Carbon & Sulfur Analyzer

Carbon & Sulfur Analyzer (New)

تخطي إلى معلومات المنتج
Carbon & Sulfur Analyzer
SKU:

Carbon & Sulfur Analyzer (New)

The QualiCSA™ 5 is a high-performance carbon and sulfur analyzer designed for rapid elemental quality control. Engineered for metallurgical, mining, and advanced material testing, it delivers ultra-precise measurement down to 0.01 ppm within 60 seconds without compromising on accuracy or global compliance.

  • 0.01 Ppm Ultra-Trace Sensitivity
  • Fast 60 Second Analysis Cycles
  • Up To 4 Infrared Channels
  • Powerful 13.56 MHz Induction Furnace

Get personalized pricing for your specific requirements

Carbon & Sulfur Analyzer (New) – QualiCSA™ 5

Carbon and sulfur analysis is an essential quality control step when material chemistry affects metal quality, weldability, and specification compliance. The QualiCSA™ 5 Carbon & Sulfur Analyzer is a high-frequency combustion system with infrared (IR) detection, designed to deliver fast, repeatable total carbon and sulfur results for solid inorganic samples. The brochure series includes two configurations: the general-purpose QualiCSA™ 5 and the geology and mineral-focused QualiCSA™ 5M.

The QualiCSA™ 5 combusts samples in an oxygen atmosphere using a high-frequency induction furnace. The resulting CO₂ and SO₂ gases are measured through multi-channel infrared detection cells. Integrated dust and moisture control, catalytic conversion, and stabilized gas-flow management help maintain consistent analytical performance across a wide range of sample matrices.

Designed for efficient laboratory workflows, the analyzer supports rapid testing cycles for production and quality control decisions. Its software provides tools for calibration, analytical method setup, result management, and data security, helping laboratories maintain reliable testing procedures and organized data records.

Optional configurations include a halogen trap, wet-sample handling system, and high-capacity autosampler, allowing laboratories to configure the QualiCSA™ 5 according to sample types, testing requirements, and laboratory throughput.

Carbon & Sulfur Analyzer (New) – QualiCSA™ 5 Applications

Steel, Cast Iron, and Alloy Quality Control

Carbon and sulfur analysis plays an important role in steel, cast iron, and alloy quality control, supporting grade verification, melt control, and final product release testing. Reliable low-level carbon and sulfur measurement is valuable for cleaner steel production, while broader analytical ranges support foundry and alloy manufacturing. Fast analysis helps laboratories make timely production decisions, minimize rework, and maintain consistent process control.

Non-Ferrous Metals and Superalloys

Non-ferrous metals and superalloys can require precise carbon and sulfur control due to their effects on material properties and downstream processing. High-frequency combustion with infrared (IR) detection provides rapid C/S analysis for production monitoring and incoming material inspection. Consistent gas handling helps maintain repeatable measurements during extended laboratory testing and high-volume workflows.

Cemented Carbides and Advanced Materials

Carbon concentration can influence phase balance and performance in cemented carbides and advanced engineered materials. Controlled combustion and consistent gas conditioning help produce comparable carbon and sulfur results across multiple batches. This makes the analyzer suitable for both materials research and development laboratories and production quality control environments using consistent analytical procedures.

Ores, Soil, Sand, Glass, and Mineral Samples

The mineral-focused QualiCSA™ 5M configuration is designed for challenging sample matrices, including powdery, moist, and potentially corrosive materials. Moisture control and corrosion protection help support stable long-term operation when analyzing complex mineral samples. Applications include iron ore, copper ore, bauxite, rare-metal ores, coal, fluorite, sandstone, soil, sand, and glass, as referenced in the brochure materials.

Standards

The QualiCSA™ 5 Carbon & Sulfur Analyzer supports laboratory workflows aligned with recognized international and industry testing standards for carbon and sulfur analysis:

  • ISO 15350: Specifies the determination of total carbon and sulfur in steel and related materials through combustion in an induction furnace followed by infrared absorption measurement.

  • ASTM E1019: Covers analytical methods for determining carbon and sulfur in steel, iron, nickel, cobalt, and related alloys using instrumental techniques.

  • ISO/IEC 17025: Provides a framework for laboratory competence, including validated testing methods, measurement traceability, quality control, and reliable analytical results.

