Carbon & Sulfur Analyzer

Carbon & Sulfur Analyzer – QualiCSA™ 3

Ir directamente a la información del producto
Carbon & Sulfur Analyzer
SKU:

Carbon & Sulfur Analyzer – QualiCSA™ 3

The QualiCSA™ 3 is a high-performance carbon and sulfur analyzer designed for rapid elemental determination in solid materials. Engineered for metallurgy and industrial testing laboratories, it delivers ultra-precise measurements down to 0.01 ppm within 40 to 60 seconds without compromising on stability or dynamic range.

  • 0.01 Ppm Detection Sensitivity
  • Fast 40 To 60 Second Cycles
  • Up To 4 Detection Channels
  • Max 1550°C Dual Combustion

Obtenga precios personalizados para sus requisitos específicos

Carbon & Sulfur Analyzer – QualiCSA™ 3

Available Carbon & Sulfur Analyzer Models

  • High-Frequency Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3

  • Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3G

Carbon & Sulfur Analyzer – QualiCSA™ 3 Applications

High-Frequency Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3

The QualiCSA™ 3 Carbon & Sulfur Analyzer is designed for rapid carbon and sulfur analysis using high-frequency induction heating, infrared detection, advanced combustion technology, and full-range detection capabilities. The system provides simultaneous measurement of carbon and sulfur concentrations in a broad range of solid materials.

The QualiCSA™ 3 is suitable for laboratories and testing applications across steel, powder metallurgy, non-ferrous metals, magnetic materials, new energy materials, third-party testing, research institutes, and other industrial sectors. It can analyze carbon and sulfur in steel and alloys, non-ferrous metals, powder metallurgy materials, rare earth materials, NdFeB, ores, and other solid samples.

A stable, high-efficiency high-frequency power system supports complete sample combustion for reliable analysis. The analyzer also incorporates effective shielding against high-frequency interference to support consistent analytical performance and measurement stability.

Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3G

The QualiCSA™ 3G Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer combines high-frequency induction heating and tubular resistance furnace technology to accommodate a wider range of sample types and analytical requirements.

The instrument features two sample pretreatment and combustion systems: a high-frequency induction furnace and a tubular resistance furnace. Both furnace systems use the same infrared detection system to measure the carbon- and sulfur-containing gases generated during combustion. Switching between the two furnace systems is straightforward, allowing the analyzer to support different testing methods and sample characteristics.

The QualiCSA™ 3G is suitable for carbon and sulfur analysis across a diverse range of solid materials, including steel, cast iron, alloys, metal ores, ceramics, cement, lime, rubber, coal, coke, refractory materials, carbide, graphite, oil, catalysts, soil, and other materials.

With dual furnace capabilities and a shared infrared detection platform, the QualiCSA™ 3G Carbon & Sulfur Analyzer provides a flexible solution for laboratories requiring carbon and sulfur analysis across varied sample types and testing applications.

Features of the High-Frequency Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3

Modular Instrument Configuration

  • Infrared Detection Unit: Supports up to four independent infrared detection channels, with a high-sulfur channel available according to application requirements. The system uses pyroelectric solid-state infrared detectors.

  • Motor: A synchronous motor supports continuous analyzer operation with dependable performance.

  • Infrared Light Source: The infrared source provides stable optical performance and resistance to oxidation.

  • Temperature Control: The IR cell temperature is continuously maintained at a stable level to support measurement accuracy.

  • Copper Oxide Catalysis Furnace (Optional): Converts trace CO to CO₂ for complete carbon detection. It also converts SO₂ to SO₃, which is absorbed by cotton to help reduce emissions.

Instrument Self-Check and Gas Management

  • Stable Flow Control: High-precision differential-pressure electronic flow control technology provides consistent analysis gas flow.

  • Gas-Saving Mode: Oxygen flow automatically stops when an analysis cycle is complete, helping reduce oxygen consumption.

User-Friendly Analysis Software

The QualiCSA™ 3 includes English-language operating software compatible with Windows 10 and Windows 11. The software is designed for straightforward operation and supports free software updates.

