The QualiCSA™ 3 is a high-performance carbon and sulfur analyzer designed for rapid elemental determination in solid materials. Engineered for metallurgy and industrial testing laboratories, it delivers ultra-precise measurements down to 0.01 ppm within 40 to 60 seconds without compromising on stability or dynamic range.

  • 0.01 Ppm Detection Sensitivity
  • Fast 40 To 60 Second Cycles
  • Up To 4 Detection Channels
  • Max 1550°C Dual Combustion

Obtenha preços personalizados para os seus requisitos específicos

Carbon & Sulfur Analyzer – QualiCSA™ 3

Available Carbon & Sulfur Analyzer Models

  • High-Frequency Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3

  • Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3G

Carbon & Sulfur Analyzer – QualiCSA™ 3 Applications

High-Frequency Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3

The QualiCSA™ 3 Carbon & Sulfur Analyzer is designed for rapid carbon and sulfur analysis using high-frequency induction heating, infrared detection, advanced combustion technology, and full-range detection capabilities. The system provides simultaneous measurement of carbon and sulfur concentrations in a broad range of solid materials.

The QualiCSA™ 3 is suitable for laboratories and testing applications across steel, powder metallurgy, non-ferrous metals, magnetic materials, new energy materials, third-party testing, research institutes, and other industrial sectors. It can analyze carbon and sulfur in steel and alloys, non-ferrous metals, powder metallurgy materials, rare earth materials, NdFeB, ores, and other solid samples.

A stable, high-efficiency high-frequency power system supports complete sample combustion for reliable analysis. The analyzer also incorporates effective shielding against high-frequency interference to support consistent analytical performance and measurement stability.

Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3G

The QualiCSA™ 3G Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer combines high-frequency induction heating and tubular resistance furnace technology to accommodate a wider range of sample types and analytical requirements.

The instrument features two sample pretreatment and combustion systems: a high-frequency induction furnace and a tubular resistance furnace. Both furnace systems use the same infrared detection system to measure the carbon- and sulfur-containing gases generated during combustion. Switching between the two furnace systems is straightforward, allowing the analyzer to support different testing methods and sample characteristics.

The QualiCSA™ 3G is suitable for carbon and sulfur analysis across a diverse range of solid materials, including steel, cast iron, alloys, metal ores, ceramics, cement, lime, rubber, coal, coke, refractory materials, carbide, graphite, oil, catalysts, soil, and other materials.

With dual furnace capabilities and a shared infrared detection platform, the QualiCSA™ 3G Carbon & Sulfur Analyzer provides a flexible solution for laboratories requiring carbon and sulfur analysis across varied sample types and testing applications.

Features of the High-Frequency Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3

Modular Instrument Configuration

  • Infrared Detection Unit: Supports up to four independent infrared detection channels, with a high-sulfur channel available according to application requirements. The system uses pyroelectric solid-state infrared detectors.

  • Motor: A synchronous motor supports continuous analyzer operation with dependable performance.

  • Infrared Light Source: The infrared source provides stable optical performance and resistance to oxidation.

  • Temperature Control: The IR cell temperature is continuously maintained at a stable level to support measurement accuracy.

  • Copper Oxide Catalysis Furnace (Optional): Converts trace CO to CO₂ for complete carbon detection. It also converts SO₂ to SO₃, which is absorbed by cotton to help reduce emissions.

Instrument Self-Check and Gas Management

  • Stable Flow Control: High-precision differential-pressure electronic flow control technology provides consistent analysis gas flow.

  • Gas-Saving Mode: Oxygen flow automatically stops when an analysis cycle is complete, helping reduce oxygen consumption.

User-Friendly Analysis Software

The QualiCSA™ 3 includes English-language operating software compatible with Windows 10 and Windows 11. The software is designed for straightforward operation and supports free software updates.

Flexible Sample Weight Input

The system provides multiple options for entering or obtaining specimen weight values:

  • Automatic weight reading

  • Manual weight reading

  • Manual weight entry

  • Automatic crucible tare

Automatic Range Switching

The analyzer automatically switches between high and low carbon and sulfur measurement ranges according to the concentration detected.

