Carbon & Sulfur Analyzer

Carbon & Sulfur Analyzer (New)

Passer aux informations sur le produit
Carbon & Sulfur Analyzer
SKU:

Carbon & Sulfur Analyzer (New)

The QualiCSA™ 5 is a high-performance carbon and sulfur analyzer designed for rapid elemental quality control. Engineered for metallurgical, mining, and advanced material testing, it delivers ultra-precise measurement down to 0.01 ppm within 60 seconds without compromising on accuracy or global compliance.

  • 0.01 Ppm Ultra-Trace Sensitivity
  • Fast 60 Second Analysis Cycles
  • Up To 4 Infrared Channels
  • Powerful 13.56 MHz Induction Furnace

Obtenez des tarifs personnalisés pour vos besoins spécifiques

Carbon & Sulfur Analyzer (New) – QualiCSA™ 5

Carbon and sulfur analysis is an essential quality control step when material chemistry affects metal quality, weldability, and specification compliance. The QualiCSA™ 5 Carbon & Sulfur Analyzer is a high-frequency combustion system with infrared (IR) detection, designed to deliver fast, repeatable total carbon and sulfur results for solid inorganic samples. The brochure series includes two configurations: the general-purpose QualiCSA™ 5 and the geology and mineral-focused QualiCSA™ 5M.

The QualiCSA™ 5 combusts samples in an oxygen atmosphere using a high-frequency induction furnace. The resulting CO₂ and SO₂ gases are measured through multi-channel infrared detection cells. Integrated dust and moisture control, catalytic conversion, and stabilized gas-flow management help maintain consistent analytical performance across a wide range of sample matrices.

Designed for efficient laboratory workflows, the analyzer supports rapid testing cycles for production and quality control decisions. Its software provides tools for calibration, analytical method setup, result management, and data security, helping laboratories maintain reliable testing procedures and organized data records.

Optional configurations include a halogen trap, wet-sample handling system, and high-capacity autosampler, allowing laboratories to configure the QualiCSA™ 5 according to sample types, testing requirements, and laboratory throughput.

Carbon & Sulfur Analyzer (New) – QualiCSA™ 5 Applications

Steel, Cast Iron, and Alloy Quality Control

Carbon and sulfur analysis plays an important role in steel, cast iron, and alloy quality control, supporting grade verification, melt control, and final product release testing. Reliable low-level carbon and sulfur measurement is valuable for cleaner steel production, while broader analytical ranges support foundry and alloy manufacturing. Fast analysis helps laboratories make timely production decisions, minimize rework, and maintain consistent process control.

Non-Ferrous Metals and Superalloys

Non-ferrous metals and superalloys can require precise carbon and sulfur control due to their effects on material properties and downstream processing. High-frequency combustion with infrared (IR) detection provides rapid C/S analysis for production monitoring and incoming material inspection. Consistent gas handling helps maintain repeatable measurements during extended laboratory testing and high-volume workflows.

Cemented Carbides and Advanced Materials

Carbon concentration can influence phase balance and performance in cemented carbides and advanced engineered materials. Controlled combustion and consistent gas conditioning help produce comparable carbon and sulfur results across multiple batches. This makes the analyzer suitable for both materials research and development laboratories and production quality control environments using consistent analytical procedures.

Ores, Soil, Sand, Glass, and Mineral Samples

The mineral-focused QualiCSA™ 5M configuration is designed for challenging sample matrices, including powdery, moist, and potentially corrosive materials. Moisture control and corrosion protection help support stable long-term operation when analyzing complex mineral samples. Applications include iron ore, copper ore, bauxite, rare-metal ores, coal, fluorite, sandstone, soil, sand, and glass, as referenced in the brochure materials.

Standards

The QualiCSA™ 5 Carbon & Sulfur Analyzer supports laboratory workflows aligned with recognized international and industry testing standards for carbon and sulfur analysis:

  • ISO 15350: Specifies the determination of total carbon and sulfur in steel and related materials through combustion in an induction furnace followed by infrared absorption measurement.