Flexible Sample Weight Input

The system provides multiple options for entering or obtaining specimen weight values:

  • Automatic weight reading

  • Manual weight reading

  • Manual weight entry

  • Automatic crucible tare

Automatic Range Switching

The analyzer automatically switches between high and low carbon and sulfur measurement ranges according to the concentration detected.

Automatic Flux Blank Deduction

The software automatically deducts the flux blank value during analysis to support accurate measurement results.

Comprehensive Data and System Display

The software provides access to:

  • Release curve comparison and storage

  • Analytical result statistics

  • Quick data searches

  • Maintenance reminders

  • Monitoring of key instrument parameters

Additional Diagnostic Checks

Solenoid Valve Check:
Displays the operating status of individual solenoid valves and allows each valve to be operated independently.

Signal Acquisition Check:
Monitors the acquisition signals throughout the analyzer system.

High-Frequency Status Check:
Provides high-frequency furnace preheating countdown information.

Baseline Check:
Provides real-time monitoring of the baseline for each infrared detection channel.

Automatic Zero Check:
Software-controlled automatic baseline zeroing helps maintain stable detection conditions.


Features of the Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3G

The QualiCSA™ 3G Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer combines high-frequency induction combustion and tubular resistance furnace technology with infrared gas detection for carbon and sulfur analysis across a broad range of solid materials.

Key Features

  • Germany-produced solid-state infrared detector components

  • Flexible heating power control

  • Full manual operating mode

  • Advanced infrared thermostatic technology

  • High-precision gas flow control

  • Dedicated computer operating software

  • Advanced linear signal processing

  • High analytical precision

  • Reliable electronic circuit components

  • Comprehensive self-diagnostic functions

  • Multiple circuit protection systems

  • Fully enclosed gas channel design with zero dead volume

Infrared absorption following high-frequency combustion or tubular furnace combustion enables rapid analysis of carbon and sulfur concentrations in solid inorganic materials.

Software Functions

The QualiCSA™ 3G software provides comprehensive instrument control and data management functions, including:

  • Monitoring solenoid valve movement throughout the gas channels

  • Detection and adjustment of infrared signals

  • Rapid display of analytical results and release curves

  • Automatic storage of analytical results

  • Generation and storage of dynamic release curves

  • Automatic specimen weight reading

  • Manual specimen weight entry when required

  • Automatic switching between high-carbon, low-carbon, and sulfur detection channels

Data Processing and Analysis

The software supports multiple approaches for reviewing and processing analytical data:

  • Data retrieval by date or specimen ID

  • Data screening and filtering

  • Statistical processing, including mean, standard deviation, and relative deviation

  • Comparison of analytical signals with stored release curves

High-Precision Flow Control

The analyzer uses high-precision electronic flow control technology with an Anti-Overshoot System to provide precise control of the analysis gas flow during measurement.

Catalytic Oxidation in the Copper Furnace

Before entering the carbon detection cell, the analysis gas passes through the copper furnace for catalytic oxidation. This process converts CO into CO₂, supporting detection of the carbon-containing gases generated during combustion.

The copper furnace also converts analyzed SO₂ into SO₃, which is subsequently absorbed to help reduce air emissions.

Automatic Dust Filtration

A specialized dust filter made from powder metallurgy materials removes particulate matter from the analysis gas. The filter is automatically cleaned twice during each analysis cycle.

Automatic Self-Check and Diagnostics

The QualiCSA™ 3G provides comprehensive self-checking functions to monitor key operating conditions, including:

  • Overall oxygen pressure at the furnace inlet

  • Analysis pressure at the rear of the furnace

  • Dynamic gas pressure

  • High-frequency furnace on/off status

  • Cleaning device reset status within the high-frequency furnace

  • Infrared signal monitoring and adjustment

  • Solenoid valve movement throughout the gas channels

The software provides step-by-step diagnostic functions, allowing individual components and systems to be checked as needed.

Electronic Specimen Weighing

An electronic balance can be connected directly to the computer for accurate specimen weighing. The measured weight is automatically transferred to the analysis software. Manual specimen weight entry is also available when required.

