 W
Materials PP + aluminum alloy
Weight 10 ± 0.2 kg

Delivery time varies upon stock availability. Our standard dispatch and shipping times are generally within 1 week, however for some high demand items the delivery may be extended to 2-3 weeks. If you require these items urgently please contact us to check accurate stock availability and to organize faster shipping methods.

🚚

Important Delivery Information

Delivery time varies upon stock availability. Our standard dispatch and shipping times are generally within 1 week, however for some high demand items the delivery may be extended to 2-3 weeks.

Need it urgently? Contact us here to check stock and organize faster shipping.

Orders:
Purchaser acknowledges that when placing an order on the Qualitest:

A. the placing of the order signifies the purchaser's assent to place said order at the Qualitest and that the order will be accepted by the successful processing of the order by Qualitest USA LC.
B. the purchaser typing their name when requested to do so by the Qualitest constitutes a signature to contract
C. the purchaser has the full authority to enter into the contract for such entity, and such grant of authority was indicated by purchaser by placement of the order through the Qualitest.
D. A minimum handling fee will be applied to the shipping total for all orders.

Shipping within the U.S.A.:

All orders will be shipped best way prepaid, via courier for smaller packages or via Freight forwarders for larger crates. A handling fee may be applicable to orders. Title to merchandise transfers to the purchaser upon delivery to the carrier. Loss or damage in transit is the responsibility of the purchaser. Qualitest USA will provide assistance with information needed for processing claims.

Shipping outside of the U.S.A.:

All orders will be shipped best way, via courier for smaller packages or via Freight forwarders for larger crates. A low handling fee may be applicable. Title to merchandise transfers to the purchaser upon delivery to the carrier. Loss or damage in transit is the responsibility of the purchaser. Qualitest USA will provide assistance with information needed for processing claims. Export fees, duties, taxes, and customs clearance are the responsibility of the purchaser.

Shipping insurance is not included, please contact our sales representatives if you need shipping insurance.

Partial shipment: Qualitest USA reserves the right to make partial shipments unless otherwise instructed by the purchaser.

Payment terms: All payments to Qualitest USA are to be made in U.S. Dollars (USD)

A. Credit Card - Qualitest USA will accept Visa, Master Card, AMEX or Discover. Required information from the purchaser is the credit card number, 3 digit security code, expiration date, card holder's name (exactly as it appears on the card), billing address, and valid telephone number for us to use in case of difficulty. Qualitest USA reserves the right to delay shipment pending verification of credit card validity.
B. Wire Transfer - Transfer must be made to Qualitest and confirmed for the full purchase amount (merchandise, handling and shipping) prior to shipment. Please contact us by phone at 1.877.884.TEST (8378)(outside U.S. +1.905.944.9825) or by fax at +1.954.697.8211 for bank information.
C. Open Account - Available to U.S.A. and Canadian customers only. Terms on open accounts are Net 30 days from date of shipment. Qualitest USA reserves the right to refuse shipment of new orders if any unpaid invoices are older than 30 days. Purchasers may apply for an open account by providing:

their bank information
3 credit references from other suppliers
Please allow 5 business days for confirmation of credit and creation of an open account.

Return Policy:

Qualitest USA may accept return of purchased merchandise within North America for refund or credit under the following conditions -

  • There may be an additional restocking fee charged to the transaction if items are already shipped to customer.
  • Goods must be returned to Qualitest USA within 5 days of the date of the receipt of the purchased goods.
  • All freight, duties, customs, and other related shipping charges for the returned merchandise are borne by the purchaser. Shipments made freight collect will be refused.
  • Merchandise must be returned properly packaged in brand new, salable condition, along with original packaging and all documentation, accessories and certificates.
  • Purchaser has confirmed return authorization directly with Qualitest.
  • Merchandise is regular catalog item. Special order items can not be returned.
  • All returned merchandise is subject to inspection by Qualitest. Qualitest reserves the right to refuse return of any merchandise that is used, damaged, or not part of the current published price list. In the case Qualitest does not accept the returned merchandise, reasonable attempts will be made to notify the Buyer and the merchandise will be returned to Buyer as they were received by Qualitest. Damaged merchandise that can be restored to original condition and thus accepted for return will be evaluated on an individual basis. The purchaser will be advised of additional expenses for the repair and restoration of the returned item. After approval, these expenses will be charged to the purchaser in addition to the restocking fee.


Change of Terms:

The acceptance of any order by Qualitest USA is subject to purchaser's assent to all of the terms and conditions set forth herein. Purchaser's assent to these terms and conditions shall be presumed from the purchaser's placement of an order through the Qualitest. Any and all other terms and conditions are expressly rejected, and no addition or modification of terms and conditions shall be binding without the prior agreement of Qualitest USA in writing.

Complete Agreement:

The terms and conditions in the Qualitest web site, incorporated herein by reference, including forms, acknowledgements, quotations, invoices and sales terms and conditions constitute the entire and exclusive agreement between the purchaser and Qualitest USA LC.

