{"product_id":"ozone-test-chamber-ozonetest-uv-for-testing-rubber-deterioration","title":"Ozone Test Chamber – OzoneTest UV for testing Rubber Deterioration","description":"\u003ch2\u003eOzone Test Chamber – OzoneTest UV for Testing Rubber Deterioration\u003c\/h2\u003e\n\u003cp\u003eThe Ozone Test Chamber – OzoneTest UV for Testing Rubber Deterioration is a comprehensive ozone cabinet designed to comply with ASTM D1149 and ISO 1431 standards. It is used to evaluate the resistance of rubber samples and technical articles to cracking when subjected to static or dynamic tensile strain.\u003c\/p\u003e\n\u003cp\u003eThe Ozone Test Chamber allows users to customize test conditions according to internationally recognized standard methods, supporting controlled testing of rubber materials under ozone exposure.\u003c\/p\u003e\n\u003ch3\u003eWhy Choose Ozone Test Chamber – OzoneTest UV for Testing Rubber Deterioration?\u003c\/h3\u003e\n\u003ch4\u003eOverview\u003c\/h4\u003e\n\u003cp\u003eThe Ozone Test Chamber – OzoneTest UV is a comprehensive ozone cabinet designed to adhere to ASTM D1149 and ISO 1431 standards. It is used to measure the resistance of rubber samples or technical articles to cracking when subjected to static or dynamic tensile strain. The instrument allows test conditions to be customized to align with internationally recognized standard methods.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/Ozone_Test_Chamber_OzoneTest_U_9.webp?v=1790703871\" alt=\"Ozone Test Chamber – OzoneTest UV for testing Rubber Deterioration\"\u003e\u003c\/p\u003e\n\u003ch4\u003eTest Conditions\u003c\/h4\u003e\n\u003cp\u003eThe Ozone Test Chamber – OzoneTest UV allows adjustment of the following test parameters:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eOzone Concentration: Adjustable from 10 to 500 parts per hundred million (pphm) using the UV absorption detector.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTest Temperature: Adjustable from ambient temperature +5°C to +70°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAir Flow in the Test Chamber: Adjustable from 1 to 3 air changes per minute.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOzone Test Chamber – OzoneTest UV for Testing Rubber Deterioration Features\u003c\/h3\u003e\n\u003ch4\u003eKey Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAutomated control of ozone concentration, temperature, and air flow.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports both static and dynamic testing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUses a UV-absorption ozone detector for ozone concentration measurement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFeatures a stainless steel cylindrical test chamber designed to provide even ozone distribution.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOzone generation and elimination take place within a closed circuit, eliminating the need for exhaust evacuation.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eComplies with CE labeling standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSoftware\u003c\/h3\u003e\n\u003ch4\u003eOzone Test Chamber – OzoneTest UV for Testing Rubber Deterioration Software\u003c\/h4\u003e\n\u003cp\u003eThe software enables users to:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCreate personalized test procedures by defining parameters such as ozone concentration, temperature, air change count, test duration, and humidity level.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatically calibrate the instrument according to the defined parameters of the selected test procedure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMonitor and visualize ozone concentration, humidity, and temperature curves throughout the test.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePreserve test curves and images by importing them into the SQL database.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/Ozone_Test_Chamber_OzoneTest_U.webp?v=1790703332\" alt=\"Ozone Test Chamber – OzoneTest UV for testing Rubber Deterioration\"\u003e\u003c\/p\u003e\n\u003ch4\u003eTest Report\u003c\/h4\u003e\n\u003cp\u003eThe test report can be printed or saved as a PDF file in any of the supported languages. Users can also customize the test report format according to their preferences.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/Ozone_Test_Chamber_OzoneTest_U_1.webp?v=1790703367\" alt=\"Ozone Test Chamber – OzoneTest UV for testing Rubber Deterioration\"\u003e\u003c\/p\u003e\n\u003ch4\u003eTest Procedures\u003c\/h4\u003e\n\u003cp\u003eTest procedures define the specific test conditions, including:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eOzone concentration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTest temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAirflow rate\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTest duration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRelative humidity concentration (optional)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eOnce a test procedure is selected, the instrument automatically adjusts according to the defined test conditions.\u003c\/p\u003e\n\u003cp\u003eUsers can duplicate and modify existing test procedures or create fully customized procedures using the Datagest program, which is installed together with the OzoneCheck program.