Typical Analysis Time

  • High-frequency induction furnace: 40–60 seconds

  • Tubular resistance furnace: 150–300 seconds

Crucible and Combustion Vessel

High-Frequency Induction Furnace:

  • Ceramic crucible

  • Diameter: 25 mm

  • Height: 27 mm

Tubular Resistance Furnace:

  • Porcelain combustion boat

  • Length: 87 mm

  • Width: 12 mm

  • Height: 10 mm

Combustion Furnace Specifications

High-Frequency Induction Furnace:

  • Frequency: 18 MHz

  • Maximum power: 2.7 kVA

Tubular Resistance Furnace:

  • Maximum temperature: 1550°C

  • Maximum power: 4.4 kW

  • Carborundum heating elements

  • Controlled heating power to support extended element life

  • Furnace case reaches operating temperature in approximately 20 minutes

Crucible Pre-Treatment

The ceramic crucible used with the high-frequency induction furnace can be pre-treated in the tubular resistance furnace. This dual-purpose configuration improves workflow efficiency while supporting consistent and reliable carbon and sulfur analysis.

Theory and Method

Instrument Principle – QualiCSA™ 3G Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer

The QualiCSA™ 3G Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer uses infrared absorption analysis following high-temperature combustion. Depending on the specimen and testing requirements, users can select either the tubular resistance furnace or high-frequency induction furnace as the specimen treatment and combustion unit.

After gas purification, oxygen is introduced into the selected combustion furnace as the carrier gas. The specimen undergoes high-temperature oxidation, generating CO₂, CO, and SO₂. The combustion gases then pass through dust removal and dehydration stages before entering the sulfur detection system.

The oxygen and resulting gas mixture subsequently pass through a heated catalytic furnace. During catalytic oxidation, CO is converted to CO₂, while SO₂ is converted to SO₃. After sulfur removal, the gas mixture is directed sequentially through the high-carbon detection cell and low-carbon detection cell for carbon measurement.

After the detection process is complete, the remaining gas is discharged from the analyzer.

The measured carbon and sulfur concentrations are displayed by the analysis software as % C and % S. Analytical results are automatically stored in the system database for convenient future retrieval.

The software can also generate customized analysis reports when required. Reports can be printed through an external printer, supporting laboratory documentation and record keeping.

With its dual combustion furnace configuration, infrared detection technology, automated data processing, and straightforward operation, the QualiCSA™ 3G Carbon & Sulfur Analyzer provides rapid carbon and sulfur analysis for a wide range of solid materials while simplifying routine operation and maintenance.


High-Frequency Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3

Flexible Analytical Parameter Settings

The QualiCSA™ 3 High-Frequency Infrared Carbon & Sulfur Analyzer allows analytical parameters to be adjusted according to the characteristics and requirements of different specimens.

Calibration Methods and Parameters

Calibration methods and analytical parameters can be established and stored separately for different specimen types. The software supports an unlimited number of analytical methods, allowing laboratories to configure testing procedures for a wide range of materials.

Advanced Data Management

The QualiCSA™ 3 includes comprehensive data management functions designed to simplify analytical record keeping, data retrieval, reporting, and laboratory connectivity.

  • Database Storage: Analytical results are stored in a database for flexible data searches and statistical analysis.

  • Customizable Printing: Report and printing columns can be configured according to specific user requirements.

  • Excel Data Export: Current analytical data can be exported directly to Excel from the analysis interface.

  • LIMS Connectivity: Network-based data transmission supports integration with a Laboratory Information Management System (LIMS) for streamlined laboratory data management.

Carbon & Sulfur Analyzer

Automatic Cleaning of the High-Frequency Furnace

The QualiCSA™ 3 High-Frequency Infrared Carbon & Sulfur Analyzer features an integrated metal dust filtration system designed for convenient cleaning and efficient furnace operation.

  • Tool-Free Dust Filter Cleaning: The dedicated metal dust filter can be removed and cleaned without specialized tools, simplifying routine maintenance and reducing cleaning time.

  • Automatic Combustion Chamber Cleaning: The combustion chamber is automatically cleaned twice during the analysis process, with dust removed after each analysis cycle.

  • Automatic Filter Back-Blow: The dust filter is automatically back-blown to reduce dust accumulation and maintain effective filtration and adsorption performance.

  • Reduced Maintenance: Automated dust removal helps maintain stable combustion conditions and supports consistent carbon and sulfur analysis over repeated testing cycles.

