{"product_id":"basic-mobility-freeze-dryer","title":"Basic Mobility Freeze Dryer","description":"\u003ch2\u003eBasic Mobility Freeze Dryer – QualiFD™ M Series\u003c\/h2\u003e\n\u003cp\u003eThe QualiFD™ M Series Basic Mobility Freeze Dryer is a floor-standing Freeze Dryer Machine designed for flexible lab use and routine lyophilization. Built with integrated caster wheels, the system moves easily between benches, pilot areas, and shared laboratory spaces without interrupting established workflows. It supports consistent drying performance across applications in medicine, pharmaceuticals, biological research, chemistry, and food processing where controlled handling and repeatability are essential.\u003c\/p\u003e\n\u003cp\u003eThis mobility-focused freeze dryer features a compact, single-unit structure designed for space efficiency, reduced leakage risk, and straightforward operation. The cold trap and work surface are constructed from stainless steel, supporting corrosion resistance and simplified cleaning. Product-contact components are inert, aligning with GLP-oriented laboratory requirements.\u003c\/p\u003e\n\u003cp\u003eA wide cold trap opening combined with a pre-freeze function supports daily processing needs without reliance on a separate low-temperature freezer. The integrated touchscreen control system allows real-time monitoring and records key process curves for analysis, documentation, and reporting, helping maintain consistent and traceable results.\u003c\/p\u003e\n\u003ch2\u003eApplications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePharmaceutical and Medical Laboratories:\u003c\/strong\u003e\u003cbr\u003eFreeze drying supports extended storage of temperature-sensitive samples and intermediates while maintaining product integrity. The top-press configuration allows vials to be dried and sealed under vacuum for secure storage. Continuous monitoring of vacuum levels, cold trap temperature, and product temperature curves helps maintain process stability and supports consistent method development.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBiology and Microbiology Research:\u003c\/strong\u003e\u003cbr\u003eLyophilization is widely used for preserving enzymes, biological reagents, and other sensitive materials that degrade in liquid form. The ampoule-tube configuration is suitable for preserving microorganisms such as bacteria and fungi. A mobile base allows easy repositioning within shared lab environments, keeping the unit stable during operation while improving workflow flexibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChemistry and Specialty Materials:\u003c\/strong\u003e\u003cbr\u003eFreeze drying is applied to solutions, suspensions, and porous materials where low-temperature solvent removal is required. Manifold configurations allow connection of external bottles or vials and can integrate with concentration workflows when needed. Stainless steel construction supports routine cleaning and compatibility with commonly used laboratory solvents.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFood and Ingredient Development:\u003c\/strong\u003e\u003cbr\u003eIn food R\u0026amp;D, freeze drying is used for sensitive ingredients where heat-based drying may alter texture or aroma. The standard tray configuration supports small-batch processing of liquids, semi-solids, and solids for pilot-scale trials. Mobility enables teams to use the system across multiple applications without the need for a fixed installation space.\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eISO 13408-3:\u003c\/strong\u003e\u003cbr\u003eDefines requirements and guidance for lyophilization within aseptic processing of healthcare products. It focuses on maintaining sterility, controlled environments, and validated processes during freeze drying operations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eASTM E3250:\u003c\/strong\u003e\u003cbr\u003eCovers best practices for measuring product temperature and equipment pressure in pharmaceutical freeze drying. It outlines instrumentation approaches that support accurate data collection and reliable process control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61010-1:\u003c\/strong\u003e\u003cbr\u003eSpecifies safety requirements for electrical equipment used in measurement, control, and laboratory environments. It addresses protection against electrical hazards and supports safe operation of laboratory freeze drying systems.\u003c\/p\u003e\n\u003ch2\u003eBasic Mobility Freeze Dryer – QualiFD™ M Series Key Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMobility-focused floor design: Equipped with caster wheels for smooth relocation between different lab areas while maintaining stability during operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cstyle\u003e.customtable table{border-width:0px!important;}\n.customtable tr{border-width:0px!important;}\n.customtable td{border:none!important;text-align:left;vertical-align:middle;}\n\u003c\/style\u003e\n\u003ctable class=\"table customtable\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/freezer-dryer-5-1310713076.webp?v=1775049162\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eIntegrated one-piece design: Minimizes external connections and simplifies installation for faster setup.\u003c\/li\u003e\n\u003cli\u003eInert product-contact materials: Suitable for GLP-oriented laboratory workflows where material compatibility is important.\u003c\/li\u003e\n\u003cli\u003eStainless steel cold trap and workbench: Support corrosion resistance and allow quicker, more efficient cleaning.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eAll-stainless venting valve: Designed to minimize leakage risk while supporting safe and stable operation.\u003c\/li\u003e\n\u003cli\u003ePre-freeze capability: Paired with a large cold trap opening to simplify routine workflows and reduce preparation steps.