Automatic Melt Flow Indexer (MFI)

Automatic Melt Flow Indexer (MFI)

Ir directamente a la información del producto
Automatic Melt Flow Indexer (MFI)
En stock
SKU:

Automatic Melt Flow Indexer (MFI)

  • Wide 50–450 °C Operating Temperature Range
  • High 3000 cm³/10min MVR Capacity
  • Precise 0.0005 Second Digital Timer
  • Large 5,000-Group Data Memory

Obtenga precios personalizados para sus requisitos específicos

Automatic Melt Flow Indexer (MFI) — QualiFi™ 6000A

Flagship Fully Automatic MFI System with Software-Controlled Variable Load and Pneumatic Operation

The QualiFi™ 6000A is a high-performance automatic melt flow indexer designed for advanced laboratories and quality control facilities that require precise automation, strong measurement reliability, and enhanced operational safety in thermoplastic melt flow testing. It features a software-driven weight selection system with variable load capability, complete pneumatic control for sample compaction, residual material extrusion, and barrel cleaning, along with a 10.1-inch high-definition touchscreen interface.

This model delivers both Melt Mass Flow Rate (MFR) and Melt Volume Flow Rate (MVR) testing across a broad operating range of 50–450 °C, supporting flow measurements from 0.1–100 g/10 min (MFR) and 0.01–3,000 cm³/10 min (MVR). This extensive range represents the widest testing capability within the QualiFi™ melt flow indexer series.

Positioned at the top of the QualiFi™ lineup, the 6000A stands apart from the 4000A and 5000A models through its software-controlled multi-weight selection system with variable load functionality, enabling fully programmable multi-stage load changes within a single test cycle. Automatic weight lifting and lowering, pneumatic sample handling and cleaning, a built-in safety guard for weight control, and a protective barrier between the furnace and loading system collectively reduce manual intervention and improve consistency throughout testing—from sample loading to final data export.

The QualiFi™ 6000A has been part of CNAS inter-laboratory proficiency testing programs for several consecutive years, consistently achieving Z-scores within the ±0.11 range. These results reflect highly stable measurement performance aligned with internationally recognized reference standards.

Automatic Melt Flow Indexer (MFI) — QualiFi™ 6000A Applications

The QualiFi™ 6000A melt flow indexer is designed for quality control, research and development, and incoming material inspection workflows in any laboratory or industrial setting where thermoplastic melt flow properties are a key specification or process control parameter.

Plastic Raw Material Production & Quality Control

Used for incoming raw material inspection, batch consistency checks, and production quality monitoring in polymer manufacturing environments. The software-driven variable load system and 8-group stored test program capability allow quick switching between test conditions for different resin grades without repeated manual setup. This supports efficient, high-throughput testing where melt flow index is a critical acceptance parameter.

Engineering Plastics Testing

Suitable for melt flow measurement of high-temperature engineering polymers such as polycarbonate (PC), polyamide (PA), fluoropolymers, and polyoxymethylene (POM), operating across a full 50–450 °C range. Independent multi-zone temperature control with ±0.1 °C stability ensures consistent thermal conditions required for accurate testing of advanced engineering materials.

Polyolefin & Commodity Polymer Testing

Provides reliable MFR and MVR measurement for polyethylene (PE), polypropylene (PP), polystyrene (PS), ABS, and similar thermoplastics under standard testing conditions. Automated weight handling and software-based load selection reduce manual steps and help maintain consistency in routine melt flow index testing.

Pharmaceutical & Medical-Grade Polymer Testing

Supports melt flow evaluation of medical and pharmaceutical-grade polymers used in regulated applications. Built-in user access control, 5,000-test USB data storage, DMS data management software, and optional PC connectivity enable structured data handling and traceable documentation for compliance requirements.

Petrochemical Industry & Refinery QC

Used for verifying polymer consistency in petrochemical production and refinery environments where stable melt flow behavior is essential for downstream processing. The corrosion-resistant surface treatment and reinforced aluminum structure support long-term operation in demanding laboratory conditions.

Research Institutions & Universities

Ideal for academic research, polymer development studies, and comparative melt flow analysis. The system supports both MVR-based and calculated MFR methods, enabling direct comparison between measurement approaches for advanced material characterization studies.