Carbon & Sulfur Analyzer

Infrared Detection Unit

The QualiCSA™ 3 High-Frequency Infrared Carbon & Sulfur Analyzer features a non-dispersive infrared detection system with highly sensitive pyroelectric solid-state infrared detectors for carbon and sulfur analysis. The computer automatically calibrates the infrared cell zero point to support stable and accurate measurement.

  • Non-Dispersive Infrared Detection: High-sensitivity pyroelectric solid-state detectors provide reliable infrared signal measurement for carbon and sulfur analysis.

  • Automatic Zero Calibration: The software automatically calibrates the infrared cell zero point, helping maintain stable baseline conditions during analysis.

  • Three Independent Infrared Channels: The standard QualiCSA™ 3 configuration includes three independent infrared detection channels.

  • Expandable Detection Capacity: The system can be expanded to four independent infrared channels based on application requirements, supporting full-range carbon and sulfur detection.

Carbon & Sulfur Analyzer

Automatic Switching Between High and Low Ranges

The CS3500 Carbon & Sulfur Analyzer features advanced electronic flow control technology designed for rapid response and stable analysis gas flow. High-precision electronic flow regulation continuously supports controlled gas flow conditions, helping maintain measurement consistency and analytical accuracy.

The system's responsive flow control contributes to reliable switching and measurement across high and low detection ranges, supporting precise carbon and sulfur analysis across different concentration levels.

Carbon & Sulfur Analyzer

Carbon Sulfur Analyzer - QualiCSA™ 3 Working principle:

Carbon & Sulfur Analyzer

Structure of the Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3G

The QualiCSA™ 3G Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer features a modular instrument design that integrates the major components required for carbon and sulfur analysis. The system configuration includes an electronic balance, computer, printer, high-frequency induction combustion unit, tubular resistance furnace unit, vacuum cleaner, and other supporting modules.

This modular configuration provides a practical setup for laboratories performing carbon and sulfur analysis across different solid sample types.

Infrared Detection System

The QualiCSA™ 3G uses an infrared absorption detection system designed to provide flexible carbon and sulfur measurement according to application requirements.

  • Three-Channel Standard Configuration: The standard configuration includes three independent infrared absorption cells, providing three physical detection channels: two carbon channels and one sulfur channel.

  • Four-Channel Configuration: Based on application requirements, the QualiCSA™ 3G can be configured with four independent infrared absorption cells, providing two carbon channels and two sulfur channels for expanded detection capability.

  • Pyroelectric Infrared Detector: The analyzer uses a German-produced pyroelectric solid-state infrared detector for sensitive infrared signal detection.

  • Synchronous Motor: A Swiss-produced synchronous motor provides stable operation of the infrared detection system.

  • Infrared Light Source: A stable, oxidation-resistant infrared light source produced in the United States supports consistent optical performance.

  • Constant-Temperature Control: The entire infrared detection chamber is thermostatically controlled to maintain a stable analysis temperature, supporting measurement accuracy and detection stability.

  • Oxygen Shielding Gas: Oxygen is used to protect and purify the infrared light source and detector by isolating these components from the surrounding atmosphere. This helps improve analytical stability and detection accuracy.

Typical Data (tube furnace):

Name of the Specimen and Content of Carbon and Sulfur: C61.46; S4.34
Specimen ID Carbon Mass Fraction Sulfur Mass Fraction
1 61.486 4.410
2 61.286 4.385
3 61.506 4.435
4 61.518 4.293
5 61.471 4.354

Software Interface:

Carbon & Sulfur Analyzer

Main analysis Window

Carbon & Sulfur Analyzer

Method window

Carbon & Sulfur Analyzer – QualiCSA™ 3 Technical Specification

Carbon Sulfur Analyzer QualiCSA™ 3 and QualiCSA™ 3G Technical Specifications:

Model QualiCSA™ 3 QualiCSA™ 3G
Analysis Range

High-frequency induction furnace (500mg sample):

  • LC: 1ppm~0.1%
  • HC: 0.1%~5%
  • LS: 1ppm~0.3%
  • HS (150mg sample): 0.3%~30%

Note: Changing the sample size can extend the analysis range up to 100% High sulfur absorption pools channel can be customized according to customer needs

High Frequency Induction Furnace(500mg Sample):

  • LC: 1ppm - 0.1%
  • HC: 0.1%~5%
  • LS: 1ppm - 0.3%
  • HS (150mg Sample): 0.3%~ 30%

Tubular Resistance Furnace(500mg Sample):

  • C: 0.01% ~20%
  • S: 0.005% ~20%

Note: The measurement range can be changed by changing the measurement quantity.

