{"title":"Automatic Melt Flow Indexer (MFI) - QualiFi™ 6000 Series","description":"\u003ch2\u003eAutomatic Melt Flow Indexer (MFI) – QualiFi™ 6000 Series\u003c\/h2\u003e\n\u003cp\u003eThe QualiFi™ 6000 Series is a high-end extrusion plastometer range designed for modern quality control laboratories and high-throughput testing environments. It includes two models: the semi-automatic QualiFi™ 6000SA and the fully automatic QualiFi™ 6000A, both built as floor-standing systems to deliver highly accurate measurements of thermoplastic resin flow properties.\u003c\/p\u003e\n\u003cp\u003eThis Melt Flow Index Tester measures both melt mass-flow rate (MFR) and melt volume-flow rate (MVR) with strong consistency and repeatable results. It supports a wide temperature control range from 50°C to 450°C, making it suitable for testing standard polymers as well as high-temperature engineering materials.\u003c\/p\u003e\n\u003cp\u003eWith a measurement capacity ranging from 0.1 to 100 g\/10min for MFR and up to 3000 cm³\/10min for MVR, the QualiFi™ 6000 Series is engineered for precise polymer characterization. Integrated pneumatic control systems and advanced safety features streamline operation, reduce manual handling, and enhance testing efficiency while maintaining reliable Melt Flow Index results.\u003c\/p\u003e\n\u003ch2\u003eApplication\u003c\/h2\u003e\n\u003cp\u003eA highly automated Melt Flow Indexer is critical in laboratory and industrial environments where testing speed, safety, and high sample throughput are key operational requirements. The QualiFi™ 6000 Series is well-suited for a wide range of polymer testing applications, including:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Frequency Production Quality Control:\u003c\/strong\u003e\u003cbr\u003eEfficiently supports incoming and outgoing inspection of polyolefins and specialty resins. Pneumatic cleaning functionality helps reduce turnaround time between tests and improves workflow efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Plastics Evaluation:\u003c\/strong\u003e\u003cbr\u003eDelivers stable performance for high-viscosity and high-temperature materials such as nylon, polycarbonate, and fluoropolymers, ensuring consistent flow measurement under demanding conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePetrochemical \u0026amp; Compounding Operations:\u003c\/strong\u003e\u003cbr\u003eSupports continuous process monitoring of polymer melts directly from production streams, enabling quick sample transitions without the need for barrel disassembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlastics Manufacturing Quality Assurance:\u003c\/strong\u003e\u003cbr\u003eUsed for validating production batches and verifying supplier material consistency against defined MFR specifications in accordance with ISO 1133 and ASTM D1238 standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRegulated \u0026amp; Accredited Testing Laboratories:\u003c\/strong\u003e\u003cbr\u003eProvides traceable and reliable test data for certification and third-party analysis, supported by detailed data logging, user access control, and measurement accuracy verified under CNAS-aligned systems.\u003c\/p\u003e\n\u003ch2\u003eProduct Table Comparison\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003eQualiFi™ 6000SA\u003c\/th\u003e\n\u003cth\u003eQualiFi™ 6000A\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomation Level\u003c\/td\u003e\n\u003ctd\u003eSemi-automatic with pneumatic features\u003c\/td\u003e\n\u003ctd\u003eFully automatic with full pneumatic operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight Selection Mode\u003c\/td\u003e\n\u003ctd\u003eManual pre-selection\u003c\/td\u003e\n\u003ctd\u003eSoftware-controlled multi-weight selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreload \/ Weight System\u003c\/td\u003e\n\u003ctd\u003eElectric loading - weight preset manually, auto lifted\/lowered\u003c\/td\u003e\n\u003ctd\u003eElectric loading with programmable multi-stage variable load function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic Compaction \u0026amp; Extrusion\u003c\/td\u003e\n\u003ctd\u003eYes (10-50 kg adjustable load)\u003c\/td\u003e\n\u003ctd\u003eYes (10-50 kg adjustable load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic Barrel Cleaning\u003c\/td\u003e\n\u003ctd\u003eYes, compressed air assisted\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 s\u003c\/td\u003e\n\u003ctd\u003e0.0005 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Features\u003c\/td\u003e\n\u003ctd\u003eWeight fall-prevention guard\u003c\/td\u003e\n\u003ctd\u003eWeight safety guard \u0026amp; movable protective cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L×W×H)\u003c\/td\u003e\n\u003ctd\u003e580 × 480 × 1450 mm\u003c\/td\u003e\n\u003ctd\u003e600 × 500 × 1450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Unit Weight\u003c\/td\u003e\n\u003ctd\u003e100 kg\u003c\/td\u003e\n\u003ctd\u003e120 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhy Choose the QualiFi™ 6000 Series for Melt Flow Index Testing?\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Workflow Automation:\u003c\/strong\u003e\u003cbr\u003eIntegrated pneumatic force control (10–50 kg) manages material compaction and residual extrusion with high consistency. This removes variability linked to manual rod handling, improves repeatability for high-viscosity polymers, and reduces operator effort during routine testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImproved Operational Safety:\u003c\/strong\u003e\u003cbr\u003eDesigned as floor-standing instruments, both models include a dedicated weight fall-prevention guard that physically restricts uncontrolled weight descent during operation. A protective movable cover also helps isolate operators from high-temperature zones.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFully Automated Testing – QualiFi™ 6000A:\u003c\/strong\u003e\u003cbr\u003eThe QualiFi™ 6000A offers software-driven multi-weight selection, removing the need for manual weight handling. Users can configure multi-stage load sequences directly through the interface, supporting advanced and multi-step test protocols with ease.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh Thermal Stability Control:\u003c\/strong\u003e\u003cbr\u003eA dual PID temperature regulation system maintains tight thermal consistency with a gradient within ±0.1°C along the barrel above the die. Rapid thermal recovery—under 2 minutes after loading—helps maintain test efficiency and cycle speed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompliance and Measurement Traceability:\u003c\/strong\u003e\u003cbr\u003eThe QualiFi™ 6000 Series is CE certified (EN 61010-1, EN 61326-1) and has demonstrated strong performance in CNAS inter-laboratory proficiency testing, with Z-scores between -0.07 and +0.11. This ensures dependable results aligned with ISO 1133 and ASTM D1238 standards.\u003c\/p\u003e","products":[{"product_id":"automatic-melt-flow-indexer-mfi","title":"Automatic Melt Flow Indexer (MFI)","description":"\u003ch2\u003eAutomatic Melt Flow Indexer (MFI) — QualiFi™ 6000A\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFlagship Fully Automatic MFI System with Software-Controlled Variable Load and Pneumatic Operation\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe QualiFi™ 6000A is a high-performance automatic melt flow indexer designed for advanced laboratories and quality control facilities that require precise automation, strong measurement reliability, and enhanced operational safety in thermoplastic melt flow testing. It features a software-driven weight selection system with variable load capability, complete pneumatic control for sample compaction, residual material extrusion, and barrel cleaning, along with a 10.1-inch high-definition touchscreen interface.