{"product_id":"rde-oes-standard-elemental-analyzer","title":"RDE-OES Standard Elemental Analyzer","description":"\u003ch2\u003eRDE-OES Standard Elemental Analyzer – QualiRDE™ 800\u003c\/h2\u003e\n\u003cp\u003eThe QualiRDE™ 800 RDE-OES Standard Elemental Analyzer delivers rapid elemental screening for in-service oils and related industrial fluids. It is built for laboratories and maintenance teams that require fast identification of wear metals, contaminants, and additive elements without time-consuming sample preparation. Using rotating disc electrode optical emission spectrometry, the system provides multi-element results in under 30 seconds, supporting quicker decisions in maintenance planning and fluid condition assessment.\u003c\/p\u003e\n\u003cp\u003eDesigned for demanding analytical environments, this RDE-OES platform supports routine oil analysis across power generation, transportation, aerospace, defense, and heavy equipment maintenance sectors. It features a 500 mm focal length optical system, holographic diffraction grating, high-speed data acquisition, and user-friendly software that ensures consistent performance in busy laboratory workflows.\u003c\/p\u003e\n\u003cp\u003eThe QualiRDE™ 800 is a compact solution for fast detection of metallic wear debris, contamination, and additive chemistry in used lubricants, hydraulic fluids, and selected fuel samples. It is well suited for predictive maintenance programs, condition monitoring, incoming fluid verification, and troubleshooting applications where speed and multi-element detection are critical.\u003c\/p\u003e\n\u003cp\u003eThis system enables direct oil analysis without dilution, chemical reagents, or auxiliary gases. Its advanced optical design supports wide spectral coverage, while the integrated software manages calibration, data processing, statistical evaluation, and reporting. The result is a reliable RDE-OES solution for organizations focused on monitoring equipment health and tracking fluid degradation trends with efficiency and accuracy.\u003c\/p\u003e\n\u003ch2\u003eRDE-OES Standard Elemental Analyzer – QualiRDE™ 800 Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eUsed Lubricating Oil Analysis:\u003c\/strong\u003e The QualiRDE™ 800 is designed for elemental evaluation of in-service lubricating oils to identify abnormal wear, contamination, and additive depletion. It helps maintenance teams monitor equipment condition, recognize early wear trends, and support preventive and predictive maintenance strategies.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHydraulic Fluid Monitoring:\u003c\/strong\u003e Hydraulic systems benefit from rapid detection of metallic particles and contaminants that may signal component wear or fluid breakdown. Routine RDE-OES analysis supports early identification of issues in pumps, valves, and hydraulic circuits, improving maintenance response time.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eFuel Contamination Screening:\u003c\/strong\u003e In applicable diesel and gas turbine fuel workflows, the system supports elemental screening for contamination aligned with ASTM D6728-type requirements. This helps detect corrosive elements and metallic impurities that can impact fuel quality and equipment reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eAerospace, Defense, Power, and Transportation Programs:\u003c\/strong\u003e This analyzer is widely used across aerospace, defense, power generation, and transportation sectors. These industries rely on fluid analysis to assess the condition of engines, turbines, gear systems, and hydraulic components operating under continuous load.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Volume Maintenance Laboratories:\u003c\/strong\u003e With analysis times under 30 seconds and no sample preparation required, the system is well suited for laboratories handling large sample volumes. The fast workflow improves turnaround time and supports consistent trend analysis across extensive equipment fleets.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eASTM D6595\u003c\/strong\u003e – Standard test method for determining wear metals and contaminants in used lubricating oils or used hydraulic fluids using rotating disc electrode atomic emission spectrometry. This method is widely applied for condition monitoring and wear trend analysis in in-service lubricants and hydraulic systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eASTM D6728\u003c\/strong\u003e – Standard test method for detecting contaminants in gas turbine and diesel engine fuels using rotating disc electrode atomic emission spectrometry. It is used to identify elemental contamination that may affect fuel quality, combustion efficiency, and equipment reliability.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eRDE-OES Standard Elemental Analyzer - QualiRDE™ 800 Key Features\u003c\/h2\u003e\n\u003cp\u003e\u003cimg width=\"400\" alt=\"RDE-OES Standard Elemental Analyzer\" src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/rde-oes-2-1022417255.webp?v=1782388932\"\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli data-end=\"216\" data-start=\"41\" data-section-id=\"c6nucx\"\u003e\n\u003cstrong data-end=\"76\" data-start=\"43\"\u003eRapid multi-element analysis:\u003c\/strong\u003e Delivers full elemental results in under 30 seconds, making it well suited for routine screening and high-throughput maintenance workflows.