Automatic Flux Blank Deduction

The software automatically deducts the flux blank value during analysis to support accurate measurement results.

Comprehensive Data and System Display

The software provides access to:

  • Release curve comparison and storage

  • Analytical result statistics

  • Quick data searches

  • Maintenance reminders

  • Monitoring of key instrument parameters

Additional Diagnostic Checks

Solenoid Valve Check:
Displays the operating status of individual solenoid valves and allows each valve to be operated independently.

Signal Acquisition Check:
Monitors the acquisition signals throughout the analyzer system.

High-Frequency Status Check:
Provides high-frequency furnace preheating countdown information.

Baseline Check:
Provides real-time monitoring of the baseline for each infrared detection channel.

Automatic Zero Check:
Software-controlled automatic baseline zeroing helps maintain stable detection conditions.


Features of the Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3G

The QualiCSA™ 3G Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer combines high-frequency induction combustion and tubular resistance furnace technology with infrared gas detection for carbon and sulfur analysis across a broad range of solid materials.

Key Features

  • Germany-produced solid-state infrared detector components

  • Flexible heating power control

  • Full manual operating mode

  • Advanced infrared thermostatic technology

  • High-precision gas flow control

  • Dedicated computer operating software

  • Advanced linear signal processing

  • High analytical precision

  • Reliable electronic circuit components

  • Comprehensive self-diagnostic functions

  • Multiple circuit protection systems

  • Fully enclosed gas channel design with zero dead volume

Infrared absorption following high-frequency combustion or tubular furnace combustion enables rapid analysis of carbon and sulfur concentrations in solid inorganic materials.

Software Functions

The QualiCSA™ 3G software provides comprehensive instrument control and data management functions, including:

  • Monitoring solenoid valve movement throughout the gas channels

  • Detection and adjustment of infrared signals

  • Rapid display of analytical results and release curves

  • Automatic storage of analytical results

  • Generation and storage of dynamic release curves

  • Automatic specimen weight reading

  • Manual specimen weight entry when required

  • Automatic switching between high-carbon, low-carbon, and sulfur detection channels

Data Processing and Analysis

The software supports multiple approaches for reviewing and processing analytical data:

  • Data retrieval by date or specimen ID

  • Data screening and filtering

  • Statistical processing, including mean, standard deviation, and relative deviation

  • Comparison of analytical signals with stored release curves

High-Precision Flow Control

The analyzer uses high-precision electronic flow control technology with an Anti-Overshoot System to provide precise control of the analysis gas flow during measurement.

Catalytic Oxidation in the Copper Furnace

Before entering the carbon detection cell, the analysis gas passes through the copper furnace for catalytic oxidation. This process converts CO into CO₂, supporting detection of the carbon-containing gases generated during combustion.

The copper furnace also converts analyzed SO₂ into SO₃, which is subsequently absorbed to help reduce air emissions.

Automatic Dust Filtration

A specialized dust filter made from powder metallurgy materials removes particulate matter from the analysis gas. The filter is automatically cleaned twice during each analysis cycle.

Automatic Self-Check and Diagnostics

The QualiCSA™ 3G provides comprehensive self-checking functions to monitor key operating conditions, including:

  • Overall oxygen pressure at the furnace inlet

  • Analysis pressure at the rear of the furnace

  • Dynamic gas pressure

  • High-frequency furnace on/off status

  • Cleaning device reset status within the high-frequency furnace

  • Infrared signal monitoring and adjustment

  • Solenoid valve movement throughout the gas channels

The software provides step-by-step diagnostic functions, allowing individual components and systems to be checked as needed.

Electronic Specimen Weighing

An electronic balance can be connected directly to the computer for accurate specimen weighing. The measured weight is automatically transferred to the analysis software. Manual specimen weight entry is also available when required.