  • ASTM E1019: Covers analytical methods for determining carbon and sulfur in steel, iron, nickel, cobalt, and related alloys using instrumental techniques.

  • ISO/IEC 17025: Provides a framework for laboratory competence, including validated testing methods, measurement traceability, quality control, and reliable analytical results.

Carbon & Sulfur Analyzer (New) – QualiCSA™ 5 Key Features

Infrared Detection System

Carbon & Sulfur Analyzer

  • Dual-Analog High-Order Signal Processing: The QualiCSA™ 5 uses a dual-analog, high-order infrared signal path with filter-based processing. Elliptic analog filtering helps reduce sampling errors associated with purely digital filtering approaches.

  • Three Standard IR Channels: The analyzer includes three independent infrared channels as standard, consisting of two carbon channels and one low-sulfur channel. An optional high-sulfur channel expands the system to four IR channels for broader sulfur measurement capability.

  • Pyroelectric Solid-State Detectors: Infrared detectors feature pyroelectric solid-state sensing elements with a structured optical configuration and analog processing circuitry, supporting stable signal detection during carbon and sulfur analysis.

  • Synchronous Optical Chopper: A synchronous chopper motor with controlled operation maintains consistent optical modulation for continuous infrared measurement and reliable analytical performance.

  • Stable IR Light Sources: The infrared light sources are selected to provide consistent optical output and resistance to oxidation, supporting dependable operation during extended laboratory use.

  • Temperature-Controlled Gas Chamber: The gas chamber uses temperature control to maintain stable analytical gas conditions throughout the measurement process, helping improve measurement consistency.

  • Protective Positive-Pressure Environment: The infrared source and detector area operates under slight positive pressure with purified protective gas. This configuration helps minimize the influence of ambient atmospheric conditions on infrared measurements.

High-Efficiency Extraction System

Carbon & Sulfur Analyzer

  • Three-Function Extraction System: The analyzer features an integrated extraction design combining furnace chamber pre-purge, direct ash discharge, and dual-brush automatic cleaning to support efficient sample processing and routine maintenance.

  • Flexible Analytical Methods: Programmable analytical routines allow testing parameters to be configured for different sample types, helping laboratories establish suitable measurement methods for varied carbon and sulfur applications.

  • Optimized Dust Removal: The gas-path design is configured with reduced dead volume to help limit dust accumulation and minimize adsorption and desorption effects that could influence analytical results.

  • Automatic Leak Detection: An integrated leak-check function monitors carrier-gas pressure to identify potential gas-path leaks. This helps improve measurement reliability while making routine maintenance and troubleshooting more straightforward.

  • Corrosion-Resistant Gas Path: Protective materials and design features help reduce corrosion risks caused by aggressive combustion byproducts, supporting long-term gas-path durability.

  • Integrated Hardware Safety: Safety features include an anti-pinch furnace head design, controlled air-pressure operation, and automatic shutdown during power loss, helping protect laboratory personnel and equipment during routine operation and unexpected interruptions.

High-Frequency Combustion Furnace System

Carbon & Sulfur Analyzer

  • Efficient Dual-Chamber Furnace Design: The QualiCSA™ 5 features an efficient heat source with a dual-chamber, shielded furnace structure. Air-cooled observation windows and protected furnace tubing help support stable operation during continuous carbon and sulfur analysis.

  • 13.56 MHz High-Frequency Power: Operating at 13.56 MHz with adjustable power up to 2.7 kVA, the induction furnace provides the high-temperature combustion conditions required for complete combustion of diverse inorganic solid samples.

  • Stable High-Frequency Power Supply: An integrated power-supply isolation design combined with a feed-through capacitor configuration helps reduce electrical crosstalk and maintain stable high-frequency output during analysis.

