Carbon & Sulfur Analyzer

Carbon & Sulfur Analyzer (New)

Ir directamente a la información del producto
Carbon & Sulfur Analyzer
SKU:

Carbon & Sulfur Analyzer (New)

The QualiCSA™ 5 is a high-performance carbon and sulfur analyzer designed for rapid elemental quality control. Engineered for metallurgical, mining, and advanced material testing, it delivers ultra-precise measurement down to 0.01 ppm within 60 seconds without compromising on accuracy or global compliance.

  • 0.01 Ppm Ultra-Trace Sensitivity
  • Fast 60 Second Analysis Cycles
  • Up To 4 Infrared Channels
  • Powerful 13.56 MHz Induction Furnace

Obtenga precios personalizados para sus requisitos específicos

Carbon & Sulfur Analyzer (New) – QualiCSA™ 5

Carbon and sulfur analysis is an essential quality control step when material chemistry affects metal quality, weldability, and specification compliance. The QualiCSA™ 5 Carbon & Sulfur Analyzer is a high-frequency combustion system with infrared (IR) detection, designed to deliver fast, repeatable total carbon and sulfur results for solid inorganic samples. The brochure series includes two configurations: the general-purpose QualiCSA™ 5 and the geology and mineral-focused QualiCSA™ 5M.

The QualiCSA™ 5 combusts samples in an oxygen atmosphere using a high-frequency induction furnace. The resulting CO₂ and SO₂ gases are measured through multi-channel infrared detection cells. Integrated dust and moisture control, catalytic conversion, and stabilized gas-flow management help maintain consistent analytical performance across a wide range of sample matrices.

Designed for efficient laboratory workflows, the analyzer supports rapid testing cycles for production and quality control decisions. Its software provides tools for calibration, analytical method setup, result management, and data security, helping laboratories maintain reliable testing procedures and organized data records.

Optional configurations include a halogen trap, wet-sample handling system, and high-capacity autosampler, allowing laboratories to configure the QualiCSA™ 5 according to sample types, testing requirements, and laboratory throughput.

Carbon & Sulfur Analyzer (New) – QualiCSA™ 5 Applications

Steel, Cast Iron, and Alloy Quality Control

Carbon and sulfur analysis plays an important role in steel, cast iron, and alloy quality control, supporting grade verification, melt control, and final product release testing. Reliable low-level carbon and sulfur measurement is valuable for cleaner steel production, while broader analytical ranges support foundry and alloy manufacturing. Fast analysis helps laboratories make timely production decisions, minimize rework, and maintain consistent process control.

Non-Ferrous Metals and Superalloys

Non-ferrous metals and superalloys can require precise carbon and sulfur control due to their effects on material properties and downstream processing. High-frequency combustion with infrared (IR) detection provides rapid C/S analysis for production monitoring and incoming material inspection. Consistent gas handling helps maintain repeatable measurements during extended laboratory testing and high-volume workflows.

Cemented Carbides and Advanced Materials

Carbon concentration can influence phase balance and performance in cemented carbides and advanced engineered materials. Controlled combustion and consistent gas conditioning help produce comparable carbon and sulfur results across multiple batches. This makes the analyzer suitable for both materials research and development laboratories and production quality control environments using consistent analytical procedures.

Ores, Soil, Sand, Glass, and Mineral Samples

The mineral-focused QualiCSA™ 5M configuration is designed for challenging sample matrices, including powdery, moist, and potentially corrosive materials. Moisture control and corrosion protection help support stable long-term operation when analyzing complex mineral samples. Applications include iron ore, copper ore, bauxite, rare-metal ores, coal, fluorite, sandstone, soil, sand, and glass, as referenced in the brochure materials.

Standards

The QualiCSA™ 5 Carbon & Sulfur Analyzer supports laboratory workflows aligned with recognized international and industry testing standards for carbon and sulfur analysis:

  • ISO 15350: Specifies the determination of total carbon and sulfur in steel and related materials through combustion in an induction furnace followed by infrared absorption measurement.

  • ASTM E1019: Covers analytical methods for determining carbon and sulfur in steel, iron, nickel, cobalt, and related alloys using instrumental techniques.

  • ISO/IEC 17025: Provides a framework for laboratory competence, including validated testing methods, measurement traceability, quality control, and reliable analytical results.