\u003c\/p\u003e\n\u003cp\u003eThis model delivers both Melt Mass Flow Rate (MFR) and Melt Volume Flow Rate (MVR) testing across a broad operating range of 50–450 °C, supporting flow measurements from 0.1–100 g\/10 min (MFR) and 0.01–3,000 cm³\/10 min (MVR). This extensive range represents the widest testing capability within the QualiFi™ melt flow indexer series.\u003c\/p\u003e\n\u003cp\u003ePositioned at the top of the QualiFi™ lineup, the 6000A stands apart from the 4000A and 5000A models through its software-controlled multi-weight selection system with variable load functionality, enabling fully programmable multi-stage load changes within a single test cycle. Automatic weight lifting and lowering, pneumatic sample handling and cleaning, a built-in safety guard for weight control, and a protective barrier between the furnace and loading system collectively reduce manual intervention and improve consistency throughout testing—from sample loading to final data export.\u003c\/p\u003e\n\u003cp\u003eThe QualiFi™ 6000A has been part of CNAS inter-laboratory proficiency testing programs for several consecutive years, consistently achieving Z-scores within the ±0.11 range. These results reflect highly stable measurement performance aligned with internationally recognized reference standards.\u003c\/p\u003e\n\u003ch2\u003eAutomatic Melt Flow Indexer (MFI) — QualiFi™ 6000A Applications\u003c\/h2\u003e\n\u003cp\u003eThe QualiFi™ 6000A melt flow indexer is designed for quality control, research and development, and incoming material inspection workflows in any laboratory or industrial setting where thermoplastic melt flow properties are a key specification or process control parameter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlastic Raw Material Production \u0026amp; Quality Control\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUsed for incoming raw material inspection, batch consistency checks, and production quality monitoring in polymer manufacturing environments. The software-driven variable load system and 8-group stored test program capability allow quick switching between test conditions for different resin grades without repeated manual setup. This supports efficient, high-throughput testing where melt flow index is a critical acceptance parameter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEngineering Plastics Testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSuitable for melt flow measurement of high-temperature engineering polymers such as polycarbonate (PC), polyamide (PA), fluoropolymers, and polyoxymethylene (POM), operating across a full 50–450 °C range. Independent multi-zone temperature control with ±0.1 °C stability ensures consistent thermal conditions required for accurate testing of advanced engineering materials.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePolyolefin \u0026amp; Commodity Polymer Testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eProvides reliable MFR and MVR measurement for polyethylene (PE), polypropylene (PP), polystyrene (PS), ABS, and similar thermoplastics under standard testing conditions. Automated weight handling and software-based load selection reduce manual steps and help maintain consistency in routine melt flow index testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePharmaceutical \u0026amp; Medical-Grade Polymer Testing\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eSupports melt flow evaluation of medical and pharmaceutical-grade polymers used in regulated applications. Built-in user access control, 5,000-test USB data storage, DMS data management software, and optional PC connectivity enable structured data handling and traceable documentation for compliance requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePetrochemical Industry \u0026amp; Refinery QC\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eUsed for verifying polymer consistency in petrochemical production and refinery environments where stable melt flow behavior is essential for downstream processing. The corrosion-resistant surface treatment and reinforced aluminum structure support long-term operation in demanding laboratory conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResearch Institutions \u0026amp; Universities\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIdeal for academic research, polymer development studies, and comparative melt flow analysis. The system supports both MVR-based and calculated MFR methods, enabling direct comparison between measurement approaches for advanced material characterization studies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCommodity Inspection \u0026amp; Certification Laboratories\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eApplied in third-party testing, certification, and regulatory compliance environments. Alignment with ISO 1133 and ASTM D1238 standards, combined with CNAS proficiency testing history and CE certification, ensures suitability for accredited laboratories requiring traceable and standardized melt flow measurements.\u003c\/p\u003e\n\u003ch2\u003eStandards Compliance\u003c\/h2\u003e\n\u003cp\u003eThe QualiFi™ 6000A melt flow indexer is engineered and manufactured in accordance with internationally recognized standards governing thermoplastic melt flow testing, laboratory instrument safety, and electromagnetic compatibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eISO 1133\u003c\/strong\u003e\u003cbr\u003ePlastics — Determination of melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics. This serves as the primary international standard defining test procedures, measurement principles, and performance expectations for melt flow index testing systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eASTM D1238\u003c\/strong\u003e\u003cbr\u003eStandard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer. This is the key North American reference standard for MFR and MVR determination and defines operational procedures for melt flow index instruments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEN 61010-1:2010+A1:2019\u003c\/strong\u003e\u003cbr\u003eSafety requirements for electrical equipment used in measurement, control, and laboratory environments. This standard supports CE compliance for electrical and operational safety in laboratory instruments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEN 61326-1:2013\u003c\/strong\u003e\u003cbr\u003eElectromagnetic compatibility requirements for measurement, control, and laboratory equipment. Ensures stable performance of the instrument in environments with electromagnetic interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCE Marking\u003c\/strong\u003e\u003cbr\u003eThe QualiFi™ 6000A carries CE marking, confirming compliance with applicable European Union directives for safety, health, and environmental protection requirements related to laboratory measurement and control equipment.\u003c\/p\u003e\n\u003ch2\u003eCertifications \u0026amp; Proficiency Verification\u003c\/h2\u003e\n\u003cp\u003eThe QualiFi™ 6000SA is built on the validated QualiFi™ Series platform and shares the same certification framework and performance verification standards applied across the product family, including CE compliance and CNAS inter-laboratory testing participation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCE Certification\u003c\/strong\u003e\u003cbr\u003eComplies with EN 61010-1:2010+A1:2019 (Low Voltage Directive) and EN 61326-1:2013 (Electromagnetic Compatibility). Conformity is verified through ECM Certificate of Compliance, confirming adherence to essential safety and EMC requirements for laboratory measurement equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCNAS Proficiency Testing\u003c\/strong\u003e\u003cbr\u003eParticipates in consecutive CNAS inter-laboratory proficiency testing programs with consistently satisfactory outcomes. Recorded Z-scores remain within −0.07 to +0.11 across all evaluation rounds, demonstrating stable measurement performance and strong inter-laboratory comparability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Patents\u003c\/strong\u003e\u003cbr\u003eThe QualiFi™ Series incorporates multiple registered patents covering key innovations in measurement technology, thermal control systems, and instrument design architecture, supporting enhanced testing precision and operational reliability.