Semi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA

QualiFi™ 6000SA is a semi-automatic, safety-enhanced melt flow indexer developed for B2B plastics testing laboratories that require higher throughput, reduced operator involvement, and improved safety compared to a standard automatic weight-loading instrument. It measures MFR across 0.1–100 g/10 min and MVR up to 3000 cm³/10 min at temperatures from 50 to 450 °C. This melt flow index tester integrates pneumatic material compaction, pneumatic residual extrusion, pneumatic barrel cleaning, and a weight fall-prevention guard within the QualiFi™ Series platform—delivering a safer, faster, and more repeatable testing workflow than the QualiFi™ 5000. CE certified and CNAS proficiency-verified, the QualiFi™ 6000SA is a reliable upgrade melt flow index tester for high-frequency QC and production monitoring environments across North America.

The QualiFi™ 6000SA is a pneumatic-assisted semi-automatic melt flow indexer designed for plastics testing environments where test throughput, operator safety, and measurement repeatability are higher priorities than compact benchtop design. Built on the QualiFi™ Series platform, it retains the core measurement precision, dual PID temperature control, and software capabilities of the QualiFi™ 5000 while adding pneumatic-assisted functions and a weight fall-prevention guard that reduce manual intervention, minimize human error, and improve operator safety during frequent testing cycles.

The weight is manually selected by the operator but automatically lifted and lowered without physical handling once selected, similar to the QualiFi™ 5000 lifting mechanism. A weight fall-prevention guard is added in the 6000SA, physically securing the weight stack and reducing the risk of uncontrolled weight movement during operation. Material compaction is performed pneumatically with adjustable force and time (10–50 kg), removing variability from manual compaction and improving repeatability for high-viscosity materials.

Pneumatic residual material extrusion uses adjustable pneumatic load (10–50 kg) to remove remaining polymer from the barrel after each test, reducing between-test cleaning time and effort. Pneumatic barrel cleaning completes the post-test cycle using compressed air to clear internal residue, eliminating the need for manual rod cleaning typically required on standard melt flow index testers. These three pneumatic functions reduce total turnaround time between tests, making the QualiFi™ 6000SA suitable for high-frequency QC environments where multiple tests are performed per shift.

All core QualiFi™ Series platform features are retained, including the 10.1-inch HD touch screen, 50–450 °C dual PID temperature control, ±0.2 °C temperature accuracy, 0.002 mm piston displacement resolution, 8 customizable test plans, 5,000-group USB data storage with DMS software, optional PC two-way control, and multi-language interface support. The floor-standing design (580×480×1450 mm) accommodates the pneumatic assembly and weight guard system and requires a compressed air supply above 0.6 MPa.

Semi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA Applications

The QualiFi™ 6000SA melt flow indexer is designed for B2B plastics testing environments where test frequency, operational safety, and throughput are key requirements, and where variations from manual compaction in a standard melt flow index tester can impact result consistency.

High-Frequency Production QC:
Incoming and outgoing inspection of polyolefin, engineering plastic, and specialty resin batches at high testing volumes. Pneumatic cleaning and residual extrusion reduce between-test downtime and improve workflow efficiency.

High-Viscosity Polymer Testing:
MFR/MVR evaluation of materials such as nylon, polycarbonate, fluoroplastics, and other engineering resins requiring stable and repeatable compaction force. Pneumatic compaction eliminates operator-dependent variation associated with manual loading.

Petrochemical & Compounding Lines:
Process control and product validation of polymer melts and compound formulations that require consistent test conditions and fast changeover between samples without dismantling the barrel assembly.

Plastics Manufacturing Operations:
Batch qualification, supplier verification, and extrusion or injection molding process monitoring based on defined MFR limits in accordance with ISO 1133 and ASTM D1238 standards.

Regulated & Accredited Laboratories:
Third-party testing, certification, and inspection workflows requiring traceable data export, user access control, and CNAS-verified measurement consistency across repeated test cycles.

Academic & Applied Research:
Polymer behavior analysis, blend formulation studies, and comparative melt flow testing across material grades with detailed data logging and reproducible test conditions.