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/Ozone_Test_Chamber_OzoneTest_U_2.webp?v=1790703397\" alt=\"Ozone Test Chamber – OzoneTest UV for testing Rubber Deterioration\"\u003e\u003c\/p\u003e\n\u003ch3\u003eOzone Test Chamber – OzoneTest UV for Testing Rubber Deterioration Construction Technology\u003c\/h3\u003e\n\u003ch4\u003eUV Ozone Detector\u003c\/h4\u003e\n\u003cp\u003eThe UV ozone detector used for ozone concentration measurement conforms to ISO 1431-3 and ASTM D4575 standards.\u003c\/p\u003e\n\u003cp\u003eThe device:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eContinuously monitors the ozone concentration inside the test chamber.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePerforms self-calibration every 30 seconds by comparing the measurement of ozonated air with pure air.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControls ozone generation within the test chamber through PID control, ensuring that the required test conditions are reached within the timeframes specified by the standard while minimizing oscillations.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe device can be supplied with an official calibration certificate issued by an accredited laboratory.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/Ozone_Test_Chamber_OzoneTest_UV_for_testing_Rubber_Deterioration_Ozone_Detector.gif?v=1790703482\" alt=\"Ozone Test Chamber – OzoneTest UV for testing Rubber Deterioration\"\u003e\u003c\/p\u003e\n\u003ch4\u003eTest Chamber\u003c\/h4\u003e\n\u003cp\u003eThe Ozone Test Chamber is equipped with a cylindrical test chamber featuring symmetrical air extraction through a double-chamber system. This distinctive design provides even dispersion of ozonized air throughout the chamber, which is not achievable with a cubic chamber.\u003c\/p\u003e\n\u003cp\u003eThe test chamber is constructed from stainless steel and features front inspection windows with two lateral lights. These features allow users to inspect samples throughout the testing process without stopping the test or removing the samples from the chamber.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/Ozone_Test_Chamber_OzoneTest_U_6.webp?v=1790703504\" alt=\"Ozone Test Chamber – OzoneTest UV for testing Rubber Deterioration\"\u003e\u003c\/p\u003e\n\u003ch4\u003eSupport for Static Traction Test\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eEquipped with a sample holder for 2–4 samples subjected to static strain, with adjustable grip distances.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes a static test piece holder with a planetary effect, aligned with ISO 1431-1 standards. This mechanism moves the test pieces throughout the entire chamber volume, providing uniform exposure to the ozone atmosphere.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe device can accommodate up to 64 samples, each with a width of 10 mm, for simultaneous testing.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/OZONE_TEST_CHAMBER_-_OZONETEST_U.webp?v=1790703528\" alt=\"Ozone Test Chamber – OzoneTest UV for testing Rubber Deterioration\"\u003e\u003c\/p\u003e\n\u003ch4\u003eSupport for Static Traction Testing of Rubber Hoses\u003c\/h4\u003e\n\u003cp\u003eSample holders are designed to support static traction testing of rubber hoses in accordance with ISO 7326, Methods 1 and 2.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/Ozone_Test_Chamber_OzoneTest_U_7.webp?v=1790703555\" alt=\"Ozone Test Chamber – OzoneTest UV for testing Rubber Deterioration\"\u003e\u003c\/p\u003e\n\u003ch4\u003eSupport for Dynamic Testing\u003c\/h4\u003e\n\u003cp\u003eThe system complies with ASTM D1149, ISO 1431, and SAE J1401 standards. It is designed to be inserted into the test chamber for evaluating the ozone resistance of cured rubber under dynamic conditions, with a testing range of 3 to 30 cycles per minute (0.05 to 0.5 Hz).\u003c\/p\u003e\n\u003cp\u003eThe system can simultaneously test up to 10 samples.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/OZONE_TEST_CHAMBER_-_OZONETEST_U_1.webp?v=1790703581\" alt=\"Ozone Test Chamber – OzoneTest UV for testing Rubber Deterioration\"\u003e\u003c\/p\u003e\n\u003ch4\u003eManagement of Test Results\u003c\/h4\u003e\n\u003cp\u003eAll test results and associated test curves generated during testing are stored in the SQL database and can be accessed through the Datagest program.\u003c\/p\u003e\n\u003cp\u003eDatagest functions as the Laboratory Information Management System (LIMS) and is consistently installed alongside the instrument-control programs. It provides a central repository for test results generated by connected instruments and supports efficient management of shared resources used by the instruments, including Product Lists, Customer Lists, Tolerance Limits, Order Lists, and more.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/OZONE_TEST_CHAMBER_-_OZONETEST_U_2.webp?v=1790703604\" alt=\"Ozone Test Chamber – OzoneTest UV for testing Rubber Deterioration\"\u003e\u003c\/p\u003e\n\u003ch4\u003eIndustry 4.0 Integration\u003c\/h4\u003e\n\u003cp\u003eBoth the instrument and software are designed to support seamless integration with various working environments. The SQL-format database, together with the Company_Connect program, enables synchronization between your company's management software and the database.\u003c\/p\u003e\n\u003cp\u003eThis integration streamlines test identification and supports the use of barcode readers or similar devices, helping improve efficiency within the testing workflow.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/Ozone_Test_Chamber_OzoneTest_U_8.webp?v=1790703627\" alt=\"Ozone Test Chamber – OzoneTest UV for testing Rubber Deterioration\"\u003e\u003c\/p\u003e\n\u003ch4\u003eResuming Tests After Unintended Interruption\u003c\/h4\u003e\n\u003cp\u003eThe instrument consistently retains its operational settings. In the event of a power outage, users can restart the program and seamlessly resume the paused test.