\u003c\/p\u003e\n\u003ch2\u003eAutomatic Melt Flow Indexer (MFI) — QualiFi™ 6000A Key Features\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/qualifitm-6000-1298853698.webp?v=1776682511\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch2\u003eInstrument Design \u0026amp; Construction\u003c\/h2\u003e\n\u003cp\u003eThe QualiFi™ 6000A is engineered with a focus on durability, operational safety, and efficient laboratory ergonomics, making it suitable for both intensive quality control and research environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAll-Aluminum Body with Advanced Surface Treatment\u003c\/strong\u003e\u003cbr\u003eThe instrument is built on a full aluminum structure with enhanced surface finishing technology, delivering strong mechanical durability and resistance to corrosion, including salt spray conditions. This construction supports stable performance in demanding laboratory and production quality control settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTrapezoidal Barrel Design with 15° Tilt\u003c\/strong\u003e\u003cbr\u003eAn innovative trapezoidal barrel layout combined with a 15° inclined body and upper rotating mechanism ensures a compact system footprint while improving workflow accessibility. This ergonomic design allows easier access for sample loading and operation, optimizing space efficiency in laboratory setups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Thermal Insulation System\u003c\/strong\u003e\u003cbr\u003eThe unit incorporates eco-conscious, molded thermal insulation integrated into the structure. This design improves heat retention within the furnace, stabilizes temperature conditions and contributes to reduced energy consumption during continuous operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMovable Protective Safety Cover\u003c\/strong\u003e\u003cbr\u003eA movable protective barrier positioned between the furnace and loading assembly enhances operational safety during weight handling and sample loading. This feature reduces exposure to high-temperature zones and supports safer, controlled test execution throughout the workflow.\u003c\/p\u003e\n\u003ch2\u003eSoftware-Controlled Variable Load System\u003c\/h2\u003e\n\u003cp\u003eThe QualiFi™ 6000A features an advanced software-driven load management system designed to deliver fully automated, highly repeatable melt flow testing with minimal operator involvement. This system is a core differentiator of the model within the QualiFi™ Series.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware-Controlled Multi-Weight Selection with Variable Load Function\u003c\/strong\u003e\u003cbr\u003eThe instrument uses a software-managed multi-weight selection system with variable load capability, allowing fully programmable load changes during a single test cycle. This eliminates dependence on preset manual configurations and supports more flexible, condition-specific testing workflows.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic Weight Handling System\u003c\/strong\u003e\u003cbr\u003eWeights are lifted and lowered automatically through a motorized control system, removing the need for manual weight handling. This reduces operator exposure to high-temperature components and helps eliminate load sequencing errors, improving overall test consistency and repeatability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntegrated Weight Safety Guard\u003c\/strong\u003e\u003cbr\u003eA built-in weight safety guard is included as standard to prevent unintended weight drop events during automatic load transitions. This enhances operational safety and ensures stable load control throughout the testing process.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDual Preloading Modes\u003c\/strong\u003e\u003cbr\u003eThe system supports two preloading configurations for flexible testing setup:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCalibration Weight Load: 0.325–21.6 kg range for standard calibration procedures\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdditional Load: 10–50 kg adjustable range for extended test conditions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese adjustable settings enable precise reproduction of test conditions across different materials and standards, supporting consistent and traceable measurement results.\u003c\/p\u003e\n\u003ch2\u003ePneumatic Automation System\u003c\/h2\u003e\n\u003cp\u003eThe QualiFi™ 6000A integrates a fully pneumatic control system to ensure consistent specimen preparation, efficient workflow transitions, and improved operational safety across melt flow testing procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Compaction with Adjustable Load Control\u003c\/strong\u003e\u003cbr\u003ePneumatic compaction operates with adjustable force settings (10–50 kg) and configurable compaction time, ensuring uniform specimen packing. This removes operator-dependent variability and supports consistent sample preparation conditions across repeated tests.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Residual Material Extrusion\u003c\/strong\u003e\u003cbr\u003eAn automated pneumatic extrusion function applies adjustable load (10–50 kg) to efficiently purge residual material from the barrel after testing. This enables rapid transition between samples while maintaining repeatable cleaning performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Barrel Cleaning System\u003c\/strong\u003e\u003cbr\u003eThe system includes pneumatic-assisted barrel cleaning to standardize inter-test preparation. This eliminates manual brushing, reduces contamination risk, and ensures consistent cleaning efficiency between consecutive tests.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAir Supply Requirement\u003c\/strong\u003e\u003cbr\u003eThe system operates with a compressed air requirement of \u0026gt;0.6 MPa, ensuring stable pneumatic performance for compaction, extrusion, and cleaning functions throughout the testing cycle.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eTemperature Control\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/qualifitm-6000sa-2-868307007.webp?v=1776682510\" alt=\"\"\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eFull operating range of 50–450 °C, enabling testing from commodity plastics to high-temperature engineering polymers on a single melt flow index tester platform.\u003cbr\u003eMulti-stage independent temperature control with dynamic heat distribution ensures a temperature gradient within ≤±0.1 °C along the barrel above the die.\u003c\/li\u003e\n\u003cli\u003eTemperature indication error is ≤0.2 °C, with temperature fluctuation maintained within ≤±0.2 °C, and a fine temperature resolution of 0.01 °C for precise control.\u003c\/li\u003e\n\u003cli\u003eTemperature recovery after specimen loading is ≤2 minutes, helping reduce overall cycle time in high-throughput melt flow index testing workflows.\u003c\/li\u003e\n\u003cli\u003eAn intelligent dual PID control algorithm ensures fast heating response, stable temperature rise, and consistent thermal recovery throughout operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMeasurement Performance\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/qualifitm-6000sa-1-1322974009.webp?v=1776682509\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMFR measurement range: 0.1–100 g\/10 min; MVR measurement range: 0.01–3,000 cm³\/10 min — one of the widest measurement ranges available in the melt flow indexer category, enabling accurate testing across very low to very high flow thermoplastics.\u003c\/li\u003e\n\u003cli\u003ePiston displacement indication error: ±0.02 mm; displacement resolution: 0.002 mm, ensuring highly precise piston movement tracking during measurement cycles.