{"product_id":"ion-chromatograph-quali-ic-200-efficient","title":"Ion Chromatograph – Quali-IC™ 200 (Efficient)","description":"\u003ch2\u003eIon Chromatograph – Quali-IC™ 200 (Efficient)\u003c\/h2\u003e\n\u003cp\u003eIon Chromatograph – Quali-IC™ 200 is an intelligent, high-sensitivity analytical system designed for precise ionic separation and quantification in modern laboratories. Engineered around advanced ion chromatography principles, this platform integrates high-pressure pumping, electrochemical detection, and automated sample handling to deliver accurate, repeatable ion analysis across a wide concentration range.\u003c\/p\u003e\n\u003cp\u003eDesigned for IC, HPLC, and UHPLC compatibility, the Quali-IC™ 200 combines a highly sensitive electrochemical detector with flexible operating modes and robust system monitoring. Intelligent safety functions, automated injection options, and modular components make this ion chromatograph suitable for routine quality control, regulatory testing, and advanced analytical research.\u003c\/p\u003e\n\u003ch2\u003eIon Chromatograph – Quali-IC™ 200 (Efficient) Applications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Testing\u003c\/strong\u003e\u003cbr\u003eAccurate determination of anions and cations in drinking water, wastewater, surface water, and other environmental matrices.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFood \u0026amp; Beverage Analysis\u003c\/strong\u003e\u003cbr\u003eMeasurement of inorganic ions, additives, and potential contaminants to ensure quality and regulatory compliance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePharmaceutical \u0026amp; Chemical Laboratories\u003c\/strong\u003e\u003cbr\u003eSupports raw material verification, formulation testing, and impurity profiling for quality assurance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePetrochemical \u0026amp; Industrial Process Control\u003c\/strong\u003e\u003cbr\u003eMonitors ionic species in production streams to maintain process efficiency and product consistency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAcademic \u0026amp; Research Laboratories\u003c\/strong\u003e\u003cbr\u003eFacilitates high-sensitivity ion analysis, method development, and advanced research applications.\u003c\/p\u003e\n\u003cp\u003eThe Quali-IC™ 200 is designed for laboratories that require versatile, high-performance ion chromatography capable of handling diverse sample types with reliable, reproducible results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIon Chromatography – Quali-IC™ 200: Applicable Standards\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe Quali-IC™ 200 follows internationally recognized standards for accurate, reproducible, and compliant ion analysis across multiple industries.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Water and Environmental Monitoring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Anion Analysis (Water and Wastewater):\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM D2036: Standard testing for common anions (chloride, sulfate, nitrate).\u003c\/li\u003e\n\u003cli\u003eASTM D6832: Analysis of anions and cations in industrial and power-generation water.\u003c\/li\u003e\n\u003cli\u003eASTM D6919: Determination of dissolved inorganic anions in water and wastewater.\u003c\/li\u003e\n\u003cli\u003eASTM D7359: Trace-level anion measurement using suppressed conductivity detection.\u003c\/li\u003e\n\u003cli\u003eASTM D7994: Modern IC techniques for inorganic anion determination.\u003c\/li\u003e\n\u003cli\u003eUS EPA 300.0 \/ 300.1: Measurement of fluoride, chloride, nitrate, nitrite, sulfate in drinking water and wastewater.\u003c\/li\u003e\n\u003cli\u003eUS EPA 1636: Determination of inorganic anions in aqueous samples for environmental monitoring.\u003c\/li\u003e\n\u003cli\u003eDIN 38409-59 \u0026amp; EN 17813: European standards for inorganic anion measurement and compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecialized Contaminants and Matrices:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM D5794: Inorganic anions in atmospheric deposition samples (rain, snow).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003ePerchlorate Detection:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUS EPA 302.0: General environmental water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 314.0: Low-concentration perchlorate in drinking water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 332.0: Suppressed conductivity IC for perchlorate in drinking water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eDisinfection Byproducts:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUS EPA 321.8: Bromate, bromide, chlorite, chlorate in drinking water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eOrganic\/Inorganic Mix:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUS EPA 6860: Analysis of organic acids and inorganic anions in water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSolid Waste and Soil Matrices:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUS EPA 9056 \/ 9058: Inorganic anions in soils, solid waste, and aqueous extracts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e2. Combustion Ion Chromatography (Petrochemicals \u0026amp; Materials)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM D8247: Total fluorine, halogens, sulfur via combustion IC.\u003c\/li\u003e\n\u003cli\u003eUS EPA 1621: Adsorbable organic fluorine, chlorine, and bromine determination.\u003c\/li\u003e\n\u003cli\u003eUOP 991: Trace halogens and sulfur analysis in petroleum products.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3. Food, Beverage, and Nutritional Analysis (AOAC)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Food \u0026amp; Beverage:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAOAC 995.13: Chloride, nitrate, sulfate in food matrices.\u003c\/li\u003e\n\u003cli\u003eAOAC 996.04: Organic acids and inorganic ions in food and beverages.