\u003c\/li\u003e\n\u003cli\u003eGas flow control design: Helps maintain more uniform ice capture within the cold trap for consistent drying performance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/freezer-dryer-6-1419786545.webp?v=1775049163\" alt=\"\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/freezer-dryer-7-1866068740.webp?v=1775049162\" alt=\"\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003e7-inch embedded touchscreen: Displays real-time curves for cold trap temperature, sample temperature, and vacuum level, with data export options for review and printing.\u003c\/li\u003e\n\u003cli\u003eElectric defrost function: Helps reduce turnaround time between runs for improved workflow efficiency.\u003c\/li\u003e\n\u003cli\u003eProtection and alert system: Includes notifications for ambient temperature conditions, oil change intervals, sensor status, and compressor\/pump runtime to support safe and consistent operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003eFreeze drying removes solvent from a frozen product under reduced pressure. The process begins with freezing, followed by primary drying where ice transitions directly into vapor and is captured by the cold trap. Secondary drying then reduces bound moisture to achieve lower residual levels suitable for storage.\u003c\/p\u003e\n\u003cp\u003eCold trap temperature and chamber pressure play a key role in vapor capture efficiency and overall drying rate. Monitoring product temperature helps ensure the sample remains within formulation limits during primary drying. Once the cycle is complete, the chamber is brought back to atmospheric pressure before unloading and final sealing.\u003c\/p\u003e\n\u003ch2\u003eBasic Mobility Freeze Dryer – QualiFD™ M Series Technical Specification\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eModel configurations (QualiFD™ M Series)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/freezer-dryer-8-2069241530.webp?v=1775049220\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eQualiFD™ M1 (Standard): 4–6 stainless trays for bulk materials (liquid, paste, solid).\u003c\/li\u003e\n\u003cli\u003eQualiFD™ M2 (Top-Press): 3 trays with adjustable spacing; supports vial drying and vacuum stoppering after drying.\u003c\/li\u003e\n\u003cli\u003eQualiFD™ M3 (Standard + Multiple Manifolds): tray drying plus external hanging bottle attachment for vials or wide-mouth bottles; attachment can be removed during use.\u003c\/li\u003e\n\u003cli\u003eQualiFD™ M4 (Top-Press + Multiple Manifolds): combines top-press vial workflow with manifold capability.\u003c\/li\u003e\n\u003cli\u003eQualiFD™ M5 (Ampoule Tube): 24 ampoule interfaces for microorganism preservation workflows.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eTechnical parameters (full version, all models)\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003e\u003cspan style=\"font-weight: 400;\"\u003eSpecification\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan style=\"font-weight: 400;\"\u003eQualiFD™ M1\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan style=\"font-weight: 400;\"\u003eQualiFD™ M2\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan style=\"font-weight: 400;\"\u003eQualiFD™ M3\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan style=\"font-weight: 400;\"\u003eQualiFD™ M4\u003c\/span\u003e\u003c\/th\u003e\n\u003cth\u003e\u003cspan style=\"font-weight: 400;\"\u003eQualiFD™ M5\u003c\/span\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfiguration\u003c\/td\u003e\n\u003ctd\u003eStandard\u003c\/td\u003e\n\u003ctd\u003eTop-press\u003c\/td\u003e\n\u003ctd\u003eStandard + multiple manifolds\u003c\/td\u003e\n\u003ctd\u003eTop-press + multiple manifolds\u003c\/td\u003e\n\u003ctd\u003eAmpoule tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFreeze drying area\u003c\/td\u003e\n\u003ctd\u003e0.12 m²\u003c\/td\u003e\n\u003ctd\u003e0.08 m²\u003c\/td\u003e\n\u003ctd\u003e0.12 m²\u003c\/td\u003e\n\u003ctd\u003e0.08 m²\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCold trap temperature\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e≤ -60 °C; options ≤ -80 °C or ≤ -110 °C (no-load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltimate vacuum\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e\u0026lt; 5 Pa (no-load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater capture capacity\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e3–4 kg\/24 h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTray \/ shelves\u003c\/td\u003e\n\u003ctd\u003eØ200 mm, 4 layers (optional 6)\u003c\/td\u003e\n\u003ctd\u003eØ180 mm, 3 layers\u003c\/td\u003e\n\u003ctd\u003eØ200 mm, 4 layers (optional 6)\u003c\/td\u003e\n\u003ctd\u003eØ180 mm, 3 layers\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall power\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e970 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain unit weight\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W×D×H)\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003e580×500×720 mm + (430 drying chamber)\u003c\/td\u003e\n\u003ctd\u003e580×500×720 mm + (440)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoadable materials (10 mm thickness reference)\u003c\/td\u003e\n\u003ctd\u003e1.2 L\u003c\/td\u003e\n\u003ctd\u003e0.8 L\u003c\/td\u003e\n\u003ctd\u003e1.2 L\u003c\/td\u003e\n\u003ctd\u003e0.8 L\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVial capacity (tray reference)\u003c\/td\u003e\n\u003ctd\u003eΦ 12 mm: 492; Φ16 mm: 279; Φ22 mm: 147\u003c\/td\u003e\n\u003ctd\u003eΦ 12 mm: 492; Φ16 mm: 279; Φ22 mm: 147\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eAmpoule interfaces: 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":51847288488247,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/basic-mobility-freeze-dryer668151665.webp?v=1775049160","url":"https:\/\/qualitest.us\/pt\/products\/basic-mobility-freeze-dryer","provider":"Qualitest USA LC","version":"1.0","type":"link"}