Commodity Inspection & Certification Laboratories

Applied in third-party testing, certification, and regulatory compliance environments. Alignment with ISO 1133 and ASTM D1238 standards, combined with CNAS proficiency testing history and CE certification, ensures suitability for accredited laboratories requiring traceable and standardized melt flow measurements.

Standards Compliance

The QualiFi™ 6000A melt flow indexer is engineered and manufactured in accordance with internationally recognized standards governing thermoplastic melt flow testing, laboratory instrument safety, and electromagnetic compatibility.

ISO 1133
Plastics — Determination of melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics. This serves as the primary international standard defining test procedures, measurement principles, and performance expectations for melt flow index testing systems.

ASTM D1238
Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer. This is the key North American reference standard for MFR and MVR determination and defines operational procedures for melt flow index instruments.

EN 61010-1:2010+A1:2019
Safety requirements for electrical equipment used in measurement, control, and laboratory environments. This standard supports CE compliance for electrical and operational safety in laboratory instruments.

EN 61326-1:2013
Electromagnetic compatibility requirements for measurement, control, and laboratory equipment. Ensures stable performance of the instrument in environments with electromagnetic interference.

CE Marking
The QualiFi™ 6000A carries CE marking, confirming compliance with applicable European Union directives for safety, health, and environmental protection requirements related to laboratory measurement and control equipment.

Certifications & Proficiency Verification

The QualiFi™ 6000SA is built on the validated QualiFi™ Series platform and shares the same certification framework and performance verification standards applied across the product family, including CE compliance and CNAS inter-laboratory testing participation.

CE Certification
Complies with EN 61010-1:2010+A1:2019 (Low Voltage Directive) and EN 61326-1:2013 (Electromagnetic Compatibility). Conformity is verified through ECM Certificate of Compliance, confirming adherence to essential safety and EMC requirements for laboratory measurement equipment.

CNAS Proficiency Testing
Participates in consecutive CNAS inter-laboratory proficiency testing programs with consistently satisfactory outcomes. Recorded Z-scores remain within −0.07 to +0.11 across all evaluation rounds, demonstrating stable measurement performance and strong inter-laboratory comparability.

Technical Patents
The QualiFi™ Series incorporates multiple registered patents covering key innovations in measurement technology, thermal control systems, and instrument design architecture, supporting enhanced testing precision and operational reliability.

Automatic Melt Flow Indexer (MFI) — QualiFi™ 6000A Key Features

Instrument Design & Construction

The QualiFi™ 6000A is engineered with a focus on durability, operational safety, and efficient laboratory ergonomics, making it suitable for both intensive quality control and research environments.

All-Aluminum Body with Advanced Surface Treatment
The instrument is built on a full aluminum structure with enhanced surface finishing technology, delivering strong mechanical durability and resistance to corrosion, including salt spray conditions. This construction supports stable performance in demanding laboratory and production quality control settings.

Trapezoidal Barrel Design with 15° Tilt
An innovative trapezoidal barrel layout combined with a 15° inclined body and upper rotating mechanism ensures a compact system footprint while improving workflow accessibility. This ergonomic design allows easier access for sample loading and operation, optimizing space efficiency in laboratory setups.

Integrated Thermal Insulation System
The unit incorporates eco-conscious, molded thermal insulation integrated into the structure. This design improves heat retention within the furnace, stabilizes temperature conditions and contributes to reduced energy consumption during continuous operation.

Movable Protective Safety Cover
A movable protective barrier positioned between the furnace and loading assembly enhances operational safety during weight handling and sample loading. This feature reduces exposure to high-temperature zones and supports safer, controlled test execution throughout the workflow.

Software-Controlled Variable Load System

The QualiFi™ 6000A features an advanced software-driven load management system designed to deliver fully automated, highly repeatable melt flow testing with minimal operator involvement. This system is a core differentiator of the model within the QualiFi™ Series.

Software-Controlled Multi-Weight Selection with Variable Load Function
The instrument uses a software-managed multi-weight selection system with variable load capability, allowing fully programmable load changes during a single test cycle. This eliminates dependence on preset manual configurations and supports more flexible, condition-specific testing workflows.