Standards

The QualiFi™ 6000SA melt flow indexer is designed and verified in accordance with internationally recognized standards for thermoplastic melt flow rate testing, laboratory measurement accuracy, and equipment safety.

  • ISO 1133-1:2011 — Plastics: Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics — Part 1: Standard procedure
  • ISO 1133-2:2011 — Plastics: Determination of MFR and MVR of thermoplastics — Part 2: Method for materials sensitive to time-temperature history and/or moisture
  • ASTM D1238 — Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer (Procedures A and B)
  • IEC 61010-1 / EN 61010-1:2010+A1:2019 — Safety requirements for electrical equipment used in measurement, control, and laboratory applications (CE certified)
  • EN 61326-1:2013 — Electrical equipment for measurement, control, and laboratory use: EMC requirements (CE certified)
  • ISO 9001:2015 — Quality management system standard applied to laboratory instrument manufacturing processes

Certifications and Proficiency Verification

The QualiFi™ 6000SA is built on the validated QualiFi™ Series platform and maintains the same core compliance framework across the product family, including CE certification and repeated CNAS proficiency testing validation.

CE Certification:
Complies with EN 61010-1:2010+A1:2019 (Low Voltage Directive) and EN 61326-1:2013 (EMC requirements), confirmed through ECM Certificate of Compliance.

CNAS Proficiency Testing:
Verified through consecutive CNAS inter-laboratory proficiency comparisons, with all results within acceptable limits. Reported Z-scores remain in the range of −0.07 to +0.11 across all evaluation rounds.

Technical Patents:
The QualiFi™ Series includes multiple registered technical patents covering core measurement systems, thermal control architecture, and structural design innovations.

Semi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA Key Features

Pneumatic Systems and Safety Step-up from QualiFi™ 5000

The QualiFi™ 6000SA integrates enhanced pneumatic systems over the QualiFi™ 5000, improving consistency, efficiency, and operator safety in melt flow index testing workflows.

Pneumatic Material Compaction (10–50 kg adjustable):
Provides controlled compaction force and timing, eliminating operator-dependent variation during sample preparation and improving run-to-run MFR/MVR repeatability.

Pneumatic Residual Material Extrusion (10–50 kg adjustable):
Uses controlled pneumatic load to remove remaining polymer from the barrel after testing, reducing reliance on manual rod operation and accelerating post-test processing.

Pneumatic Barrel Cleaning:
Applies compressed air to clear residual material from the barrel interior, significantly reducing between-test preparation time and improving efficiency in high-frequency testing environments.

Weight Fall-Prevention Guard:
A mechanical safety system that physically secures the weight stack, preventing uncontrolled descent during setup, weight changes, or loading operations. This adds an extra layer of operational safety compared to the QualiFi™ 5000.

Preloading System (Dual Mode):
Supports two controlled loading ranges to ensure accurate and repeatable test conditions across different materials:

  • Calibration weight load: 0.325–21.6 kg
  • Additional load: 10–50 kg

Both modes allow adjustable positioning to support precise reproduction of test parameters for varied material types.

Preheating Function:
Supports both no-load and loaded preheating operation modes, enabling flexible preparation protocols based on material characteristics and specific testing requirements.

Core Measurement Platform

Core components including the oven, die, and piston are manufactured from low-thermal-expansion, corrosion-resistant alloy materials that comply with ISO 1133 dimensional stability and hardness requirements, ensuring long-term measurement accuracy under high-temperature conditions.

Temperature Control System:
Operating range: 50–450 °C
Temperature resolution: 0.01 °C
Maximum indication error: ≤0.2 °C
Fluctuation: ≤±0.2 °C
Temperature gradient: ≤±0.1 °C

The system uses dual PID temperature control for rapid, overshoot-free heating and stable regulation. After material loading, temperature recovery time is typically ≤2 minutes, supporting continuous high-frequency testing.

Measurement Precision System:
Piston displacement resolution: 0.002 mm
Maximum indication error: ±0.02 mm
Timer resolution: 0.001 s

These parameters support high-accuracy MFR/MVR determination with stable time and displacement tracking during extrusion testing.

Extended Flow Measurement Capability:
Maximum measurable flow rate reaches up to 3000 cm³/10 min, extended through a lever-operated die plug device for broader material applicability.