Typical Analysis Time

  • High-frequency induction furnace: 40–60 seconds

  • Tubular resistance furnace: 150–300 seconds

Crucible and Combustion Vessel

High-Frequency Induction Furnace:

  • Ceramic crucible

  • Diameter: 25 mm

  • Height: 27 mm

Tubular Resistance Furnace:

  • Porcelain combustion boat

  • Length: 87 mm

  • Width: 12 mm

  • Height: 10 mm

Combustion Furnace Specifications

High-Frequency Induction Furnace:

  • Frequency: 18 MHz

  • Maximum power: 2.7 kVA

Tubular Resistance Furnace:

  • Maximum temperature: 1550°C

  • Maximum power: 4.4 kW

  • Carborundum heating elements

  • Controlled heating power to support extended element life

  • Furnace case reaches operating temperature in approximately 20 minutes

Crucible Pre-Treatment

The ceramic crucible used with the high-frequency induction furnace can be pre-treated in the tubular resistance furnace. This dual-purpose configuration improves workflow efficiency while supporting consistent and reliable carbon and sulfur analysis.

Theory and Method

Instrument Principle – QualiCSA™ 3G Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer

The QualiCSA™ 3G Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer uses infrared absorption analysis following high-temperature combustion. Depending on the specimen and testing requirements, users can select either the tubular resistance furnace or high-frequency induction furnace as the specimen treatment and combustion unit.

After gas purification, oxygen is introduced into the selected combustion furnace as the carrier gas. The specimen undergoes high-temperature oxidation, generating CO₂, CO, and SO₂. The combustion gases then pass through dust removal and dehydration stages before entering the sulfur detection system.

The oxygen and resulting gas mixture subsequently pass through a heated catalytic furnace. During catalytic oxidation, CO is converted to CO₂, while SO₂ is converted to SO₃. After sulfur removal, the gas mixture is directed sequentially through the high-carbon detection cell and low-carbon detection cell for carbon measurement.

After the detection process is complete, the remaining gas is discharged from the analyzer.

The measured carbon and sulfur concentrations are displayed by the analysis software as % C and % S. Analytical results are automatically stored in the system database for convenient future retrieval.

The software can also generate customized analysis reports when required. Reports can be printed through an external printer, supporting laboratory documentation and record keeping.

With its dual combustion furnace configuration, infrared detection technology, automated data processing, and straightforward operation, the QualiCSA™ 3G Carbon & Sulfur Analyzer provides rapid carbon and sulfur analysis for a wide range of solid materials while simplifying routine operation and maintenance.


High-Frequency Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3

Flexible Analytical Parameter Settings

The QualiCSA™ 3 High-Frequency Infrared Carbon & Sulfur Analyzer allows analytical parameters to be adjusted according to the characteristics and requirements of different specimens.

Calibration Methods and Parameters

Calibration methods and analytical parameters can be established and stored separately for different specimen types. The software supports an unlimited number of analytical methods, allowing laboratories to configure testing procedures for a wide range of materials.

Advanced Data Management

The QualiCSA™ 3 includes comprehensive data management functions designed to simplify analytical record keeping, data retrieval, reporting, and laboratory connectivity.

  • Database Storage: Analytical results are stored in a database for flexible data searches and statistical analysis.

  • Customizable Printing: Report and printing columns can be configured according to specific user requirements.

  • Excel Data Export: Current analytical data can be exported directly to Excel from the analysis interface.

  • LIMS Connectivity: Network-based data transmission supports integration with a Laboratory Information Management System (LIMS) for streamlined laboratory data management.

Carbon & Sulfur Analyzer

Automatic Cleaning of the High-Frequency Furnace

The QualiCSA™ 3 High-Frequency Infrared Carbon & Sulfur Analyzer features an integrated metal dust filtration system designed for convenient cleaning and efficient furnace operation.

  • Tool-Free Dust Filter Cleaning: The dedicated metal dust filter can be removed and cleaned without specialized tools, simplifying routine maintenance and reducing cleaning time.

  • Automatic Combustion Chamber Cleaning: The combustion chamber is automatically cleaned twice during the analysis process, with dust removed after each analysis cycle.

  • Automatic Filter Back-Blow: The dust filter is automatically back-blown to reduce dust accumulation and maintain effective filtration and adsorption performance.

  • Reduced Maintenance: Automated dust removal helps maintain stable combustion conditions and supports consistent carbon and sulfur analysis over repeated testing cycles.