Automatic Weight Handling System
Weights are lifted and lowered automatically through a motorized control system, removing the need for manual weight handling. This reduces operator exposure to high-temperature components and helps eliminate load sequencing errors, improving overall test consistency and repeatability.

Integrated Weight Safety Guard
A built-in weight safety guard is included as standard to prevent unintended weight drop events during automatic load transitions. This enhances operational safety and ensures stable load control throughout the testing process.

Dual Preloading Modes
The system supports two preloading configurations for flexible testing setup:

  • Calibration Weight Load: 0.325–21.6 kg range for standard calibration procedures
  • Additional Load: 10–50 kg adjustable range for extended test conditions

These adjustable settings enable precise reproduction of test conditions across different materials and standards, supporting consistent and traceable measurement results.

Pneumatic Automation System

The QualiFi™ 6000A integrates a fully pneumatic control system to ensure consistent specimen preparation, efficient workflow transitions, and improved operational safety across melt flow testing procedures.

Pneumatic Compaction with Adjustable Load Control
Pneumatic compaction operates with adjustable force settings (10–50 kg) and configurable compaction time, ensuring uniform specimen packing. This removes operator-dependent variability and supports consistent sample preparation conditions across repeated tests.

Pneumatic Residual Material Extrusion
An automated pneumatic extrusion function applies adjustable load (10–50 kg) to efficiently purge residual material from the barrel after testing. This enables rapid transition between samples while maintaining repeatable cleaning performance.

Pneumatic Barrel Cleaning System
The system includes pneumatic-assisted barrel cleaning to standardize inter-test preparation. This eliminates manual brushing, reduces contamination risk, and ensures consistent cleaning efficiency between consecutive tests.

Air Supply Requirement
The system operates with a compressed air requirement of >0.6 MPa, ensuring stable pneumatic performance for compaction, extrusion, and cleaning functions throughout the testing cycle.

Temperature Control

  • Full operating range of 50–450 °C, enabling testing from commodity plastics to high-temperature engineering polymers on a single melt flow index tester platform.
    Multi-stage independent temperature control with dynamic heat distribution ensures a temperature gradient within ≤±0.1 °C along the barrel above the die.
  • Temperature indication error is ≤0.2 °C, with temperature fluctuation maintained within ≤±0.2 °C, and a fine temperature resolution of 0.01 °C for precise control.
  • Temperature recovery after specimen loading is ≤2 minutes, helping reduce overall cycle time in high-throughput melt flow index testing workflows.
  • An intelligent dual PID control algorithm ensures fast heating response, stable temperature rise, and consistent thermal recovery throughout operation.

Measurement Performance

  • MFR measurement range: 0.1–100 g/10 min; MVR measurement range: 0.01–3,000 cm³/10 min — one of the widest measurement ranges available in the melt flow indexer category, enabling accurate testing across very low to very high flow thermoplastics.
  • Piston displacement indication error: ±0.02 mm; displacement resolution: 0.002 mm, ensuring highly precise piston movement tracking during measurement cycles.
  • Timer resolution: 0.0005 seconds — the finest timing resolution in the QualiFi™ melt flow indexer series, supporting highly accurate flow rate calculations.
  • Die plug device based on a lever principle, extending the measurable range up to 3,000 cm³/10 min while preventing barrel leakage during high-flow testing conditions.

Control Software & Data Management

  • Menu-guided 10.1-inch full HD color touchscreen interface with real-time temperature–time curve and MVR curve visualization, providing clear monitoring of testing conditions and flow behavior during operation.
  • Mass method, Volume Method A, and Volume Method B testing are fully supported, with automatic ISO/ASTM effective interval identification and automatic test start for standardized workflow execution.
  • 8 stored test plan groups enable fast setup across multiple materials and specifications, improving efficiency in multi-material quality control environments.
  • The volume method automatically calculates MFR values from the input specimen mass, allowing direct comparison with mass method results for consistent data validation.
  • 5,000-group USB flash storage capacity and integrated DMS data management software support data export, analysis, and structured report generation. Optional PC software enables two-way control between PC and touchscreen, with direct upload to external databases and information systems.
  • Multi-language interface support includes English, French, German, Italian, Russian, and additional languages for broader usability in global laboratories.
  • A user authority management system with role-based access control protects measurement data and helps prevent operational errors.
  • Optional CNAS-validated inter-laboratory proficiency testing records demonstrate performance consistency, with Z-scores maintained within ±0.11 across evaluations.