Weight Handling and Automation:
The system enables automatic lifting and lowering of weights without manual handling during operation. Weight selection is performed manually prior to test initiation, supporting controlled and repeatable loading conditions.

User Interface and Observation System:
A 10.1-inch HD full-color touchscreen is integrated at the front of the oven for direct control and monitoring. A variable-angle metal observation mirror with 15° adjustable viewing and a shatter-resistant surface allows safe visual inspection during operation.

Safety Structure:
A movable protective cover shields the area between the furnace body and loading mechanism during high-temperature operation, improving operator safety and reducing exposure to heated components.

Software and Data Management

The system supports Mass Method (A), Volume Method A, and Volume Method B testing, with automatic identification of ISO/ASTM test intervals and automated test initiation to streamline workflow execution.

Test Configuration:
Provides 8 customizable test plans for direct selection before testing, reducing repetitive parameter setup in routine laboratory operations and improving workflow efficiency.

Real-Time Monitoring:
Displays temperature–time and MVR–number curves in real time on the screen, enabling immediate evaluation of thermal stability and result consistency during testing.

Data Storage and Reporting:
USB flash drive storage supports up to 5,000 test result groups. Integrated DMS data management software enables data export and structured report generation for laboratory documentation and traceability.

PC Integration and Connectivity:
Optional PC software allows two-way system control and remote database upload, supporting centralized data management in multi-instrument environments.

Multi-Language Interface:
Supports English, French, German, Italian, Russian, and Chinese for flexible international laboratory use.

User Access Control:
Includes user authority management with configurable role-based permissions to safeguard measurement data integrity and prevent unauthorized parameter modifications in shared laboratory settings.

Theory and Method

Melt Flow Rate Measurement Principle

The QualiFi™ 6000SA operates based on the extrusion plastometer principle defined in ISO 1133 and ASTM D1238. A thermoplastic resin sample is introduced into a heated barrel and stabilized at the specified test temperature. A piston applies a defined load, forcing the molten polymer through a standard die (Φ2.095 mm) located at the base of the barrel.

MFR (mass method, Procedure A) is determined by measuring the mass of extrudate collected at timed intervals. MVR (volume methods A and B) is calculated from piston displacement over a defined time period. The QualiFi™ 6000SA automates weight lifting, timing control, cutting, and result calculation, while also integrating pneumatic compaction, pneumatic residual extrusion, and pneumatic barrel cleaning. These additions reduce the number of manual operations per test cycle compared to the QualiFi™ 5000.

Pneumatic Compaction System

Material compaction, the process of pressing the loaded polymer charge into the barrel prior to testing, is performed pneumatically on the QualiFi™ 6000SA with adjustable load and time (10–50 kg). In conventional melt flow index testers, this step is carried out manually using a feeding rod, which can introduce variation in applied force and compaction duration.

The pneumatic system provides a consistent and repeatable compaction force across all test cycles, independent of operator technique. This improves run-to-run repeatability of MFR/MVR results, particularly for high-viscosity polymers and powder materials where pre-test density uniformity is critical.

Pneumatic Residual Extrusion and Barrel Cleaning

After each test cycle, remaining polymer in the barrel must be removed before the next sample is introduced. The QualiFi™ 6000SA performs this in two pneumatic stages:

First, pneumatic residual extrusion applies an adjustable load (10–50 kg) to expel remaining polymer from the barrel and die, replacing manual push-rod operation used in conventional systems.

Second, pneumatic barrel cleaning uses compressed air to remove residual material from the internal barrel surface.

Together, these steps significantly reduce post-test turnaround time, minimize operator effort, and reduce exposure to high-temperature components, strengthening the safety-oriented design of the 6000SA.

Weight Fall-Prevention Guard

In floor-standing melt flow indexers, the weight stack is positioned at an elevated height, creating a potential risk of uncontrolled descent during setup, weight adjustment, or mechanical irregularities.

The QualiFi™ 6000SA incorporates a dedicated weight fall-prevention guard that physically restricts the weight stack movement and prevents uncontrolled descent events. This hardware safety mechanism is not included in the QualiFi™ 5000 and is specifically designed for the taller floor-standing structure of the 6000SA.