The number of detection cells and sizes can be determined in accordance with the content of carbon and sulfur in specimens of users

     
   
     
Analysis Accuracy

High-frequency induction furnace:

  • LC: 1ppm or RSD ≤ 1%
  • HC: RSD ≤ 0.5%
  • LS: 1.5ppm or RSD ≤ 1.5%
  • HS: RSD ≤ 1.5%

High-Frequency Induction Furnace:

  • LC: 1ppm or RSD≤1%
  • HC: RSD≤0.5%
  • LS: 1.5ppm or RSD≤1.5%
  • HS: RSD≤1.5%

Tubular Resistance Furnace:

  • LC: RSD≤1%
  • HC: RSD≤0.5%
  • LS: RSD≤1.5%
  • HS: RSD≤1.5%
Sensitivity 0.01ppm
Analysis Time 40 ~ 60 seconds

High-Frequency Induction Furnace:

  • 40-60 seconds Tubular Resistance Furnace:
  • 150-300 seconds
Sample Quality

Recommended sample weight:

  • 0.1g to 0.5g, can be adjusted based on carbon and sulfur content

High-Frequency Induction Furnace:

  • 0.1g-0.5g Tubular Resistance Furnace:
  • 300mg/coal(typical value)
Combustion Furnace

High-frequency induction furnace:

  • 18MHz, 2.7KVA

High-Frequency Induction Furnace:

  • 18MHz 2.7KVA

Tubular Resistance Furnace:

  • Max.20A,Max.1550 ℃, the temperature can be adjusted continuously
Dust cleaning The dust in the combustion tube of the high frequency induction furnace is wiped off automatically
Detector Solid-state pyroelectric detector
Carrier Gas Oxygen purity: ≥ 99.5%; 0.2-0.4Mpa Oxygen 99.5%, 3L/min
Power Gas Nitrogen (industrial grade) Nitrogen or Compressed Air
Voltage

Power Supply of the Analyzer:

  • 220VAC±10% 50±1Hz 16A (110V is also available)

Power Supply of the Analyzer:

  • 220VAC ±10%,50±1Hz,16A (110V is also available)

Power Supply of the Resistance Furnace:

  • 220VAC ±10%, 50±1Hz, 20A (110V is also available)
Weight Approximately 100kg

High-Frequency Induction Furnace: 

  • 100kg

Tubular Resistance Furnace: 

  • 30k
Dimensions (width × depth × height) 55 × 76 × 77 cm

The Analyzer:

  • 55 x 77 x 76 (cm)

Resistance Furnace:

  • 33× 52 × 60 (cm)

Resolution of the Electronic Balance:

  • 0.1mg
Chemical Reagent   Magnesium perchlorate, CO2 absorbent

El plazo de entrega varía según la disponibilidad de stock. Nuestros plazos de envío estándar suelen ser de una semana; sin embargo, para algunos artículos de alta demanda, el plazo de entrega puede extenderse a dos o tres semanas. Si necesita estos artículos con urgencia, contáctenos para consultar la disponibilidad exacta de stock y organizar un envío más rápido.

🚚

Información importante sobre la entrega

El plazo de entrega varía según la disponibilidad de stock. Nuestros plazos de envío estándar suelen ser de una semana ; sin embargo, para algunos artículos de alta demanda, el plazo de entrega puede extenderse a dos o tres semanas .

¿Lo necesitas urgentemente? Contáctanos aquí para consultar existencias y organizar un envío más rápido.