Carbon & Sulfur Analyzer (New) – QualiCSA™ 5 Key Features

Infrared Detection System

Carbon & Sulfur Analyzer

  • Dual-Analog High-Order Signal Processing: The QualiCSA™ 5 uses a dual-analog, high-order infrared signal path with filter-based processing. Elliptic analog filtering helps reduce sampling errors associated with purely digital filtering approaches.

  • Three Standard IR Channels: The analyzer includes three independent infrared channels as standard, consisting of two carbon channels and one low-sulfur channel. An optional high-sulfur channel expands the system to four IR channels for broader sulfur measurement capability.

  • Pyroelectric Solid-State Detectors: Infrared detectors feature pyroelectric solid-state sensing elements with a structured optical configuration and analog processing circuitry, supporting stable signal detection during carbon and sulfur analysis.

  • Synchronous Optical Chopper: A synchronous chopper motor with controlled operation maintains consistent optical modulation for continuous infrared measurement and reliable analytical performance.

  • Stable IR Light Sources: The infrared light sources are selected to provide consistent optical output and resistance to oxidation, supporting dependable operation during extended laboratory use.

  • Temperature-Controlled Gas Chamber: The gas chamber uses temperature control to maintain stable analytical gas conditions throughout the measurement process, helping improve measurement consistency.

  • Protective Positive-Pressure Environment: The infrared source and detector area operates under slight positive pressure with purified protective gas. This configuration helps minimize the influence of ambient atmospheric conditions on infrared measurements.

High-Efficiency Extraction System

Carbon & Sulfur Analyzer

  • Three-Function Extraction System: The analyzer features an integrated extraction design combining furnace chamber pre-purge, direct ash discharge, and dual-brush automatic cleaning to support efficient sample processing and routine maintenance.

  • Flexible Analytical Methods: Programmable analytical routines allow testing parameters to be configured for different sample types, helping laboratories establish suitable measurement methods for varied carbon and sulfur applications.

  • Optimized Dust Removal: The gas-path design is configured with reduced dead volume to help limit dust accumulation and minimize adsorption and desorption effects that could influence analytical results.

  • Automatic Leak Detection: An integrated leak-check function monitors carrier-gas pressure to identify potential gas-path leaks. This helps improve measurement reliability while making routine maintenance and troubleshooting more straightforward.

  • Corrosion-Resistant Gas Path: Protective materials and design features help reduce corrosion risks caused by aggressive combustion byproducts, supporting long-term gas-path durability.

  • Integrated Hardware Safety: Safety features include an anti-pinch furnace head design, controlled air-pressure operation, and automatic shutdown during power loss, helping protect laboratory personnel and equipment during routine operation and unexpected interruptions.

High-Frequency Combustion Furnace System

Carbon & Sulfur Analyzer

  • Efficient Dual-Chamber Furnace Design: The QualiCSA™ 5 features an efficient heat source with a dual-chamber, shielded furnace structure. Air-cooled observation windows and protected furnace tubing help support stable operation during continuous carbon and sulfur analysis.

  • 13.56 MHz High-Frequency Power: Operating at 13.56 MHz with adjustable power up to 2.7 kVA, the induction furnace provides the high-temperature combustion conditions required for complete combustion of diverse inorganic solid samples.

  • Stable High-Frequency Power Supply: An integrated power-supply isolation design combined with a feed-through capacitor configuration helps reduce electrical crosstalk and maintain stable high-frequency output during analysis.

  • Waveguide Radiation Shielding: Built-in waveguide shielding helps control high-frequency electromagnetic emissions around the furnace system, supporting safer laboratory operation in accordance with the radiation limits referenced in the brochure.

Flow Control System

Carbon & Sulfur Analyzer

  • Micro-Pressure Differential Control: The QualiCSA™ 5 uses micro-pressure differential control combined with high-precision electronic flow regulation to maintain stable analytical gas flow during carbon and sulfur measurement.

  • Fast PID Flow Stabilization: A PID-based control system enables rapid stabilization of gas flow, helping laboratories begin analytical testing quickly after instrument startup.

  • Automatic Gas-Saving Standby Mode: An automatic standby function reduces gas consumption when the analyzer is idle, helping improve operational efficiency during periods without active testing.

  • Optimized Gas-Path Routing: Valve-based gas routing is designed to simplify the analytical gas path, reduce dead volume, and support stable gas movement throughout measurement cycles for consistent carbon and sulfur analysis.

User-Friendly Software

Carbon & Sulfur Analyzer

  • Digital-Twin Style User Interface: The software interface provides a visual overview of instrument status, analytical trends, and operational guidance, helping users monitor testing and maintenance activities from a centralized dashboard.