Carbon & Sulfur Analyzer (New) – QualiCSA™ 5 Key Features

Infrared Detection System

Carbon & Sulfur Analyzer

  • Dual-Analog High-Order Signal Processing: The QualiCSA™ 5 uses a dual-analog, high-order infrared signal path with filter-based processing. Elliptic analog filtering helps reduce sampling errors associated with purely digital filtering approaches.

  • Three Standard IR Channels: The analyzer includes three independent infrared channels as standard, consisting of two carbon channels and one low-sulfur channel. An optional high-sulfur channel expands the system to four IR channels for broader sulfur measurement capability.

  • Pyroelectric Solid-State Detectors: Infrared detectors feature pyroelectric solid-state sensing elements with a structured optical configuration and analog processing circuitry, supporting stable signal detection during carbon and sulfur analysis.

  • Synchronous Optical Chopper: A synchronous chopper motor with controlled operation maintains consistent optical modulation for continuous infrared measurement and reliable analytical performance.

  • Stable IR Light Sources: The infrared light sources are selected to provide consistent optical output and resistance to oxidation, supporting dependable operation during extended laboratory use.

  • Temperature-Controlled Gas Chamber: The gas chamber uses temperature control to maintain stable analytical gas conditions throughout the measurement process, helping improve measurement consistency.

  • Protective Positive-Pressure Environment: The infrared source and detector area operates under slight positive pressure with purified protective gas. This configuration helps minimize the influence of ambient atmospheric conditions on infrared measurements.

High-Efficiency Extraction System

Carbon & Sulfur Analyzer

  • Three-Function Extraction System: The analyzer features an integrated extraction design combining furnace chamber pre-purge, direct ash discharge, and dual-brush automatic cleaning to support efficient sample processing and routine maintenance.

  • Flexible Analytical Methods: Programmable analytical routines allow testing parameters to be configured for different sample types, helping laboratories establish suitable measurement methods for varied carbon and sulfur applications.

  • Optimized Dust Removal: The gas-path design is configured with reduced dead volume to help limit dust accumulation and minimize adsorption and desorption effects that could influence analytical results.

  • Automatic Leak Detection: An integrated leak-check function monitors carrier-gas pressure to identify potential gas-path leaks. This helps improve measurement reliability while making routine maintenance and troubleshooting more straightforward.

  • Corrosion-Resistant Gas Path: Protective materials and design features help reduce corrosion risks caused by aggressive combustion byproducts, supporting long-term gas-path durability.

  • Integrated Hardware Safety: Safety features include an anti-pinch furnace head design, controlled air-pressure operation, and automatic shutdown during power loss, helping protect laboratory personnel and equipment during routine operation and unexpected interruptions.

High-Frequency Combustion Furnace System

Carbon & Sulfur Analyzer

  • Efficient Dual-Chamber Furnace Design: The QualiCSA™ 5 features an efficient heat source with a dual-chamber, shielded furnace structure. Air-cooled observation windows and protected furnace tubing help support stable operation during continuous carbon and sulfur analysis.

  • 13.56 MHz High-Frequency Power: Operating at 13.56 MHz with adjustable power up to 2.7 kVA, the induction furnace provides the high-temperature combustion conditions required for complete combustion of diverse inorganic solid samples.

  • Stable High-Frequency Power Supply: An integrated power-supply isolation design combined with a feed-through capacitor configuration helps reduce electrical crosstalk and maintain stable high-frequency output during analysis.

  • Waveguide Radiation Shielding: Built-in waveguide shielding helps control high-frequency electromagnetic emissions around the furnace system, supporting safer laboratory operation in accordance with the radiation limits referenced in the brochure.

Flow Control System

Carbon & Sulfur Analyzer

  • Micro-Pressure Differential Control: The QualiCSA™ 5 uses micro-pressure differential control combined with high-precision electronic flow regulation to maintain stable analytical gas flow during carbon and sulfur measurement.

  • Fast PID Flow Stabilization: A PID-based control system enables rapid stabilization of gas flow, helping laboratories begin analytical testing quickly after instrument startup.

  • Automatic Gas-Saving Standby Mode: An automatic standby function reduces gas consumption when the analyzer is idle, helping improve operational efficiency during periods without active testing.

  • Optimized Gas-Path Routing: Valve-based gas routing is designed to simplify the analytical gas path, reduce dead volume, and support stable gas movement throughout measurement cycles for consistent carbon and sulfur analysis.

