{"product_id":"ion-chromatograph-quali-ic-180","title":"Ion Chromatograph – Quali-IC™ 180","description":"\u003ch2\u003eIon Chromatograph – Quali-IC™ 180\u003c\/h2\u003e\n\u003cp\u003eThe Quali-IC™ 180 is a high-performance, intelligent ion chromatograph engineered for precise separation and quantification of anions and cations in complex sample matrices. Featuring advanced eluent generation, high-pressure pumping, and ultra-sensitive conductivity detection, it delivers stable, reproducible results suitable for both routine testing and advanced analytical applications.\u003c\/p\u003e\n\u003cp\u003eEquipped with real-time system monitoring, automated degassing, and intelligent workflow management, the Quali-IC™ 180 streamlines ion chromatography processes while ensuring exceptional analytical accuracy and reliability.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eIon Chromatograph – Quali-IC™ 180 Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEnvironmental Monitoring – Accurate determination of inorganic anions and cations in drinking water, wastewater, and surface water.\u003c\/li\u003e\n\u003cli\u003ePharmaceutical \u0026amp; Biotechnology – Analysis of counter-ions, impurities, and raw materials for quality control.\u003c\/li\u003e\n\u003cli\u003eFood \u0026amp; Beverage Testing – Measurement of preservatives, additives, and ionic contaminants in diverse food matrices.\u003c\/li\u003e\n\u003cli\u003eChemical \u0026amp; Petrochemical Industries – Quality control of process chemicals, reagents, and intermediates.\u003c\/li\u003e\n\u003cli\u003ePower \u0026amp; Electronics – Trace ion analysis in ultrapure water and electronic-grade chemicals to ensure system reliability.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandards for Ion Chromatography (IC) – Quali-IC™ 180\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis compilation summarizes key standardized methods for ion chromatography across water, environmental, food, and electronics applications, ensuring accuracy, reproducibility, and regulatory compliance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Water and Environmental Analysis (ASTM \u0026amp; US EPA)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Anion Analysis (Water and Wastewater)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM D2036 – Test methods for common anions (chloride, sulfate, nitrate) in water.\u003c\/li\u003e\n\u003cli\u003eASTM D5794 – Determination of inorganic anions in atmospheric deposition samples.\u003c\/li\u003e\n\u003cli\u003eASTM D6832 – Analysis of anions and cations in water for power generation and industrial processes.\u003c\/li\u003e\n\u003cli\u003eASTM D6919 – Methods for measuring anions in water and wastewater.\u003c\/li\u003e\n\u003cli\u003eASTM D7359 – Trace anion measurement using suppressed conductivity detection.\u003c\/li\u003e\n\u003cli\u003eASTM D7994 – Modern IC techniques for inorganic anions in water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 300.0 \/ 300.1 – Measurement of fluoride, chloride, nitrate, nitrite, and sulfate in drinking water and wastewater.\u003c\/li\u003e\n\u003cli\u003eUS EPA 302.0 – Perchlorate determination in environmental water samples.\u003c\/li\u003e\n\u003cli\u003eUS EPA 314.0 – Low-concentration perchlorate detection in drinking water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 321.8 – Bromate, bromide, chlorite, and chlorate analysis in drinking water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 332.0 – Suppressed conductivity IC for perchlorate in drinking water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 1636 – Procedures for measuring inorganic anions in aqueous samples for environmental monitoring.\u003c\/li\u003e\n\u003cli\u003eUS EPA 6860 – IC determination of inorganic anions and organic acids in water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 9056 \/ 9058 – Analysis of inorganic anions in solid waste, soils, and aqueous extracts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e2. Combustion Ion Chromatography (Halogens \u0026amp; Sulfur)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM D8247 – Determination of halogens, sulfur, and fluorine in materials via combustion IC.\u003c\/li\u003e\n\u003cli\u003eUS EPA 1621 – Measurement of total organic fluorine, chlorine, and bromine using combustion IC.\u003c\/li\u003e\n\u003cli\u003eUOP 991 – Trace halogens and sulfur analysis in petroleum products.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3. Food and Nutritional Products (AOAC)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Food and Beverage Analysis\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAOAC 995.13 – Chloride, nitrate, and sulfate measurement in foods.\u003c\/li\u003e\n\u003cli\u003eAOAC 996.04 – Organic acids and inorganic ion analysis in food and beverages.\u003c\/li\u003e\n\u003cli\u003eAOAC 997.08 – Bromide and bromate detection in food and drinks.\u003c\/li\u003e\n\u003cli\u003eAOAC 2000.11 – Anion determination in dairy and processed foods.