{"product_id":"comparative-tracking-index-tester","title":"Comparative Tracking Index Tester","description":"\u003ch2\u003eComparative Tracking Index Tester – QualiFlame™ CTI\u003c\/h2\u003e\n\u003ch4\u003eComparative Tracking Index (CTI) and Proof Tracking Index (PTI) Test Apparatus\u003c\/h4\u003e\n\u003cp\u003eThe QualiFlame™ CTI evaluates the ability of solid electrical insulation materials to withstand surface tracking when\n    exposed to contaminated moisture under an applied electrical voltage. It establishes two important material\n    performance values: the Comparative Tracking Index (CTI) and the Proof Tracking Index (PTI). The instrument is\n    designed for testing environments across household appliance manufacturing, lighting equipment production,\n    electrical connector manufacturing, and material research laboratories.\u003c\/p\u003e\n\u003cp\u003eDuring testing, two platinum electrodes make contact with the specimen while controlled electrolyte drops are\n    delivered into the space between them. The entire procedure takes place inside a fully enclosed test cabinet,\n    isolating the operator from energized components. This arrangement supports controlled testing while keeping direct\n    access to high-voltage parts restricted.\u003c\/p\u003e\n\u003cp\u003eThe specimen is positioned on a glass plate within an illuminated test chamber. Once in place, the electrodes descend\n    onto its upper surface. A supplied gauge block establishes the required 4.0 mm separation between the electrodes,\n    while the adjustable specimen table provides precise control over electrode positioning and the height from which\n    electrolyte drops fall. Before starting, the operator configures the test voltage, current limit, dripping\n    frequency, and total drop count through the control panel. Closing the chamber door allows the PLC-controlled\n    sequence to proceed without requiring access to the testing area.\u003c\/p\u003e\n\u003cp\u003eThe instrument accommodates test voltages from 100 V to 1000 V, with voltage displayed as an r.m.s. value and current\n    measurement held within a 1.5% tolerance. Its PLC-based touch control system manages the test sequence, records drop\n    counts, and identifies operating faults. If tracking failure continues for at least two seconds, an audible alarm\n    identifies the test endpoint. This automatic notification eliminates the need for continuous observation of the\n    current meter. Flaming ignition remains a separate observation, as the test method distinguishes it from electrical\n    tracking failure.\u003c\/p\u003e\n\u003ch2\u003eComparative Tracking Index Tester – QualiFlame™ CTI Applications\u003c\/h2\u003e\n\u003cp\u003eThe QualiFlame™ CTI is used to investigate how electrical insulation materials perform when exposed to\n    moisture-related surface contamination and electrical stress. Its CTI and PTI measurements help manufacturers\n    determine whether insulating components can maintain adequate electrical separation in their intended operating\n    environments. The tester is particularly relevant to product development, material selection, quality assurance, and\n    certification activities across the following industries:\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eHousehold Appliance Manufacturing:\u003c\/strong\u003e Supports insulation material selection during the design and\n        qualification of household electrical products. Manufacturers can use CTI results to establish appropriate\n        creepage distances for terminal assemblies, internal control components, and appliance enclosures, helping\n        assess the risk of surface discharge between energized parts.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eLuminaire and Lighting Component Production:\u003c\/strong\u003e Helps lighting manufacturers evaluate insulation\n        materials used in lamp holders, LED driver housings, and structural electrical supports. Testing is particularly\n        relevant when these components must maintain electrical separation in environments where airborne dust and\n        moisture can contribute to surface contamination.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIT and Audio-Video Equipment:\u003c\/strong\u003e Assesses the ability of insulating components in power supplies,\n        adapters, and electronic equipment enclosures to resist conductive surface deterioration. The resulting\n        measurements provide material performance data for evaluating insulation suitability in compact electronic\n        assemblies.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eConnectors and Terminal Blocks:\u003c\/strong\u003e Provides a basis for comparing the tracking resistance of\n        molded insulating housings used to separate neighboring electrical terminals. This is especially important in\n        connector designs where limited spacing between energized conductors makes the insulating surface a critical\n        part of electrical protection.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eSwitchgear and Circuit Protection:\u003c\/strong\u003e Enables manufacturers to examine the resistance of molded\n        insulation and internal barrier materials used in circuit breakers, contactors, and distribution boards. CTI\n        results help determine whether these materials can withstand contamination-related electrical stress while\n        maintaining separation between conductive components.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eThermoset and Thermoplastic Compounding:\u003c\/strong\u003e Assists material developers in evaluating how\n        different resin formulations and filler combinations influence electrical tracking resistance. Comparative\n        testing makes it possible to rank material grades according to their performance and identify suitable\n        formulations during product development.