  • Integrated Guidance and Reference Content: Built-in guidance and reference information provides on-demand support for routine instrument operation, analytical procedures, and servicing tasks.

  • Flexible Method Configuration: The software supports multiple analytical routines with streamlined method configuration, making it suitable for routine production quality control and laboratory carbon and sulfur analysis.

  • Two Analytical Operating Modes: The QualiCSA™ 5 provides two operating modes for different testing requirements:

    • Fast Analysis Mode: Combines furnace pre-purge with direct ash discharge to reduce reset and cycle time for faster testing workflows.

    • Standard Analysis Mode: Combines direct ash discharge with dual-brush automatic cleaning to help reduce residual dust between consecutive analyses.

  • Automatic Measurement Range Switching: The analyzer automatically switches between high- and low-range measurement channels, providing expanded analytical range coverage for different carbon and sulfur concentrations.

  • Multiple Calibration Functions: Calibration workflows include single-point, basic, multi-point, and blank calibration, giving laboratories flexibility when establishing and maintaining analytical methods.

  • USB-Key Access Control: USB-key security provides controlled instrument access. Analytical operation is disabled when the designated USB key is removed.

  • Multi-Parameter Compensation: Integrated compensation algorithms help reduce environmental effects on analytical results, including:

    • CO Compensation: Corrects the influence of carbon monoxide on carbon measurement results.

    • Atmospheric Pressure Compensation: Helps reduce measurement variation associated with changes in atmospheric pressure.

Theory and Method

The QualiCSA™ 5 Carbon & Sulfur Analyzer determines carbon and sulfur concentrations through high-frequency induction combustion in an oxygen atmosphere, followed by infrared (IR) detection. During combustion, carbon-containing components are converted into carbon monoxide (CO) and carbon dioxide (CO₂), while sulfur is converted into sulfur dioxide (SO₂).

The combustion gases then pass through integrated dust removal and moisture control stages to condition the gas stream before infrared measurement. Carbon monoxide is subsequently converted into carbon dioxide to support complete carbon measurement. Multi-channel infrared cells measure the absorption signals associated with CO₂ and SO₂, while the analytical software processes these signals against calibrated curves to determine total carbon and sulfur concentrations.

Gas Flow Path and IR Detection

The diagram illustrates the internal gas flow path of the QualiCSA™ 5 Carbon & Sulfur Analyzer during high-frequency combustion and infrared detection. It shows the sequence of oxygen control, sample combustion, combustion-gas purification and drying, and infrared signal measurement.

After combustion, the conditioned gas travels through the analytical gas path to the dedicated CO₂ and SO₂ infrared detection cells. The measured infrared signals are processed by the analyzer software to calculate carbon and sulfur concentrations before the gas is directed to the exhaust system.

Working Principle

Carbon & Sulfur Analyzer

QualiCSA™ 5 Gas Flow Path and IR Detection Process

1. Oxygen Supply and Pressure Control

The QualiCSA™ 5 begins the analytical process with controlled oxygen delivery to maintain stable combustion and gas-flow conditions.

  • Total Oxygen Pressure Reducing Valve: Regulates the incoming oxygen pressure to maintain consistent gas flow throughout the analytical process.

  • Carrier Gas Purification: Removes contaminants from the oxygen supply that could interfere with low-ppm carbon and sulfur measurements.

  • Total Oxygen Valve: Provides the primary on/off control for oxygen entering the analyzer.

2. Oxygen Routing to the Furnace

Two controlled oxygen paths direct gas to the combustion zone to support efficient sample combustion and consistent gas transport.

  • Oxygen Lance Valve: Controls the oxygen supply used for combustion support and analytical gas transport.

  • Furnace Lance Valve: Directs oxygen into the furnace chamber to support complete combustion of the sample.

  • Backblow Valve: Provides a brief reverse-flow oxygen function when required, helping clear the gas lines and reduce dust carryover into the analytical gas path.

3. Dust Capture and Moisture Removal

Following combustion, the hot gas passes through dedicated conditioning components before reaching the infrared detection system.

  • Dust Filter: Captures combustion ash and particulate matter to help protect the downstream gas path and optical components.

  • Drying Tube: Removes water vapor from the combustion gas, helping prevent infrared signal drift or saturation during measurement.

Together, these stages help condition the gas stream and support consistent results from one sample to the next.