\u003c\/p\u003e\n\u003ch4\u003eStandard Calibration Service for Ozone Cabinet\u003c\/h4\u003e\n\u003cp\u003eThe standard calibration service for the ozone cabinet follows the specifications outlined in the ISO 1431 standard.\u003c\/p\u003e\n\u003cp\u003eThe service package includes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eRoutine maintenance of the instrument.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThorough cleaning of the ozone detector, including replacement of internal filters.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration of the test chamber temperature at 40°C.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration of ozone concentration within the test chamber at 50 pphm, 100 pphm, 150 pphm, and 200 pphm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration of the time required to reach the set ozone concentration (NEW).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration of relative humidity within the chamber at 50% and 75% (only applicable to instruments with humidity control).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFinal verification of the instrument's proper functionality.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIssuance and email delivery of the Calibration Certificate, demonstrating traceability to primary standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSafety Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe instrument automatically secures its opening when the ozone concentration exceeds 10 pphm, helping prevent inadvertent exposure to ozonized air.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOzonized airflow generation and distribution take place within a closed circuit, in accordance with safety regulations and eliminating the need for an aspiration system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSafety sensors prevent the instrument from reaching extreme temperature and humidity levels resulting from incorrect settings.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEquipped with a Safety Push-button.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe instrument is supplied with CE Labelling to certify its adherence to safety standards.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/OZONE_TEST_CHAMBER_-_OZONETEST_U_3.webp?v=1790703658\" alt=\"Ozone Test Chamber – OzoneTest UV for testing Rubber Deterioration\"\u003e\u003c\/p\u003e\n\u003ch4\u003eHardware Requirements\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe programs are compatible with standard PCs running Windows 10 or Windows 11.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe instruments connect to the PC using the USB cable supplied with the instrument.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eThe programs are designed to be compatible with antivirus software and other programs already installed on the PC.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/OZONE_TEST_CHAMBER_-_OZONETEST_U_4.webp?v=1790703692\" alt=\"Ozone Test Chamber – OzoneTest UV for testing Rubber Deterioration\"\u003e\u003c\/p\u003e\n\u003ch4\u003eDevelopment and Production\u003c\/h4\u003e\n\u003cp\u003eThe Ozone Test Chamber – OzoneTest UV for Testing Rubber Deterioration undergoes complete development and manufacturing at our WorldofTest partner, Gibitre’s state-of-the-art facility in Italy and Europe, with global support.\u003c\/p\u003e\n\u003cp\u003eAll mechanical components are manufactured in the company workshop using state-of-the-art CNC machines. To support measurement reliability, components and sensors from reputable brands are carefully selected. Well-trained internal personnel oversee every stage of production, including assembly, initiation, calibration, packaging, shipping, and installation.\u003c\/p\u003e\n\u003ctable class=\"table Table\" style=\"border-collapse: collapse; border-style: none; width: 89.26%;\" align=\"center\" width=\"90%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\" colspan=\"2\"\u003e\n\u003ch4\u003e\u003cstrong\u003eReference Standards\u003c\/strong\u003e\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\" colspan=\"2\"\u003e\n\u003ch4\u003e\u003cstrong\u003eSTANDARDS THE OZONE TEST CHAMBER - OZONE TEST UV FOR TESTING RUBBER DETERIORATION COMPLIES WITH:\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eASTM D1149; ASTM D1171; ASTM D4575; ASTM D1056; ISO 12046; ISO 6916-1; ISO 6916-2; ISO 3011; ISO 1431-1; ISO 1431-3; ISO 7326; ISO 7840; FIAT 50417; EN 681-1; JIS K_6259; DIN 53_509-1; SAE J1401;   \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\" colspan=\"2\"\u003e\n\u003ch4\u003e\u003cstrong\u003eOzone Test Chamber – OzoneTest UV for testing Rubber Deterioration Characteristics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003ch4\u003e\u003cstrong\u003eTEST CHAMBER \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eCylindrical Stainless Steel test chamber with internal illumination and inspection window. Ø 550 mm; H 550 mm. Volume 155 Litres\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003ch4\u003e\u003cstrong\u003eCONTROL OF OZONE CONCENTRATION \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eAutomatic between 10 and 500 PPHM (50.5 to 505 mPa). UV Absorption Analyzer according to ISO 1431-3 and ASTM D4575 with ± 3% accuracy\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003ch4\u003e\u003cstrong\u003eTEMPERATURE CONTROL (STANDARD INSTRUMENT) \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eFrom Room