{"title":"XRF Spectrometers and Metal Analyzers","description":"\u003cp class=\"ng-star-inserted\"\u003e\u003cspan class=\"ng-star-inserted\"\u003eThese testing systems utilize X-ray emissions to identify substance compositions without causing surface damage. By reading the secondary energy signatures released from specimens, the machinery swiftly verifies the constituents in alloys, precious metals, and mineral ores.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ng-star-inserted\"\u003e\u003cspan class=\"ng-star-inserted\"\u003eOrganizations choose between portable handheld options for on-site reviews and benchtop models for laboratory workflows. These adaptable configurations confirm ecological compliance while offering direct data readouts through straightforward touchscreen interfaces.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"qualix-su-ii-xrf-sulfur-in-oil-analyzer","title":"QualiX™ SU-II XRF Sulfur In Oil Analyzer","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThis \u003c\/span\u003e\u003cspan\u003eSulfur In Oil Analyzer\u003c\/span\u003e\u003cspan\u003e takes advantage of advanced high-energy radiation beam methods for detecting sulfur concentration metrics within liquid petrochemical substances. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe instrument aligns closely with global ecological protective standards to stop engine metallic erosion. Its compact structural configuration allows on-the-move operations within field testing trucks and laboratories.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eFeatures and Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eTrace Concentration Capabilities\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e Evaluates active elements stretching from low 1 ppm to a maximum 20% limit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eHelium-Free Vacuum Design\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e Runs an airtight testing chamber negative pressure zone without requiring expensive purge gases to lower everyday running costs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eInnovative Down-Lighting Configuration\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e Prevents substance vapor evaporation from contaminating X-ray source tube and beryllium access port during volatile petroleum testing procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eMobile-Ready Shell\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e: \u003c\/strong\u003eIntegrates a large-format tablet industrial processing terminal inside a compact lightweight under-thirty-kilo footprint for hassle-free field transport.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eAutomated Analysis Curves\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e Employs built-in algorithmic calculations for identifying correct calibration plots automatically, eliminating operator-induced database errors.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eGlobal Compliance Guarantee\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e: \u003c\/strong\u003eAligns with international ASTM and NB\/SH\/T 0842 testing parameters utilizing a premium-grade Silicon Drift Detector.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications of Sulfur In Oil Analyzer - QualiX™ SU-II\u003cbr\u003e\n\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalyzed Element\u003c\/td\u003e\n\u003ctd\u003eS, Cl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalysis Range\u003c\/td\u003e\n\u003ctd\u003e1ppm-20%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLimit of Detection\u003c\/td\u003e\n\u003ctd\u003e1ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunction\u003c\/td\u003e\n\u003ctd\u003eSpecial for petroleum element analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIntegrated PC\u003c\/td\u003e\n\u003ctd\u003e10\" industrial tablet PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalytical Precision\u003c\/td\u003e\n\u003ctd\u003e10ppm, the precision can be controlled to \u0026lt;10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Time\u003c\/td\u003e\n\u003ctd\u003e200-600S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasuring Object\u003c\/td\u003e\n\u003ctd\u003eLiquid, Solid, Powder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Voltage\u003c\/td\u003e\n\u003ctd\u003eAC110V\/220V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking Temperature\u003c\/td\u003e\n\u003ctd\u003e10-35°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension\u003c\/td\u003e\n\u003ctd\u003eL\/W\/H\u0026lt;400mm, Volume: 0.06m3 (can be mounted on vehicle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;30kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003e\n\u003cbr\u003eRepeatability Data\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"0\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eActual Content\/No.\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.0 ppm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e5.0 ppm\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e10.0 ppm\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003e5.2\u003c\/td\u003e\n\u003ctd\u003e9.8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e0.0\u003c\/td\u003e\n\u003ctd\u003e4.8\u003c\/td\u003e\n\u003ctd\u003e9.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e3\u003c\/td\u003e\n\u003ctd\u003e0.9\u003c\/td\u003e\n\u003ctd\u003e5.5\u003c\/td\u003e\n\u003ctd\u003e9.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4\u003c\/td\u003e\n\u003ctd\u003e0.0\u003c\/td\u003e\n\u003ctd\u003e4.6\u003c\/td\u003e\n\u003ctd\u003e9.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003ctd\u003e0.0\u003c\/td\u003e\n\u003ctd\u003e5.0\u003c\/td\u003e\n\u003ctd\u003e10.7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e6\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e4.5\u003c\/td\u003e\n\u003ctd\u003e9.9\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e0.0\u003c\/td\u003e\n\u003ctd\u003e5.6\u003c\/td\u003e\n\u003ctd\u003e10.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e8\u003c\/td\u003e\n\u003ctd\u003e0.0\u003c\/td\u003e\n\u003ctd\u003e5.4\u003c\/td\u003e\n\u003ctd\u003e10.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e9\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003ctd\u003e6.3\u003c\/td\u003e\n\u003ctd\u003e10.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e0.0\u003c\/td\u003e\n\u003ctd\u003e4.9\u003c\/td\u003e\n\u003ctd\u003e10.3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e11\u003c\/td\u003e\n\u003ctd\u003e0.0\u003c\/td\u003e\n\u003ctd\u003e6.1\u003c\/td\u003e\n\u003ctd\u003e10.