\u003cspan class=\"PDq2pG_selectionAnchor\" aria-hidden=\"true\"\u003e\u003c\/span\u003e\n\u003c\/li\u003e\n\u003cli data-end=\"421\" data-start=\"218\" data-section-id=\"yx072d\"\u003e\n\u003cstrong data-end=\"267\" data-start=\"220\"\u003eDirect sample testing without pretreatment:\u003c\/strong\u003e Oil samples can be analyzed directly without dilution, solvents, reagent gases, or chemical additives, reducing handling steps and simplifying operation.\u003c\/li\u003e\n\u003cli data-end=\"626\" data-start=\"423\" data-section-id=\"1akjqic\"\u003e\n\u003cstrong data-end=\"460\" data-start=\"425\"\u003eHigh-resolution optical design:\u003c\/strong\u003e Equipped with a holographic diffraction grating (2700 lines\/mm) and a 500 mm focal length optical system to ensure strong spectral resolution and analytical clarity.\u003c\/li\u003e\n\u003cli data-end=\"797\" data-start=\"628\" data-section-id=\"1mdp8u4\"\u003e\n\u003cstrong data-end=\"655\" data-start=\"630\"\u003eLow detection limits:\u003c\/strong\u003e Capable of detecting elements at sub-ppm levels, enabling trace-level monitoring for wear, contamination, and lubricant condition assessment.\u003c\/li\u003e\n\u003cli data-end=\"1001\" data-start=\"799\" data-section-id=\"tksp8b\"\u003e\n\u003cstrong data-end=\"829\" data-start=\"801\"\u003eBroad spectral coverage:\u003c\/strong\u003e Operates across an approximate 190–800 nm or 200–800 nm wavelength range (depending on configuration\/source), enabling multi-element detection across a wide spectral band.\u003c\/li\u003e\n\u003cli data-end=\"1218\" data-start=\"1003\" data-section-id=\"1ppyaam\"\u003e\n\u003cstrong data-end=\"1046\" data-start=\"1005\"\u003eFast digital acquisition and control:\u003c\/strong\u003e Uses microprocessor-controlled multi-channel integration, high-speed analog-to-digital conversion, and USB-based data transfer for efficient processing and system control.\u003c\/li\u003e\n\u003cli data-end=\"1435\" data-start=\"1220\" data-section-id=\"1topuk3\"\u003e\n\u003cstrong data-end=\"1261\" data-start=\"1222\"\u003eUser-friendly software environment:\u003c\/strong\u003e Includes intuitive graphical operation, method creation and editing, flexible output formats, automatic standardization, statistical tools, and out-of-range result flagging.\u003c\/li\u003e\n\u003cli data-end=\"1638\" data-start=\"1437\" data-section-id=\"2cvoil\"\u003e\n\u003cstrong data-end=\"1472\" data-start=\"1439\"\u003eExpanded reporting functions:\u003c\/strong\u003e Supports reporting of individual and averaged excitation results (up to 100 excitations), along with standard deviation and relative standard deviation calculations.\u003c\/li\u003e\n\u003cli data-end=\"1805\" data-start=\"1640\" data-section-id=\"9b60hb\"\u003e\n\u003cstrong data-end=\"1679\" data-start=\"1642\"\u003eSimple operation and maintenance:\u003c\/strong\u003e Designed for ease of use and straightforward maintenance, making it suitable for technicians with varying levels of training.\u003c\/li\u003e\n\u003cli data-end=\"1965\" data-start=\"1807\" data-section-id=\"17do316\"\u003e\n\u003cstrong data-end=\"1841\" data-start=\"1809\"\u003eStable continuous operation:\u003c\/strong\u003e Engineered for reliable long-duration use, supporting continuous laboratory workflows and high-demand testing environments.\u003c\/li\u003e\n\u003cli data-is-last-node=\"\" data-end=\"2187\" data-start=\"1967\" data-section-id=\"1tzwb4i\"\u003e\n\u003cstrong data-end=\"2018\" data-start=\"1969\"\u003eWear, contamination, and additive monitoring:\u003c\/strong\u003e Enables measurement of wear metals, contamination levels, and additive elements to support comprehensive fluid condition assessment and predictive maintenance programs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003eRDE-OES (rotating disc electrode optical emission spectrometry) is an analytical technique used to determine metallic elements in oils and fuels by exciting the sample and measuring the characteristic light emitted by each element. It is widely applied for rapid multi-element detection of wear metals, contaminants, and additive elements in in-service fluids.\u003c\/p\u003e\n\u003cp\u003eDuring analysis, a rotating graphite disc introduces a thin film of the sample into the excitation zone. As the sample is energized, it emits light at specific wavelengths corresponding to individual elements. The spectrometer detects these wavelengths and converts them into concentration values, enabling fast screening with minimal sample preparation. This makes the method well suited for routine maintenance and condition monitoring applications.\u003c\/p\u003e\n\u003cp\u003eThe QualiRDE™ 8000 applies this measurement principle using a holographic grating-based optical system combined with microprocessor-controlled data acquisition. Its software supports calibration management, statistical evaluation, standardization routines, and result reporting functions. Together, these capabilities help ensure stable performance and consistent analytical results across repeated testing cycles.