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecific Nutritional and Safety Analysis\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAOAC 2001.02 – Nitrate and nitrite quantification in foods.\u003c\/li\u003e\n\u003cli\u003eAOAC 2012.20 – Inorganic anion analysis in infant formula and nutritional supplements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e4. Electronics and Industrial Compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 62321 – Determination of halogens in electrical and electronic materials (RoHS compliance).\u003c\/li\u003e\n\u003cli\u003eDIN 38409-59 – IC methods for measuring inorganic anions in water and wastewater.\u003c\/li\u003e\n\u003cli\u003eEN 17813 – IC determination of anions in water for environmental compliance in Europe.\u003c\/li\u003e\n\u003cli\u003eIPC-TM-650 2.3.28 – Measurement of ionic contamination on printed circuit boards (PCBs).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis standard reference list ensures that Quali-IC™ 180 meets international regulatory and industry requirements across all critical applications.\u003c\/p\u003e\n\u003ch2\u003eIon Chromatograph – Quali-IC™ 180 Key Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Definition Touchscreen Interface\u003c\/strong\u003e\u003cbr\u003eProvides real-time visualization of flow paths, operating status, and analytical parameters for intuitive control and monitoring.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-In Eluent Generator\u003c\/strong\u003e\u003cbr\u003eSupports KOH, NaOH, LiOH, and MSA eluents with precise concentration control for accurate isocratic or gradient elution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent Monitoring System\u003c\/strong\u003e\u003cbr\u003eContinuously detects eluent levels and system status, preventing interruptions during analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Degassing Technology\u003c\/strong\u003e\u003cbr\u003eIntegrated heating and vacuum degassing ensures baseline stability and improves measurement accuracy.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Pressure, Low-Pulse Pump Design\u003c\/strong\u003e\u003cbr\u003eDelivers precise flow with minimal pressure ripple, supporting reproducible chromatographic performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eElectrolytic Self-Regenerating Suppressor\u003c\/strong\u003e\u003cbr\u003eProvides stable suppression for conductivity detection with reduced maintenance requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSmart Connectivity\u003c\/strong\u003e\u003cbr\u003eOptional mobile app enables remote monitoring and real-time tracking of analytical runs, enhancing workflow flexibility.\u003c\/p\u003e\n\u003ch2\u003eIon Chromatograph – Quali-IC™ 180 Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" style=\"width:100%;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Type\u003c\/td\u003e\n\u003ctd\u003eIon Chromatograph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEluent Types\u003c\/td\u003e\n\u003ctd\u003eKOH \/ NaOH \/ LiOH \/ MSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEluent Concentration Range\u003c\/td\u003e\n\u003ctd\u003e0.1 – 100 mM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Rate Range\u003c\/td\u003e\n\u003ctd\u003e0.001 – 12 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum System Pressure\u003c\/td\u003e\n\u003ctd\u003eUp to 42 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGradient Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegassing Method\u003c\/td\u003e\n\u003ctd\u003eBuilt-in heating vacuum degasser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Detector\u003c\/td\u003e\n\u003ctd\u003eAuto-range conductivity detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003c\/td\u003e\n\u003ctd\u003e0 – 50,000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Resolution\u003c\/td\u003e\n\u003ctd\u003e≤ 0.0020 nS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline Noise\u003c\/td\u003e\n\u003ctd\u003e≤ 0.0005 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e≥ 0.999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantitative Repeatability\u003c\/td\u003e\n\u003ctd\u003e≤ 0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualitative Repeatability\u003c\/td\u003e\n\u003ctd\u003e≤ 0.2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColumn Compatibility\u003c\/td\u003e\n\u003ctd\u003e2–5 mm I.D., up to 250 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColumn Oven Temperature\u003c\/td\u003e\n\u003ctd\u003eAmbient +5 to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e150 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e361 × 504 × 610 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":51720523120951,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/ion-chromatograph-quali-ictm-180.webp?v=1772044369","url":"https:\/\/qualitest.us\/products\/ion-chromatograph-quali-ic-180","provider":"Qualitest USA LC","version":"1.0","type":"link"}