4. Post-Furnace Switching and Purge Functions

Controlled gas routing after the furnace manages the transition from combustion to measurement and supports rapid system reset between analyses.

  • Post-Furnace Valve: Controls gas routing into the measurement stage.

  • Flushing Valve (Emptying): Purges and resets the analytical gas path between tests, helping prepare the system for the next sample.

  • Carrier Gas Purification: An additional purification stage can further condition the gas stream before infrared measurement.

5. Flow Control and Infrared Detection

The Flow Control system maintains consistent gas movement through the measurement chamber. Stable gas flow is important for repeatable infrared absorption measurements because changes in gas volume and flow conditions can affect the measured signal.

The measurement chamber contains multiple infrared detection channels:

  • LC / HC: Low- and high-range carbon channels

  • LS / HS: Low- and high-range sulfur channels

This multi-channel configuration provides a broad analytical range. Low-range channels can be used for trace concentrations, while high-range channels support samples with higher carbon or sulfur concentrations.

6. Purification, Catalytic Conversion, and Exhaust

Before the processed gas exits the analyzer, additional treatment stages help prepare the gas for discharge.

  • Purification Tube: Further conditions the gas stream and helps protect downstream components.

  • Catalytic Furnace: Converts gases as required for accurate carbon measurement and supports cleaner gas handling before exhaust.

  • Discharging Valve: Controls the final release of processed gas from the instrument.

Why the Gas Flow Process Matters

Each stage of the QualiCSA™ 5 gas path contributes to stable and repeatable carbon and sulfur analysis:

  • Clean, dry analytical gas: Purification, dust filtration, and moisture removal help support stable low-ppm measurements.

  • Consistent gas flow: Controlled flow conditions help produce repeatable infrared absorption signals.

  • Wide analytical range: Dedicated low- and high-range carbon and sulfur channels provide expanded concentration coverage without hardware reconfiguration.

  • Efficient cycle reset: Controlled flushing and gas routing help clear the analytical path and prepare the analyzer for subsequent measurements.

Carbon & Sulfur Analyzer (New) – QualiCSA™ 5 Technical Specification

Performance and Measurement

Specification QualiCSA™ 5 QualiCSA™ 5M
Method High-frequency combustion + IR detection
Carbon range (1000 mg sample) 0.6 ppm to 6.0% (0.0006–60 mg absolute mass)
Sulfur range (1000 mg sample) 0.6 ppm to 6.0% (0.0006–60 mg absolute mass)
Range expansion By changing sample weight, range can extend up to 100%
Accuracy C: 0.3 ppm or RSD ≤ 0.5% / S: 0.3 ppm or RSD ≤ 0.5%
Sensitivity 0.01 ppm
Fastest analysis cycle 60 seconds
Recommended sample mass 0.1 g to 0.5 g (adjust by content)

Furnace, Gas, and Electrical

Specification QualiCSA™ 5 QualiCSA™ 5M
Combustion furnace 13.56 MHz, 2.7 kVA, adjustable power
Carrier gas Oxygen purity ≥ 99.5%
Power gas Nitrogen or other safety gases
Voltage 220 VAC ±10%, 50 ±1 Hz, 16 A (110V is also available)

Physical

Specification QualiCSA™ 5 QualiCSA™ 5M
Dimensions (W × D × H) 620 × 760 × 800 mm
Weight 120 kg

Capability Differences

Capability area QualiCSA™ 5 QualiCSA™ 5M
Intended sample focus General-purpose inorganic solids, metals, alloys Geological/mineral samples and complex matrices
Moisture handling emphasis Supports direct wet sample introduction via physical dehydration option Stronger focus on moisture elimination for wet/powdery mineral-style samples
Dust and contamination burden High-efficiency dust removal and self-cleaning design Enhanced dust removal emphasis for heavy dust loads typical in mineral matrices
Corrosive byproducts tolerance Corrosion-resistant gas path design Corrosion protection emphasis for harsher matrices and longer continuous runs
Typical use environment Metallurgical QC + mixed lab applications Mining, geology, mineral labs, and high-load production testing environments

يختلف وقت التسليم حسب توافر المخزون. تكون أوقات الإرسال والشحن القياسية لدينا بشكل عام في غضون أسبوع واحد، ولكن بالنسبة لبعض المنتجات التي يزداد الطلب عليها قد يمتد التسليم إلى 2-3 أسابيع. إذا كنت تحتاج إلى هذه المنتجات بشكل عاجل، يُرجى الاتصال بنا للتحقق من توفر المخزون بدقة وتنظيم طرق شحن أسرع.