Temperature +5°C to 70°C. Accuracy: 0.1°C. \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003ch4\u003e\u003cstrong\u003eAIRFLOW \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eAdjustable from 1 to 3 changes\/min (air change speed between 10 and 30 mm\/sec)\u003cbr\u003eInternal fan according to ISO 1431. \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\" colspan=\"2\"\u003e\n\u003ch4\u003e\u003cstrong\u003eOZONE CIRCUIT TYPE \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eClosed circuit with continuous ozone production and shooting down through self regenerating active carbon filter. \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\" colspan=\"2\"\u003e\n\u003ch4\u003e\u003cstrong\u003eSample holders\u003c\/strong\u003e\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSTATIC SAMPLE HOLDERS \u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eStatic strain and planetary displacement according to ISO 1431-1 standard (32 to 64 samples)\u003c\/li\u003e\n\u003cli\u003eTests on rubber hoses according to ISO 7326 \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSAMPLE HOLDER FOR DYNAMIC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTEST Frequency: 3 to 30 cicles\/min (0.05 to 0.5 Hz). Holder for 10 samples \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\" colspan=\"2\"\u003e\u003cstrong\u003eSoftware\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eRESULTS STORAGE \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe test result sand the curves are stored in the SQL database which is installed in combination with the software \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eTEST DATA PRODUCED \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eOzone concentration, temperature and Humidity level (only with Humidity control option) during test time \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eDATA PRINTOUT \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eTest identification data, test parameters, sample characteristics, curves of ozone concentration, temperature, relative humidity, notes about results, images uploaded during the test. \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003cp\u003e\u003cstrong\u003eSOFTWARE USAGE LANGUAGES \u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eItalian, English, French, Spanish, German, Portuguese, Russian, Chinese, Japanese, Turkish, Polish, Czech \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\" colspan=\"2\"\u003e\u003cstrong\u003eSafety Devices\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003ch4\u003e\u003cstrong\u003eSAFETY DEVICES \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eSafety Pushbutton.\u003cbr\u003eSafety Lock of the door of the instrument if ozone concentration is higher than 10 pphm.\u003cbr\u003eSafety thermostat for overheating \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003ch4\u003e\n\u003cstrong\u003eLABELLING\u003c\/strong\u003e \u003c\/h4\u003e\n\u003cp\u003eCE Labelling \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\" colspan=\"2\"\u003e\n\u003ch4\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003ch4\u003e\u003cstrong\u003eCALIBRATION REPORT \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eCalibration report with traceability to primary standards in conformity with the Calibration requirements specified in ISO 1431-1 standard \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003ch4\u003e\u003cstrong\u003eCALIBRATED PARAMETERS \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThe certificate includes the calibration of:\u003cbr\u003e- Temperature (40°C).\u003cbr\u003e- Ozone Concentration (at 50 pphm, 100 pphm, 150 pphm, 200 pphm)\u003cbr\u003e- Time for reaching ozone concentration set\u003cbr\u003e- Relative Humidity (at 50% and 75%) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\" colspan=\"2\"\u003e\n\u003ch4\u003e\u003cstrong\u003eConstruction Characteristics\u003c\/strong\u003e\u003c\/h4\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003ch4\u003e\u003cstrong\u003ePOWER SUPPLY \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003e220 VAC,50\/60 Hz, 2.5 kW, single phase, (110 VAC, 60 Hz on request) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003ch4\u003e\u003cstrong\u003eSAMPLE HOLDERS ELEVATOR \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eLifting gear for up and down movement to help in the inspection of the different sample holders \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003ch4\u003e\n\u003cstrong\u003eDIMENSIONS\u003c\/strong\u003e \u003c\/h4\u003e\n\u003cp\u003e(W x D x H) 1060 x 1000 x 1080 mm (2390 mm with lifting system) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\"\u003e\n\u003ch4\u003e\n\u003cstrong\u003eWEIGHT\u003c\/strong\u003e \u003c\/h4\u003e\n\u003cp\u003e370 Kg \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"border-color: black; border-width: 2px; height: 78px; padding: 0in 7px; width: 16%;\" colspan=\"2\"\u003e\n\u003ch4\u003e\u003cstrong\u003ePERSONAL COMPUTER (OPTIONAL) \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eMinimum Configuration: Intel Core i5 4 GB RAM.\u003cbr\u003eCompatible Operating Systems: Windows 10;\u003cbr\u003eConnection to the instrument via USB Cable (included) \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":53067308663095,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/ozone-test-chamber-ozonetest-uv.webp?v=1790703850","url":"https:\/\/qualitest.us\/pt\/products\/ozone-test-chamber-ozonetest-uv-for-testing-rubber-deterioration","provider":"Qualitest USA LC","version":"1.0","type":"link"}