\u003c\/li\u003e\n\u003cli\u003eTimer resolution: 0.0005 seconds — the finest timing resolution in the QualiFi™ melt flow indexer series, supporting highly accurate flow rate calculations.\u003c\/li\u003e\n\u003cli\u003eDie plug device based on a lever principle, extending the measurable range up to 3,000 cm³\/10 min while preventing barrel leakage during high-flow testing conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eControl Software \u0026amp; Data Management\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMenu-guided 10.1-inch full HD color touchscreen interface with real-time temperature–time curve and MVR curve visualization, providing clear monitoring of testing conditions and flow behavior during operation.\u003c\/li\u003e\n\u003cli\u003eMass method, Volume Method A, and Volume Method B testing are fully supported, with automatic ISO\/ASTM effective interval identification and automatic test start for standardized workflow execution.\u003c\/li\u003e\n\u003cli\u003e8 stored test plan groups enable fast setup across multiple materials and specifications, improving efficiency in multi-material quality control environments.\u003c\/li\u003e\n\u003cli\u003eThe volume method automatically calculates MFR values from the input specimen mass, allowing direct comparison with mass method results for consistent data validation.\u003c\/li\u003e\n\u003cli\u003e5,000-group USB flash storage capacity and integrated DMS data management software support data export, analysis, and structured report generation. Optional PC software enables two-way control between PC and touchscreen, with direct upload to external databases and information systems.\u003c\/li\u003e\n\u003cli\u003eMulti-language interface support includes English, French, German, Italian, Russian, and additional languages for broader usability in global laboratories.\u003c\/li\u003e\n\u003cli\u003eA user authority management system with role-based access control protects measurement data and helps prevent operational errors.\u003c\/li\u003e\n\u003cli\u003eOptional CNAS-validated inter-laboratory proficiency testing records demonstrate performance consistency, with Z-scores maintained within ±0.11 across evaluations.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAccessories \u0026amp; Safety\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAdjustable metal observation mirror with 15° free-angle adjustment, explosion-proof and shatter-resistant design, and switchable viewing angles for clear monitoring of sample extrusion during testing.\u003c\/li\u003e\n\u003cli\u003eCutting segment collection box prevents fragment contamination of cut-off samples, helping maintain test integrity and result accuracy.\u003c\/li\u003e\n\u003cli\u003eStacking accessory support provides organized placement and easy access to all standard accessories during operation, improving workflow efficiency.\u003c\/li\u003e\n\u003cli\u003eStandard accessory set includes: barrel, piston rod, guide bush, weight tray and cover, Φ2.095 mm die, barrel cleaning rod, feeding rod, die cleaning rod, cutter, funnel, special tweezers, USB flash drive, wrenches, power cable, and PC software.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eExtrusion Plastometry — MFR and MVR Determination\u003c\/strong\u003e\u003cbr\u003eThe QualiFi™ 6000A operates based on the extrusion plastometry principle defined in ISO 1133 and ASTM D1238. A thermoplastic resin sample is introduced into a heated cylindrical barrel and brought to a controlled test temperature under defined preheating conditions. A specified dead-weight load is then applied through a piston, forcing the molten polymer through a precision-engineered die at the base of the barrel.\u003c\/p\u003e\n\u003cp\u003eThe melt flow indexer determines either the mass of extrudate collected over set time intervals (Mass Method, Method A: MFR expressed in g\/10 min) or piston displacement over time intervals (Volume Method, Method B: MVR expressed in cm³\/10 min), enabling evaluation of flow resistance under standardized conditions.\u003c\/p\u003e\n\u003cp\u003eThe melt flow index is inversely related to polymer viscosity under test conditions. Higher MFR or MVR values indicate lower melt viscosity and easier flow, while lower values reflect higher viscosity and greater flow resistance. This makes melt flow index a key parameter for quality control, batch consistency evaluation, molecular weight distribution screening, and process verification across thermoplastic materials.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSoftware-Controlled Variable Load System\u003c\/strong\u003e\u003cbr\u003eA defining feature of the QualiFi™ 6000A within the QualiFi™ melt flow indexer range is its software-driven weight selection system with variable load functionality. Instead of manual weight selection or fixed configurations, test loads are fully programmed through software. The system automatically selects, lifts, and lowers required weights, including multi-stage load variation within a single test cycle, without manual intervention. This removes errors related to incorrect weight selection, handling contamination, and load sequencing inconsistencies in multi-step testing protocols.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Stage Independent Temperature Control with Dual PID Algorithm\u003c\/strong\u003e\u003cbr\u003eTemperature control is managed by a high-performance heating and sensing system designed for continuous operation across 50–450 °C. Multi-stage independent control ensures dynamic heat distribution along the barrel, maintaining a temperature gradient of ≤±0.1 °C above the die.\u003c\/p\u003e\n\u003cp\u003eTemperature indication error is ≤0.2 °C, with fluctuation maintained within ≤±0.2 °C. The dual PID control algorithm enables rapid heating response and stable recovery, achieving temperature stabilization within less than 2 minutes after sample loading, significantly improving overall test cycle efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Precision Displacement Measurement\u003c\/strong\u003e\u003cbr\u003ePiston displacement used in MVR calculations is measured using a high-precision system with an indication error of ±0.02 mm and a resolution of 0.002 mm. The timer resolution of 0.0005 seconds enables highly accurate measurement of short interval cut-off sequences, supporting high-flow materials and extended measurement ranges up to 3,000 cm³\/10 min.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Operation — Compaction, Residual Extrusion, and Barrel Cleaning\u003c\/strong\u003e\u003cbr\u003eThe system integrates pneumatic automation across three key stages of the workflow.\u003cbr\u003ePneumatic compaction applies adjustable force and time (10–50 kg) to ensure uniform specimen packing, eliminating variability associated with manual compaction.\u003cbr\u003ePneumatic residual extrusion uses adjustable load (10–50 kg) to rapidly purge remaining material from the barrel after testing, improving turnaround efficiency.\u003cbr\u003ePneumatic barrel cleaning enables fast, consistent cleaning without manual intervention, reducing contamination risk and improving repeatability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePreloading and Preheating Modes\u003c\/strong\u003e\u003cbr\u003eThe QualiFi™ 6000A supports two preloading modes: calibration weight load (0.325–21.6 kg) and additional load (10–50 kg), both adjustable for accurate reproduction of test conditions across different materials. Two preheating modes (no-load and loaded) provide flexibility for various polymer types and testing protocols, supporting diverse laboratory requirements on a single platform.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement and Control Software\u003c\/strong\u003e\u003cbr\u003eThe onboard software supports Mass Method (Method A), Volume Method A, and Volume Method B testing in full compliance with ISO 1133 and ASTM D1238 standards. It automatically identifies effective test intervals and initiates measurements at the correct piston position without operator input, ensuring standardized operation.