الطلبات:
يقر المشتري بأنه عند تقديم طلب على موقع Qualitest:

أ. إن تقديم الطلب يعني موافقة المشتري على تقديم الطلب المذكور في كواليتيست وأن الطلب سيتم قبوله من خلال المعالجة الناجحة للطلب من قبل شركة كواليتيست الولايات المتحدة الأمريكية LC.
ب. قيام المشتري بكتابة اسمه عندما يُطلب منه ذلك من قبل شركة كواليتيست يعتبر توقيعًا على العقد
ج. أن المشتري لديه السلطة الكاملة للدخول في العقد لصالح هذا الكيان، وأن هذا التفويض الممنوح من قبل المشتري قد تم الإشارة إليه من خلال تقديم الطلب من خلال كواليتيست.
D. سيتم تطبيق حد أدنى لرسوم المناولة على إجمالي الشحن لجميع الطلبات.

الشحن داخل الولايات المتحدة الأمريكية:

سيتم شحن جميع الطلبات بأفضل طريقة مدفوعة مسبقًا، عن طريق البريد السريع للطرود الصغيرة أو عن طريق وكلاء الشحن للصناديق الأكبر حجمًا. قد يتم تطبيق رسوم مناولة على الطلبات. تنتقل ملكية البضائع إلى المشتري عند التسليم إلى شركة النقل. تقع مسؤولية الفقد أو التلف أثناء النقل على عاتق المشتري. ستقدم شركة Qualitest USA المساعدة في المعلومات اللازمة لمعالجة المطالبات.

الشحن خارج الولايات المتحدة الأمريكية:

سيتم شحن جميع الطلبات بأفضل طريقة، عبر البريد السريع للطرود الصغيرة أو عبر وكلاء الشحن للصناديق الأكبر حجمًا. قد يتم تطبيق رسوم مناولة منخفضة. تنتقل ملكية البضائع إلى المشتري عند التسليم إلى شركة النقل. تقع مسؤولية الفقد أو التلف أثناء النقل على عاتق المشتري. ستقدم شركة Qualitest USA المساعدة في المعلومات اللازمة لمعالجة المطالبات. يتحمل المشتري مسؤولية رسوم التصدير والرسوم والضرائب والتخليص الجمركي.

تأمين الشحن غير مشمول، يرجى الاتصال بمندوبي المبيعات لدينا إذا كنت بحاجة إلى تأمين الشحن.

الشحن الجزئي: تحتفظ شركة Qualitest USA بالحق في إجراء شحنات جزئية ما لم يطلب المشتري خلاف ذلك.

شروط الدفع: يجب أن تتم جميع المدفوعات إلى Qualitest USA بالدولار الأمريكي (USD)

A. بطاقة الائتمان - تقبل كواليتيست الولايات المتحدة الأمريكية بطاقات الفيزا أو ماستر كارد أو أمريكان إكسبريس أو ديسكفر. المعلومات المطلوبة من المشتري هي رقم بطاقة الائتمان، ورمز الأمان المكون من 3 أرقام، وتاريخ انتهاء الصلاحية، واسم صاحب البطاقة (كما يظهر بالضبط على البطاقة)، وعنوان إرسال الفواتير، ورقم هاتف صالح لنا لاستخدامه في حالة وجود صعوبة. تحتفظ Qualitest USA بالحق في تأخير الشحن في انتظار التحقق من صلاحية بطاقة الائتمان.
B. التحويل البنكي - يجب أن يتم التحويل إلى Qualitest وتأكيد مبلغ الشراء بالكامل (البضائع والمناولة والشحن) قبل الشحن. يُرجى الاتصال بنا عبر الهاتف على الرقم 1.877.884.884.TEST (8378) (خارج الولايات المتحدة على الرقم +1.905.944.9825) أو عبر الفاكس على الرقم +1.954.697.8211 للحصول على المعلومات المصرفية.
C. الحساب المفتوح - متاح لعملاء الولايات المتحدة الأمريكية وكندا فقط. شروط الحسابات المفتوحة هي صافي 30 يومًا من تاريخ الشحن. تحتفظ Qualitest USA بالحق في رفض شحن الطلبات الجديدة إذا كانت أي فواتير غير مدفوعة أقدم من 30 يومًا. يمكن للمشترين التقدم بطلب للحصول على حساب مفتوح من خلال تقديم:

معلوماتهم المصرفية
3 مراجع ائتمانية من موردين آخرين
يُرجى الانتظار 5 أيام عمل لتأكيد الائتمان وإنشاء حساب مفتوح.