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Deviation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.56\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.60\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cstrong\u003e0.52\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003eTesting results indicate that the stability of light oil is excellent and the results are precise\u003c\/p\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52487199129911,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/sulfur-oil-analyzer-qualix-su-ii498714395.webp?v=1781685313"},{"product_id":"qualiedx-600-gold-precious-metal-analyzer-and-edx-spectrometer","title":"QualiEDX™ 600 - Gold \u0026 Precious Metal Analyzer and EDX Spectrometer","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThis \u003c\/span\u003e\u003cspan\u003eGold \u0026amp; Precious Metal Analyzer and EDX Spectrometer\u003c\/span\u003e\u003cspan\u003e delivers an exceptionally consistent and trustworthy approach for thoroughly assessing alloy elemental makeup. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe hardware takes advantage of X-ray emission light responses to identify target metallic elements. This platform interprets complex spectral measurements to generate unwavering metrics without tedious calculations.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eFeatures and Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eExtensive Content Coverage\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e Measures compositional percentages stretching from minor 0.01% to an absolute 99.99% limit.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eCost-Effective Sensing Hardware\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e: \u003c\/strong\u003eUtilizes a standardized gas-filled counter detector for examining high-value geological and alloyed materials with stable reading replication.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eEnhanced Spectral Correction\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e: \u003c\/strong\u003eEmploys autonomous matrix compensation for reducing inter-element overlap distortions during complex specimen appraisals.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eWide-Range Element Identification\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e Identifies chemical signatures stretching from potassium to uranium elements to confirm metal presence.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eAdvanced Data Integration\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e: \u003c\/strong\u003eRuns curve-matching regression models for figuring out actual substance concentrations with optimal numeric processing steps.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eHandles Diverse Material Forms\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e Accommodates crushed powder structures, liquid-state alloys, or hard jewelry pieces.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eGold \u0026amp; Precious Metal Analyzer and EDX Spectrometer – QualiEDX™ 600 Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eElements\u003c\/td\u003e\n\u003ctd\u003eK-U\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Object\u003c\/td\u003e\n\u003ctd\u003eSolid, Liquid, Powder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalytical Content\u003c\/td\u003e\n\u003ctd\u003e0.01% - 99.99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Dimension\u003c\/td\u003e\n\u003ctd\u003e500 x 397 x 394 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Chamber Size\u003c\/td\u003e\n\u003ctd\u003e260 x 306 x 98 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e33 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52487220789559,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/gold-precious-metal-analyzer-and-edx-spectrometer-qualiedx600249734316_89293e21-ebff-4683-a118-59acdbb8e92e.jpg?v=1781685929"},{"product_id":"qualiedx-800-gold-precious-metal-analyzer-and-edx-spectrometer","title":"QualiEDX™800 - Gold \u0026 Precious Metal Analyzer and EDX Spectrometer","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThis \u003c\/span\u003e\u003cspan\u003eGold \u0026amp; Precious Metal Analyzer and EDX Spectrometer\u003c\/span\u003e\u003cspan\u003e delivers an exceptionally fluid and productive approach for verifying precious high-value alloy composition. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe hardware evaluates plating coating depth and content of hard-state ornaments. This system is highly useful for processing refinement centers to achieve ongoing operating reading consistency.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eFeatures and Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003ePrecious Metal Identification\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e: \u003c\/strong\u003eTests particular ratios of high-value elemental materials inside jewelry finished decorative items.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003ePlating Depth Measurement\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e Evaluates outer layer coating thicknesses in addition to base metal composition.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eLong-Term Reading Consistency\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e: \u003c\/strong\u003eSecures a functional performance stability variance of 0.1% when examining pure aurum contents exceeding 95%.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eHigh-Efficiency Detection Hardware\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e: \u003c\/strong\u003eUtilizes a standardized gas-filled counter working together with a Multi-Channel Analyzer for speedy pulse collection.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eCommercial Lab Versatility\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e Meets the analysis and inspection needs of decorative ornament processing plants, financial gold retail stores, and banking office locations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eHandles Hard Materials\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e:\u003c\/strong\u003e Evaluates hard-state sample blocks without requiring complex pre-treatment stages.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eGold \u0026amp; Precious Metal Analyzer and EDX Spectrometer – QualiEDX™ 800 Technical Specifications\u003c\/h2\u003e\n\u003ch3\u003eConfigurations:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eSingle sample chamber\u003c\/li\u003e\n\u003cli\u003eProportional counter\u003c\/li\u003e\n\u003cli\u003eMCA\u003c\/li\u003e\n\u003cli\u003eHigh Voltage Generator\u003c\/li\u003e\n\u003cli\u003eX-ray tube\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eRange of measurable elements:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eAu, Ag, Cu etc.\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eSample form:\u003cspan\u003e \u003c\/span\u003e\u003c\/strong\u003eSolid\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eLong-term operating stability:\u003c\/strong\u003e\u003cspan\u003e \u003c\/span\u003e0.1% (Au\u0026gt;95%)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52487239958839,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/gold-precious-metal-analyzer-and-edx-spectrometer-qualiedx800207375452.jpg?v=1781686230"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/collections\/gold-precious-metal-analyzer-and-edx-spectrometer-qualiedx600249734316.jpg?v=1781685012","url":"https:\/\/qualitest.us\/pt\/collections\/xrf-spectrometers-and-metal-analyzers.oembed","provider":"Qualitest USA LC","version":"1.0","type":"link"}