Accessories & Safety

  • Adjustable metal observation mirror with 15° free-angle adjustment, explosion-proof and shatter-resistant design, and switchable viewing angles for clear monitoring of sample extrusion during testing.
  • Cutting segment collection box prevents fragment contamination of cut-off samples, helping maintain test integrity and result accuracy.
  • Stacking accessory support provides organized placement and easy access to all standard accessories during operation, improving workflow efficiency.
  • Standard accessory set includes: barrel, piston rod, guide bush, weight tray and cover, Φ2.095 mm die, barrel cleaning rod, feeding rod, die cleaning rod, cutter, funnel, special tweezers, USB flash drive, wrenches, power cable, and PC software.

Theory and Method

Extrusion Plastometry — MFR and MVR Determination
The QualiFi™ 6000A operates based on the extrusion plastometry principle defined in ISO 1133 and ASTM D1238. A thermoplastic resin sample is introduced into a heated cylindrical barrel and brought to a controlled test temperature under defined preheating conditions. A specified dead-weight load is then applied through a piston, forcing the molten polymer through a precision-engineered die at the base of the barrel.

The melt flow indexer determines either the mass of extrudate collected over set time intervals (Mass Method, Method A: MFR expressed in g/10 min) or piston displacement over time intervals (Volume Method, Method B: MVR expressed in cm³/10 min), enabling evaluation of flow resistance under standardized conditions.

The melt flow index is inversely related to polymer viscosity under test conditions. Higher MFR or MVR values indicate lower melt viscosity and easier flow, while lower values reflect higher viscosity and greater flow resistance. This makes melt flow index a key parameter for quality control, batch consistency evaluation, molecular weight distribution screening, and process verification across thermoplastic materials.

Software-Controlled Variable Load System
A defining feature of the QualiFi™ 6000A within the QualiFi™ melt flow indexer range is its software-driven weight selection system with variable load functionality. Instead of manual weight selection or fixed configurations, test loads are fully programmed through software. The system automatically selects, lifts, and lowers required weights, including multi-stage load variation within a single test cycle, without manual intervention. This removes errors related to incorrect weight selection, handling contamination, and load sequencing inconsistencies in multi-step testing protocols.

Multi-Stage Independent Temperature Control with Dual PID Algorithm
Temperature control is managed by a high-performance heating and sensing system designed for continuous operation across 50–450 °C. Multi-stage independent control ensures dynamic heat distribution along the barrel, maintaining a temperature gradient of ≤±0.1 °C above the die.

Temperature indication error is ≤0.2 °C, with fluctuation maintained within ≤±0.2 °C. The dual PID control algorithm enables rapid heating response and stable recovery, achieving temperature stabilization within less than 2 minutes after sample loading, significantly improving overall test cycle efficiency.

High-Precision Displacement Measurement
Piston displacement used in MVR calculations is measured using a high-precision system with an indication error of ±0.02 mm and a resolution of 0.002 mm. The timer resolution of 0.0005 seconds enables highly accurate measurement of short interval cut-off sequences, supporting high-flow materials and extended measurement ranges up to 3,000 cm³/10 min.

Pneumatic Operation — Compaction, Residual Extrusion, and Barrel Cleaning
The system integrates pneumatic automation across three key stages of the workflow.
Pneumatic compaction applies adjustable force and time (10–50 kg) to ensure uniform specimen packing, eliminating variability associated with manual compaction.
Pneumatic residual extrusion uses adjustable load (10–50 kg) to rapidly purge remaining material from the barrel after testing, improving turnaround efficiency.
Pneumatic barrel cleaning enables fast, consistent cleaning without manual intervention, reducing contamination risk and improving repeatability.

Preloading and Preheating Modes
The QualiFi™ 6000A supports two preloading modes: calibration weight load (0.325–21.6 kg) and additional load (10–50 kg), both adjustable for accurate reproduction of test conditions across different materials. Two preheating modes (no-load and loaded) provide flexibility for various polymer types and testing protocols, supporting diverse laboratory requirements on a single platform.