  • Waveguide Radiation Shielding: Built-in waveguide shielding helps control high-frequency electromagnetic emissions around the furnace system, supporting safer laboratory operation in accordance with the radiation limits referenced in the brochure.

Flow Control System

Carbon & Sulfur Analyzer

  • Micro-Pressure Differential Control: The QualiCSA™ 5 uses micro-pressure differential control combined with high-precision electronic flow regulation to maintain stable analytical gas flow during carbon and sulfur measurement.

  • Fast PID Flow Stabilization: A PID-based control system enables rapid stabilization of gas flow, helping laboratories begin analytical testing quickly after instrument startup.

  • Automatic Gas-Saving Standby Mode: An automatic standby function reduces gas consumption when the analyzer is idle, helping improve operational efficiency during periods without active testing.

  • Optimized Gas-Path Routing: Valve-based gas routing is designed to simplify the analytical gas path, reduce dead volume, and support stable gas movement throughout measurement cycles for consistent carbon and sulfur analysis.

User-Friendly Software

Carbon & Sulfur Analyzer

  • Digital-Twin Style User Interface: The software interface provides a visual overview of instrument status, analytical trends, and operational guidance, helping users monitor testing and maintenance activities from a centralized dashboard.

  • Integrated Guidance and Reference Content: Built-in guidance and reference information provides on-demand support for routine instrument operation, analytical procedures, and servicing tasks.

  • Flexible Method Configuration: The software supports multiple analytical routines with streamlined method configuration, making it suitable for routine production quality control and laboratory carbon and sulfur analysis.

  • Two Analytical Operating Modes: The QualiCSA™ 5 provides two operating modes for different testing requirements:

    • Fast Analysis Mode: Combines furnace pre-purge with direct ash discharge to reduce reset and cycle time for faster testing workflows.

    • Standard Analysis Mode: Combines direct ash discharge with dual-brush automatic cleaning to help reduce residual dust between consecutive analyses.

  • Automatic Measurement Range Switching: The analyzer automatically switches between high- and low-range measurement channels, providing expanded analytical range coverage for different carbon and sulfur concentrations.

  • Multiple Calibration Functions: Calibration workflows include single-point, basic, multi-point, and blank calibration, giving laboratories flexibility when establishing and maintaining analytical methods.

  • USB-Key Access Control: USB-key security provides controlled instrument access. Analytical operation is disabled when the designated USB key is removed.

  • Multi-Parameter Compensation: Integrated compensation algorithms help reduce environmental effects on analytical results, including:

    • CO Compensation: Corrects the influence of carbon monoxide on carbon measurement results.

    • Atmospheric Pressure Compensation: Helps reduce measurement variation associated with changes in atmospheric pressure.

Theory and Method

The QualiCSA™ 5 Carbon & Sulfur Analyzer determines carbon and sulfur concentrations through high-frequency induction combustion in an oxygen atmosphere, followed by infrared (IR) detection. During combustion, carbon-containing components are converted into carbon monoxide (CO) and carbon dioxide (CO₂), while sulfur is converted into sulfur dioxide (SO₂).

The combustion gases then pass through integrated dust removal and moisture control stages to condition the gas stream before infrared measurement. Carbon monoxide is subsequently converted into carbon dioxide to support complete carbon measurement. Multi-channel infrared cells measure the absorption signals associated with CO₂ and SO₂, while the analytical software processes these signals against calibrated curves to determine total carbon and sulfur concentrations.

Gas Flow Path and IR Detection

The diagram illustrates the internal gas flow path of the QualiCSA™ 5 Carbon & Sulfur Analyzer during high-frequency combustion and infrared detection. It shows the sequence of oxygen control, sample combustion, combustion-gas purification and drying, and infrared signal measurement.

After combustion, the conditioned gas travels through the analytical gas path to the dedicated CO₂ and SO₂ infrared detection cells. The measured infrared signals are processed by the analyzer software to calculate carbon and sulfur concentrations before the gas is directed to the exhaust system.