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003ePrinted Circuit Board Laminates:\u003c\/strong\u003e Evaluates the tendency of insulating substrates to develop\n        conductive tracks under electrical stress, particularly in circuit board designs with closely spaced conductive\n        traces. The measurements help characterize the surface insulation properties of laminate materials.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eAutomotive and EV High-Voltage Components:\u003c\/strong\u003e Supports the qualification of insulating materials\n        used in battery packs, junction boxes, and charging assemblies. These components may encounter condensation\n        during operation, making resistance to moisture-assisted surface tracking an important material performance\n        consideration.\u003c\/li\u003e\n    \u003cli\u003e\n\u003cstrong\u003eCertification and Third-Party Laboratories:\u003c\/strong\u003e Provides standardized CTI and PTI measurements for\n        independent material evaluation and product qualification. Laboratories can use the test results to document\n        insulation performance in technical datasheets and support product approval submissions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStandards\u003c\/h2\u003e\n\u003cp\u003eThe QualiFlame™ CTI supports the determination of comparative and proof tracking indices in accordance with the\n    applicable test method and electrical product safety standards. These standards reference tracking resistance as\n    part of evaluating the suitability of solid insulating materials in different applications.\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n        \u003cp\u003eIEC 60112 – Method for the Determination of the Proof and the Comparative Tracking Indices of Solid\n            Insulating Materials\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003eIEC 60335-1 – Household and Similar Electrical Appliances, Safety, Part 1: General Requirements\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003eIEC 60598-1 – Luminaires, Part 1: General Requirements and Tests\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003eIEC 60950-1 – Information Technology Equipment, Safety, Part 1: General Requirements\u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eComparative Tracking Index Tester – QualiFlame™ CTI Key Features\u003c\/h2\u003e\n\u003cp\u003eThe QualiFlame™ CTI combines automated electrical testing with precision positioning and specimen handling\n    provisions. Each component contributes to consistent test conditions, controlled electrolyte delivery, and reliable\n    identification of tracking failure.\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eFully Enclosed Test Cabinet:\u003c\/strong\u003e Houses the energized testing assembly behind a closed door,\n            preventing direct operator exposure to the high-voltage electrodes while a test is underway.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003ePLC Control with Touch Interface:\u003c\/strong\u003e Coordinates voltage application, electrolyte drop\n            intervals, and drop counting through an automated testing sequence, reducing the need for manual operation.\n        \u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003e99% Minimum Purity Platinum Electrodes:\u003c\/strong\u003e Provide resistance to oxidation and material\n            erosion, reducing electrode-related variations that could affect results over repeated testing cycles.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eChisel-Edge Electrode Geometry:\u003c\/strong\u003e Features the specified 30° ±2° edge angle to establish\n            consistent electrode contact geometry across different specimens.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eSupplied Gauge Block:\u003c\/strong\u003e Provides a practical reference for setting the required 4.0 mm\n            distance between electrodes, allowing accurate and repeatable setup.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eAdjustable Table Height:\u003c\/strong\u003e Allows precise positioning of the specimen to establish the\n            required electrode angle and electrolyte drop height for each test arrangement.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eProgrammable Voltage and Limiting Current:\u003c\/strong\u003e Offers an adjustable voltage range of 100 V to\n            1000 V, supporting both PTI proof testing and complete CTI evaluations on one instrument.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eTwo-Second Tracking Failure Alarm:\u003c\/strong\u003e Automatically alerts the operator when the tracking\n            failure condition persists for two seconds or longer, eliminating the need for uninterrupted current meter\n            monitoring.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eDual Dripping Nozzle Sizes:\u003c\/strong\u003e Accommodates the different electrolyte drop volumes specified\n            for Solution A and Solution B testing.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eIlluminated Chamber:\u003c\/strong\u003e Provides visibility throughout the test, allowing observation of\n            scintillation, surface deterioration, and any flaming ignition.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eCalibrated 1.00 N Electrode Force:\u003c\/strong\u003e Applies the specified electrode contact force to\n            establish consistent testing pressure and support comparable results between laboratories.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eCustomizable Power Supply and Interface Language:\u003c\/strong\u003e Offers configuration options for local\n            electrical supply requirements and operator language preferences.\u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003eElectrical surface tracking develops through a sequence of localized deterioration rather than an immediate breakdown\n    of the insulation. The process begins when contaminated water forms a partially conductive path across the surface\n    between two energized points. As leakage current passes through this moisture film, localized heating causes water\n    to evaporate unevenly. The resulting dry regions, known as dry bands, interrupt the conductive film and concentrate\n    the applied voltage across the remaining gaps.