Dual PID Temperature Control and High-Precision Displacement

The QualiFi™ 6000SA retains the same core temperature control and measurement architecture as the QualiFi™ 5000 platform. A high-temperature heating system and sensor assembly rated for continuous operation from 50 to 450 °C is controlled by a dual PID temperature regulation system.

This ensures rapid, overshoot-free heating, stable multi-zone thermal distribution with a temperature gradient of less than ±0.1 °C, and recovery to stable conditions within 2 minutes after sample loading.

Piston displacement is measured with a resolution of 0.002 mm and a maximum indication error of ±0.02 mm. Timer resolution is 0.001 s, supporting precise MVR calculation across a measurement range of 0.01 to 3000 cm³/10 min.

Semi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA Technical Specifications

Parameter QualiFi™ 6000SA
Measurement Method MFR (mass method) / MVR (volume method A & B)
MFR Measurement Range 0.1–100 g/10min
MVR Measurement Range 0.01–3000 cm³/10min
Display Mode Full-color touch screen (10.1-inch HD)
Cutting Method Automatic cutting
Timer Resolution 0.001 s
Temperature Control Range 50–450 °C
Temperature Resolution 0.01 °C
Temperature Indication Error ≤ 0.2 °C
Temperature Fluctuation ≤ ±0.2 °C
Temperature Gradient (0–75 mm above die) ≤ ±0.3 °C
Temperature Recovery Time (after loading) ≤ 2 min
Loading Mode Electric loading — weight preset manually, auto lifted/lowered
Weight Selection Mode Manual pre-selection
Preloading Range Calibration weight: 0.325–21.6 kg; Additional load: 10–50 kg
Pneumatic Compaction Load 10–50 kg (adjustable), pneumatic operation
Pneumatic Residual Extrusion Load 10–50 kg (adjustable), pneumatic operation
Pneumatic Barrel Cleaning Yes — compressed air assisted
Weight Fall-Prevention Guard Yes — hardware fitted
Piston Displacement Indication Error ± 0.02 mm
Piston Displacement Resolution 0.002 mm
Standard Die Diameter Φ2.095 mm
Data Storage Capacity 5,000 groups (USB flash drive)
Test Plans 8 configurable and saveable test plans
Air Source Requirement > 0.6 MPa (required for pneumatic functions)
Voltage 220V (-15% / +10%) VAC, 50Hz, 0.5 kVA (110V is also available)
Dimensions L×W×H 580 × 480 × 1450 mm
Main Unit Weight 100 kg
Certifications CE (EN 61010-1:2010+A1:2019; EN 61326-1:2013); CNAS proficiency verified
Software Languages English, French, German, Italian, Russian, Chinese

Standard Configuration

Each QualiFi™ 6000SA ships with all accessories required for immediate MFR and MVR testing per ISO 1133 and ASTM D1238, plus PC software. Note that a compressed air supply of more than 0.6 MPa is required for the pneumatic functions.

Item Quantity
Main unit (including 1 barrel) 1 set
Basic weight set (piston rod, guide bush, weight tray, weight cover) 1 set
Standard die Φ2.095 mm 1 piece
Level 1 piece
Barrel cleaning rod 1 piece
Feeding rod 1 piece
Die cleaning rod 1 piece
Cutter 1 piece
Funnel 1 piece
Fuse 2 pieces
Special tweezers 2 pieces
Hexagon wrench (2 mm) 1 piece
USB flash drive 1 piece
Fixed wrench (8–10) 1 piece
Power cable 1 piece
PC software (DMS data management) 1 set

Optional Accessories

Item Description
Sample Forming Machine Compression pre-forming device for powder, flake, film fragment, or granule specimens prior to MFR/MVR testing — particularly useful for materials that cannot be loaded directly into the melt flow indexer barrel

O prazo de entrega varia conforme a disponibilidade em estoque. Nossos prazos padrão de despacho e envio são geralmente de até 1 semana, porém, para alguns itens de alta demanda, a entrega pode ser estendida para 2 a 3 semanas. Caso precise desses itens com urgência, entre em contato conosco para verificar a disponibilidade em estoque e providenciar métodos de envio mais rápidos.