Pedidos:
El comprador reconoce que al realizar un pedido en Qualitest:

A. la realización del pedido significa el consentimiento del comprador de realizar dicho pedido en Qualitest y que el pedido será aceptado una vez procesado exitosamente por Qualitest USA LC.
B. el hecho de que el comprador escriba su nombre cuando Qualitest se lo solicite constituye una firma del contrato.
C. el comprador tiene plena autoridad para celebrar el contrato para dicha entidad, y dicha concesión de autoridad fue indicada por el comprador mediante la colocación del pedido a través de Qualitest.
D. Se aplicará una tarifa de manipulación mínima al total del envío para todos los pedidos.

Envíos dentro de EE. UU.:

Todos los pedidos se enviarán con portes pagados, por mensajería para paquetes pequeños o mediante transportistas para cajas más grandes. Se podría aplicar un cargo por manejo. La propiedad de la mercancía se transfiere al comprador al momento de la entrega al transportista. Las pérdidas o daños durante el transporte son responsabilidad del comprador. Qualitest USA le brindará asistencia con la información necesaria para procesar las reclamaciones.

Envíos fuera de EE. UU.:

Todos los pedidos se enviarán de la mejor manera posible: por mensajería para paquetes pequeños o mediante transportistas para cajas más grandes. Podría aplicarse una tarifa de manejo baja. La propiedad de la mercancía se transfiere al comprador al momento de la entrega al transportista. Las pérdidas o daños durante el transporte son responsabilidad del comprador. Qualitest USA le brindará asistencia con la información necesaria para procesar las reclamaciones. Las tarifas de exportación, aranceles, impuestos y el despacho de aduanas son responsabilidad del comprador.

El seguro de envío no está incluido, comuníquese con nuestros representantes de ventas si necesita seguro de envío.

Envío parcial: Qualitest USA se reserva el derecho de realizar envíos parciales a menos que el comprador indique lo contrario.

Condiciones de pago: Todos los pagos a Qualitest USA deben realizarse en dólares estadounidenses (USD)

A. Tarjeta de crédito: Qualitest USA acepta Visa, MasterCard, AMEX o Discover. La información requerida del comprador es el número de tarjeta de crédito, el código de seguridad de 3 dígitos, la fecha de vencimiento, el nombre del titular (tal como aparece en la tarjeta), la dirección de facturación y un número de teléfono válido para que podamos usarlo en caso de cualquier problema. Qualitest USA se reserva el derecho de retrasar el envío hasta que se verifique la validez de la tarjeta de crédito.
B. Transferencia bancaria: La transferencia debe realizarse a nombre de Qualitest y confirmarse por el importe total de la compra (mercancía, manipulación y envío) antes del envío. Para obtener información bancaria, contáctenos por teléfono al 1.877.884.TEST (8378) (fuera de EE. UU.: +1.905.944.9825) o por fax al +1.954.697.8211.
C. Apertura de cuenta: Disponible solo para clientes de EE. UU. y Canadá. Las cuentas abiertas tienen una vigencia de 30 días a partir de la fecha de envío. Qualitest USA se reserva el derecho de rechazar el envío de nuevos pedidos si alguna factura impaga tiene más de 30 días de antigüedad. Los compradores pueden solicitar la apertura de una cuenta proporcionando:

su información bancaria
3 referencias crediticias de otros proveedores
Por favor, espere 5 días hábiles para la confirmación del crédito y la creación de una cuenta abierta.

Política de devoluciones:

Qualitest USA puede aceptar la devolución de mercancía comprada dentro de América del Norte para reembolso o crédito bajo las siguientes condiciones:

  • Es posible que se aplique una tarifa de reposición adicional a la transacción si los artículos ya se enviaron al cliente.
  • Los productos deben devolverse a Qualitest USA dentro de los 5 días posteriores a la fecha de recepción de los productos comprados.
  • Todos los gastos de envío, aranceles, aduanas y demás gastos relacionados con la mercancía devuelta correrán a cargo del comprador. Se rechazarán los envíos a portes debidos.
  • La mercancía debe devolverse debidamente embalada, en condiciones nuevas y aptas para la venta, junto con el embalaje original y toda la documentación, accesorios y certificados.
  • El comprador ha confirmado la autorización de devolución directamente con Qualitest.
  • La mercancía es un artículo de catálogo regular. Los artículos de pedidos especiales no se pueden devolver.
  • Toda mercancía devuelta está sujeta a inspección por Qualitest. Qualitest se reserva el derecho de rechazar la devolución de cualquier mercancía usada, dañada o que no se encuentre en la lista de precios publicada. En caso de que Qualitest no acepte la mercancía devuelta, se hará todo lo razonablemente posible para notificar al Comprador y la mercancía se le devolverá tal como la recibió. La mercancía dañada que pueda restaurarse a su estado original y, por lo tanto, sea aceptada para su devolución, se evaluará individualmente. Se informará al comprador de los gastos adicionales por la reparación y restauración del artículo devuelto. Tras la aprobación, estos gastos se le cobrarán al comprador, además de la tarifa de reposición.