\u003c\/p\u003e\n\u003cp\u003eEight stored test plan groups allow pre-configuration of complete test parameters for different materials, reducing setup time and improving efficiency in multi-material testing environments. Real-time temperature–time curves and MVR flow curves displayed on the 10.1-inch touchscreen enable continuous monitoring of thermal stability and test repeatability throughout operation.\u003c\/p\u003e\n\u003ch2\u003eAutomatic Melt Flow Indexer (MFI) — QualiFi™ 6000A Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eQualiFi™ 6000A\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Methods\u003c\/td\u003e\n\u003ctd\u003eMFR (Mass Method) \/ MVR (Volume Method A \u0026amp; B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMFR Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0.1–100 g\/10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMVR Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0.01–3,000 cm³\/10 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eFull-color 10.1-inch HD touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCutting Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Resolution (s)\u003c\/td\u003e\n\u003ctd\u003e0.0005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Control Range (°C)\u003c\/td\u003e\n\u003ctd\u003e50–450 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution (°C)\u003c\/td\u003e\n\u003ctd\u003e0.01 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Indication Error\u003c\/td\u003e\n\u003ctd\u003e≤0.2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Fluctuation\u003c\/td\u003e\n\u003ctd\u003e≤±0.2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Gradient above Die (0–75 mm)\u003c\/td\u003e\n\u003ctd\u003e≤±0.3 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Recovery Time after Loading\u003c\/td\u003e\n\u003ctd\u003e≤2 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoading Mode\u003c\/td\u003e\n\u003ctd\u003eElectric (automatic weight lifting\/lowering)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight Selection System\u003c\/td\u003e\n\u003ctd\u003eSoftware-controlled; multi-weight set with variable load function\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreload Range — Calibration Weight Mode (kg)\u003c\/td\u003e\n\u003ctd\u003e0.325–21.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreload Range — Additional Load Mode (kg)\u003c\/td\u003e\n\u003ctd\u003e10–50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompaction Load Range (kg)\u003c\/td\u003e\n\u003ctd\u003e10–50 kg — pneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResidual Material Extrusion Load Range (kg)\u003c\/td\u003e\n\u003ctd\u003e10–50 kg — pneumatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiston Displacement Indication Error (mm)\u003c\/td\u003e\n\u003ctd\u003e±0.02 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiston Displacement Display Resolution (mm)\u003c\/td\u003e\n\u003ctd\u003e0.002 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e220V AC (-15% to +10%), 50 Hz, 0.5 kVA (110V is also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Source Requirement\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;0.6 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions W×D×H (mm)\u003c\/td\u003e\n\u003ctd\u003e600×500×1,450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight (kg)\u003c\/td\u003e\n\u003ctd\u003e120 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003e5,000 test groups (USB flash drive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware\u003c\/td\u003e\n\u003ctd\u003eDMS data management software; optional PC two-way control software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Languages\u003c\/td\u003e\n\u003ctd\u003eEnglish, French, German, Italian, Russian, and others\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE (EN 61010-1, EN 61326-1); CNAS inter-laboratory proficiency testing — satisfactory\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStandard Accessory Configuration\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eQuantity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain unit (including 1 barrel)\u003c\/td\u003e\n\u003ctd\u003e1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic weight set (piston rod, guide bush, weight tray, weight cover)\u003c\/td\u003e\n\u003ctd\u003e1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDie Φ2.095 mm\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarrel cleaning rod\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeeding rod\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDie cleaning rod\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic cutter\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunnel\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLevel\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecial tweezers\u003c\/td\u003e\n\u003ctd\u003e2 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003ctd\u003e2 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHexagon wrench (2 mm)\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixed wrench (8–10 mm)\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB flash drive\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower cable\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC software\u003c\/td\u003e\n\u003ctd\u003e1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOptional Accessories\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Forming Machine\u003c\/td\u003e\n\u003ctd\u003eCompression pre-forming device for powder, flake, film fragment, or granule specimens prior to MFR\/MVR testing — particularly useful for materials that cannot be loaded directly into the melt flow indexer barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52007813349687,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/automatic-melt-flow-indexer-mfi1680854696.webp?v=1776682512"},{"product_id":"semi-automatic-melt-flow-indexer-mfi","title":"Semi Automatic Melt Flow Indexer (MFI)","description":"\u003ch2\u003eSemi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA\u003c\/h2\u003e\n\u003cp\u003eQualiFi™ 6000SA is a semi-automatic, safety-enhanced melt flow indexer developed for B2B plastics testing laboratories that require higher throughput, reduced operator involvement, and improved safety compared to a standard automatic weight-loading instrument. It measures MFR across 0.1–100 g\/10 min and MVR up to 3000 cm³\/10 min at temperatures from 50 to 450 °C. This melt flow index tester integrates pneumatic material compaction, pneumatic residual extrusion, pneumatic barrel cleaning, and a weight fall-prevention guard within the QualiFi™ Series platform—delivering a safer, faster, and more repeatable testing workflow than the QualiFi™ 5000. CE certified and CNAS proficiency-verified, the QualiFi™ 6000SA is a reliable upgrade melt flow index tester for high-frequency QC and production monitoring environments across North America.\u003c\/p\u003e\n\u003cp\u003eThe QualiFi™ 6000SA is a pneumatic-assisted semi-automatic melt flow indexer designed for plastics testing environments where test throughput, operator safety, and measurement repeatability are higher priorities than compact benchtop design. Built on the QualiFi™ Series platform, it retains the core measurement precision, dual PID temperature control, and software capabilities of the QualiFi™ 5000 while adding pneumatic-assisted functions and a weight fall-prevention guard that reduce manual intervention, minimize human error, and improve operator safety during frequent testing cycles.