سياسة الإرجاع:

قد تقبل شركة كواليتيست الولايات المتحدة الأمريكية إرجاع البضائع المشتراة داخل أمريكا الشمالية لاسترداد قيمتها أو إرجاعها بموجب الشروط التالية -

  • قد تكون هناك رسوم إعادة تخزين إضافية تُفرض على المعاملة إذا تم شحن البضائع بالفعل إلى العميل.
  • يجب إعادة البضائع إلى Qualitest USA في غضون 5 أيام من تاريخ استلام البضائع المشتراة.
  • يتحمل المشتري جميع رسوم الشحن والرسوم والجمارك وغيرها من رسوم الشحن ذات الصلة للبضائع المرتجعة. سيتم رفض الشحنات التي يتم تحصيل رسوم الشحن.
  • يجب إرجاع البضائع معبأة بشكل صحيح في حالة جديدة وقابلة للبيع، مع التغليف الأصلي وجميع الوثائق والملحقات والشهادات.
  • أكد المشتري إذن الإرجاع مباشرةً مع Qualitest.
  • البضائع هي سلع الكتالوج العادية. لا يمكن إرجاع سلع الطلبات الخاصة.
  • تخضع جميع البضائع المرتجعة للفحص من قبل Qualitest. تحتفظ شركة Qualitest بالحق في رفض إرجاع أي بضاعة مستخدمة أو تالفة أو ليست جزءًا من قائمة الأسعار المنشورة الحالية. في حالة عدم قبول Qualitest للبضائع المرتجعة، ستبذل محاولات معقولة لإخطار المشتري وسيتم إعادة البضائع إلى المشتري كما استلمتها Qualitest. سيتم تقييم البضائع التالفة التي يمكن استعادتها إلى حالتها الأصلية وبالتالي قبول إرجاعها على أساس فردي. سيتم إبلاغ المشتري بالنفقات الإضافية لإصلاح وترميم السلعة المرتجعة. بعد الموافقة، سيتم تحميل هذه النفقات على المشتري بالإضافة إلى رسوم إعادة التخزين.


تغيير الشروط:

يخضع قبول أي طلب من قبل Qualitest USA لموافقة المشتري على جميع الشروط والأحكام المنصوص عليها هنا. ويفترض موافقة المشتري على هذه الشروط والأحكام منذ تقديم المشتري لطلب الشراء من خلال كواليتيست. يتم رفض أي وجميع الشروط والأحكام الأخرى صراحة، ولا تكون أي إضافة أو تعديل للشروط والأحكام ملزمة دون موافقة مسبقة من شركة Qualitest USA خطياً.

الاتفاقية الكاملة:

تشكل الشروط والأحكام الواردة في موقع Qualitest على شبكة الإنترنت، المدرجة هنا بالإحالة، بما في ذلك النماذج والإقرارات وعروض الأسعار والفواتير وشروط وأحكام وشروط البيع الاتفاقية الكاملة والحصرية بين المشتري وشركة Qualitest USA LC.

المعلومات:

تبذل كواليتيست الولايات المتحدة الأمريكية كل جهد ممكن لضمان دقة معلومات المنتج المعروضة على مواقعها على شبكة الإنترنت، ولكنها لا تقدم أي ضمانات، صريحة أو ضمنية، فيما يتعلق بدقة البيانات المعروضة على مواقع الويب. تحتفظ Qualitest USA بالحق في تغيير معلومات المنتج، بما في ذلك معلومات التسعير في أي وقت دون إشعار مسبق.

العلامات التجارية وحقوق التأليف والنشر:

يحتوي موقع WorldofTest.com Qualitest.com على أسماء منتجات تحمل علامات تجارية. لا يجوز إعادة إنتاج أسماء المنتجات أو استخدامها بأي شكل من الأشكال من قبل أي طرف آخر غير شركة كواليتيست دون موافقة خطية صريحة من شركة كواليتيست الدولية. جميع الصور والأوصاف والمحتويات الأخرى لهذا الموقع الإلكتروني محمية بحقوق الطبع والنشر لشركة Qualitest USA ولا يجوز استخدامها دون إذن كتابي صريح من شركة Qualitest USA. يقر المشتري بأنه ليس له أي حق أو سند ملكية أو مصلحة في العلامات التجارية أو حقوق التأليف والنشر في المنتجات، ويتعهد المشتري بأنه لن يتخذ أي إجراء لتسجيل أو التدخل في هذه الحقوق. يُرجى الاتصال بنا بشأن أي طلبات للحصول على إذن أو أسئلة حول علاماتنا التجارية.