Carbon & Sulfur Analyzer

Infrared Detection Unit

The QualiCSA™ 3 High-Frequency Infrared Carbon & Sulfur Analyzer features a non-dispersive infrared detection system with highly sensitive pyroelectric solid-state infrared detectors for carbon and sulfur analysis. The computer automatically calibrates the infrared cell zero point to support stable and accurate measurement.

  • Non-Dispersive Infrared Detection: High-sensitivity pyroelectric solid-state detectors provide reliable infrared signal measurement for carbon and sulfur analysis.

  • Automatic Zero Calibration: The software automatically calibrates the infrared cell zero point, helping maintain stable baseline conditions during analysis.

  • Three Independent Infrared Channels: The standard QualiCSA™ 3 configuration includes three independent infrared detection channels.

  • Expandable Detection Capacity: The system can be expanded to four independent infrared channels based on application requirements, supporting full-range carbon and sulfur detection.

Carbon & Sulfur Analyzer

Automatic Switching Between High and Low Ranges

The CS3500 Carbon & Sulfur Analyzer features advanced electronic flow control technology designed for rapid response and stable analysis gas flow. High-precision electronic flow regulation continuously supports controlled gas flow conditions, helping maintain measurement consistency and analytical accuracy.

The system's responsive flow control contributes to reliable switching and measurement across high and low detection ranges, supporting precise carbon and sulfur analysis across different concentration levels.

Carbon & Sulfur Analyzer

Carbon Sulfur Analyzer - QualiCSA™ 3 Working principle:

Carbon & Sulfur Analyzer

Structure of the Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer – QualiCSA™ 3G

The QualiCSA™ 3G Dual Combustion Furnace Infrared Carbon & Sulfur Analyzer features a modular instrument design that integrates the major components required for carbon and sulfur analysis. The system configuration includes an electronic balance, computer, printer, high-frequency induction combustion unit, tubular resistance furnace unit, vacuum cleaner, and other supporting modules.

This modular configuration provides a practical setup for laboratories performing carbon and sulfur analysis across different solid sample types.

Infrared Detection System

The QualiCSA™ 3G uses an infrared absorption detection system designed to provide flexible carbon and sulfur measurement according to application requirements.

  • Three-Channel Standard Configuration: The standard configuration includes three independent infrared absorption cells, providing three physical detection channels: two carbon channels and one sulfur channel.

  • Four-Channel Configuration: Based on application requirements, the QualiCSA™ 3G can be configured with four independent infrared absorption cells, providing two carbon channels and two sulfur channels for expanded detection capability.

  • Pyroelectric Infrared Detector: The analyzer uses a German-produced pyroelectric solid-state infrared detector for sensitive infrared signal detection.

  • Synchronous Motor: A Swiss-produced synchronous motor provides stable operation of the infrared detection system.

  • Infrared Light Source: A stable, oxidation-resistant infrared light source produced in the United States supports consistent optical performance.

  • Constant-Temperature Control: The entire infrared detection chamber is thermostatically controlled to maintain a stable analysis temperature, supporting measurement accuracy and detection stability.

  • Oxygen Shielding Gas: Oxygen is used to protect and purify the infrared light source and detector by isolating these components from the surrounding atmosphere. This helps improve analytical stability and detection accuracy.

Typical Data (tube furnace):

Name of the Specimen and Content of Carbon and Sulfur: C61.46; S4.34
Specimen ID Carbon Mass Fraction Sulfur Mass Fraction
1 61.486 4.410
2 61.286 4.385
3 61.506 4.435
4 61.518 4.293
5 61.471 4.354

Software Interface:

Carbon & Sulfur Analyzer

Main analysis Window

Carbon & Sulfur Analyzer

Method window

Carbon & Sulfur Analyzer – QualiCSA™ 3 Technical Specification

Carbon Sulfur Analyzer QualiCSA™ 3 and QualiCSA™ 3G Technical Specifications:

Model QualiCSA™ 3 QualiCSA™ 3G
Analysis Range

High-frequency induction furnace (500mg sample):