\u003c\/p\u003e\n\u003cp\u003eThe weight is manually selected by the operator but automatically lifted and lowered without physical handling once selected, similar to the QualiFi™ 5000 lifting mechanism. A weight fall-prevention guard is added in the 6000SA, physically securing the weight stack and reducing the risk of uncontrolled weight movement during operation. Material compaction is performed pneumatically with adjustable force and time (10–50 kg), removing variability from manual compaction and improving repeatability for high-viscosity materials.\u003c\/p\u003e\n\u003cp\u003ePneumatic residual material extrusion uses adjustable pneumatic load (10–50 kg) to remove remaining polymer from the barrel after each test, reducing between-test cleaning time and effort. Pneumatic barrel cleaning completes the post-test cycle using compressed air to clear internal residue, eliminating the need for manual rod cleaning typically required on standard melt flow index testers. These three pneumatic functions reduce total turnaround time between tests, making the QualiFi™ 6000SA suitable for high-frequency QC environments where multiple tests are performed per shift.\u003c\/p\u003e\n\u003cp\u003eAll core QualiFi™ Series platform features are retained, including the 10.1-inch HD touch screen, 50–450 °C dual PID temperature control, ±0.2 °C temperature accuracy, 0.002 mm piston displacement resolution, 8 customizable test plans, 5,000-group USB data storage with DMS software, optional PC two-way control, and multi-language interface support. The floor-standing design (580×480×1450 mm) accommodates the pneumatic assembly and weight guard system and requires a compressed air supply above 0.6 MPa.\u003c\/p\u003e\n\u003ch2\u003eSemi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA Applications\u003c\/h2\u003e\n\u003cp\u003eThe QualiFi™ 6000SA melt flow indexer is designed for B2B plastics testing environments where test frequency, operational safety, and throughput are key requirements, and where variations from manual compaction in a standard melt flow index tester can impact result consistency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Frequency Production QC:\u003c\/strong\u003e\u003cbr\u003eIncoming and outgoing inspection of polyolefin, engineering plastic, and specialty resin batches at high testing volumes. Pneumatic cleaning and residual extrusion reduce between-test downtime and improve workflow efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Viscosity Polymer Testing:\u003c\/strong\u003e\u003cbr\u003eMFR\/MVR evaluation of materials such as nylon, polycarbonate, fluoroplastics, and other engineering resins requiring stable and repeatable compaction force. Pneumatic compaction eliminates operator-dependent variation associated with manual loading.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePetrochemical \u0026amp; Compounding Lines:\u003c\/strong\u003e\u003cbr\u003eProcess control and product validation of polymer melts and compound formulations that require consistent test conditions and fast changeover between samples without dismantling the barrel assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlastics Manufacturing Operations:\u003c\/strong\u003e\u003cbr\u003eBatch qualification, supplier verification, and extrusion or injection molding process monitoring based on defined MFR limits in accordance with ISO 1133 and ASTM D1238 standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRegulated \u0026amp; Accredited Laboratories:\u003c\/strong\u003e\u003cbr\u003eThird-party testing, certification, and inspection workflows requiring traceable data export, user access control, and CNAS-verified measurement consistency across repeated test cycles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAcademic \u0026amp; Applied Research:\u003c\/strong\u003e\u003cbr\u003ePolymer behavior analysis, blend formulation studies, and comparative melt flow testing across material grades with detailed data logging and reproducible test conditions.\u003c\/p\u003e\n\u003ch2\u003eStandards\u003c\/h2\u003e\n\u003cp\u003eThe QualiFi™ 6000SA melt flow indexer is designed and verified in accordance with internationally recognized standards for thermoplastic melt flow rate testing, laboratory measurement accuracy, and equipment safety.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eISO 1133-1:2011 — Plastics: Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics — Part 1: Standard procedure\u003c\/li\u003e\n\u003cli\u003eISO 1133-2:2011 — Plastics: Determination of MFR and MVR of thermoplastics — Part 2: Method for materials sensitive to time-temperature history and\/or moisture\u003c\/li\u003e\n\u003cli\u003eASTM D1238 — Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer (Procedures A and B)\u003c\/li\u003e\n\u003cli\u003eIEC 61010-1 \/ EN 61010-1:2010+A1:2019 — Safety requirements for electrical equipment used in measurement, control, and laboratory applications (CE certified)\u003c\/li\u003e\n\u003cli\u003eEN 61326-1:2013 — Electrical equipment for measurement, control, and laboratory use: EMC requirements (CE certified)\u003c\/li\u003e\n\u003cli\u003eISO 9001:2015 — Quality management system standard applied to laboratory instrument manufacturing processes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCertifications and Proficiency Verification\u003c\/h2\u003e\n\u003cp\u003eThe QualiFi™ 6000SA is built on the validated QualiFi™ Series platform and maintains the same core compliance framework across the product family, including CE certification and repeated CNAS proficiency testing validation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCE Certification:\u003c\/strong\u003e\u003cbr\u003eComplies with EN 61010-1:2010+A1:2019 (Low Voltage Directive) and EN 61326-1:2013 (EMC requirements), confirmed through ECM Certificate of Compliance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCNAS Proficiency Testing:\u003c\/strong\u003e\u003cbr\u003eVerified through consecutive CNAS inter-laboratory proficiency comparisons, with all results within acceptable limits. Reported Z-scores remain in the range of −0.07 to +0.11 across all evaluation rounds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Patents:\u003c\/strong\u003e\u003cbr\u003eThe QualiFi™ Series includes multiple registered technical patents covering core measurement systems, thermal control architecture, and structural design innovations.\u003c\/p\u003e\n\u003ch2\u003eSemi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA Key Features\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/qualifitm-6000-1298853698_1.webp?v=1776683421\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch3\u003ePneumatic Systems and Safety Step-up from QualiFi™ 5000\u003c\/h3\u003e\n\u003cp\u003eThe QualiFi™ 6000SA integrates enhanced pneumatic systems over the QualiFi™ 5000, improving consistency, efficiency, and operator safety in melt flow index testing workflows.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Material Compaction (10–50 kg adjustable):\u003c\/strong\u003e\u003cbr\u003eProvides controlled compaction force and timing, eliminating operator-dependent variation during sample preparation and improving run-to-run MFR\/MVR repeatability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Residual Material Extrusion (10–50 kg adjustable):\u003c\/strong\u003e\u003cbr\u003eUses controlled pneumatic load to remove remaining polymer from the barrel after testing, reducing reliance on manual rod operation and accelerating post-test processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Barrel Cleaning:\u003c\/strong\u003e\u003cbr\u003eApplies compressed air to clear residual material from the barrel interior, significantly reducing between-test preparation time and improving efficiency in high-frequency testing environments.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/qualifitm-6000sa-2-868307007_1.webp?v=1776683419\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight Fall-Prevention Guard:\u003c\/strong\u003e\u003cbr\u003eA mechanical safety system that physically secures the weight stack, preventing uncontrolled descent during setup, weight changes, or loading operations. This adds an extra layer of operational safety compared to the QualiFi™ 5000.