Measurement and Control Software
The onboard software supports Mass Method (Method A), Volume Method A, and Volume Method B testing in full compliance with ISO 1133 and ASTM D1238 standards. It automatically identifies effective test intervals and initiates measurements at the correct piston position without operator input, ensuring standardized operation.

Eight stored test plan groups allow pre-configuration of complete test parameters for different materials, reducing setup time and improving efficiency in multi-material testing environments. Real-time temperature–time curves and MVR flow curves displayed on the 10.1-inch touchscreen enable continuous monitoring of thermal stability and test repeatability throughout operation.

Automatic Melt Flow Indexer (MFI) — QualiFi™ 6000A Technical Specifications

Parameter QualiFi™ 6000A
Measurement Methods MFR (Mass Method) / MVR (Volume Method A & B)
MFR Measurement Range 0.1–100 g/10 min
MVR Measurement Range 0.01–3,000 cm³/10 min
Display Full-color 10.1-inch HD touch screen
Cutting Method Automatic
Timer Resolution (s) 0.0005
Temperature Control Range (°C) 50–450 °C
Temperature Resolution (°C) 0.01 °C
Temperature Indication Error ≤0.2 °C
Temperature Fluctuation ≤±0.2 °C
Temperature Gradient above Die (0–75 mm) ≤±0.3 °C
Temperature Recovery Time after Loading ≤2 minutes
Loading Mode Electric (automatic weight lifting/lowering)
Weight Selection System Software-controlled; multi-weight set with variable load function
Preload Range — Calibration Weight Mode (kg) 0.325–21.6 kg
Preload Range — Additional Load Mode (kg) 10–50 kg
Compaction Load Range (kg) 10–50 kg — pneumatic
Residual Material Extrusion Load Range (kg) 10–50 kg — pneumatic
Piston Displacement Indication Error (mm) ±0.02 mm
Piston Displacement Display Resolution (mm) 0.002 mm
Voltage 220V AC (-15% to +10%), 50 Hz, 0.5 kVA (110V is also available)
Air Source Requirement >0.6 MPa
Dimensions W×D×H (mm) 600×500×1,450 mm
Weight (kg) 120 kg
Data Storage 5,000 test groups (USB flash drive)
Software DMS data management software; optional PC two-way control software
Interface Languages English, French, German, Italian, Russian, and others
Certifications CE (EN 61010-1, EN 61326-1); CNAS inter-laboratory proficiency testing — satisfactory

Standard Accessory Configuration

Item Quantity
Main unit (including 1 barrel) 1 set
Basic weight set (piston rod, guide bush, weight tray, weight cover) 1 set
Die Φ2.095 mm 1 piece
Barrel cleaning rod 1 piece
Feeding rod 1 piece
Die cleaning rod 1 piece
Automatic cutter 1 piece
Funnel 1 piece
Level 1 piece
Special tweezers 2 pieces
Fuse 2 pieces
Hexagon wrench (2 mm) 1 piece
Fixed wrench (8–10 mm) 1 piece
USB flash drive 1 piece
Power cable 1 piece
PC software 1 set

Optional Accessories

Item Description
Sample Forming Machine Compression pre-forming device for powder, flake, film fragment, or granule specimens prior to MFR/MVR testing — particularly useful for materials that cannot be loaded directly into the melt flow indexer barrel

El plazo de entrega varía según la disponibilidad de stock. Nuestros plazos de envío estándar suelen ser de una semana; sin embargo, para algunos artículos de alta demanda, el plazo de entrega puede extenderse a dos o tres semanas. Si necesita estos artículos con urgencia, contáctenos para consultar la disponibilidad exacta de stock y organizar un envío más rápido.

🚚

Información importante sobre la entrega

El plazo de entrega varía según la disponibilidad de stock. Nuestros plazos de envío estándar suelen ser de una semana ; sin embargo, para algunos artículos de alta demanda, el plazo de entrega puede extenderse a dos o tres semanas .

¿Lo necesitas urgentemente? Contáctanos aquí para consultar existencias y organizar un envío más rápido.