\u003c\/p\u003e\n\u003ch2\u003eRDE-OES Standard Elemental Analyzer - QualiRDE™ 800 Technical Specification\u003c\/h2\u003e\n\u003ctable border=\"1\" class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eQualiRDE™ 800\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQualiRDE™ 800\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalytical Method\u003c\/td\u003e\n\u003ctd\u003eRotating Disc Electrode Optical Emission Spectrometer (RDE-OES)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical System\u003c\/td\u003e\n\u003ctd\u003eHigh-performance holographic diffraction grating\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGrating Density\u003c\/td\u003e\n\u003ctd\u003e2700 lines\/mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector \/ Readout\u003c\/td\u003e\n\u003ctd\u003emulti-channel acquisition architecture or a multi-block high-performance CCD detector system\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFocal Length\u003c\/td\u003e\n\u003ctd\u003e500 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral Range\u003c\/td\u003e\n\u003ctd\u003e200–800 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Limit\u003c\/td\u003e\n\u003ctd\u003eLess than 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalysis Time\u003c\/td\u003e\n\u003ctd\u003eLess than 30 seconds per test\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Preparation\u003c\/td\u003e\n\u003ctd\u003eNone required for routine analysis\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReagents \/ Gases\u003c\/td\u003e\n\u003ctd\u003eNo auxiliary solvents, gases, or additional chemical reagents required\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData System\u003c\/td\u003e\n\u003ctd\u003eMicroprocessor-controlled multi-channel integration and data acquisition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eA\/D Converter\u003c\/td\u003e\n\u003ctd\u003eHigh-speed 15-bit to 16-bit listing depending on source page\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMicrocontroller\u003c\/td\u003e\n\u003ctd\u003eSP mixed-signal flash microcontroller, 100 MHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface\u003c\/td\u003e\n\u003ctd\u003eHigh-speed USB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Functions\u003c\/td\u003e\n\u003ctd\u003eMethod creation\/editing, standardization, statistics, output options, result flagging, print\/average reporting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e220 V ±10%, single phase, 50\/60 Hz, 10 A, 1.5 kVA; 110 V available\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e810 × 500 × 675 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eContinuous Operation\u003c\/td\u003e\n\u003ctd\u003e24\/7 stability and reliability\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e\u003cstrong\u003eElement Detection Range\u003c\/strong\u003e\u003c\/p\u003e\n\u003ctable border=\"1\" class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eElement\u003c\/th\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003cth\u003eElement\u003c\/th\u003e\n\u003cth\u003eDetection Range\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFe\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003ctd\u003eBa\u003c\/td\u003e\n\u003ctd\u003e0–6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCr\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003ctd\u003eP\u003c\/td\u003e\n\u003ctd\u003e0–6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePb\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003ctd\u003eZn\u003c\/td\u003e\n\u003ctd\u003e0–6000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCu\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003ctd\u003eMo\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSn\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003ctd\u003eTi\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAl\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003ctd\u003eV\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNi\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003ctd\u003eMn\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAg\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003ctd\u003eCd\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSi\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003ctd\u003eSb\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eB\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003ctd\u003eLi\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMg\u003c\/td\u003e\n\u003ctd\u003e0–6000\u003c\/td\u003e\n\u003ctd\u003eNa\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCa\u003c\/td\u003e\n\u003ctd\u003e0–6000\u003c\/td\u003e\n\u003ctd\u003eK\u003c\/td\u003e\n\u003ctd\u003e0–1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52521745842487,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/rde-oes-standard-elemental-analyzer1577055619.webp?v=1782389088","url":"https:\/\/qualitest.us\/products\/rde-oes-standard-elemental-analyzer","provider":"Qualitest USA LC","version":"1.0","type":"link"}