{"product_id":"ion-chromatograph-quali-ic-150","title":"Ion Chromatograph – Quali-IC™ 150+","description":"\u003ch1\u003eIon Chromatograph – Quali-IC™ 150+\u003c\/h1\u003e\n\u003cp\u003eThe Quali-IC™ 150+ is a high-performance ion chromatograph designed for precise, stable, and automated analysis of anions and cations in demanding laboratory environments. It delivers reliable separation and quantification across a wide concentration range, from trace-level ppb to higher ppm samples.\u003c\/p\u003e\n\u003cp\u003eWith chemically inert, metal-free flow paths and built-in intelligent system protection, the Quali-IC™ 150+ ensures low background noise, excellent reproducibility, and long-term operational stability. Its integrated automation features, smart diagnostics, and compact design make it ideal for both routine testing and advanced analytical workflows.\u003c\/p\u003e\n\u003ch2\u003eIon Chromatograph – Quali-IC™ 150+ Applications\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003eThe Ion Chromatograph – Quali-IC™ 150+ is widely applied for ionic analysis in the following areas:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Testing\u003c\/strong\u003e\u003cbr\u003eDetermination of anions and cations in drinking water, wastewater, surface water, and other environmental monitoring samples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFood \u0026amp; Beverage Analysis\u003c\/strong\u003e\u003cbr\u003eMeasurement of preservatives, additives, organic acids, and inorganic ions to ensure product quality and safety compliance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePharmaceutical \u0026amp; Chemical Industries\u003c\/strong\u003e\u003cbr\u003eAnalysis of raw materials, intermediates, and finished products for ionic purity and quality control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower \u0026amp; Electronics\u003c\/strong\u003e\u003cbr\u003eDetection of trace ionic contaminants that could affect system reliability and component performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResearch \u0026amp; Academic Laboratories\u003c\/strong\u003e\u003cbr\u003eHigh-precision ion separation and quantification for method development, validation, and scientific research.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards for Ion Chromatography (IC) – Quali-IC™ 150+\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards provide validated methods for ion chromatography across water, environmental, food, pharmaceutical, and electronics applications, ensuring accurate, reproducible, and compliant results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Water \u0026amp; Environmental Monitoring (ASTM \u0026amp; US EPA)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Anion Analysis\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM D2036: Standard testing for common anions (chloride, sulfate, nitrate) in water.\u003c\/li\u003e\n\u003cli\u003eASTM D6832: Analysis of anions and cations in water for industrial processes and power generation.\u003c\/li\u003e\n\u003cli\u003eASTM D6919: Determination of dissolved inorganic anions in water and wastewater.\u003c\/li\u003e\n\u003cli\u003eASTM D7359: Trace anion measurement in water using suppressed conductivity detection.\u003c\/li\u003e\n\u003cli\u003eASTM D7994: Modern IC techniques for inorganic anion determination in water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 300.0 \/ 300.1: Measurement of inorganic anions (fluoride, chloride, nitrate, nitrite, sulfate) in drinking water and wastewater.\u003c\/li\u003e\n\u003cli\u003eUS EPA 1636: Determination of inorganic anions in aqueous samples for environmental monitoring.\u003c\/li\u003e\n\u003cli\u003eDIN 38409-59 \u0026amp; EN 17813: European standards for measuring inorganic anions in water and wastewater for compliance.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecialized Contaminants \u0026amp; Matrices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM D5794: Analysis of inorganic anions in atmospheric deposition (rain\/snow) samples.\u003c\/li\u003e\n\u003cli\u003eUS EPA 302.0: Detection of perchlorate in environmental water samples.\u003c\/li\u003e\n\u003cli\u003eUS EPA 314.0: Low-level perchlorate detection in drinking water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 332.0: Perchlorate analysis in drinking water using suppressed conductivity IC.\u003c\/li\u003e\n\u003cli\u003eUS EPA 321.8: Determination of bromate, bromide, chlorite, and chlorate in drinking water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 6860: Analysis of organic acids and inorganic anions in water.