{"product_id":"qualivst-300-vicat-softening-point-apparatus","title":"Vicat Softening Point Apparatus - QualiVST™ 300","description":"\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eOverview\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThe QualiVST™ 300 is a specialized \u003c\/span\u003e\u003cspan\u003evicat softening point apparatus\u003c\/span\u003e\u003cspan\u003e that also handles Heat Deflection Temperature (HDT) checks. \u003c\/span\u003e\u003c\/p\u003e\n\u003cp dir=\"ltr\"\u003e\u003cspan\u003eThis flexible system comes with a smart touchscreen that walks the operator through the entire testing sequence, from calculating the right load to getting the final information. It is made for labs that need to get exact thermal performance information on hard plastics without a complicated setup.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 dir=\"ltr\"\u003e\u003cspan\u003eFeatures \u0026amp; Benefits\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eSmart Touchscreen Guidance:\u003c\/strong\u003e\u003cspan\u003e The system's colorful screen gives you step-by-step directions, automatically figuring out the right load needed for both ASTM and ISO standards, which helps cut down on operator mistakes.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eEfficient Three-Station Setup:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eComes with three working stations that run at the same time, each one showing its own temperature and displacement information as it happens, letting you get more work done.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eAutomated Testing Sequence:\u003c\/strong\u003e\u003cspan\u003e The whole process is made to save you time. Once the test is finished, the cooling system turns on by itself, getting the machine ready for the next run with very little waiting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eEasy Data Handling:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eThe machine can keep up to 30 test results in its memory, and you can save all the raw information from a test onto a USB stick in CSV format for a closer look later.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli dir=\"ltr\" aria-level=\"1\"\u003e\n\u003cp dir=\"ltr\" role=\"presentation\"\u003e\u003cstrong\u003eDual Testing Capability:\u003c\/strong\u003e\u003cspan\u003e\u003cstrong\u003e \u003c\/strong\u003eThis single \u003c\/span\u003e\u003cspan\u003evicat softening point apparatus\u003c\/span\u003e\u003cspan\u003e can be easily set up to run both Vicat and H.D.T. tests, giving you more flexibility in your lab without needing two separate machines.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003ch2\u003eVicat VST Softening Point Temperature \/ Heat Deflection Tester QualiVST™ 300 Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature\u003c\/th\u003e\n\u003ctd\u003eRoom temperature - 300℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Control\u003c\/th\u003e\n\u003ctd\u003e50℃ increase per hour (adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eMethod A: 10N; Method B: 50N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDeflection Reading\u003c\/th\u003e\n\u003ctd\u003e0.001 ~ 3.000 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTest head Diameter\u003c\/th\u003e\n\u003ctd\u003eØ1.13mm (1mm²)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecimen Dimension\u003c\/th\u003e\n\u003ctd\u003eAt least two flat, smooth, parallel specimens with thickness 3 to 6.5mm and area 10 × 10 mm² or Ø10mm are needed.\u003cbr\u003eIf the specimen is thicker than 6mm, reduce it by half on one side and keep the other side unchanged.\u003cbr\u003eIf the thickness is below 2.5 mm, stack the specimen with less than 3 other materials and make the combination at least 3 mm thick.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Equalization Method\u003c\/th\u003e\n\u003ctd\u003eCirculation flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eCooling Method\u003c\/th\u003e\n\u003ctd\u003eWater cooling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStations\u003c\/th\u003e\n\u003ctd\u003e1, 2 or 3 stations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003eSingle phase 220VAC (110V is also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":51561774350647,"sku":null,"price":29.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/vicat-vst-softening-point-temperature-heat-deflection-tester-qualivst300353632037_jpg.avif?v=1768381386","url":"https:\/\/qualitest.us\/products\/qualivst-300-vicat-softening-point-apparatus","provider":"Qualitest USA LC","version":"1.0","type":"link"}