User-Friendly Software

Carbon & Sulfur Analyzer

  • Digital-Twin Style User Interface: The software interface provides a visual overview of instrument status, analytical trends, and operational guidance, helping users monitor testing and maintenance activities from a centralized dashboard.

  • Integrated Guidance and Reference Content: Built-in guidance and reference information provides on-demand support for routine instrument operation, analytical procedures, and servicing tasks.

  • Flexible Method Configuration: The software supports multiple analytical routines with streamlined method configuration, making it suitable for routine production quality control and laboratory carbon and sulfur analysis.

  • Two Analytical Operating Modes: The QualiCSA™ 5 provides two operating modes for different testing requirements:

    • Fast Analysis Mode: Combines furnace pre-purge with direct ash discharge to reduce reset and cycle time for faster testing workflows.

    • Standard Analysis Mode: Combines direct ash discharge with dual-brush automatic cleaning to help reduce residual dust between consecutive analyses.

  • Automatic Measurement Range Switching: The analyzer automatically switches between high- and low-range measurement channels, providing expanded analytical range coverage for different carbon and sulfur concentrations.

  • Multiple Calibration Functions: Calibration workflows include single-point, basic, multi-point, and blank calibration, giving laboratories flexibility when establishing and maintaining analytical methods.

  • USB-Key Access Control: USB-key security provides controlled instrument access. Analytical operation is disabled when the designated USB key is removed.

  • Multi-Parameter Compensation: Integrated compensation algorithms help reduce environmental effects on analytical results, including:

    • CO Compensation: Corrects the influence of carbon monoxide on carbon measurement results.

    • Atmospheric Pressure Compensation: Helps reduce measurement variation associated with changes in atmospheric pressure.

Theory and Method

The QualiCSA™ 5 Carbon & Sulfur Analyzer determines carbon and sulfur concentrations through high-frequency induction combustion in an oxygen atmosphere, followed by infrared (IR) detection. During combustion, carbon-containing components are converted into carbon monoxide (CO) and carbon dioxide (CO₂), while sulfur is converted into sulfur dioxide (SO₂).

The combustion gases then pass through integrated dust removal and moisture control stages to condition the gas stream before infrared measurement. Carbon monoxide is subsequently converted into carbon dioxide to support complete carbon measurement. Multi-channel infrared cells measure the absorption signals associated with CO₂ and SO₂, while the analytical software processes these signals against calibrated curves to determine total carbon and sulfur concentrations.

Gas Flow Path and IR Detection

The diagram illustrates the internal gas flow path of the QualiCSA™ 5 Carbon & Sulfur Analyzer during high-frequency combustion and infrared detection. It shows the sequence of oxygen control, sample combustion, combustion-gas purification and drying, and infrared signal measurement.

After combustion, the conditioned gas travels through the analytical gas path to the dedicated CO₂ and SO₂ infrared detection cells. The measured infrared signals are processed by the analyzer software to calculate carbon and sulfur concentrations before the gas is directed to the exhaust system.

Working Principle

Carbon & Sulfur Analyzer

QualiCSA™ 5 Gas Flow Path and IR Detection Process

1. Oxygen Supply and Pressure Control

The QualiCSA™ 5 begins the analytical process with controlled oxygen delivery to maintain stable combustion and gas-flow conditions.

  • Total Oxygen Pressure Reducing Valve: Regulates the incoming oxygen pressure to maintain consistent gas flow throughout the analytical process.

  • Carrier Gas Purification: Removes contaminants from the oxygen supply that could interfere with low-ppm carbon and sulfur measurements.

  • Total Oxygen Valve: Provides the primary on/off control for oxygen entering the analyzer.

2. Oxygen Routing to the Furnace

Two controlled oxygen paths direct gas to the combustion zone to support efficient sample combustion and consistent gas transport.

  • Oxygen Lance Valve: Controls the oxygen supply used for combustion support and analytical gas transport.

  • Furnace Lance Valve: Directs oxygen into the furnace chamber to support complete combustion of the sample.

  • Backblow Valve: Provides a brief reverse-flow oxygen function when required, helping clear the gas lines and reduce dust carryover into the analytical gas path.

3. Dust Capture and Moisture Removal

Following combustion, the hot gas passes through dedicated conditioning components before reaching the infrared detection system.

  • Dust Filter: Captures combustion ash and particulate matter to help protect the downstream gas path and optical components.

  • Drying Tube: Removes water vapor from the combustion gas, helping prevent infrared signal drift or saturation during measurement.