\u003c\/li\u003e\n\u003cli\u003eAOAC 997.08: Bromide and bromate detection in food and drink.\u003c\/li\u003e\n\u003cli\u003eAOAC 2000.11: Anion determination in dairy and processed foods.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecific Nutritional \u0026amp; Safety Concerns:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAOAC 2001.02: Nitrate and nitrite quantification in foods.\u003c\/li\u003e\n\u003cli\u003eAOAC 2012.20: Inorganic anion analysis in infant formula and nutritional supplements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e4. Electronics and Industrial Compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 62321: Determination of halogens in electrical and electronic products (RoHS compliance).\u003c\/li\u003e\n\u003cli\u003eIPC-TM-650 2.3.28: Measurement of ionic contamination on printed circuit boards (PCBs).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese standards ensure that the Quali-IC™ 200 provides accurate, reproducible, and regulatory-compliant ion analysis across environmental, food, pharmaceutical, chemical, and industrial applications.\u003c\/p\u003e\n\u003ch2\u003eIon Chromatograph – Quali-IC™ 200 (Efficient) Key Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-Sensitivity Electrochemical Detector\n\u003cul\u003e\n\u003cli\u003eSupports DC, pulse, and scan modes for ultra-low detection limits.\u003c\/li\u003e\n\u003cli\u003eEnables broad analytical coverage for trace and complex ionic species.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eMulti-Flow Cell Capability\n\u003cul\u003e\n\u003cli\u003eAccommodates up to three flow cells, allowing simultaneous or sequential analyses for different sample types.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdvanced Autosampler with Dilution Function\n\u003cul\u003e\n\u003cli\u003eSupports micro, partial, and full-loop injection with automatic dilution, enhancing throughput and accuracy.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eQuad-Pump System\n\u003cul\u003e\n\u003cli\u003eOperates up to four separate mobile phases, enabling gradient elution and complex separation workflows.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHigh-Pressure Analytical Pump\n\u003cul\u003e\n\u003cli\u003eDelivers stable flow up to 400 bar (5800 psi) with active pulsation compensation, ensuring reproducible chromatography.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eIntelligent System Monitoring\n\u003cul\u003e\n\u003cli\u003eIntegrated leak detection, status indicators, and automatic safety interlocks protect both samples and the instrument.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eColumn and Flow Cell Oven\n\u003cul\u003e\n\u003cli\u003eTemperature-controlled chamber improves retention time stability and analytical repeatability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eFlexible Connectivity and Control\n\u003cul\u003e\n\u003cli\u003eSupports LAN, analog, and event-based control, with optional mobile interface for remote monitoring and operation.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Quali-IC™ 220 is ideal for environmental monitoring, pharmaceutical and chemical QC, food and beverage testing, and advanced research laboratories requiring high-sensitivity, multi-phase, and high-throughput ion analysis.\u003c\/p\u003e\n\u003ch2\u003eIon Chromatograph – Quali-IC™ 200 (Efficient) Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" style=\"width:100%;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQuali-IC™ 200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalytical Technique\u003c\/td\u003e\n\u003ctd\u003eIon Chromatography\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector Type\u003c\/td\u003e\n\u003ctd\u003eElectrochemical (DC \/ Pulse \/ Scan modes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector Current Range\u003c\/td\u003e\n\u003ctd\u003e10 pA – 25 mA (mode dependent)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotential Range\u003c\/td\u003e\n\u003ctd\u003e-2.50 V to +2.50 V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNoise Level\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 2 pA (1 nA range, filter off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColumn Oven Temperature\u003c\/td\u003e\n\u003ctd\u003eAmbient +7 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Type\u003c\/td\u003e\n\u003ctd\u003eDual serial piston analytical pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pressure\u003c\/td\u003e\n\u003ctd\u003e400 bar \/ 40 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Rate Range\u003c\/td\u003e\n\u003ctd\u003e0.001 – 10 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Accuracy\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Precision\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.1% RSD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutosampler Injection Volume\u003c\/td\u003e\n\u003ctd\u003e1 µL – 1000 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInjection Precision\u003c\/td\u003e\n\u003ctd\u003e≤ 0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry-Over\u003c\/td\u003e\n\u003ctd\u003e≤ 0.001%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegasser\u003c\/td\u003e\n\u003ctd\u003e4-channel membrane degasser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Interfaces\u003c\/td\u003e\n\u003ctd\u003eLAN, analog input, event I\/O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e4–40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × L × H)\u003c\/td\u003e\n\u003ctd\u003e361 × 523 × 208 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApprox. 14 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":51720601895223,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/ion-chromatograph-quali-ictm-200.webp?v=1772045149","url":"https:\/\/qualitest.us\/products\/ion-chromatograph-quali-ic-200-efficient","provider":"Qualitest USA LC","version":"1.0","type":"link"}