🚚

Informações importantes sobre a entrega

O prazo de entrega varia de acordo com a disponibilidade em estoque. Nossos prazos padrão de despacho e envio são geralmente de dentro de 1 semana, no entanto, para alguns itens de alta demanda, a entrega pode ser estendida para 2 a 3 semanas.

Precisa com urgência? Entre em contato conosco aqui para verificar a disponibilidade em estoque e organizar um envio mais rápido.

Pedidos:
O comprador reconhece que, ao fazer um pedido no Qualitest:

C. O comprador tem plena autoridade para celebrar o contrato em nome da entidade, e essa concessão de autoridade foi indicada pelo comprador ao realizar o pedido por meio da Qualitest.
D. Uma taxa mínima de manuseio será aplicada ao valor total do frete para todos os pedidos.

Envio dentro dos EUA:

Todos os pedidos serão enviados da melhor maneira possível, com frete pré-pago, via transportadora para pacotes menores ou via transportadora para caixas maiores. Uma taxa de manuseio pode ser aplicada aos pedidos. A propriedade da mercadoria é transferida para o comprador no momento da entrega à transportadora. Perdas ou danos durante o transporte são de responsabilidade do comprador. A Qualitest USA fornecerá assistência com as informações necessárias para o processamento de reclamações.

Envio para fora dos EUA:

Todos os pedidos serão enviados da melhor maneira possível, via transportadora para pacotes menores ou via agentes de carga para caixas maiores. Uma pequena taxa de manuseio pode ser aplicada. A propriedade da mercadoria é transferida para o comprador no momento da entrega à transportadora. Perdas ou danos durante o transporte são de responsabilidade do comprador. A Qualitest USA fornecerá assistência com as informações necessárias para o processamento de reclamações. Taxas de exportação, impostos, taxas alfandegárias e desembaraço aduaneiro são de responsabilidade do comprador.

O seguro de envio não está incluído. Entre em contato com nossos representantes de vendas caso precise de seguro de envio.

Envio parcial: A Qualitest USA reserva-se o direito de fazer envios parciais, a menos que o comprador instrua o contrário.

Condições de pagamento: Todos os pagamentos à Qualitest USA devem ser feitos em dólares americanos (USD).

B. Transferência Bancária - A transferência deve ser feita para a Qualitest e confirmada no valor total da compra (mercadoria, manuseio e frete) antes do envio. Entre em contato conosco pelo telefone 1.877.884.TEST (8378) (fora dos EUA +1.905.944.9825) ou pelo fax +1.954.697.8211 para obter informações bancárias.
C. Conta Aberta - Disponível apenas para clientes dos EUA e Canadá. As condições para contas abertas são de 30 dias a partir da data de envio. A Qualitest USA reserva-se o direito de recusar o envio de novos pedidos se houver faturas em aberto com mais de 30 dias de atraso. Os compradores podem solicitar uma conta aberta fornecendo:

suas informações bancárias
3 referências de crédito de outros fornecedores
Por favor, aguarde 5 dias úteis para a confirmação do crédito e criação de uma conta aberta.

Política de Devolução:

A Qualitest USA poderá aceitar a devolução de mercadorias adquiridas na América do Norte para reembolso ou crédito, sob as seguintes condições -

  • Poderá ser cobrada uma taxa adicional de reabastecimento na transação se os itens já tiverem sido enviados ao cliente.
  • Todos os custos de frete, taxas alfandegárias e outras despesas de envio relacionadas à mercadoria devolvida são de responsabilidade do comprador. Envios com frete a cobrar serão recusados.
  • A mercadoria deve ser devolvida devidamente embalada, em estado de nova e própria para venda, juntamente com a embalagem original e toda a documentação, acessórios e certificados.
  • O comprador confirmou a autorização de devolução diretamente com a Qualitest.
  • A mercadoria é um item de catálogo regular. Itens de encomenda especial não podem ser devolvidos.
  • Todas as mercadorias devolvidas estão sujeitas à inspeção da Qualitest. A Qualitest reserva-se o direito de recusar a devolução de qualquer mercadoria que esteja usada, danificada ou que não faça parte da lista de preços publicada atualmente. Caso a Qualitest não aceite a mercadoria devolvida, serão feitos esforços razoáveis ​​para notificar o Comprador e a mercadoria será devolvida ao Comprador da mesma forma que foi recebida pela Qualitest. Mercadorias danificadas que possam ser restauradas à sua condição original e, portanto, aceitas para devolução, serão avaliadas individualmente. O comprador será informado sobre as despesas adicionais para o reparo e restauração do item devolvido. Após a aprovação, essas despesas serão cobradas do comprador, além da taxa de reabastecimento.


