{"product_id":"autovicat-367-en-astm-8-station-automatic-vicat-needle-apparatus-combo-en-astm-model","title":"AutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus (Combo EN-ASTM Model)","description":"\u003ch2\u003eAutoVicat-367-EN-ASTM – 8-Station Automatic Vicat Needle Apparatus\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-367-EN-ASTM is an advanced 8-Station Automatic Vicat Needle Apparatus designed for efficient and precise testing of construction materials. This EN-ASTM combination model supports testing procedures based on both European and ASTM standards, providing a versatile solution for cement and related material laboratories.\u003c\/p\u003e\n\u003cp\u003eFeaturing programmable test sequences and dedicated data recording software, the system streamlines Vicat testing while improving measurement consistency and laboratory productivity. Its multi-station configuration allows multiple samples to be tested efficiently, while the supplied accessories support complete testing workflows.\u003c\/p\u003e\n\u003cp\u003eWith automated operation, computerized data management, and compatibility with EN and ASTM Vicat testing requirements, the AutoVicat-367-EN-ASTM provides a reliable solution for quality control, research, and material testing applications.\u003c\/p\u003e\n\u003ch2\u003eAutoVicat-367-EN-ASTM – 8-Station Automatic Vicat Needle Apparatus\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus is designed for automated determination of initial and final setting times of cement and related construction materials. This EN-ASTM combination model supports testing according to EN 196-3, ASTM C191 Method B, and EN 480-2, with the required optional equipment.\u003c\/p\u003e\n\u003cp\u003eThe system features eight measuring points arranged in a rectangular trough, allowing multiple samples to be tested within a single setup. Testing can be performed in air or in a constant-temperature water bath. The water-bath configuration can include a heat exchanger and cooler to help maintain the required test temperature.\u003c\/p\u003e\n\u003cp\u003eFor EN-based testing, the apparatus supports programmable test sequences, helping streamline automated Vicat penetration measurements. For ASTM testing, samples can be tested in humid air conditions above 95% relative humidity, as required by the applicable procedure.\u003c\/p\u003e\n\u003cp\u003eDuring operation, the system automatically records the initial setting time, final setting time, and corresponding setting plots. The combined weight of the plunger and Vicat needle is 300 g with a tolerance of ±1 g. After every penetration, the Vicat needle is automatically cleaned, helping maintain consistent testing conditions throughout the sequence.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e8-station automatic Vicat testing system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports EN 196-3, ASTM C191 Method B, and EN 480-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomated measurement of initial and final setting times\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic recording of setting curves and test data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProgrammable testing sequences for EN procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting in air or constant-temperature water bath\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional heat exchanger and cooling system for temperature control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e300 g ±1 g combined plunger and needle weight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic cleaning of the Vicat needle after each penetration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRectangular trough with eight measuring positions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eImportant Note\u003c\/h3\u003e\n\u003cp\u003eA standard PC or laptop is required to operate the equipment and is not included with the apparatus.\u003c\/p\u003e\n\u003cp\u003eFor EN 480-2 testing, the following additional equipment is required:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAdditional weight: 1.0366.10\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlunger: 1.0366.12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional extra cooling unit: 1.0366.13, for maintaining a test temperature of 5°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTheory and Methodology\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus applies the standard Vicat penetration principle to evaluate how cement or gypsum paste develops resistance to penetration as setting progresses. By automating the penetration sequence and recording measurements digitally, the system helps reduce manual intervention and provides consistent monitoring of the material's transition from a workable paste toward a rigid structure.\u003c\/p\u003e\n\u003ch2\u003eStandard Vicat Penetration Theory\u003c\/h2\u003e\n\u003cp\u003eVicat testing determines setting behavior by measuring the penetration of a standardized needle or plunger into a prepared cement paste at controlled time intervals.