IPX1 IPX2 Drip Box Tester – Quali-IPX™ DBT
The Quali-IPX™ DBT is an IPX1 and IPX2 drip box testing system designed to assess how effectively electrical enclosures resist vertically falling water. It supports product manufacturers, certification facilities, and safety engineering teams conducting ingress protection evaluations. Based on the drip box configuration specified in IEC 60529, the system incorporates 2,601 nozzles arranged in a 51 × 51 grid, with 20 mm spacing between nozzle centers. This arrangement provides water coverage across a 1,000 × 1,000 mm test area. A powered turntable rotates the specimen and automatically adjusts its inclination to 15° for IPX2 testing. Operators can configure the water flow, drip height, and exposure time through the touchscreen interface.
Consistent water distribution across the entire specimen is essential when evaluating luminaires, switchgear, household appliances, and information technology equipment. The Quali-IPX™ DBT achieves controlled precipitation using detachable stainless steel nozzles supplied by a filtered, pump-controlled water circuit. Before water reaches the nozzle openings, the filtration system removes suspended particles that could obstruct the narrow passages and affect the specified drip rate. An electrically operated lifting mechanism also allows the drip tank to be positioned at heights ranging from 500 mm to 2,200 mm above the turntable base.
A programmable logic controller (PLC) coordinates the water supply, tank positioning, and specimen rotation to carry out complete IPX1 and IPX2 test sequences automatically. Its touchscreen provides an English-language operating interface, while custom tank dimensions can be specified to accommodate larger test specimens. Technicians can monitor test settings throughout each cycle and record the relevant conditions for compliance documentation. Qualitest supplies the Quali-IPX™ DBT to North American testing and certification laboratories conducting product evaluations under the IP protection classification system.
IPX1 IPX2 Drip Box Tester – Quali-IPX™ DBT Applications
Products designed for environments where exposure to vertically falling water is a consideration may require IPX1 or IPX2 verification. The Quali-IPX™ DBT supports manufacturers and testing facilities across several industries, including lighting, electrical equipment, consumer appliances, and medical technology. It evaluates enclosure protection corresponding to the first two water-protection levels identified by the second characteristic numeral of the IP code.
-
Luminaire and LED Lighting Manufacturing: Assesses indoor lighting fixtures and installations in semi-sheltered environments for compliance with the water ingress provisions of IEC 60598-1 before manufacturers assign an IP protection rating.
-
Household Appliance Safety Testing: Evaluates whether kettles, food processors, and washing machines can withstand condensation and water dripping from above, as required under EN 60335-1.
-
Low-Voltage Switchgear and Controlgear: Tests distribution boards, contactors, and electrical control cabinets against IEC 60947-1 requirements, particularly for installations where overhead plumbing or ceiling leaks may expose enclosures to dripping water.
-
Information Technology and Telecom Equipment: Examines servers, network routers, and rack-mounted equipment for compliance with EN 60950 when intended for data centers and equipment rooms.
-
Rotating Electrical Machines: Conducts IP code drip assessments on motors, generators, and pump assemblies covered by IEC 60034-5 as part of pre-shipment product verification.
-
Medical Device Enclosures: Evaluates the resistance of bedside monitoring equipment, infusion pumps, and diagnostic carts to overhead water exposure in locations containing fluid supply lines.
-
Transformers and Power Supply Units: Determines whether dry-type transformers and switch-mode power supplies meet the applicable drip protection requirements of VDE 0570 Part 1.
-
Appliance Switch and Control Components: Tests cord-operated switches, panel-mounted switches, and appliance control components under VDE 0630 before they are incorporated into finished equipment.
-
Third-Party Certification Laboratories: Provides a controlled and repeatable water exposure setup for certification programs involving different product types and client requirements.
Standards
The Quali-IPX™ DBT supports water ingress protection testing for electrical and electronic products covered by the following international and industry-specific standards. Its drip box arrangement is intended for evaluating enclosure resistance to vertically falling water under IPX1 and IPX2 test conditions.
-
IEC 60034-5 - Rotating Electrical Machines, Part 5: Degrees of Protection Provided by the Integral Design of Rotating Electrical Machines (IP Code)
-
IEC 60598-1 - Luminaires, Part 1: General Requirements and Tests
- IEC 60529 - Degrees of Protection Provided by Enclosures (IP Code)
- IEC 60947-1 - Low-Voltage Switchgear and Controlgear, Part 1: General Rules
- EN 60950 - Safety of Information Technology Equipment
- EN 60335-1 - Household and Similar Electrical Appliances, Safety, Part 1: General Requirements
-
VDE 0570 Part 1 (DIN EN 61558-1) - Safety of Transformers, Reactors, Power Supply Units and Similar Products, Part 1: General Requirements and Tests
-
VDE 0630 (DIN EN 61058-1) - Switches for Appliances, Part 1: General Requirements
IPX1 IPX2 Drip Box Tester – Quali-IPX™ DBT Key Features
Designed for laboratories performing frequent ingress protection assessments, the Quali-IPX™ DBT combines automated specimen handling with controlled water delivery and accessible maintenance features. Its configuration helps technicians manage different test requirements through a single system while maintaining consistent operating conditions between test cycles.