  • LC: 1ppm~0.1%
  • HC: 0.1%~5%
  • LS: 1ppm~0.3%
  • HS (150mg sample): 0.3%~30%

Note: Changing the sample size can extend the analysis range up to 100% High sulfur absorption pools channel can be customized according to customer needs

High Frequency Induction Furnace(500mg Sample):

  • LC: 1ppm - 0.1%
  • HC: 0.1%~5%
  • LS: 1ppm - 0.3%
  • HS (150mg Sample): 0.3%~ 30%

Tubular Resistance Furnace(500mg Sample):

  • C: 0.01% ~20%
  • S: 0.005% ~20%

Note: The measurement range can be changed by changing the measurement quantity.

The number of detection cells and sizes can be determined in accordance with the content of carbon and sulfur in specimens of users

     
   
     
Analysis Accuracy

High-frequency induction furnace:

  • LC: 1ppm or RSD ≤ 1%
  • HC: RSD ≤ 0.5%
  • LS: 1.5ppm or RSD ≤ 1.5%
  • HS: RSD ≤ 1.5%

High-Frequency Induction Furnace:

  • LC: 1ppm or RSD≤1%
  • HC: RSD≤0.5%
  • LS: 1.5ppm or RSD≤1.5%
  • HS: RSD≤1.5%

Tubular Resistance Furnace:

  • LC: RSD≤1%
  • HC: RSD≤0.5%
  • LS: RSD≤1.5%
  • HS: RSD≤1.5%
Sensitivity 0.01ppm
Analysis Time 40 ~ 60 seconds

High-Frequency Induction Furnace:

  • 40-60 seconds Tubular Resistance Furnace:
  • 150-300 seconds
Sample Quality

Recommended sample weight:

  • 0.1g to 0.5g, can be adjusted based on carbon and sulfur content

High-Frequency Induction Furnace:

  • 0.1g-0.5g Tubular Resistance Furnace:
  • 300mg/coal(typical value)
Combustion Furnace

High-frequency induction furnace:

  • 18MHz, 2.7KVA

High-Frequency Induction Furnace:

  • 18MHz 2.7KVA

Tubular Resistance Furnace:

  • Max.20A,Max.1550 ℃, the temperature can be adjusted continuously
Dust cleaning The dust in the combustion tube of the high frequency induction furnace is wiped off automatically
Detector Solid-state pyroelectric detector
Carrier Gas Oxygen purity: ≥ 99.5%; 0.2-0.4Mpa Oxygen 99.5%, 3L/min
Power Gas Nitrogen (industrial grade) Nitrogen or Compressed Air
Voltage

Power Supply of the Analyzer:

  • 220VAC±10% 50±1Hz 16A (110V is also available)

Power Supply of the Analyzer:

  • 220VAC ±10%,50±1Hz,16A (110V is also available)

Power Supply of the Resistance Furnace:

  • 220VAC ±10%, 50±1Hz, 20A (110V is also available)
Weight Approximately 100kg

High-Frequency Induction Furnace: 

  • 100kg

Tubular Resistance Furnace: 

  • 30k
Dimensions (width × depth × height) 55 × 76 × 77 cm

The Analyzer:

  • 55 x 77 x 76 (cm)

Resistance Furnace:

  • 33× 52 × 60 (cm)

Resolution of the Electronic Balance:

  • 0.1mg
Chemical Reagent   Magnesium perchlorate, CO2 absorbent

O prazo de entrega varia conforme a disponibilidade em estoque. Nossos prazos padrão de despacho e envio são geralmente de até 1 semana, porém, para alguns itens de alta demanda, a entrega pode ser estendida para 2 a 3 semanas. Caso precise desses itens com urgência, entre em contato conosco para verificar a disponibilidade em estoque e providenciar métodos de envio mais rápidos.

🚚

Informações importantes sobre a entrega

O prazo de entrega varia de acordo com a disponibilidade em estoque. Nossos prazos padrão de despacho e envio são geralmente de dentro de 1 semana, no entanto, para alguns itens de alta demanda, a entrega pode ser estendida para 2 a 3 semanas.