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePreloading System (Dual Mode):\u003c\/strong\u003e\u003cbr\u003eSupports two controlled loading ranges to ensure accurate and repeatable test conditions across different materials:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCalibration weight load: 0.325–21.6 kg\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdditional load: 10–50 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth modes allow adjustable positioning to support precise reproduction of test parameters for varied material types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePreheating Function:\u003c\/strong\u003e\u003cbr\u003eSupports both no-load and loaded preheating operation modes, enabling flexible preparation protocols based on material characteristics and specific testing requirements.\u003c\/p\u003e\n\u003ch3\u003eCore Measurement Platform\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/qualifitm-6000sa-1-1322974009_1.webp?v=1776683418\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eCore components including the oven, die, and piston are manufactured from low-thermal-expansion, corrosion-resistant alloy materials that comply with ISO 1133 dimensional stability and hardness requirements, ensuring long-term measurement accuracy under high-temperature conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Control System:\u003c\/strong\u003e\u003cbr\u003eOperating range: 50–450 °C\u003cbr\u003eTemperature resolution: 0.01 °C\u003cbr\u003eMaximum indication error: ≤0.2 °C\u003cbr\u003eFluctuation: ≤±0.2 °C\u003cbr\u003eTemperature gradient: ≤±0.1 °C\u003c\/p\u003e\n\u003cp\u003eThe system uses dual PID temperature control for rapid, overshoot-free heating and stable regulation. After material loading, temperature recovery time is typically ≤2 minutes, supporting continuous high-frequency testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Precision System:\u003c\/strong\u003e\u003cbr\u003ePiston displacement resolution: 0.002 mm\u003cbr\u003eMaximum indication error: ±0.02 mm\u003cbr\u003eTimer resolution: 0.001 s\u003c\/p\u003e\n\u003cp\u003eThese parameters support high-accuracy MFR\/MVR determination with stable time and displacement tracking during extrusion testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Flow Measurement Capability:\u003c\/strong\u003e\u003cbr\u003eMaximum measurable flow rate reaches up to 3000 cm³\/10 min, extended through a lever-operated die plug device for broader material applicability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight Handling and Automation:\u003c\/strong\u003e\u003cbr\u003eThe system enables automatic lifting and lowering of weights without manual handling during operation. Weight selection is performed manually prior to test initiation, supporting controlled and repeatable loading conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUser Interface and Observation System:\u003c\/strong\u003e\u003cbr\u003eA 10.1-inch HD full-color touchscreen is integrated at the front of the oven for direct control and monitoring. A variable-angle metal observation mirror with 15° adjustable viewing and a shatter-resistant surface allows safe visual inspection during operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Structure:\u003c\/strong\u003e\u003cbr\u003eA movable protective cover shields the area between the furnace body and loading mechanism during high-temperature operation, improving operator safety and reducing exposure to heated components.\u003c\/p\u003e\n\u003ch3\u003eSoftware and Data Management\u003c\/h3\u003e\n\u003cp\u003eThe system supports Mass Method (A), Volume Method A, and Volume Method B testing, with automatic identification of ISO\/ASTM test intervals and automated test initiation to streamline workflow execution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Configuration:\u003c\/strong\u003e\u003cbr\u003eProvides 8 customizable test plans for direct selection before testing, reducing repetitive parameter setup in routine laboratory operations and improving workflow efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Monitoring:\u003c\/strong\u003e\u003cbr\u003eDisplays temperature–time and MVR–number curves in real time on the screen, enabling immediate evaluation of thermal stability and result consistency during testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Storage and Reporting:\u003c\/strong\u003e\u003cbr\u003eUSB flash drive storage supports up to 5,000 test result groups. Integrated DMS data management software enables data export and structured report generation for laboratory documentation and traceability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePC Integration and Connectivity:\u003c\/strong\u003e\u003cbr\u003eOptional PC software allows two-way system control and remote database upload, supporting centralized data management in multi-instrument environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Language Interface:\u003c\/strong\u003e\u003cbr\u003eSupports English, French, German, Italian, Russian, and Chinese for flexible international laboratory use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUser Access Control:\u003c\/strong\u003e\u003cbr\u003eIncludes user authority management with configurable role-based permissions to safeguard measurement data integrity and prevent unauthorized parameter modifications in shared laboratory settings.\u003c\/p\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMelt Flow Rate Measurement Principle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe QualiFi™ 6000SA operates based on the extrusion plastometer principle defined in ISO 1133 and ASTM D1238. A thermoplastic resin sample is introduced into a heated barrel and stabilized at the specified test temperature. A piston applies a defined load, forcing the molten polymer through a standard die (Φ2.095 mm) located at the base of the barrel.\u003c\/p\u003e\n\u003cp\u003eMFR (mass method, Procedure A) is determined by measuring the mass of extrudate collected at timed intervals. MVR (volume methods A and B) is calculated from piston displacement over a defined time period. The QualiFi™ 6000SA automates weight lifting, timing control, cutting, and result calculation, while also integrating pneumatic compaction, pneumatic residual extrusion, and pneumatic barrel cleaning. These additions reduce the number of manual operations per test cycle compared to the QualiFi™ 5000.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Compaction System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaterial compaction, the process of pressing the loaded polymer charge into the barrel prior to testing, is performed pneumatically on the QualiFi™ 6000SA with adjustable load and time (10–50 kg). In conventional melt flow index testers, this step is carried out manually using a feeding rod, which can introduce variation in applied force and compaction duration.\u003c\/p\u003e\n\u003cp\u003eThe pneumatic system provides a consistent and repeatable compaction force across all test cycles, independent of operator technique. This improves run-to-run repeatability of MFR\/MVR results, particularly for high-viscosity polymers and powder materials where pre-test density uniformity is critical.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Residual Extrusion and Barrel Cleaning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAfter each test cycle, remaining polymer in the barrel must be removed before the next sample is introduced. The QualiFi™ 6000SA performs this in two pneumatic stages:\u003c\/p\u003e\n\u003cp\u003eFirst, pneumatic residual extrusion applies an adjustable load (10–50 kg) to expel remaining polymer from the barrel and die, replacing manual push-rod operation used in conventional systems.\u003c\/p\u003e\n\u003cp\u003eSecond, pneumatic barrel cleaning uses compressed air to remove residual material from the internal barrel surface.