Alteração dos Termos:

A aceitação de qualquer pedido pela Qualitest USA está sujeita à aprovação do comprador. Ao efetuar um pedido à Qualitest, o comprador concorda com todos os termos e condições aqui estabelecidos. A concordância do comprador com estes termos e condições será presumida a partir do momento em que o comprador fizer um pedido à Qualitest. Quaisquer outros termos e condições são expressamente rejeitados, e nenhuma adição ou modificação dos termos e condições será vinculativa sem o prévio acordo por escrito da Qualitest USA.

Acordo Completo:

Os termos e condições do site da Qualitest, incorporados aqui por referência, incluindo formulários, confirmações, orçamentos, faturas e termos e condições de venda, constituem o acordo integral e exclusivo entre o comprador e Qualitest USA LC.

Informações:

A Qualitest USA se esforça ao máximo para garantir a precisão das informações sobre os produtos exibidas em seus sites, mas não oferece garantias, expressas ou implícitas, quanto à precisão dos dados apresentados nos sites. A Qualitest USA reserva-se o direito de alterar as informações sobre os produtos, incluindo informações sobre preços, a qualquer momento, sem aviso prévio.

Marcas registradas e direitos autorais:

O site WorldofTest.com Qualitest contém nomes de produtos com marcas registradas. Os nomes dos produtos não devem ser reproduzidos ou usados ​​de qualquer forma por terceiros, exceto pela Qualitest, sem o consentimento expresso por escrito da Qualitest International Inc. Todas as imagens, descrições e outros conteúdos deste site são protegidos por direitos autorais da Qualitest USA e não podem ser usados ​​sem a permissão expressa por escrito da Qualitest USA. O comprador reconhece que não possui nenhum direito, título ou interesse nas marcas registradas ou direitos autorais dos produtos e se compromete a não tomar nenhuma medida para registrar ou interferir de qualquer outra forma com tais direitos. Entre em contato conosco para quaisquer solicitações de permissão ou dúvidas sobre nossas marcas registradas.

Aviso de Isenção de Garantia:

Nenhuma garantia ou afirmação de fato, expressa ou implícita, além daquelas expressamente estabelecidas neste documento, é feita ou autorizada pela Qualitest USA. A Qualitest USA se isenta de toda e qualquer responsabilidade por reclamações de defeitos de produtos. A Qualitest USA não expressa ou implica uma garantia de que qualquer produto em seu(s) site(s) seja adequado para uma finalidade específica. A Qualitest USA honra a garantia do produto conforme publicada e disponibilizada pela Qualitest USA. Reclamações de garantia para produtos não fabricados pela Qualitest são de responsabilidade do fabricante. A Qualitest USA sempre fará o possível para resolver as reclamações de garantia.


Força Maior:

A Qualitest USA não será responsável por qualquer atraso ou prejuízo no desempenho resultante, total ou parcialmente, de casos fortuitos, interrupções de serviço, greves, insurreições, decretos ou controles governamentais, riscos de guerra, condições climáticas severas, falta de suprimentos ou matérias-primas, impossibilidade de adquirir ou enviar produtos, impossibilidade de obter permissões e/ou licenças, ou quaisquer outras circunstâncias ou causas fora do controle da Qualitest USA na condução de seus negócios. 

Política de Privacidade da Qualitest USA 

I. Quais disposições legais regem nossas práticas de processamento de dados? Como e de onde (fontes internas/externas) os dados pessoais são adquiridos? Quais são os direitos do usuário (visitante do site/cliente cadastrado)? 