Working Principle

Carbon & Sulfur Analyzer

QualiCSA™ 5 Gas Flow Path and IR Detection Process

1. Oxygen Supply and Pressure Control

The QualiCSA™ 5 begins the analytical process with controlled oxygen delivery to maintain stable combustion and gas-flow conditions.

  • Total Oxygen Pressure Reducing Valve: Regulates the incoming oxygen pressure to maintain consistent gas flow throughout the analytical process.

  • Carrier Gas Purification: Removes contaminants from the oxygen supply that could interfere with low-ppm carbon and sulfur measurements.

  • Total Oxygen Valve: Provides the primary on/off control for oxygen entering the analyzer.

2. Oxygen Routing to the Furnace

Two controlled oxygen paths direct gas to the combustion zone to support efficient sample combustion and consistent gas transport.

  • Oxygen Lance Valve: Controls the oxygen supply used for combustion support and analytical gas transport.

  • Furnace Lance Valve: Directs oxygen into the furnace chamber to support complete combustion of the sample.

  • Backblow Valve: Provides a brief reverse-flow oxygen function when required, helping clear the gas lines and reduce dust carryover into the analytical gas path.

3. Dust Capture and Moisture Removal

Following combustion, the hot gas passes through dedicated conditioning components before reaching the infrared detection system.

  • Dust Filter: Captures combustion ash and particulate matter to help protect the downstream gas path and optical components.

  • Drying Tube: Removes water vapor from the combustion gas, helping prevent infrared signal drift or saturation during measurement.

Together, these stages help condition the gas stream and support consistent results from one sample to the next.

4. Post-Furnace Switching and Purge Functions

Controlled gas routing after the furnace manages the transition from combustion to measurement and supports rapid system reset between analyses.

  • Post-Furnace Valve: Controls gas routing into the measurement stage.

  • Flushing Valve (Emptying): Purges and resets the analytical gas path between tests, helping prepare the system for the next sample.

  • Carrier Gas Purification: An additional purification stage can further condition the gas stream before infrared measurement.

5. Flow Control and Infrared Detection

The Flow Control system maintains consistent gas movement through the measurement chamber. Stable gas flow is important for repeatable infrared absorption measurements because changes in gas volume and flow conditions can affect the measured signal.

The measurement chamber contains multiple infrared detection channels:

  • LC / HC: Low- and high-range carbon channels

  • LS / HS: Low- and high-range sulfur channels

This multi-channel configuration provides a broad analytical range. Low-range channels can be used for trace concentrations, while high-range channels support samples with higher carbon or sulfur concentrations.

6. Purification, Catalytic Conversion, and Exhaust

Before the processed gas exits the analyzer, additional treatment stages help prepare the gas for discharge.

  • Purification Tube: Further conditions the gas stream and helps protect downstream components.

  • Catalytic Furnace: Converts gases as required for accurate carbon measurement and supports cleaner gas handling before exhaust.

  • Discharging Valve: Controls the final release of processed gas from the instrument.

Why the Gas Flow Process Matters

Each stage of the QualiCSA™ 5 gas path contributes to stable and repeatable carbon and sulfur analysis:

  • Clean, dry analytical gas: Purification, dust filtration, and moisture removal help support stable low-ppm measurements.

  • Consistent gas flow: Controlled flow conditions help produce repeatable infrared absorption signals.

  • Wide analytical range: Dedicated low- and high-range carbon and sulfur channels provide expanded concentration coverage without hardware reconfiguration.

  • Efficient cycle reset: Controlled flushing and gas routing help clear the analytical path and prepare the analyzer for subsequent measurements.