Together, these stages help condition the gas stream and support consistent results from one sample to the next.

4. Post-Furnace Switching and Purge Functions

Controlled gas routing after the furnace manages the transition from combustion to measurement and supports rapid system reset between analyses.

  • Post-Furnace Valve: Controls gas routing into the measurement stage.

  • Flushing Valve (Emptying): Purges and resets the analytical gas path between tests, helping prepare the system for the next sample.

  • Carrier Gas Purification: An additional purification stage can further condition the gas stream before infrared measurement.

5. Flow Control and Infrared Detection

The Flow Control system maintains consistent gas movement through the measurement chamber. Stable gas flow is important for repeatable infrared absorption measurements because changes in gas volume and flow conditions can affect the measured signal.

The measurement chamber contains multiple infrared detection channels:

  • LC / HC: Low- and high-range carbon channels

  • LS / HS: Low- and high-range sulfur channels

This multi-channel configuration provides a broad analytical range. Low-range channels can be used for trace concentrations, while high-range channels support samples with higher carbon or sulfur concentrations.

6. Purification, Catalytic Conversion, and Exhaust

Before the processed gas exits the analyzer, additional treatment stages help prepare the gas for discharge.

  • Purification Tube: Further conditions the gas stream and helps protect downstream components.

  • Catalytic Furnace: Converts gases as required for accurate carbon measurement and supports cleaner gas handling before exhaust.

  • Discharging Valve: Controls the final release of processed gas from the instrument.

Why the Gas Flow Process Matters

Each stage of the QualiCSA™ 5 gas path contributes to stable and repeatable carbon and sulfur analysis:

  • Clean, dry analytical gas: Purification, dust filtration, and moisture removal help support stable low-ppm measurements.

  • Consistent gas flow: Controlled flow conditions help produce repeatable infrared absorption signals.

  • Wide analytical range: Dedicated low- and high-range carbon and sulfur channels provide expanded concentration coverage without hardware reconfiguration.

  • Efficient cycle reset: Controlled flushing and gas routing help clear the analytical path and prepare the analyzer for subsequent measurements.

Carbon & Sulfur Analyzer (New) – QualiCSA™ 5 Technical Specification

Performance and Measurement

Specification QualiCSA™ 5 QualiCSA™ 5M
Method High-frequency combustion + IR detection
Carbon range (1000 mg sample) 0.6 ppm to 6.0% (0.0006–60 mg absolute mass)
Sulfur range (1000 mg sample) 0.6 ppm to 6.0% (0.0006–60 mg absolute mass)
Range expansion By changing sample weight, range can extend up to 100%
Accuracy C: 0.3 ppm or RSD ≤ 0.5% / S: 0.3 ppm or RSD ≤ 0.5%
Sensitivity 0.01 ppm
Fastest analysis cycle 60 seconds
Recommended sample mass 0.1 g to 0.5 g (adjust by content)

Furnace, Gas, and Electrical

Specification QualiCSA™ 5 QualiCSA™ 5M
Combustion furnace 13.56 MHz, 2.7 kVA, adjustable power
Carrier gas Oxygen purity ≥ 99.5%
Power gas Nitrogen or other safety gases
Voltage 220 VAC ±10%, 50 ±1 Hz, 16 A (110V is also available)

Physical

Specification QualiCSA™ 5 QualiCSA™ 5M
Dimensions (W × D × H) 620 × 760 × 800 mm
Weight 120 kg

Capability Differences

Capability area QualiCSA™ 5 QualiCSA™ 5M
Intended sample focus General-purpose inorganic solids, metals, alloys Geological/mineral samples and complex matrices
Moisture handling emphasis Supports direct wet sample introduction via physical dehydration option Stronger focus on moisture elimination for wet/powdery mineral-style samples
Dust and contamination burden High-efficiency dust removal and self-cleaning design Enhanced dust removal emphasis for heavy dust loads typical in mineral matrices
Corrosive byproducts tolerance Corrosion-resistant gas path design Corrosion protection emphasis for harsher matrices and longer continuous runs
Typical use environment Metallurgical QC + mixed lab applications Mining, geology, mineral labs, and high-load production testing environments

El plazo de entrega varía según la disponibilidad de stock. Nuestros plazos de envío estándar suelen ser de una semana; sin embargo, para algunos artículos de alta demanda, el plazo de entrega puede extenderse a dos o tres semanas. Si necesita estos artículos con urgencia, contáctenos para consultar la disponibilidad exacta de stock y organizar un envío más rápido.