Precisa com urgência? Entre em contato conosco aqui para verificar a disponibilidade em estoque e organizar um envio mais rápido.

Pedidos:
O comprador reconhece que, ao fazer um pedido no Qualitest:

C. O comprador tem plena autoridade para celebrar o contrato em nome da entidade, e essa concessão de autoridade foi indicada pelo comprador ao realizar o pedido por meio da Qualitest.
D. Uma taxa mínima de manuseio será aplicada ao valor total do frete para todos os pedidos.

Envio dentro dos EUA:

Todos os pedidos serão enviados da melhor maneira possível, com frete pré-pago, via transportadora para pacotes menores ou via transportadora para caixas maiores. Uma taxa de manuseio pode ser aplicada aos pedidos. A propriedade da mercadoria é transferida para o comprador no momento da entrega à transportadora. Perdas ou danos durante o transporte são de responsabilidade do comprador. A Qualitest USA fornecerá assistência com as informações necessárias para o processamento de reclamações.

Envio para fora dos EUA:

Todos os pedidos serão enviados da melhor maneira possível, via transportadora para pacotes menores ou via agentes de carga para caixas maiores. Uma pequena taxa de manuseio pode ser aplicada. A propriedade da mercadoria é transferida para o comprador no momento da entrega à transportadora. Perdas ou danos durante o transporte são de responsabilidade do comprador. A Qualitest USA fornecerá assistência com as informações necessárias para o processamento de reclamações. Taxas de exportação, impostos, taxas alfandegárias e desembaraço aduaneiro são de responsabilidade do comprador.

O seguro de envio não está incluído. Entre em contato com nossos representantes de vendas caso precise de seguro de envio.

Envio parcial: A Qualitest USA reserva-se o direito de fazer envios parciais, a menos que o comprador instrua o contrário.

Condições de pagamento: Todos os pagamentos à Qualitest USA devem ser feitos em dólares americanos (USD).

B. Transferência Bancária - A transferência deve ser feita para a Qualitest e confirmada no valor total da compra (mercadoria, manuseio e frete) antes do envio. Entre em contato conosco pelo telefone 1.877.884.TEST (8378) (fora dos EUA +1.905.944.9825) ou pelo fax +1.954.697.8211 para obter informações bancárias.
C. Conta Aberta - Disponível apenas para clientes dos EUA e Canadá. As condições para contas abertas são de 30 dias a partir da data de envio. A Qualitest USA reserva-se o direito de recusar o envio de novos pedidos se houver faturas em aberto com mais de 30 dias de atraso. Os compradores podem solicitar uma conta aberta fornecendo:

suas informações bancárias
3 referências de crédito de outros fornecedores
Por favor, aguarde 5 dias úteis para a confirmação do crédito e criação de uma conta aberta.

Política de Devolução:

A Qualitest USA poderá aceitar a devolução de mercadorias adquiridas na América do Norte para reembolso ou crédito, sob as seguintes condições -

  • Poderá ser cobrada uma taxa adicional de reabastecimento na transação se os itens já tiverem sido enviados ao cliente.
  • Todos os custos de frete, taxas alfandegárias e outras despesas de envio relacionadas à mercadoria devolvida são de responsabilidade do comprador. Envios com frete a cobrar serão recusados.
  • A mercadoria deve ser devolvida devidamente embalada, em estado de nova e própria para venda, juntamente com a embalagem original e toda a documentação, acessórios e certificados.
  • O comprador confirmou a autorização de devolução diretamente com a Qualitest.
  • A mercadoria é um item de catálogo regular. Itens de encomenda especial não podem ser devolvidos.
  • Todas as mercadorias devolvidas estão sujeitas à inspeção da Qualitest. A Qualitest reserva-se o direito de recusar a devolução de qualquer mercadoria que esteja usada, danificada ou que não faça parte da lista de preços publicada atualmente. Caso a Qualitest não aceite a mercadoria devolvida, serão feitos esforços razoáveis ​​para notificar o Comprador e a mercadoria será devolvida ao Comprador da mesma forma que foi recebida pela Qualitest. Mercadorias danificadas que possam ser restauradas à sua condição original e, portanto, aceitas para devolução, serão avaliadas individualmente. O comprador será informado sobre as despesas adicionais para o reparo e restauração do item devolvido. Após a aprovação, essas despesas serão cobradas do comprador, além da taxa de reabastecimento.