\u003c\/p\u003e\n\u003cp\u003eTogether, these steps significantly reduce post-test turnaround time, minimize operator effort, and reduce exposure to high-temperature components, strengthening the safety-oriented design of the 6000SA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight Fall-Prevention Guard\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn floor-standing melt flow indexers, the weight stack is positioned at an elevated height, creating a potential risk of uncontrolled descent during setup, weight adjustment, or mechanical irregularities.\u003c\/p\u003e\n\u003cp\u003eThe QualiFi™ 6000SA incorporates a dedicated weight fall-prevention guard that physically restricts the weight stack movement and prevents uncontrolled descent events. This hardware safety mechanism is not included in the QualiFi™ 5000 and is specifically designed for the taller floor-standing structure of the 6000SA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDual PID Temperature Control and High-Precision Displacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe QualiFi™ 6000SA retains the same core temperature control and measurement architecture as the QualiFi™ 5000 platform. A high-temperature heating system and sensor assembly rated for continuous operation from 50 to 450 °C is controlled by a dual PID temperature regulation system.\u003c\/p\u003e\n\u003cp\u003eThis ensures rapid, overshoot-free heating, stable multi-zone thermal distribution with a temperature gradient of less than ±0.1 °C, and recovery to stable conditions within 2 minutes after sample loading.\u003c\/p\u003e\n\u003cp\u003ePiston displacement is measured with a resolution of 0.002 mm and a maximum indication error of ±0.02 mm. Timer resolution is 0.001 s, supporting precise MVR calculation across a measurement range of 0.01 to 3000 cm³\/10 min.\u003c\/p\u003e\n\u003ch2\u003eSemi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eQualiFi™ 6000SA\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003eMFR (mass method) \/ MVR (volume method A \u0026amp; B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMFR Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0.1–100 g\/10min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMVR Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0.01–3000 cm³\/10min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Mode\u003c\/td\u003e\n\u003ctd\u003eFull-color touch screen (10.1-inch HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCutting Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic cutting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Control Range\u003c\/td\u003e\n\u003ctd\u003e50–450 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Indication Error\u003c\/td\u003e\n\u003ctd\u003e≤ 0.2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Fluctuation\u003c\/td\u003e\n\u003ctd\u003e≤ ±0.2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Gradient (0–75 mm above die)\u003c\/td\u003e\n\u003ctd\u003e≤ ±0.3 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Recovery Time (after loading)\u003c\/td\u003e\n\u003ctd\u003e≤ 2 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoading Mode\u003c\/td\u003e\n\u003ctd\u003eElectric loading — weight preset manually, auto lifted\/lowered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight Selection Mode\u003c\/td\u003e\n\u003ctd\u003eManual pre-selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreloading Range\u003c\/td\u003e\n\u003ctd\u003eCalibration weight: 0.325–21.6 kg; Additional load: 10–50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic Compaction Load\u003c\/td\u003e\n\u003ctd\u003e10–50 kg (adjustable), pneumatic operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic Residual Extrusion Load\u003c\/td\u003e\n\u003ctd\u003e10–50 kg (adjustable), pneumatic operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic Barrel Cleaning\u003c\/td\u003e\n\u003ctd\u003eYes — compressed air assisted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight Fall-Prevention Guard\u003c\/td\u003e\n\u003ctd\u003eYes — hardware fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiston Displacement Indication Error\u003c\/td\u003e\n\u003ctd\u003e± 0.02 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiston Displacement Resolution\u003c\/td\u003e\n\u003ctd\u003e0.002 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Die Diameter\u003c\/td\u003e\n\u003ctd\u003eΦ2.095 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage Capacity\u003c\/td\u003e\n\u003ctd\u003e5,000 groups (USB flash drive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Plans\u003c\/td\u003e\n\u003ctd\u003e8 configurable and saveable test plans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Source Requirement\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 0.6 MPa (required for pneumatic functions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e220V (-15% \/ +10%) VAC, 50Hz, 0.5 kVA (110V is also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions L×W×H\u003c\/td\u003e\n\u003ctd\u003e580 × 480 × 1450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Unit Weight\u003c\/td\u003e\n\u003ctd\u003e100 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE (EN 61010-1:2010+A1:2019; EN 61326-1:2013); CNAS proficiency verified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Languages\u003c\/td\u003e\n\u003ctd\u003eEnglish, French, German, Italian, Russian, Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStandard Configuration\u003c\/h3\u003e\n\u003cp\u003eEach QualiFi™ 6000SA ships with all accessories required for immediate MFR and MVR testing per ISO 1133 and ASTM D1238, plus PC software. Note that a compressed air supply of more than 0.6 MPa is required for the pneumatic functions.\u003c\/p\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eQuantity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain unit (including 1 barrel)\u003c\/td\u003e\n\u003ctd\u003e1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic weight set (piston rod, guide bush, weight tray, weight cover)\u003c\/td\u003e\n\u003ctd\u003e1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard die Φ2.095 mm\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLevel\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarrel cleaning rod\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeeding rod\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDie cleaning rod\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCutter\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunnel\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003ctd\u003e2 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecial tweezers\u003c\/td\u003e\n\u003ctd\u003e2 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHexagon wrench (2 mm)\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB flash drive\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixed wrench (8–10)\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower cable\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC software (DMS data management)\u003c\/td\u003e\n\u003ctd\u003e1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOptional Accessories\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Forming Machine\u003c\/td\u003e\n\u003ctd\u003eCompression pre-forming device for powder, flake, film fragment, or granule specimens prior to MFR\/MVR testing — particularly useful for materials that cannot be loaded directly into the melt flow indexer barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52007856832823,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/semi-automatic-melt-flow-indexer-mfi653437803.webp?v=1776683406"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/collections\/automatic-melt-flow-indexer-mfi-qualifitm-6000-series918682672.webp?v=1776681143","url":"https:\/\/qualitest.us\/pt\/collections\/automatic-melt-flow-indexer-mfi-qualifi-6000-series.oembed","provider":"Qualitest USA LC","version":"1.0","type":"link"}