🚚

Información importante sobre la entrega

El plazo de entrega varía según la disponibilidad de stock. Nuestros plazos de envío estándar suelen ser de una semana ; sin embargo, para algunos artículos de alta demanda, el plazo de entrega puede extenderse a dos o tres semanas .

¿Lo necesitas urgentemente? Contáctanos aquí para consultar existencias y organizar un envío más rápido.

Pedidos:
El comprador reconoce que al realizar un pedido en Qualitest:

A. la realización del pedido significa el consentimiento del comprador de realizar dicho pedido en Qualitest y que el pedido será aceptado una vez procesado exitosamente por Qualitest USA LC.
B. el hecho de que el comprador escriba su nombre cuando Qualitest se lo solicite constituye una firma del contrato.
C. el comprador tiene plena autoridad para celebrar el contrato para dicha entidad, y dicha concesión de autoridad fue indicada por el comprador mediante la colocación del pedido a través de Qualitest.
D. Se aplicará una tarifa de manipulación mínima al total del envío para todos los pedidos.

Envíos dentro de EE. UU.:

Todos los pedidos se enviarán con portes pagados, por mensajería para paquetes pequeños o mediante transportistas para cajas más grandes. Se podría aplicar un cargo por manejo. La propiedad de la mercancía se transfiere al comprador al momento de la entrega al transportista. Las pérdidas o daños durante el transporte son responsabilidad del comprador. Qualitest USA le brindará asistencia con la información necesaria para procesar las reclamaciones.

Envíos fuera de EE. UU.:

Todos los pedidos se enviarán de la mejor manera posible: por mensajería para paquetes pequeños o mediante transportistas para cajas más grandes. Podría aplicarse una tarifa de manejo baja. La propiedad de la mercancía se transfiere al comprador al momento de la entrega al transportista. Las pérdidas o daños durante el transporte son responsabilidad del comprador. Qualitest USA le brindará asistencia con la información necesaria para procesar las reclamaciones. Las tarifas de exportación, aranceles, impuestos y el despacho de aduanas son responsabilidad del comprador.

El seguro de envío no está incluido, comuníquese con nuestros representantes de ventas si necesita seguro de envío.

Envío parcial: Qualitest USA se reserva el derecho de realizar envíos parciales a menos que el comprador indique lo contrario.

Condiciones de pago: Todos los pagos a Qualitest USA deben realizarse en dólares estadounidenses (USD)

A. Tarjeta de crédito: Qualitest USA acepta Visa, MasterCard, AMEX o Discover. La información requerida del comprador es el número de tarjeta de crédito, el código de seguridad de 3 dígitos, la fecha de vencimiento, el nombre del titular (tal como aparece en la tarjeta), la dirección de facturación y un número de teléfono válido para que podamos usarlo en caso de cualquier problema. Qualitest USA se reserva el derecho de retrasar el envío hasta que se verifique la validez de la tarjeta de crédito.
B. Transferencia bancaria: La transferencia debe realizarse a nombre de Qualitest y confirmarse por el importe total de la compra (mercancía, manipulación y envío) antes del envío. Para obtener información bancaria, contáctenos por teléfono al 1.877.884.TEST (8378) (fuera de EE. UU.: +1.905.944.9825) o por fax al +1.954.697.8211.
C. Apertura de cuenta: Disponible solo para clientes de EE. UU. y Canadá. Las cuentas abiertas tienen una vigencia de 30 días a partir de la fecha de envío. Qualitest USA se reserva el derecho de rechazar el envío de nuevos pedidos si alguna factura impaga tiene más de 30 días de antigüedad. Los compradores pueden solicitar la apertura de una cuenta proporcionando:

su información bancaria
3 referencias crediticias de otros proveedores
Por favor, espere 5 días hábiles para la confirmación del crédito y la creación de una cuenta abierta.