Carbon & Sulfur Analyzer (New) – QualiCSA™ 5 Technical Specification

Performance and Measurement

Specification QualiCSA™ 5 QualiCSA™ 5M
Method High-frequency combustion + IR detection
Carbon range (1000 mg sample) 0.6 ppm to 6.0% (0.0006–60 mg absolute mass)
Sulfur range (1000 mg sample) 0.6 ppm to 6.0% (0.0006–60 mg absolute mass)
Range expansion By changing sample weight, range can extend up to 100%
Accuracy C: 0.3 ppm or RSD ≤ 0.5% / S: 0.3 ppm or RSD ≤ 0.5%
Sensitivity 0.01 ppm
Fastest analysis cycle 60 seconds
Recommended sample mass 0.1 g to 0.5 g (adjust by content)

Furnace, Gas, and Electrical

Specification QualiCSA™ 5 QualiCSA™ 5M
Combustion furnace 13.56 MHz, 2.7 kVA, adjustable power
Carrier gas Oxygen purity ≥ 99.5%
Power gas Nitrogen or other safety gases
Voltage 220 VAC ±10%, 50 ±1 Hz, 16 A (110V is also available)

Physical

Specification QualiCSA™ 5 QualiCSA™ 5M
Dimensions (W × D × H) 620 × 760 × 800 mm
Weight 120 kg

Capability Differences

Capability area QualiCSA™ 5 QualiCSA™ 5M
Intended sample focus General-purpose inorganic solids, metals, alloys Geological/mineral samples and complex matrices
Moisture handling emphasis Supports direct wet sample introduction via physical dehydration option Stronger focus on moisture elimination for wet/powdery mineral-style samples
Dust and contamination burden High-efficiency dust removal and self-cleaning design Enhanced dust removal emphasis for heavy dust loads typical in mineral matrices
Corrosive byproducts tolerance Corrosion-resistant gas path design Corrosion protection emphasis for harsher matrices and longer continuous runs
Typical use environment Metallurgical QC + mixed lab applications Mining, geology, mineral labs, and high-load production testing environments

Le délai de livraison varie selon la disponibilité des stocks. En général, l'expédition se fait sous une semaine, mais pour certains articles très demandés, ce délai peut être de deux à trois semaines. Si vous avez besoin de ces articles en urgence, veuillez nous contacter afin de vérifier leur disponibilité et d'organiser une livraison plus rapide.

🚚

Informations importantes concernant la livraison

Le délai de livraison varie en fonction des stocks disponibles. Nos délais d'expédition standard sont généralement d'une semaine , mais pour certains articles très demandés, la livraison peut être prolongée jusqu'à deux ou trois semaines .

Besoin urgent ? Contactez-nous ici pour vérifier la disponibilité et organiser une livraison plus rapide.

Ordres:
L'acheteur reconnaît que lorsqu'il passe une commande sur Qualitest :

A. La passation de la commande signifie l'accord de l'acheteur pour passer ladite commande auprès de Qualitest et que la commande sera acceptée par le traitement réussi de la commande par Qualitest USA LC.
B. Le fait pour l'acheteur de saisir son nom à la demande de Qualitest vaut signature du contrat.
C. l'acheteur a pleine autorité pour conclure le contrat au nom de cette entité, et cette délégation de pouvoir a été indiquée par l'acheteur en passant la commande via Qualitest.
D. Des frais de traitement minimum seront appliqués au total des frais d'expédition pour toutes les commandes.

Livraison aux États-Unis :

Toutes les commandes seront expédiées en port payé, par coursier pour les petits colis ou par transporteur pour les caisses plus volumineuses. Des frais de manutention peuvent s'appliquer. La propriété des marchandises est transférée à l'acheteur dès leur remise au transporteur. L'acheteur est responsable des pertes ou dommages survenus pendant le transport. Qualitest USA fournira l'assistance nécessaire pour le traitement des réclamations.