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eInitial Setting Time: The point at which the penetration reaches the specified criterion for initial set, indicating that the paste is beginning to lose its plastic and workable characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFinal Setting Time: The point at which the penetration reaches the specified final-set criterion, indicating that the material has developed substantially greater structural rigidity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe applicable requirements of ASTM C191 Method B, EN 196-3, and EN 480-2 define important testing parameters, including specimen preparation, apparatus configuration, environmental conditions, and penetration components. The combined weight of the plunger and Vicat needle is 300 g with a tolerance of ±1 g, according to the applicable setup.\u003c\/p\u003e\n\u003ch2\u003eAutoVicat-367-EN-ASTM Method Execution\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-367-EN-ASTM automates the Vicat penetration process through programmed mechanical operation, electronic measurement, and computerized data recording. This approach provides a repeatable testing sequence while reducing the need for continuous manual observation.\u003c\/p\u003e\n\u003ch3\u003eMulti-Station Testing Capacity\u003c\/h3\u003e\n\u003cp\u003eThe system incorporates eight measuring points arranged in a rectangular trough, allowing multiple specimens to be evaluated within one testing setup. The apparatus automatically moves between measuring positions according to the programmed sequence, supporting efficient multi-sample testing.\u003c\/p\u003e\n\u003ch3\u003eAutomated Needle Penetration\u003c\/h3\u003e\n\u003cp\u003eThe apparatus controls the penetration process mechanically according to the programmed test sequence. Automated positioning and measurement help maintain consistent testing intervals and reduce variations associated with repeated manual operation.\u003c\/p\u003e\n\u003ch3\u003eAutomatic Needle Cleaning\u003c\/h3\u003e\n\u003cp\u003eAfter each penetration, the Vicat needle is automatically cleaned before the next measurement. This helps prevent residual cement paste from affecting subsequent penetration measurements and supports consistent test conditions throughout the sequence.\u003c\/p\u003e\n\u003ch3\u003eTemperature and Humidity Control\u003c\/h3\u003e\n\u003cp\u003eTesting can be performed in air or in a constant-temperature water bath, depending on the applicable procedure and configuration. The water-bath setup can include a heat exchanger and cooling unit for maintaining the required temperature. For ASTM testing, the required humid-air conditions above 95% relative humidity can be provided using the appropriate environmental setup.\u003c\/p\u003e\n\u003ch3\u003eDigital Depth and Setting-Time Recording\u003c\/h3\u003e\n\u003cp\u003eElectronic measurement and PC-based software allow the system to record penetration data throughout the test. The apparatus automatically determines and records initial setting time, final setting time, and setting plots, providing a digital representation of the material's setting progression for analysis and documentation.\u003c\/p\u003e\n\u003ch2\u003eAutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus (Combo EN-ASTM Model)Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e700 x 600 x 600 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e110 - 230 V \/ 50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScope of delivery\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThe Base unit is designed as a table model, including the control unit and standard software for programmable test sequences and data recording.\u003c\/li\u003e\n\u003cli\u003e8 Vicat molds (conical hard plastic rings) measuring 70\/80 mm in diameter and 40 mm in height (compliant with EN standards).\u003c\/li\u003e\n\u003cli\u003e8 Vicat molds (conical hard plastic rings) measuring 60\/70 mm in diameter and 40 mm in height (compliant with ASTM standards).\u003c\/li\u003e\n\u003cli\u003e8 glass base plates, each with a diameter of 120 mm.\u003c\/li\u003e\n\u003cli\u003e8 centerings for Vicat molds (conical hard plastic rings) measuring 70\/80 mm in diameter and 40 mm in height (EN compliant).\u003c\/li\u003e\n\u003cli\u003e8 centerings for Vicat molds (conical hard plastic rings) measuring 60\/70 mm in diameter and 40 mm in height (ASTM compliant).\u003c\/li\u003e\n\u003cli\u003e1 pair of cleaning brushes.\u003c\/li\u003e\n\u003cli\u003e1 tee wrench, size 1.25 mm.\u003c\/li\u003e\n\u003cli\u003e1 tee wrench, size 2 mm.\u003c\/li\u003e\n\u003cli\u003e2 spare glass plates, each with a diameter of 120 mm.\u003c\/li\u003e\n\u003cli\u003e2 spare initial-set needles, diameter 1.13 mm (EN).\u003c\/li\u003e\n\u003cli\u003e3 spare initial-set needles, diameter 1.0 mm (ASTM).\u003c\/li\u003e\n\u003cli\u003eCoarse filter sponge.\u003c\/li\u003e\n\u003cli\u003eFine filter sponge.\u003c\/li\u003e\n\u003cli\u003eSerial cable.\u003c\/li\u003e\n\u003cli\u003eFrame for the cover plate.\u003c\/li\u003e\n\u003cli\u003e8 cover plates for generating moist air (ASTM).\u003c\/li\u003e\n\u003cli\u003eHermetic stopper (ASTM).\u003c\/li\u003e\n\u003cli\u003eMud stop sponge (ASTM).\u003c\/li\u003e\n\u003cli\u003eDearerate set hose (ASTM).\u003c\/li\u003e\n\u003cli\u003eHumidity sensor cover (ASTM).\u003c\/li\u003e\n\u003cli\u003eUSB\/RS232 adapter.\u003c\/li\u003e\n\u003cli\u003eMains cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":53065213346103,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/autovicat-367-en-astm-8-station.webp?v=1790679742","url":"https:\/\/qualitest.us\/pt\/products\/autovicat-367-en-astm-8-station-automatic-vicat-needle-apparatus-combo-en-astm-model","provider":"Qualitest USA LC","version":"1.0","type":"link"}