Alteração dos Termos:

A aceitação de qualquer pedido pela Qualitest USA está sujeita à aprovação do comprador. Ao efetuar um pedido à Qualitest, o comprador concorda com todos os termos e condições aqui estabelecidos. A concordância do comprador com estes termos e condições será presumida a partir do momento em que o comprador fizer um pedido à Qualitest. Quaisquer outros termos e condições são expressamente rejeitados, e nenhuma adição ou modificação dos termos e condições será vinculativa sem o prévio acordo por escrito da Qualitest USA.

Acordo Completo:

Os termos e condições do site da Qualitest, incorporados aqui por referência, incluindo formulários, confirmações, orçamentos, faturas e termos e condições de venda, constituem o acordo integral e exclusivo entre o comprador e Qualitest USA LC.

Informações:

A Qualitest USA se esforça ao máximo para garantir a precisão das informações sobre os produtos exibidas em seus sites, mas não oferece garantias, expressas ou implícitas, quanto à precisão dos dados apresentados nos sites. A Qualitest USA reserva-se o direito de alterar as informações sobre os produtos, incluindo informações sobre preços, a qualquer momento, sem aviso prévio.

Marcas registradas e direitos autorais:

O site WorldofTest.com Qualitest contém nomes de produtos com marcas registradas. Os nomes dos produtos não devem ser reproduzidos ou usados ​​de qualquer forma por terceiros, exceto pela Qualitest, sem o consentimento expresso por escrito da Qualitest International Inc. Todas as imagens, descrições e outros conteúdos deste site são protegidos por direitos autorais da Qualitest USA e não podem ser usados ​​sem a permissão expressa por escrito da Qualitest USA. O comprador reconhece que não possui nenhum direito, título ou interesse nas marcas registradas ou direitos autorais dos produtos e se compromete a não tomar nenhuma medida para registrar ou interferir de qualquer outra forma com tais direitos. Entre em contato conosco para quaisquer solicitações de permissão ou dúvidas sobre nossas marcas registradas.

Aviso de Isenção de Garantia:

Nenhuma garantia ou afirmação de fato, expressa ou implícita, além daquelas expressamente estabelecidas neste documento, é feita ou autorizada pela Qualitest USA. A Qualitest USA se isenta de toda e qualquer responsabilidade por reclamações de defeitos de produtos. A Qualitest USA não expressa ou implica uma garantia de que qualquer produto em seu(s) site(s) seja adequado para uma finalidade específica. A Qualitest USA honra a garantia do produto conforme publicada e disponibilizada pela Qualitest USA. Reclamações de garantia para produtos não fabricados pela Qualitest são de responsabilidade do fabricante. A Qualitest USA sempre fará o possível para resolver as reclamações de garantia.


Força Maior:

A Qualitest USA não será responsável por qualquer atraso ou prejuízo no desempenho resultante, total ou parcialmente, de casos fortuitos, interrupções de serviço, greves, insurreições, decretos ou controles governamentais, riscos de guerra, condições climáticas severas, falta de suprimentos ou matérias-primas, impossibilidade de adquirir ou enviar produtos, impossibilidade de obter permissões e/ou licenças, ou quaisquer outras circunstâncias ou causas fora do controle da Qualitest USA na condução de seus negócios. 

Política de Privacidade da Qualitest USA 

I. Quais disposições legais regem nossas práticas de processamento de dados? Como e de onde (fontes internas/externas) os dados pessoais são adquiridos? Quais são os direitos do usuário (visitante do site/cliente cadastrado)? 