إخلاء المسؤولية عن الضمان:

لا يتم تقديم أي ضمان أو تأكيد للحقائق، صريحًا أو ضمنيًا، بخلاف ما هو منصوص عليه صراحةً في هذه الوثيقة أو مصرح به من قبل Qualitest USA. تخلي Qualitest USA مسؤوليتها عن أي وكل مسؤولية عن مطالبات عيوب المنتج. لا تعرب Qualitest USA عن أي ضمان صريح أو ضمني بأن أي منتج على الموقع (المواقع) على شبكة الإنترنت مناسب لغرض معين. تحترم Qualitest USA ضمان المنتج كما هو منشور ومتاح من قبل Qualitest USA. مطالبات الضمان للمنتجات غير المصنعة من قبل Qualitest هي مسؤولية الشركة المصنعة. ستبذل Qualitest USA دائمًا أفضل جهودها بحسن نية لحل مطالبات الضمان.


القوة القاهرة:

لن تكون شركة Qualitest USA مسؤولة عن أي تأخير في الأداء أو إعاقة الأداء الناتج كليًا أو جزئيًا عن أعمال القدرة، أو انقطاع الخدمة، أو انقطاع الخدمة، أو تعطل العمل، أو العصيانات، أو المراسيم أو الضوابط الحكومية، أو مخاطر الحرب، أو الطقس القاسي، أو الإمدادات أو المواد الخام، أو عدم القدرة على شراء أو شحن المنتجات، أو عدم القدرة على الحصول على تصاريح و / أو تراخيص، أو أي ظروف أو أسباب أخرى خارجة عن سيطرة Qualitest USA في إدارة أعمالها.

سياسة الخصوصية الخاصة بشركة Qualitest USA 

I. ما هي الأحكام القانونية التي تحكم ممارساتنا في معالجة البيانات؟ كيف ومن أين (مصادر داخلية/خارجية) يتم الحصول على البيانات الشخصية؟ما هي حقوق المستخدم (زائر الموقع الإلكتروني/ العميل المسجل)؟ 

1. 1. عام
كمبدأ عام، لا يلزم تقديم أي بيانات شخصية عند زيارة موقعنا على الإنترنت. يتم التعامل مع البيانات التي تقدمها لنا بسرية تامة ووفقًا لأحكام القانون الاتحادي لحماية البيانات. مع بعض الاستثناءات القليلة (انظر النقطة 2 أدناه)، لا يسجل خادم الويب الخاص بنا سوى البيانات غير الشخصية (مجهولة المصدر) المتعلقة باستخدام موقعنا. على وجه التحديد، تحتوي ملفات السجل الخاصة بخادم الويب الخاص بنا، كقاعدة عامة، فقط على عنوان IP الخاص بالمستخدم، وآخر صفحة زارها المستخدم، والمتصفح المستخدم، والتاريخ والوقت والملف المطلوب. ومع ذلك، فإن هذه البيانات مجهولة المصدر لا تسمح باستخلاص استنتاجات حول المستخدمين الأفراد، وتعمل فقط على إعداد إحصائيات حول استخدام موقعنا على الإنترنت بغرض تحسينه. وفي الوقت نفسه، نولي أهمية كبيرة لضمان عدم ربط بيانات الاستخدام بالبيانات الشخصية.

2. البيانات الشخصية

لا تُستخدم البيانات المتعلقة بالأشخاص (البيانات الشخصية) إلا في حالة طلب النشرة الإخبارية (عن طريق البريد الإلكتروني)، أو طلب (طلبات) المنتج (المنتجات)، أو توفير معلومات عن المنتج. نتعهد باستخدام البيانات الشخصية الموكلة إلينا فقط للأغراض المذكورة. يتم الاحتفاظ بسجل الشراء للمساعدة في تلبية احتياجات العملاء المستقبلية.