Pedidos:
El comprador reconoce que al realizar un pedido en Qualitest:

A. la realización del pedido significa el consentimiento del comprador de realizar dicho pedido en Qualitest y que el pedido será aceptado una vez procesado exitosamente por Qualitest USA LC.
B. el hecho de que el comprador escriba su nombre cuando Qualitest se lo solicite constituye una firma del contrato.
C. el comprador tiene plena autoridad para celebrar el contrato para dicha entidad, y dicha concesión de autoridad fue indicada por el comprador mediante la colocación del pedido a través de Qualitest.
D. Se aplicará una tarifa de manipulación mínima al total del envío para todos los pedidos.

Envíos dentro de EE. UU.:

Todos los pedidos se enviarán con portes pagados, por mensajería para paquetes pequeños o mediante transportistas para cajas más grandes. Se podría aplicar un cargo por manejo. La propiedad de la mercancía se transfiere al comprador al momento de la entrega al transportista. Las pérdidas o daños durante el transporte son responsabilidad del comprador. Qualitest USA le brindará asistencia con la información necesaria para procesar las reclamaciones.

Envíos fuera de EE. UU.:

Todos los pedidos se enviarán de la mejor manera posible: por mensajería para paquetes pequeños o mediante transportistas para cajas más grandes. Podría aplicarse una tarifa de manejo baja. La propiedad de la mercancía se transfiere al comprador al momento de la entrega al transportista. Las pérdidas o daños durante el transporte son responsabilidad del comprador. Qualitest USA le brindará asistencia con la información necesaria para procesar las reclamaciones. Las tarifas de exportación, aranceles, impuestos y el despacho de aduanas son responsabilidad del comprador.

El seguro de envío no está incluido, comuníquese con nuestros representantes de ventas si necesita seguro de envío.

Envío parcial: Qualitest USA se reserva el derecho de realizar envíos parciales a menos que el comprador indique lo contrario.

Condiciones de pago: Todos los pagos a Qualitest USA deben realizarse en dólares estadounidenses (USD)

A. Tarjeta de crédito: Qualitest USA acepta Visa, MasterCard, AMEX o Discover. La información requerida del comprador es el número de tarjeta de crédito, el código de seguridad de 3 dígitos, la fecha de vencimiento, el nombre del titular (tal como aparece en la tarjeta), la dirección de facturación y un número de teléfono válido para que podamos usarlo en caso de cualquier problema. Qualitest USA se reserva el derecho de retrasar el envío hasta que se verifique la validez de la tarjeta de crédito.
B. Transferencia bancaria: La transferencia debe realizarse a nombre de Qualitest y confirmarse por el importe total de la compra (mercancía, manipulación y envío) antes del envío. Para obtener información bancaria, contáctenos por teléfono al 1.877.884.TEST (8378) (fuera de EE. UU.: +1.905.944.9825) o por fax al +1.954.697.8211.
C. Apertura de cuenta: Disponible solo para clientes de EE. UU. y Canadá. Las cuentas abiertas tienen una vigencia de 30 días a partir de la fecha de envío. Qualitest USA se reserva el derecho de rechazar el envío de nuevos pedidos si alguna factura impaga tiene más de 30 días de antigüedad. Los compradores pueden solicitar la apertura de una cuenta proporcionando:

su información bancaria
3 referencias crediticias de otros proveedores
Por favor, espere 5 días hábiles para la confirmación del crédito y la creación de una cuenta abierta.

Política de devoluciones:

Qualitest USA puede aceptar la devolución de mercancía comprada dentro de América del Norte para reembolso o crédito bajo las siguientes condiciones:

  • Es posible que se aplique una tarifa de reposición adicional a la transacción si los artículos ya se enviaron al cliente.
  • Los productos deben devolverse a Qualitest USA dentro de los 5 días posteriores a la fecha de recepción de los productos comprados.
  • Todos los gastos de envío, aranceles, aduanas y demás gastos relacionados con la mercancía devuelta correrán a cargo del comprador. Se rechazarán los envíos a portes debidos.
  • La mercancía debe devolverse debidamente embalada, en condiciones nuevas y aptas para la venta, junto con el embalaje original y toda la documentación, accesorios y certificados.
  • El comprador ha confirmado la autorización de devolución directamente con Qualitest.
  • La mercancía es un artículo de catálogo regular. Los artículos de pedidos especiales no se pueden devolver.
  • Toda mercancía devuelta está sujeta a inspección por Qualitest. Qualitest se reserva el derecho de rechazar la devolución de cualquier mercancía usada, dañada o que no se encuentre en la lista de precios publicada. En caso de que Qualitest no acepte la mercancía devuelta, se hará todo lo razonablemente posible para notificar al Comprador y la mercancía se le devolverá tal como la recibió. La mercancía dañada que pueda restaurarse a su estado original y, por lo tanto, sea aceptada para su devolución, se evaluará individualmente. Se informará al comprador de los gastos adicionales por la reparación y restauración del artículo devuelto. Tras la aprobación, estos gastos se le cobrarán al comprador, además de la tarifa de reposición.


Cambio de Términos:

La aceptación de cualquier pedido por parte de Qualitest USA está sujeta a la aceptación por parte del comprador de todos los términos y condiciones aquí establecidos. La aceptación por parte del comprador de estos términos y condiciones se presumirá desde el momento en que realice un pedido a través de Qualitest. Se rechazan expresamente todos los demás términos y condiciones, y ninguna adición o modificación de los mismos será vinculante sin el consentimiento previo por escrito de Qualitest USA.

Acuerdo completo:

Los términos y condiciones del sitio web de Qualitest, incorporados aquí por referencia, incluidos formularios, reconocimientos, cotizaciones, facturas y términos y condiciones de venta, constituyen el acuerdo completo y exclusivo entre el comprador y Qualitest USA LC.

Información:

Qualitest USA se esfuerza al máximo para garantizar la exactitud de la información de los productos que se muestra en sus sitios web, pero no ofrece garantías, expresas ni implícitas, sobre la exactitud de los datos presentados en ellos. Qualitest USA se reserva el derecho de modificar la información de los productos, incluyendo la información de precios, en cualquier momento y sin previo aviso.

Marcas comerciales y derechos de autor:

Qualitest, de WorldofTest.com, contiene nombres de productos registrados. Los nombres de productos no pueden ser reproducidos ni utilizados de ninguna manera por terceros ajenos a Qualitest sin el consentimiento expreso por escrito de Qualitest International Inc. Todas las imágenes, descripciones y demás contenido de este sitio web están protegidos por derechos de autor de Qualitest USA y no pueden utilizarse sin su autorización expresa por escrito. El comprador reconoce que no tiene ningún derecho, título ni interés sobre las marcas comerciales o los derechos de autor de los productos, y se compromete a no registrar ni interferir con dichos derechos. Contáctenos si tiene alguna solicitud de permiso o pregunta sobre nuestras marcas comerciales.

Descargo de responsabilidad de garantía:

Qualitest USA no otorga ni autoriza ninguna garantía ni afirmación de hecho, expresa o implícita, salvo lo establecido expresamente en este documento. Qualitest USA declina toda responsabilidad por reclamaciones por defectos del producto. Qualitest USA no garantiza, expresa ni implícitamente, que ningún producto del sitio web sea apto para un propósito específico. Qualitest USA respeta la garantía del producto publicada y puesta a disposición por Qualitest USA. Las reclamaciones de garantía de productos no fabricados por Qualitest son responsabilidad del fabricante. Qualitest USA siempre hará todo lo posible de buena fe para resolver las reclamaciones de garantía.


Fuerza mayor:

Qualitest USA no será responsable por ninguna demora o deterioro del rendimiento que resulte total o parcialmente de casos fortuitos, interrupciones del servicio, interrupciones laborales, insurrecciones, decretos o controles gubernamentales, riesgos de guerra, clima severo, suministros o materias primas, incapacidad para adquirir o enviar productos, incapacidad para obtener permisos y/o licencias, o cualquier otra circunstancia o causa fuera del control de Qualitest USA en la conducción de su negocio.

Política de privacidad de Qualitest USA 

I. ¿Qué disposiciones legales rigen nuestras prácticas de tratamiento de datos? ¿Cómo y de dónde (fuentes internas/externas) se obtienen los datos personales? ¿Cuáles son los derechos del usuario (visitante del sitio web/cliente registrado)? 