-
English Touchscreen Interface: Provides direct access to essential operating settings, including water flow, drip tank elevation, specimen tilt, and test duration. Operators can configure and monitor the entire procedure through one control interface without relying on translated instructions or a separate control panel.
-
Combined IPX1 and IPX2 Testing: Supports both vertical dripping and angled water exposure on the same apparatus. The system accommodates upright specimen positioning for IPX1 and the complete four-position, 15° inclination sequence required for IPX2.
-
Detachable Stainless Steel Nozzles: Allows individual nozzle units to be removed for servicing, cleaning, or replacement. This arrangement makes it possible to address localized blockages without removing the entire drip plate from operation.
-
Controlled Water Delivery: Integrates pump operation with the electronic controller to maintain a consistent precipitation rate throughout a 10-minute test cycle, supporting comparable results across different operators and testing dates.
-
Integrated Water Filtration: Removes particulate matter from the supply water before it enters the nozzle network, helping prevent blocked openings and reducing the frequency of nozzle cleaning.
-
Powered Tank Height Adjustment: Uses an electronic lifting arrangement to position the drip tank anywhere between 500 mm and 2,200 mm above the turntable base. This provides flexibility when preparing specimens of different heights without relying on manual spacing adjustments.
-
PLC-Controlled Specimen Rotation: Coordinates turntable movement with the programmed test sequence, keeping specimen rotation and exposure time synchronized through the same stored test settings.
-
Automatic 15° Inclination Sequence: Moves the specimen through all four required IPX2 orientations according to the programmed schedule, eliminating manual repositioning and helping maintain the specified test angles.
-
Enclosed Water Supply Assembly: Keeps the tank and water delivery circuit sealed during operation, helping contain splashing and prevent airborne contaminants from entering the test water.
-
Made-to-Order Drip Tank Dimensions: Offers the option of non-standard tank measurements when the specimen requires a larger coverage area than the standard square configuration.
Theory and Method
The likelihood of water entering an electrical enclosure is influenced by how the water approaches its surface and how that exposure aligns with openings in the enclosure. With IPX1 testing, water falls vertically and carries very little horizontal momentum. Consequently, a flat upper surface with a relatively small overhang can often shield openings underneath it. Changing the enclosure's orientation by 15° alters the exposure conditions. Ventilation slots, panel joints, and cable entry points that were previously protected may become directly exposed to falling drops. IEC 60529 identifies these two exposure conditions separately as IPX1 and IPX2 under the second characteristic numeral of the IP code.
The drip box establishes the controlled water exposure required for these assessments. Its enclosed tank maintains a shallow water reservoir above a perforated base containing the nozzle arrangement. Water accumulates at the nozzle tips, where surface tension holds each drop until gravity causes it to detach and fall onto the specimen. The pump regulates the water supply pressure and the hydraulic head above the nozzle plate, influencing the rate at which drops form. During setup, technicians adjust the supply conditions until the collected water reaches the specified precipitation rate of 1.0 mm per minute across the test area. This rate applies to both IPX1 and IPX2 procedures.
Achieving consistent coverage across the specimen is essential for obtaining reliable test results. The 2,601-nozzle configuration, arranged at 20 mm intervals, distributes falling drops across the coverage area and creates overlapping water exposure. This reduces the likelihood of untreated regions or localized areas receiving concentrated streams instead of the intended drip pattern. Controlled turntable rotation further distributes the exposure by gradually changing the specimen's position beneath the nozzle array.
The two test procedures differ in specimen orientation and exposure duration. For IPX1, the specimen remains upright and undergoes continuous vertical dripping for 10 minutes. For IPX2, the specimen is exposed at four different positions, each inclined by 15°, with an exposure period of 2.5 minutes per position.
IPX1 IPX2 Drip Box Tester - Quali-IPX™ DBT Technical Specifications
| Parameter |
Quali-IPX™ DBT |
| Drip Tank Size |
1,120 × 1,120 mm (custom dimensions available) |
| Drip Coverage Area |
1,000 × 1,000 mm |
| Drip Nozzle Spacing |
20 × 20 mm |
| Drip Nozzle Quantity |
2,601 (51 × 51 grid) |
| Drip Nozzle Diameter |
Ø0.30 mm inner diameter |
| Nozzle Material |
Stainless steel, individually removable |
| Drip Tank Lift Range |
500 to 2,200 mm above turntable base |
| Turntable |
Motorized, controller-linked, tilts to 15° |
| Water System |
Fully enclosed circuit with inline filter |
| Control System |
PLC with integrated touchscreen operator interface |
| Reference Standard |
IEC 60529, Clauses 14.2.1 and 14.2.2 (IPX1 / IPX2) |
| Operating Language |
English (other languages available on request) |
| Voltage |
220 V, single phase, 48 to 60 Hz, 800 VA (custom supply available) |