Expédition hors des États-Unis :

Toutes les commandes seront expédiées par le moyen le plus approprié : par coursier pour les petits colis ou par transporteur pour les caisses plus volumineuses. Des frais de manutention minimes peuvent s'appliquer. La propriété des marchandises est transférée à l'acheteur dès leur remise au transporteur. L'acheteur est responsable des pertes ou dommages survenus pendant le transport. Qualitest USA fournira l'assistance nécessaire pour le traitement des réclamations. Les frais d'exportation, droits de douane, taxes et frais de dédouanement sont à la charge de l'acheteur.

L'assurance transport n'est pas incluse. Veuillez contacter nos représentants commerciaux si vous souhaitez souscrire une assurance transport.

Expédition partielle : Qualitest USA se réserve le droit d’effectuer des expéditions partielles, sauf instruction contraire de l’acheteur.

Conditions de paiement : Tous les paiements à Qualitest USA doivent être effectués en dollars américains (USD).

A. Carte de crédit – Qualitest USA accepte les cartes Visa, MasterCard, AMEX et Discover. Les informations requises de l'acheteur sont le numéro de carte, le code de sécurité à 3 chiffres, la date d'expiration, le nom du titulaire (tel qu'il apparaît sur la carte), l'adresse de facturation et un numéro de téléphone valide que nous pourrons contacter en cas de problème. Qualitest USA se réserve le droit de différer l'expédition jusqu'à vérification de la validité de la carte.
B. Virement bancaire – Le virement doit être effectué à Qualitest et confirmé pour le montant total de l'achat (marchandise, frais de traitement et d'expédition) avant l'expédition. Veuillez nous contacter par téléphone au 1 877 884 TEST (8378) (depuis l'extérieur des États-Unis : +1 905 944 9825) ou par fax au +1 954 697 8211 pour obtenir nos coordonnées bancaires.
C. Compte ouvert – Offre réservée aux clients des États-Unis et du Canada. Les conditions de paiement sont de 30 jours nets à compter de la date d'expédition. Qualitest USA se réserve le droit de refuser l'expédition de nouvelles commandes si des factures impayées datent de plus de 30 jours. Les acheteurs peuvent faire une demande d'ouverture de compte en fournissant les informations suivantes :

leurs informations bancaires
3 références de crédit d'autres fournisseurs
Veuillez prévoir un délai de 5 jours ouvrables pour la confirmation de votre crédit et la création d'un compte ouvert.

Politique de retour:

Qualitest USA peut accepter le retour de marchandises achetées en Amérique du Nord pour remboursement ou crédit sous les conditions suivantes :

  • Des frais de réapprovisionnement supplémentaires peuvent être facturés si les articles ont déjà été expédiés au client.
  • Les marchandises doivent être retournées à Qualitest USA dans les 5 jours suivant la date de réception des marchandises achetées.
  • Tous les frais de transport, droits de douane et autres frais d'expédition liés aux marchandises retournées sont à la charge de l'acheteur. Les envois en port dû seront refusés.
  • Les marchandises doivent être retournées correctement emballées, en parfait état de revente, accompagnées de leur emballage d'origine et de tous les documents, accessoires et certificats.
  • L'acheteur a confirmé l'autorisation de retour directement auprès de Qualitest.
  • Les articles proposés sont des articles de catalogue standard. Les articles commandés spécialement ne peuvent être retournés.
  • Toute marchandise retournée est soumise à inspection par Qualitest. Qualitest se réserve le droit de refuser le retour de toute marchandise utilisée, endommagée ou ne figurant pas au tarif en vigueur. Si Qualitest refuse la marchandise retournée, des efforts raisonnables seront déployés pour en informer l'acheteur, et la marchandise lui sera retournée dans son état d'origine. Les marchandises endommagées pouvant être remises en état et donc acceptées pour retour seront évaluées au cas par cas. L'acheteur sera informé des frais supplémentaires liés à la réparation et à la remise en état de l'article retourné. Après approbation, ces frais seront facturés à l'acheteur en sus des frais de restockage.