1. General
Como principio general, no es necesario proporcionar datos personales al visitar nuestro sitio web. Los datos que nos proporciona se tratan con estricta confidencialidad y de acuerdo con las disposiciones de la Ley Federal de Protección de Datos. Con algunas excepciones (véase el punto 2 a continuación), nuestro servidor web solo registra datos no personales (anónimos) sobre el uso de nuestro sitio. En concreto, los archivos de registro de nuestro servidor web, por regla general, solo contienen la dirección IP del usuario, la última página visitada, el navegador utilizado, la fecha, la hora y el archivo solicitado. Sin embargo, estos datos anónimos no permiten extraer conclusiones sobre los usuarios individuales y solo sirven para elaborar estadísticas sobre el uso de nuestro sitio web con el fin de mejorarlo. Al mismo tiempo, es fundamental garantizar que los datos de uso no se vinculen con datos personales.

2. Datos personales

Los datos personales solo se utilizan si se solicita el boletín informativo (por correo electrónico), se solicitan productos o se proporciona información sobre productos. Nos comprometemos a utilizar los datos personales que nos confíe únicamente para los fines indicados. El historial de compras se conserva para atender futuras necesidades del cliente.

II. ¿Qué medidas de seguridad se utilizan para proteger los datos personales? ¿Qué opciones tiene el usuario para procesar sus datos personales? 

3. Medidas técnicas

Las bases de datos están óptimamente protegidas contra el acceso, la pérdida, el uso indebido y la falsificación por parte de terceros mediante el uso de medios técnicos adecuados. Para determinar la popularidad de cada área temática, se utilizan cookies en dichas secciones. Estos archivos de texto se almacenan en su disco duro y facilitan el uso de nuestro sitio web. Gracias a estas cookies, no es necesario registrarse cada vez que visita una sección que lo requiere, y podemos ofrecerle el contenido personalizado que solicita.

Usted decide si desea trabajar con cookies y, en caso afirmativo, de qué tipo (almacenadas permanentemente en el disco duro o solo mientras navega). Sin embargo, le advertimos que el acceso a los campos que requieren registro solo es posible con las cookies activadas.

III. ¿Qué datos se comunican a terceros y con qué finalidades? 

4. Comunicación de datos personales

Los datos personales que usted nos confía no se comunican, alquilan ni venden a terceros.

IV. ¿Qué departamento responde preguntas sobre el tratamiento de datos personales? 

5. Contacto

Debido a los rápidos avances técnicos en internet, nos esforzamos al máximo para mejorar constantemente nuestro sitio web y las precauciones técnicas, incluyendo las relacionadas con la protección de datos. Le mantendremos informado sobre dichas medidas. Cualquier cambio se publicará aquí. Puede obtener más información en cualquier momento contactando con Qualitest USA.

Exención de responsabilidad. Qualitest USA no será responsable de las pérdidas directas, indirectas o consecuentes que resulten de o estén relacionadas con el acceso, uso o consultas al sitio web de Qualitest o sus enlaces con otros sitios web, incluso si Qualitest USA ha sido informado previamente de la posibilidad de dichas pérdidas. No se garantiza la exactitud de la información difundida a través del sitio web de Qualitest USA. Además, Qualitest USA no garantiza la fiabilidad ni la integridad de la información contenida en su sitio web. La información disponible en el sitio web de Qualitest y WorldofTest.com puede modificarse en cualquier momento sin previo aviso. En particular, Qualitest USA no será responsable de las pérdidas causadas por errores de transmisión, fallos técnicos e interrupciones, averías o una interferencia ilícita en el sistema de procesamiento de datos del usuario o en los sistemas y redes de transmisión de acceso general. Qualitest USA tampoco será responsable de las pérdidas resultantes de averías, interrupciones o sobrecargas que se produzcan en cualquier sistema de procesamiento de datos. Si se activan ciertos enlaces en los sitios web de Qualitest y WorldofTest.com, el usuario podría, en determinadas circunstancias, abandonar el sitio web de Qualitest. Qualitest USA no asume ninguna responsabilidad por el contenido, los productos o servicios ofrecidos, ni por ninguna otra información u ofertas contenidas en estos sitios web enlazados.

Productos relacionados