\u003c\/p\u003e\n\u003cp\u003eElectrical discharges then develop across these dry bands, producing small surface arcs referred to as\n    scintillations. Repeated discharges subject the polymer surface to pyrolysis, leaving behind carbonized deposits.\n    Unlike the original insulating material, this carbon residue provides a more conductive path across the specimen.\n\u003c\/p\u003e\n\u003cp\u003eAs carbon deposits accumulate, the effective insulating distance between the electrodes becomes progressively\n    shorter. This allows further leakage current and arcing to develop, accelerating the deterioration process until the\n    material reaches its failure condition.\u003c\/p\u003e\n\u003cp\u003eThe CTI test reproduces this degradation mechanism under controlled laboratory conditions. Two platinum electrodes\n    with chisel-shaped edges are positioned 4.0 mm apart and apply a contact force of 1.00 N to the specimen.\n    Electrolyte drops are then delivered into the gap at predetermined intervals to create the conditions required for\n    tracking evaluation.\u003c\/p\u003e\n\u003cp\u003eTwo electrolyte formulations are available for the test. Solution A consists of a dilute ammonium chloride\n    electrolyte. Solution B contains an additional wetting agent that reduces surface tension, allowing the liquid to\n    spread more readily over hydrophobic insulating surfaces. This increased surface coverage creates more demanding\n    test conditions.\u003c\/p\u003e\n\u003cp\u003eA specimen reaches the failure endpoint when its leakage current exceeds the specified method threshold continuously\n    for at least two seconds or when ignition occurs. These conditions establish the basis for evaluating its tracking\n    resistance.\u003c\/p\u003e\n\u003cp\u003eThe Proof Tracking Index (PTI) identifies whether an insulating material can withstand 50 consecutive electrolyte\n    drops at a selected test voltage without reaching the failure condition. The Comparative Tracking Index (CTI), in\n    contrast, establishes the highest voltage at which the material successfully withstands the 50-drop test. This value\n    provides an important reference for determining the creepage distances permitted in electrical product design.\u003c\/p\u003e\n\u003cp\u003eElectrode material selection is also critical to test accuracy. Platinum is used because it resists oxidation and\n    minimizes the possibility of electrode-derived oxides contaminating the specimen surface. A more reactive electrode\n    material could introduce additional oxides into the developing track, potentially influencing the observed tracking\n    behavior and compromising the consistency of test results.\u003c\/p\u003e\n\u003ch2\u003eComparative Tracking Index Tester - QualiFlame™ CTI Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table table-style-align-center\" align=\"center\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"543\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth\u003eParameter\u003c\/th\u003e\n            \u003cth\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eModel\u003c\/td\u003e\n            \u003ctd\u003eQualiFlame™ CTI\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eController\u003c\/td\u003e\n            \u003ctd\u003ePLC with integrated touch interface\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eControl Language\u003c\/td\u003e\n            \u003ctd\u003eEnglish (other languages available on request)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eElectrode Material\u003c\/td\u003e\n            \u003ctd\u003ePlatinum, 99% minimum purity\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eElectrode Separation\u003c\/td\u003e\n            \u003ctd\u003e4.0 mm ±0.1 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eElectrode Angle\u003c\/td\u003e\n            \u003ctd\u003e60° ±5°\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eElectrode Width\u003c\/td\u003e\n            \u003ctd\u003e5 mm ±0.1 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eElectrode Thickness\u003c\/td\u003e\n            \u003ctd\u003e2 mm ±0.1 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eElectrode Length\u003c\/td\u003e\n            \u003ctd\u003e\u0026gt;12 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eElectrode End Chisel-Edge Angle\u003c\/td\u003e\n            \u003ctd\u003e30° ±2°, platinum\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eElectrode Pressure\u003c\/td\u003e\n            \u003ctd\u003e1.00 N ±0.05 N\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTest Voltage\u003c\/td\u003e\n            \u003ctd\u003e100 V to 1000 V, adjustable, r.m.s. display\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTest Current\u003c\/td\u003e\n            \u003ctd\u003er.m.s. display, tolerance 1.5%\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eDripping Nozzle, Solution A\u003c\/td\u003e\n            \u003ctd\u003e0.9 mm to 1.2 mm outer diameter\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eDripping Nozzle, Solution B\u003c\/td\u003e\n            \u003ctd\u003e0.9 mm to 3.45 mm outer diameter\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n            \u003ctd\u003e1100 × 740 × 1250 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eVoltage\u003c\/td\u003e\n            \u003ctd\u003e220 V, 50 Hz to 60 Hz, single phase, 800 W (110V is also available)\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":53636701880631,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/comparative-tracking-index-teste.webp?v=1794850647","url":"https:\/\/qualitest.us\/pt\/products\/comparative-tracking-index-tester","provider":"Qualitest USA LC","version":"1.0","type":"link"}