{"product_id":"aas-atomic-absorption-spectrophotometer-qualiaas-3000f-flame-furnace-type","title":"AAS - Atomic Absorption Spectrophotometer QualiAAS™ 3000F (Flame Furnace Type)","description":"\u003ch2\u003eAAS - Atomic Absorption Spectrophotometer QualiAAS™ 3000F (Flame Furnace Type)\u003c\/h2\u003e\n\u003cp\u003eAAS – Atomic Absorption Spectrophotometer QualiAAS™ 3000F (Flame Furnace Type) is a high-precision analytical system designed for accurate metal analysis. It delivers strong selectivity, broad analytical applicability, high sensitivity, simple operation, cost-efficient performance, and reliable accuracy, making it suitable for demanding laboratory environments.\u003c\/p\u003e\n\u003cp\u003eThis instrument is widely applied in fields such as geology, mining, metallurgy, agriculture, forestry, hydrology, environmental monitoring, petrochemical processing, food and pharmaceutical safety, and third-party testing laboratories.\u003c\/p\u003e\n\u003cp\u003eThe flame system is built with high-stability flow control technology to ensure precise and automated gas regulation during operation. A durable gas-liquid separation unit, gas filtration system, and supporting components help maintain stable performance even in high humidity conditions or areas with limited gas supply.\u003c\/p\u003e\n\u003cp\u003eIntegrated safety interlocking mechanisms and intelligent alert functions provide automatic shutdown and alarm responses in case of operational irregularities, enhancing overall protection during use.\u003c\/p\u003e\n\u003cp\u003eIts modular design and well-structured circuit architecture allow convenient maintenance, enabling fast component replacement and efficient servicing without complex procedures.\u003c\/p\u003e\n\u003cp\u003eThe system also supports expandable analytical techniques such as the hydride generation method, flame emission technique, and high-temperature flame analysis. Additional accessories, including an automatic flame sampler, further enhance workflow efficiency and analytical flexibility.\u003c\/p\u003e\n\u003ch2\u003ePerformance Index\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWavelength Range: 170 nm – 900 nm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWavelength Accuracy: ≤ ±0.10 nm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWavelength Repeatability: ≤ 0.05 nm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBaseline Stability:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDrift ≤ 0.002 Abs, noise ≤ 0.001 Abs (stable 30 min)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDrift ≤ 0.002 Abs, noise ≤ 0.001 Abs (dynamic 15 min)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eResolution Performance: Spectral bandwidth deviation ≤ 0.02 nm; manganese double-line peak-to-valley ratio ≤ 25%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlame Method for Copper:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDetection limit ≤ 0.002 μg\/mL\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCharacteristic concentration ≤ 0.025 μg\/mL per 1%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrecision ≤ 0.3%\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eBackground Correction Capability:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDeuterium lamp method up to 1.0 Abs with background ≥ 90×\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSelf-absorption correction up to 2.0 Abs with background ≥ 90×\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLight Source System\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e8-Lamp Configuration: High-performance turret design with automatic rotation, switching, and optical alignment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSimultaneous Operation: Supports up to 8 lamps running together for preheating and improved analytical throughput\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMemory Function: Individual lamp parameters can be edited and stored without programming requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptical System\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMonochromator: Czerny-Turner optical layout with 277 mm focal length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDiffraction Grating: 1800 grooves\/mm with blaze wavelength at 250 nm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSpectral Bandwidth Control: Adjustable settings of 0.1 nm, 0.2 nm, 0.4 nm, 0.8 nm, and 1.6 nm with automatic switching\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetector: High-sensitivity photomultiplier tube with wide spectral response\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntelligent Automation: Automatic peak detection, scanning, energy calibration, slit adjustment, and wavelength optimization without manual reset\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFlame System\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBurner Head: 10 cm titanium burner optimized for air-acetylene flame, including emission mode support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSpray Chamber: PPS material construction offering corrosion resistance, heat tolerance, flame resistance, hydrophobic properties, and mechanical strength\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdjustable Burner Control: Flexible vertical and horizontal positioning with rotatable angle adjustment\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomated Ignition System: Mass flow-controlled fuel regulation with automatic ignition and shutdown functions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlame Data Interface: Real-time readable detection output via foot pedal operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSoftware Workstation\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eOne-Touch Operation: Simplified workflow for instrument optimization and multi-sample analysis\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRepeat Testing: 1–99 cycles with automatic calculation of mean, standard deviation, and RSD\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntelligent Processing: Automatic curve fitting, concentration calculation, re-slope adjustment, and standard addition method support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eReporting Tools: Data export and printing available in Word, Excel, and other formats\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSafety Protection System\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDual Safety Architecture: Combined hardware and software alarm system for enhanced operational safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFlame Safety Controls: Automatic gas shutoff, shutdown sequence, and alarm activation during abnormal pressure, ignition failure, leakage, or unstable flow conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIndependent Protection Modules: Emergency flame shutdown switch and high-current protection for furnace safety\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eOptional Functional Configurations\u003c\/h2\u003e\n\u003ch3\u003eFlame Automatic Sampler (Optional)\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIndependent sampling system designed for flame analysis without disturbing furnace setup\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQuick-release sample tray system for fast handling of standard and sample containers\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCapacity for 70-position trays with ≥20 mL per cup using universal consumables\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic positioning, alignment correction, and high-flow multi-stage cleaning system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eOxygen-Enriched High-Temperature Flame (Optional)\u003c\/h3\u003e\n\u003cp\u003eEnables high-temperature element analysis such as aluminum, barium, molybdenum, and vanadium while avoiding hazardous oxidizing gases\u003c\/p\u003e\n\u003ch3\u003eWide-Slit Combustion Head (Optional)\u003c\/h3\u003e\n\u003cp\u003eSupports complex sample stability with adjustable nebulizer for improved analytical consistency\u003c\/p\u003e\n\u003ch3\u003eHydride Generation System (Optional)\u003c\/h3\u003e\n\u003cp\u003eExtends analytical capability for additional elements using hydride vapor techniques\u003c\/p\u003e\n\u003ch3\u003eAudit Trail Software (Optional)\u003c\/h3\u003e\n\u003cp\u003eIncludes electronic signatures, user access control, and full process traceability for compliance with audit requirements\u003c\/p\u003e\n\u003ch2\u003eAAS - Atomic Absorption Spectrophotometer QualiAAS™ 3000F (Flame Furnace Type) Dimensions and Weight\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMain Unit: 1020mm×530mm×500mm(L×W×H), 85kg\u003c\/li\u003e\n\u003cli\u003eFlame automatic sampler: 440mm×290mm×440mm(L×W×H), 14kg.\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52008582545719,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/aas-atomic-absorption-spectrophotometer-qualiaas-3000f-flame-furnace-type583753286.webp?v=1776709497","url":"https:\/\/qualitest.us\/pt\/products\/aas-atomic-absorption-spectrophotometer-qualiaas-3000f-flame-furnace-type","provider":"Qualitest USA LC","version":"1.0","type":"link"}