Changement de conditions :

Toute commande passée par Qualitest USA est soumise à l'acceptation par l'acheteur de l'intégralité des conditions générales énoncées ci-après. L'acceptation de ces conditions générales est présumée dès la passation de la commande par l'acheteur auprès de Qualitest. Toutes autres conditions générales sont expressément rejetées, et aucune modification ou ajout de conditions générales ne sera applicable sans l'accord écrit préalable de Qualitest USA.

Accord complet :

Les conditions générales du site Web de Qualitest, intégrées aux présentes par référence, y compris les formulaires, accusés de réception, devis, factures et conditions générales de vente, constituent l'intégralité et l'exclusivité de l'accord entre l'acheteur et Qualitest USA LC.

Information:

Qualitest USA met tout en œuvre pour garantir l'exactitude des informations sur les produits affichées sur ses sites web, mais n'offre aucune garantie, expresse ou implicite, quant à l'exactitude des données présentées. Qualitest USA se réserve le droit de modifier les informations sur les produits, y compris les prix, à tout moment et sans préavis.

Marques déposées et droits d'auteur :

Le site WorldofTest.com Qualitest contient des noms de produits déposés. Ces noms de produits ne peuvent être reproduits ni utilisés de quelque manière que ce soit par une tierce partie que Qualitest sans l'autorisation écrite expresse de Qualitest International Inc. L'ensemble des images, descriptions et autres contenus de ce site web sont la propriété de Qualitest USA et ne peuvent être utilisés sans son autorisation écrite expresse. L'acheteur reconnaît n'avoir aucun droit, titre ou intérêt sur les marques ou droits d'auteur relatifs aux produits et s'engage à ne prendre aucune mesure visant à les enregistrer ou à porter atteinte à ces droits. Veuillez nous contacter pour toute demande d'autorisation ou question concernant nos marques.

Clause de non-responsabilité relative à la garantie :

Aucune garantie ni affirmation de fait, expresse ou implicite, autre que celles expressément énoncées dans les présentes, n'est donnée ou autorisée par Qualitest USA. Qualitest USA décline toute responsabilité concernant les réclamations relatives aux défauts de produits. Qualitest USA ne garantit pas, de manière expresse ou implicite, que les produits présentés sur son ou ses sites web soient adaptés à un usage particulier. Qualitest USA honore la garantie produit telle que publiée et mise à disposition par ses soins. Les réclamations au titre de la garantie pour les produits non fabriqués par Qualitest relèvent de la responsabilité du fabricant. Qualitest USA s'efforcera toujours, en toute bonne foi, de résoudre les réclamations au titre de la garantie.


Force majeure :

Qualitest USA ne saurait être tenue responsable de tout retard ou de toute altération de ses performances résultant, en tout ou en partie, de cas de force majeure, d'interruptions de service, de conflits sociaux, d'insurrections, de décrets ou de contrôles gouvernementaux, de risques de guerre, de conditions météorologiques extrêmes, de problèmes d'approvisionnement ou de matières premières, d'une incapacité à se procurer ou à expédier des produits, d'une incapacité à obtenir des permis et/ou des licences, ou de toute autre circonstance ou cause indépendante de sa volonté dans le cadre de ses activités.

Politique de confidentialité de Qualitest USA 

I. Quelles dispositions légales régissent nos pratiques de traitement des données ? Comment et d’où proviennent les données personnelles (sources internes/externes) ? Quels sont les droits de l’utilisateur (visiteur du site web/client enregistré) ? 

1. Généralités
En règle générale, aucune donnée personnelle n'est requise pour consulter notre site Internet. Les données que vous nous communiquez sont traitées avec la plus grande confidentialité et conformément aux dispositions de la loi fédérale allemande sur la protection des données. À quelques exceptions près (voir point 2 ci-dessous), notre serveur web enregistre uniquement des données non personnelles (anonymes) relatives à l'utilisation de notre site. Plus précisément, les fichiers journaux de notre serveur web contiennent généralement l'adresse IP de l'utilisateur, la dernière page consultée, le navigateur utilisé, la date, l'heure et le fichier demandé. Ces données anonymes ne permettent toutefois pas d'identifier les utilisateurs individuellement et servent uniquement à établir des statistiques d'utilisation de notre site Internet afin de l'améliorer. Par ailleurs, nous accordons une grande importance à la non-association des données d'utilisation avec des données personnelles.