Cambio de Términos:

La aceptación de cualquier pedido por parte de Qualitest USA está sujeta a la aceptación por parte del comprador de todos los términos y condiciones aquí establecidos. La aceptación por parte del comprador de estos términos y condiciones se presumirá desde el momento en que realice un pedido a través de Qualitest. Se rechazan expresamente todos los demás términos y condiciones, y ninguna adición o modificación de los mismos será vinculante sin el consentimiento previo por escrito de Qualitest USA.

Acuerdo completo:

Los términos y condiciones del sitio web de Qualitest, incorporados aquí por referencia, incluidos formularios, reconocimientos, cotizaciones, facturas y términos y condiciones de venta, constituyen el acuerdo completo y exclusivo entre el comprador y Qualitest USA LC.

Información:

Qualitest USA se esfuerza al máximo para garantizar la exactitud de la información de los productos que se muestra en sus sitios web, pero no ofrece garantías, expresas ni implícitas, sobre la exactitud de los datos presentados en ellos. Qualitest USA se reserva el derecho de modificar la información de los productos, incluyendo la información de precios, en cualquier momento y sin previo aviso.

Marcas comerciales y derechos de autor:

Qualitest, de WorldofTest.com, contiene nombres de productos registrados. Los nombres de productos no pueden ser reproducidos ni utilizados de ninguna manera por terceros ajenos a Qualitest sin el consentimiento expreso por escrito de Qualitest International Inc. Todas las imágenes, descripciones y demás contenido de este sitio web están protegidos por derechos de autor de Qualitest USA y no pueden utilizarse sin su autorización expresa por escrito. El comprador reconoce que no tiene ningún derecho, título ni interés sobre las marcas comerciales o los derechos de autor de los productos, y se compromete a no registrar ni interferir con dichos derechos. Contáctenos si tiene alguna solicitud de permiso o pregunta sobre nuestras marcas comerciales.

Descargo de responsabilidad de garantía:

Qualitest USA no otorga ni autoriza ninguna garantía ni afirmación de hecho, expresa o implícita, salvo lo establecido expresamente en este documento. Qualitest USA declina toda responsabilidad por reclamaciones por defectos del producto. Qualitest USA no garantiza, expresa ni implícitamente, que ningún producto del sitio web sea apto para un propósito específico. Qualitest USA respeta la garantía del producto publicada y puesta a disposición por Qualitest USA. Las reclamaciones de garantía de productos no fabricados por Qualitest son responsabilidad del fabricante. Qualitest USA siempre hará todo lo posible de buena fe para resolver las reclamaciones de garantía.


Fuerza mayor:

Qualitest USA no será responsable por ninguna demora o deterioro del rendimiento que resulte total o parcialmente de casos fortuitos, interrupciones del servicio, interrupciones laborales, insurrecciones, decretos o controles gubernamentales, riesgos de guerra, clima severo, suministros o materias primas, incapacidad para adquirir o enviar productos, incapacidad para obtener permisos y/o licencias, o cualquier otra circunstancia o causa fuera del control de Qualitest USA en la conducción de su negocio.

Política de privacidad de Qualitest USA 

I. ¿Qué disposiciones legales rigen nuestras prácticas de tratamiento de datos? ¿Cómo y de dónde (fuentes internas/externas) se obtienen los datos personales? ¿Cuáles son los derechos del usuario (visitante del sitio web/cliente registrado)? 