Política de devoluciones:

Qualitest USA puede aceptar la devolución de mercancía comprada dentro de América del Norte para reembolso o crédito bajo las siguientes condiciones:

  • Es posible que se aplique una tarifa de reposición adicional a la transacción si los artículos ya se enviaron al cliente.
  • Los productos deben devolverse a Qualitest USA dentro de los 5 días posteriores a la fecha de recepción de los productos comprados.
  • Todos los gastos de envío, aranceles, aduanas y demás gastos relacionados con la mercancía devuelta correrán a cargo del comprador. Se rechazarán los envíos a portes debidos.
  • La mercancía debe devolverse debidamente embalada, en condiciones nuevas y aptas para la venta, junto con el embalaje original y toda la documentación, accesorios y certificados.
  • El comprador ha confirmado la autorización de devolución directamente con Qualitest.
  • La mercancía es un artículo de catálogo regular. Los artículos de pedidos especiales no se pueden devolver.
  • Toda mercancía devuelta está sujeta a inspección por Qualitest. Qualitest se reserva el derecho de rechazar la devolución de cualquier mercancía usada, dañada o que no se encuentre en la lista de precios publicada. En caso de que Qualitest no acepte la mercancía devuelta, se hará todo lo razonablemente posible para notificar al Comprador y la mercancía se le devolverá tal como la recibió. La mercancía dañada que pueda restaurarse a su estado original y, por lo tanto, sea aceptada para su devolución, se evaluará individualmente. Se informará al comprador de los gastos adicionales por la reparación y restauración del artículo devuelto. Tras la aprobación, estos gastos se le cobrarán al comprador, además de la tarifa de reposición.


Cambio de Términos:

La aceptación de cualquier pedido por parte de Qualitest USA está sujeta a la aceptación por parte del comprador de todos los términos y condiciones aquí establecidos. La aceptación por parte del comprador de estos términos y condiciones se presumirá desde el momento en que realice un pedido a través de Qualitest. Se rechazan expresamente todos los demás términos y condiciones, y ninguna adición o modificación de los mismos será vinculante sin el consentimiento previo por escrito de Qualitest USA.

Acuerdo completo:

Los términos y condiciones del sitio web de Qualitest, incorporados aquí por referencia, incluidos formularios, reconocimientos, cotizaciones, facturas y términos y condiciones de venta, constituyen el acuerdo completo y exclusivo entre el comprador y Qualitest USA LC.

Información:

Qualitest USA se esfuerza al máximo para garantizar la exactitud de la información de los productos que se muestra en sus sitios web, pero no ofrece garantías, expresas ni implícitas, sobre la exactitud de los datos presentados en ellos. Qualitest USA se reserva el derecho de modificar la información de los productos, incluyendo la información de precios, en cualquier momento y sin previo aviso.

Marcas comerciales y derechos de autor:

Qualitest, de WorldofTest.com, contiene nombres de productos registrados. Los nombres de productos no pueden ser reproducidos ni utilizados de ninguna manera por terceros ajenos a Qualitest sin el consentimiento expreso por escrito de Qualitest International Inc. Todas las imágenes, descripciones y demás contenido de este sitio web están protegidos por derechos de autor de Qualitest USA y no pueden utilizarse sin su autorización expresa por escrito. El comprador reconoce que no tiene ningún derecho, título ni interés sobre las marcas comerciales o los derechos de autor de los productos, y se compromete a no registrar ni interferir con dichos derechos. Contáctenos si tiene alguna solicitud de permiso o pregunta sobre nuestras marcas comerciales.

Descargo de responsabilidad de garantía:

Qualitest USA no otorga ni autoriza ninguna garantía ni afirmación de hecho, expresa o implícita, salvo lo establecido expresamente en este documento. Qualitest USA declina toda responsabilidad por reclamaciones por defectos del producto. Qualitest USA no garantiza, expresa ni implícitamente, que ningún producto del sitio web sea apto para un propósito específico. Qualitest USA respeta la garantía del producto publicada y puesta a disposición por Qualitest USA. Las reclamaciones de garantía de productos no fabricados por Qualitest son responsabilidad del fabricante. Qualitest USA siempre hará todo lo posible de buena fe para resolver las reclamaciones de garantía.


Fuerza mayor:

Qualitest USA no será responsable por ninguna demora o deterioro del rendimiento que resulte total o parcialmente de casos fortuitos, interrupciones del servicio, interrupciones laborales, insurrecciones, decretos o controles gubernamentales, riesgos de guerra, clima severo, suministros o materias primas, incapacidad para adquirir o enviar productos, incapacidad para obtener permisos y/o licencias, o cualquier otra circunstancia o causa fuera del control de Qualitest USA en la conducción de su negocio.