2. Données personnelles

Les données personnelles ne sont utilisées que si l'on s'abonne à la newsletter (par e-mail), si l'on commande un ou plusieurs produits, ou pour fournir des informations sur nos produits. Nous nous engageons à utiliser les données personnelles qui nous sont confiées uniquement aux fins indiquées. L'historique des achats est conservé afin de mieux répondre aux besoins futurs de nos clients.

II. Quelles mesures de sécurité sont utilisées pour protéger les données personnelles ? Quelles sont les options de l’utilisateur concernant le traitement de ses données personnelles ? 

3. Mesures techniques

Les bases de données sont protégées de manière optimale contre l'accès par des tiers, la perte, l'utilisation abusive et la falsification grâce à des moyens techniques appropriés. Afin d'évaluer la popularité des différentes thématiques, des cookies sont utilisés dans ces sections. Ces fichiers texte sont enregistrés sur votre disque dur et facilitent votre navigation sur notre site Internet. Grâce à ces cookies, vous n'avez pas besoin de vous inscrire systématiquement lorsque vous consultez une section nécessitant une inscription, et nous pouvons vous proposer un contenu personnalisé.

Il vous appartient de décider si vous souhaitez utiliser des cookies et, le cas échéant, de quel type (stockés de manière permanente sur votre disque dur ou uniquement pendant votre navigation). Veuillez noter toutefois que l'accès aux champs nécessitant une inscription n'est possible qu'avec les cookies activés.

III. Quelles données sont communiquées à des tiers et à quelles fins ? 

4. Communication des données personnelles

Les données personnelles que vous nous confiez ne sont ni communiquées, ni louées, ni vendues à des tiers.

IV. Quel service répond aux questions relatives au traitement des données personnelles ? 

5. Contact

Compte tenu de l'évolution rapide des technologies liées à Internet, nous mettons tout en œuvre pour améliorer constamment notre site web et nos mesures de sécurité, notamment en matière de protection des données. Nous vous tiendrons informés de ces mesures. Toute modification sera publiée ici. Pour plus d'informations, veuillez contacter Qualitest USA.

Clause de non-responsabilité : Qualitest USA décline toute responsabilité pour les pertes directes, indirectes ou consécutives résultant de l’accès au site web Qualitest, de son utilisation ou des requêtes effectuées sur celui-ci ou via ses liens vers d’autres sites web, même si Qualitest USA a été préalablement informée de la possibilité de telles pertes. Aucune garantie n’est donnée quant à l’exactitude des informations diffusées via le site web Qualitest USA. De plus, Qualitest USA ne garantit ni la fiabilité ni l’exhaustivité des informations contenues sur son site web. Les informations disponibles sur les sites web Qualitest et WorldofTest.com peuvent être modifiées à tout moment et sans préavis. En particulier, Qualitest USA ne saurait être tenue responsable des pertes causées par des erreurs de transmission, des défaillances techniques, des interruptions, des pannes ou une interférence illicite avec le système de traitement de données de l’utilisateur ou les systèmes et réseaux de transmission généralement accessibles. Qualitest USA ne saurait également être tenue responsable des pertes résultant de pannes, d’interruptions ou de surcharges affectant les systèmes de traitement de données. Si certains liens sont activés sur les sites web Qualitest et WorldofTest.com, l'utilisateur peut, dans certaines circonstances, quitter le site web Qualitest. Qualitest USA décline toute responsabilité quant au contenu, aux produits ou services proposés, ainsi qu'à toute autre information ou offre figurant sur ces sites web externes.

Produits associés