ثانيًا. ما هي التدابير الأمنية المستخدمة لحماية البيانات الشخصية؟ما هي الخيارات المتاحة للمستخدم لمعالجة البيانات الشخصية؟ 

3-التدابير الفنية

تتم حماية قواعد البيانات على النحو الأمثل ضد وصول الغير إليها وضياعها وإساءة استخدامها وتزويرها من خلال استخدام الوسائل التقنية المناسبة. من أجل تحديد شعبية مجالات الموضوعات الفردية، يتم استخدام ملفات تعريف الارتباط في تلك الأقسام. يتم تخزين هذه الملفات النصية على القرص الصلب الخاص بك وتسهيل استخدامك لموقعنا على الإنترنت. وبفضل ملفات تعريف الارتباط هذه، ليست هناك حاجة للتسجيل المحدد في كل مرة تزور فيها أحد الأقسام التي تتطلب التسجيل، ويمكننا تزويدك بالمحتويات المخصصة التي تطلبها.

الأمر متروك لك لتقرر ما إذا كنت ترغب في العمل مع ملفات تعريف الارتباط، وإذا كان الأمر كذلك، فأي نوع (مخزنة بشكل دائم على القرص الصلب أو توضع فقط في وقت نشاط المتصفح). ومع ذلك، فإننا نلفت انتباهك إلى حقيقة أن الوصول إلى الحقول التي تتطلب التسجيل لا يمكن الوصول إليها إلا باستخدام ملفات تعريف الارتباط المفعلة.

ثالثًا. ما هي البيانات التي يتم إرسالها إلى أطراف ثالثة ولأي أغراض؟ 

4. إرسال البيانات الشخصية

لا يتم إرسال البيانات الشخصية التي عهدت بها إلينا من جانبك أو تأجيرها أو بيعها لأطراف ثالثة.

رابعا. ما القسم الذي يجيب على الأسئلة المتعلقة بمعالجة البيانات الشخصية؟ 

5. الاتصال

في ضوء التطورات التقنية السريعة فيما يتعلق بالإنترنت، نبذل قصارى جهدنا لتحسين موقعنا على الإنترنت والاحتياطات التقنية باستمرار، بما في ذلك تلك المتعلقة بحماية البيانات. سنبقيك على اطلاع دائم على هذه الإجراءات بشكل مناسب. سيتم نشر أي تغييرات هنا. يتوفر المزيد من المعلومات في أي وقت عن طريق الاتصال بشركة Qualitest USA.

إخلاء المسؤولية لن تكون شركة كواليتيست الولايات المتحدة الأمريكية مسؤولة عن الخسائر المباشرة أو غير المباشرة أو التبعية الناتجة عن أو فيما يتعلق بالوصول إلى أو استخدام أو الاستعلام عن موقع كواليتيست الولايات المتحدة الأمريكية أو روابطه مع مواقع الويب الأخرى، حتى لو تم إبلاغ كواليتيست الولايات المتحدة الأمريكية مسبقاً باحتمال حدوث مثل هذه الخسائر. لا يتم تقديم أي ضمان فيما يتعلق بدقة المعلومات المنشورة عبر موقع كواليتيست الولايات المتحدة الأمريكية على شبكة الإنترنت. وبالإضافة إلى ذلك، لا تضمن كواليتيست الولايات المتحدة الأمريكية موثوقية أو اكتمال المعلومات الواردة على موقعها على شبكة الإنترنت. قد يتم تعديل المعلومات المتاحة على موقع Qualitest و WorldofTest.com على شبكة الإنترنت في أي وقت دون إشعار مسبق. وعلى وجه الخصوص، لن تكون كواليتيست الولايات المتحدة الأمريكية مسؤولة عن الخسائر الناجمة عن أخطاء الإرسال أو الأعطال الفنية والانقطاعات أو الأعطال أو التداخل غير القانوني مع نظام معالجة البيانات الخاص بالمستخدم أو الأنظمة وشبكات الإرسال التي يمكن الوصول إليها بشكل عام. كما لا تتحمل شركة كواليتيست الولايات المتحدة الأمريكية المسؤولية عن الخسائر الناجمة عن الأعطال أو الانقطاعات أو الأحمال الزائدة التي تحدث لأي أنظمة معالجة البيانات. إذا تم تنشيط بعض الروابط على موقع Qualitest و WorldofTest.com على شبكة الإنترنت، يجوز للمستخدم في ظل ظروف معينة مغادرة موقع Qualitest. لا تتحمل شركة كواليتيست الولايات المتحدة الأمريكية أية مسؤولية عن المحتويات أو المنتجات أو الخدمات المعروضة أو غيرها من المعلومات أو العروض الواردة في هذه المواقع المرتبطة.

المنتجات ذات الصلة