1. General
Como principio general, no es necesario proporcionar datos personales al visitar nuestro sitio web. Los datos que nos proporciona se tratan con estricta confidencialidad y de acuerdo con las disposiciones de la Ley Federal de Protección de Datos. Con algunas excepciones (véase el punto 2 a continuación), nuestro servidor web solo registra datos no personales (anónimos) sobre el uso de nuestro sitio. En concreto, los archivos de registro de nuestro servidor web, por regla general, solo contienen la dirección IP del usuario, la última página visitada, el navegador utilizado, la fecha, la hora y el archivo solicitado. Sin embargo, estos datos anónimos no permiten extraer conclusiones sobre los usuarios individuales y solo sirven para elaborar estadísticas sobre el uso de nuestro sitio web con el fin de mejorarlo. Al mismo tiempo, es fundamental garantizar que los datos de uso no se vinculen con datos personales.

2. Datos personales

Los datos personales solo se utilizan si se solicita el boletín informativo (por correo electrónico), se solicitan productos o se proporciona información sobre productos. Nos comprometemos a utilizar los datos personales que nos confíe únicamente para los fines indicados. El historial de compras se conserva para atender futuras necesidades del cliente.

II. ¿Qué medidas de seguridad se utilizan para proteger los datos personales? ¿Qué opciones tiene el usuario para procesar sus datos personales? 

3. Medidas técnicas

Las bases de datos están óptimamente protegidas contra el acceso, la pérdida, el uso indebido y la falsificación por parte de terceros mediante el uso de medios técnicos adecuados. Para determinar la popularidad de cada área temática, se utilizan cookies en dichas secciones. Estos archivos de texto se almacenan en su disco duro y facilitan el uso de nuestro sitio web. Gracias a estas cookies, no es necesario registrarse cada vez que visita una sección que lo requiere, y podemos ofrecerle el contenido personalizado que solicita.

Usted decide si desea trabajar con cookies y, en caso afirmativo, de qué tipo (almacenadas permanentemente en el disco duro o solo mientras navega). Sin embargo, le advertimos que el acceso a los campos que requieren registro solo es posible con las cookies activadas.

III. ¿Qué datos se comunican a terceros y con qué finalidades? 

4. Comunicación de datos personales

Los datos personales que usted nos confía no se comunican, alquilan ni venden a terceros.

IV. ¿Qué departamento responde preguntas sobre el tratamiento de datos personales? 

5. Contacto

Debido a los rápidos avances técnicos en internet, nos esforzamos al máximo para mejorar constantemente nuestro sitio web y las precauciones técnicas, incluyendo las relacionadas con la protección de datos. Le mantendremos informado sobre dichas medidas. Cualquier cambio se publicará aquí. Puede obtener más información en cualquier momento contactando con Qualitest USA.

Exención de responsabilidad. Qualitest USA no será responsable de las pérdidas directas, indirectas o consecuentes que resulten de o estén relacionadas con el acceso, uso o consultas al sitio web de Qualitest o sus enlaces con otros sitios web, incluso si Qualitest USA ha sido informado previamente de la posibilidad de dichas pérdidas. No se garantiza la exactitud de la información difundida a través del sitio web de Qualitest USA. Además, Qualitest USA no garantiza la fiabilidad ni la integridad de la información contenida en su sitio web. La información disponible en el sitio web de Qualitest y WorldofTest.com puede modificarse en cualquier momento sin previo aviso. En particular, Qualitest USA no será responsable de las pérdidas causadas por errores de transmisión, fallos técnicos e interrupciones, averías o una interferencia ilícita en el sistema de procesamiento de datos del usuario o en los sistemas y redes de transmisión de acceso general. Qualitest USA tampoco será responsable de las pérdidas resultantes de averías, interrupciones o sobrecargas que se produzcan en cualquier sistema de procesamiento de datos. Si se activan ciertos enlaces en los sitios web de Qualitest y WorldofTest.com, el usuario podría, en determinadas circunstancias, abandonar el sitio web de Qualitest. Qualitest USA no asume ninguna responsabilidad por el contenido, los productos o servicios ofrecidos, ni por ninguna otra información u ofertas contenidas en estos sitios web enlazados.

Productos relacionados