1. Geral
Como princípio geral, não é necessário fornecer dados pessoais ao visitar nosso site. Os dados que você nos disponibiliza são tratados com estrita confidencialidade e em conformidade com as disposições da Lei Federal de Proteção de Dados. Com algumas exceções (ver ponto 2 abaixo), nosso servidor web registra apenas dados não pessoais (anônimos) referentes ao uso do nosso site. Especificamente, os arquivos de log do nosso servidor web, em regra geral, contêm apenas o endereço IP do usuário, a última página visitada, o navegador utilizado, a data, a hora e o arquivo solicitado. Esses dados anônimos, contudo, não permitem tirar conclusões sobre os usuários individualmente e servem apenas para elaborar estatísticas sobre o uso do nosso site com o objetivo de aprimorá-lo. Ao mesmo tempo, damos grande importância a garantir que os dados de uso não sejam vinculados a dados pessoais. 

2. Dados pessoais

Os dados pessoais são utilizados apenas se a newsletter for solicitada (por e-mail), se um ou mais produtos forem encomendados ou para fornecer informações sobre os produtos. Comprometemo-nos a utilizar os dados pessoais que nos forem confiados apenas para os fins indicados. O histórico de compras é conservado para auxiliar no atendimento de futuras necessidades do cliente. 

II. Quais medidas de segurança são utilizadas para proteger os dados pessoais? Quais são as opções do usuário para o processamento de dados pessoais? 

3. Medidas técnicas

As bases de dados são protegidas de forma otimizada contra o acesso, perda, uso indevido e falsificação por terceiros, através da utilização de meios técnicos adequados. Para determinar a popularidade de determinadas áreas temáticas, são utilizados cookies nessas seções. Esses arquivos de texto são armazenados no seu disco rígido e facilitam a sua utilização do nosso site. Graças a esses cookies, não é necessário um registo específico cada vez que visita uma seção que exige registo, e podemos fornecer-lhe o conteúdo personalizado que solicita. Você decide se deseja trabalhar com cookies e, em caso afirmativo, qual tipo (armazenados permanentemente no disco rígido ou apenas durante a atividade do navegador). No entanto, alertamos que o acesso a campos que exigem cadastro só é possível com os cookies ativados. 

III. Quais dados são comunicados a terceiros e para quais fins? 

4. Comunicação de dados pessoais

Os dados pessoais que você nos confia não são comunicados, alugados ou vendidos a terceiros. 

IV. Qual departamento responde a perguntas sobre o processamento de dados pessoais? 

5. Contato

Em virtude dos rápidos avanços tecnológicos relacionados à Internet, envidamos todos os esforços para aprimorar constantemente nosso site e as precauções técnicas, incluindo aquelas relacionadas à proteção de dados. Manteremos você devidamente informado sobre tais medidas. Quaisquer alterações serão publicadas aqui. Mais informações estão disponíveis a qualquer momento entrando em contato com a Qualitest USA.

Isenção de responsabilidade A Qualitest USA não será responsável por perdas diretas, indiretas ou consequenciais resultantes ou relacionadas ao acesso, uso ou consultas ao site da Qualitest ou seus links com outros sites, mesmo que a Qualitest USA tenha sido previamente informada da possibilidade de tais perdas. Nenhuma garantia é fornecida quanto à precisão das informações divulgadas por meio do site da Qualitest USA. Além disso, a Qualitest USA não garante a confiabilidade nem a integridade das informações contidas em seu site. As informações disponibilizadas nos sites da Qualitest e WorldofTest.com podem ser alteradas a qualquer momento sem aviso prévio. Em particular, a Qualitest USA não será responsável por perdas causadas por erros de transmissão, falhas técnicas e interrupções, avarias ou interferência ilícita no sistema de processamento de dados do usuário ou nos sistemas e redes de transmissão geralmente acessíveis. A Qualitest USA também não será responsável por perdas resultantes de avarias, interrupções ou sobrecargas que ocorram em quaisquer sistemas de processamento de dados. Se determinados links forem ativados no site da Qualitest e do WorldofTest.com, o usuário poderá, em certas circunstâncias, sair do site da Qualitest. A Qualitest USA não assume qualquer responsabilidade pelo conteúdo, produtos ou serviços oferecidos ou outras informações ou ofertas contidas nesses sites vinculados.

Produtos Relacionados