Política de privacidad de Qualitest USA 

I. ¿Qué disposiciones legales rigen nuestras prácticas de tratamiento de datos? ¿Cómo y de dónde (fuentes internas/externas) se obtienen los datos personales? ¿Cuáles son los derechos del usuario (visitante del sitio web/cliente registrado)? 

1. General
Como principio general, no es necesario proporcionar datos personales al visitar nuestro sitio web. Los datos que nos proporciona se tratan con estricta confidencialidad y de acuerdo con las disposiciones de la Ley Federal de Protección de Datos. Con algunas excepciones (véase el punto 2 a continuación), nuestro servidor web solo registra datos no personales (anónimos) sobre el uso de nuestro sitio. En concreto, los archivos de registro de nuestro servidor web, por regla general, solo contienen la dirección IP del usuario, la última página visitada, el navegador utilizado, la fecha, la hora y el archivo solicitado. Sin embargo, estos datos anónimos no permiten extraer conclusiones sobre los usuarios individuales y solo sirven para elaborar estadísticas sobre el uso de nuestro sitio web con el fin de mejorarlo. Al mismo tiempo, es fundamental garantizar que los datos de uso no se vinculen con datos personales.

2. Datos personales

Los datos personales solo se utilizan si se solicita el boletín informativo (por correo electrónico), se solicitan productos o se proporciona información sobre productos. Nos comprometemos a utilizar los datos personales que nos confíe únicamente para los fines indicados. El historial de compras se conserva para atender futuras necesidades del cliente.

II. ¿Qué medidas de seguridad se utilizan para proteger los datos personales? ¿Qué opciones tiene el usuario para procesar sus datos personales? 

3. Medidas técnicas

Las bases de datos están óptimamente protegidas contra el acceso, la pérdida, el uso indebido y la falsificación por parte de terceros mediante el uso de medios técnicos adecuados. Para determinar la popularidad de cada área temática, se utilizan cookies en dichas secciones. Estos archivos de texto se almacenan en su disco duro y facilitan el uso de nuestro sitio web. Gracias a estas cookies, no es necesario registrarse cada vez que visita una sección que lo requiere, y podemos ofrecerle el contenido personalizado que solicita.

Usted decide si desea trabajar con cookies y, en caso afirmativo, de qué tipo (almacenadas permanentemente en el disco duro o solo mientras navega). Sin embargo, le advertimos que el acceso a los campos que requieren registro solo es posible con las cookies activadas.

III. ¿Qué datos se comunican a terceros y con qué finalidades? 

4. Comunicación de datos personales

Los datos personales que usted nos confía no se comunican, alquilan ni venden a terceros.

IV. ¿Qué departamento responde preguntas sobre el tratamiento de datos personales? 

5. Contacto

Debido a los rápidos avances técnicos en internet, nos esforzamos al máximo para mejorar constantemente nuestro sitio web y las precauciones técnicas, incluyendo las relacionadas con la protección de datos. Le mantendremos informado sobre dichas medidas. Cualquier cambio se publicará aquí. Puede obtener más información en cualquier momento contactando con Qualitest USA.

Exención de responsabilidad. Qualitest USA no será responsable de las pérdidas directas, indirectas o consecuentes que resulten de o estén relacionadas con el acceso, uso o consultas al sitio web de Qualitest o sus enlaces con otros sitios web, incluso si Qualitest USA ha sido informado previamente de la posibilidad de dichas pérdidas. No se garantiza la exactitud de la información difundida a través del sitio web de Qualitest USA. Además, Qualitest USA no garantiza la fiabilidad ni la integridad de la información contenida en su sitio web. La información disponible en el sitio web de Qualitest y WorldofTest.com puede modificarse en cualquier momento sin previo aviso. En particular, Qualitest USA no será responsable de las pérdidas causadas por errores de transmisión, fallos técnicos e interrupciones, averías o una interferencia ilícita en el sistema de procesamiento de datos del usuario o en los sistemas y redes de transmisión de acceso general. Qualitest USA tampoco será responsable de las pérdidas resultantes de averías, interrupciones o sobrecargas que se produzcan en cualquier sistema de procesamiento de datos. Si se activan ciertos enlaces en los sitios web de Qualitest y WorldofTest.com, el usuario podría, en determinadas circunstancias, abandonar el sitio web de Qualitest. Qualitest USA no asume ninguna responsabilidad por el contenido, los productos o servicios ofrecidos, ni por ninguna otra información u ofertas contenidas en estos sitios web enlazados.

Productos relacionados