1. Geral
Como princípio geral, não é necessário fornecer dados pessoais ao visitar nosso site. Os dados que você nos disponibiliza são tratados com estrita confidencialidade e em conformidade com as disposições da Lei Federal de Proteção de Dados. Com algumas exceções (ver ponto 2 abaixo), nosso servidor web registra apenas dados não pessoais (anônimos) referentes ao uso do nosso site. Especificamente, os arquivos de log do nosso servidor web, em regra geral, contêm apenas o endereço IP do usuário, a última página visitada, o navegador utilizado, a data, a hora e o arquivo solicitado. Esses dados anônimos, contudo, não permitem tirar conclusões sobre os usuários individualmente e servem apenas para elaborar estatísticas sobre o uso do nosso site com o objetivo de aprimorá-lo. Ao mesmo tempo, damos grande importância a garantir que os dados de uso não sejam vinculados a dados pessoais. 

2. Dados pessoais

Os dados pessoais são utilizados apenas se a newsletter for solicitada (por e-mail), se um ou mais produtos forem encomendados ou para fornecer informações sobre os produtos. Comprometemo-nos a utilizar os dados pessoais que nos forem confiados apenas para os fins indicados. O histórico de compras é conservado para auxiliar no atendimento de futuras necessidades do cliente. 

II. Quais medidas de segurança são utilizadas para proteger os dados pessoais? Quais são as opções do usuário para o processamento de dados pessoais? 

3. Medidas técnicas

As bases de dados são protegidas de forma otimizada contra o acesso, perda, uso indevido e falsificação por terceiros, através da utilização de meios técnicos adequados. Para determinar a popularidade de determinadas áreas temáticas, são utilizados cookies nessas seções. Esses arquivos de texto são armazenados no seu disco rígido e facilitam a sua utilização do nosso site. Graças a esses cookies, não é necessário um registo específico cada vez que visita uma seção que exige registo, e podemos fornecer-lhe o conteúdo personalizado que solicita. Você decide se deseja trabalhar com cookies e, em caso afirmativo, qual tipo (armazenados permanentemente no disco rígido ou apenas durante a atividade do navegador). No entanto, alertamos que o acesso a campos que exigem cadastro só é possível com os cookies ativados. 

III. Quais dados são comunicados a terceiros e para quais fins? 

4. Comunicação de dados pessoais

Os dados pessoais que você nos confia não são comunicados, alugados ou vendidos a terceiros. 

IV. Qual departamento responde a perguntas sobre o processamento de dados pessoais? 

5. Contato

Em virtude dos rápidos avanços tecnológicos relacionados à Internet, envidamos todos os esforços para aprimorar constantemente nosso site e as precauções técnicas, incluindo aquelas relacionadas à proteção de dados. Manteremos você devidamente informado sobre tais medidas. Quaisquer alterações serão publicadas aqui. Mais informações estão disponíveis a qualquer momento entrando em contato com a Qualitest USA.

Isenção de responsabilidade A Qualitest USA não será responsável por perdas diretas, indiretas ou consequenciais resultantes ou relacionadas ao acesso, uso ou consultas ao site da Qualitest ou seus links com outros sites, mesmo que a Qualitest USA tenha sido previamente informada da possibilidade de tais perdas. Nenhuma garantia é fornecida quanto à precisão das informações divulgadas por meio do site da Qualitest USA. Além disso, a Qualitest USA não garante a confiabilidade nem a integridade das informações contidas em seu site. As informações disponibilizadas nos sites da Qualitest e WorldofTest.com podem ser alteradas a qualquer momento sem aviso prévio. Em particular, a Qualitest USA não será responsável por perdas causadas por erros de transmissão, falhas técnicas e interrupções, avarias ou interferência ilícita no sistema de processamento de dados do usuário ou nos sistemas e redes de transmissão geralmente acessíveis. A Qualitest USA também não será responsável por perdas resultantes de avarias, interrupções ou sobrecargas que ocorram em quaisquer sistemas de processamento de dados. Se determinados links forem ativados no site da Qualitest e do WorldofTest.com, o usuário poderá, em certas circunstâncias, sair do site da Qualitest. A Qualitest USA não assume qualquer responsabilidade pelo conteúdo, produtos ou serviços oferecidos ou outras informações ou ofertas contidas nesses sites vinculados.

Produtos Relacionados