Information:

Qualitest USA makes every effort to insure the accuracy of the product information displayed on its web sites, but makes no warranties, expressed or implied, as to the accuracy of the data portrayed on the web sites. Qualitest USA reserves the right to change product information, including pricing information at any time without notice. 

Trademarks and Copyrights:

The WorldofTest.com Qualitest contains trademarked product names. Product names are not to be reproduced or used in any fashion by any party other than Qualitest without the express written consent of Qualitest International Inc.. All pictures, descriptions, and other content of this web site are copyrighted by Qualitest USA and may not be used without the express written permission of Qualitest USA. Purchaser acknowledges that they have no right, title, or interest in the trademarks or copyrights in the products, and purchaser covenants that it will take no action to register or otherwise interfere with such rights. Please contact us with any requests for permission or questions about our trademarks. 

Warranty Disclaimer:

No warranty or affirmation of fact, express or implied, other than expressly set forth herein is made or authorized by Qualitest USA. Qualitest USA disclaims any and all liability for product defect claims. Qualitest USA does not express or imply a warranty that any product on the web site(s) is fit for a particular purpose. Qualitest USA honors the product warranty as published and made available by Qualitest USA. Warranty claims for products not manufactured by Qualitest are the responsibility of the manufacturer. Qualitest USA will always make its best good faith effort to resolve warranty claims. 


Force Majeure:

Qualitest USA shall not be liable for any delay in or impairment of performance resulting in whole or in part from Acts of God, service interruptions, labor disruptions, insurrections, governmental decrees or controls, war risks, severe weather, supplies or raw materials, inability to procure or ship products, inability to obtain permits and/or licenses, or any other circumstances or causes beyond the control of Qualitest USA in the conduct of its business. 

Qualitest USA Privacy Policy 

I. What legal provisions govern our data processing practices? How and from where (internal/external sources) is personal data acquired? What are the rights of the user (web site visitor/registered customer)? 

1. General
As a general principle, no personal details need to be provided when visiting our Internet site. Data made available to us by you is treated in strict confidence and in accordance with the provisions of the Federal Data Protection Act. With a few exceptions (see point 2 below), our web server only registers non-personal (anonymous) data concerning the use of our site. Specifically, the log files of our web server, as a general rule, only contain the user's IP address, the last page visited by the user, the browser used, date, time and the file requested. This anonymous data, however, does not permit conclusions to be drawn about the individual users, and merely serves to prepare statistics on the use of our Internet site for the purpose of its improvement. At the same time, great importance is placed on ensuring that usage data is not linked with personal data. 

2. Personal data

Person-related data (personal data) is only used if the newsletter is ordered (by email), product(s) is (are) ordered, or to supply product information. We undertake to use the personal data entrusted to us only for the purposes stated. Purchase history is retained for assistance with future customer needs. 

II. What security measures are used to protect personal data? What are the user's options for processing personal data? 

3. Technical measures

Databases are optimally protected against third party access, loss, misuse and falsification through the use of appropriate technical means. In order to determine the popularity of individual topic areas, cookies are used in those sections. These text files are stored on your hard disk and facilitate your use of our Internet site. Thanks to these cookies, there is no need for specific registration each time you visit a section requiring registration, and we can supply you with the personalized contents you request. 

It is for you to decide whether you want to work with cookies and, if so, which kind (permanently stored on the hard disk or only placed for the time of the browser activity). However, we draw your attention to the fact that access to fields requiring registration is only possible with activated cookies. 

III. What data is communicated to third parties and for what purposes? 

4. Communication of personal data

Personal data entrusted to us by you is not communicated, leased or sold to third parties. 

IV. Which department answers questions about the processing of personal data? 

5. Contact

In the light of the rapid technical developments in connection with the Internet, we make every effort to constantly improve our Internet site and technical precautions, including those connected with data protection. We will keep you suitably informed about such measures. Any changes will be published here. Further information is available at any time by contacting Qualitest USA.

Disclaimer of liability Qualitest USA shall not be liable for direct, indirect or consequential losses resulting from or in connection with access to, use of or queries to the Qualitest web site or its links with other web sites, even if Qualitest USA has previously been informed of the possibility of such losses. No guarantee is provided as to the accuracy of the information disseminated via the Qualitest USA web site. In addition, Qualitest USA guarantees neither the reliability nor the completeness of the information contained on its web site. The information made available on the Qualitest and WorldofTest.com web site may be amended at any time without prior notice. In particular, Qualitest USA shall not be liable for losses caused by transmission errors, technical faults and interruptions, breakdowns or an unlawful interference with the user's data processing system or the generally accessible systems and transmission networks. Nor shall Qualitest USA be liable for losses resulting from breakdowns, interruptions or overloads occurring to any data processing systems. If certain links are activated on the Qualitest and WorldofTest.com web site, the user may under certain circumstances leave the Qualitest web site. Qualitest USA assumes no responsibility for the contents, products or services offered or other information or offers contained on these linked web sites. 

Related Products