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSolid Waste \u0026amp; Soils\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eUS EPA 9056 \/ 9058: Protocols for analyzing inorganic anions in soils, solid waste, and aqueous extracts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e2. Combustion Ion Chromatography (Petrochemicals \u0026amp; Materials)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM D8247: Determination of total fluorine, halogens, and sulfur in materials via combustion IC.\u003c\/li\u003e\n\u003cli\u003eUS EPA 1621: Procedures for measuring adsorbable organic fluorine, chlorine, and bromine.\u003c\/li\u003e\n\u003cli\u003eUOP 991: Analysis of trace halogens and sulfur in petroleum products.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3. Food, Beverage, \u0026amp; Nutritional Analysis (AOAC)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGeneral Food \u0026amp; Beverage\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAOAC 995.13: Measurement of chloride, nitrate, and sulfate in various food matrices.\u003c\/li\u003e\n\u003cli\u003eAOAC 996.04: Analysis of organic acids and inorganic ions in food and beverage products.\u003c\/li\u003e\n\u003cli\u003eAOAC 997.08: Detection of bromide and bromate in food and drink.\u003c\/li\u003e\n\u003cli\u003eAOAC 2000.11: Anion determination specifically for dairy and processed foods.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eSpecific Nutritional Concerns\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAOAC 2001.02: Quantification of nitrate and nitrite levels in foods.\u003c\/li\u003e\n\u003cli\u003eAOAC 2012.20: Inorganic anion analysis in infant formula and nutritional supplements.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e4. Electronics \u0026amp; Industrial Compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 62321: Determination of halogens in electrical and electronic products (RoHS compliance).\u003c\/li\u003e\n\u003cli\u003eIPC-TM-650 2.3.28: Measurement of ionic contamination levels on printed circuit boards (PCBs).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese standards provide laboratories with reliable protocols for accurate, reproducible ion chromatography analysis across environmental, industrial, food, and electronics applications.\u003c\/p\u003e\n\u003ch2\u003eIon Chromatograph – Quali-IC™ 150+ Key Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIntelligent Leakage Alarm System: Automatically detects liquid leaks, sounds alerts, and safely shuts down the pump to protect the instrument and laboratory environment.\u003c\/li\u003e\n\u003cli\u003eAutomatic Signal Range Selection: Seamlessly measures ions from ppb to ppm without manual adjustment, improving accuracy and ease of use.\u003c\/li\u003e\n\u003cli\u003eIntegrated Gas–Liquid Separator: Eliminates bubbles from the eluent flow path, reducing baseline noise and enhancing detection sensitivity.\u003c\/li\u003e\n\u003cli\u003eTimed Startup Preheating: Allows preprogrammed system startup and equilibration for faster readiness and improved workflow efficiency.\u003c\/li\u003e\n\u003cli\u003eIntelligent Maintenance Mode: Automates flow-path cleaning using pure water, reducing manual intervention and extending component lifespan.\u003c\/li\u003e\n\u003cli\u003eMobile App Control Capability: Enables remote monitoring and basic operation through a mobile interface for enhanced flexibility.\u003c\/li\u003e\n\u003cli\u003eLarge Intelligent Touchscreen Interface: Displays real-time system status, provides parameter control, and simplifies maintenance access.\u003c\/li\u003e\n\u003cli\u003eChemically Inert PEEK Flow Path: Metal-free construction ensures compatibility with aggressive eluents while preventing sample contamination.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIon Chromatograph – Quali-IC™ 150+ Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" style=\"width:100%;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQuali-IC™ 150+\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Type\u003c\/td\u003e\n\u003ctd\u003eIon Chromatograph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Path Material\u003c\/td\u003e\n\u003ctd\u003eChemically inert, metal-free PEEK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Compatibility\u003c\/td\u003e\n\u003ctd\u003epH 0–14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Type\u003c\/td\u003e\n\u003ctd\u003eHigh-pressure, low-pulse dual-piston pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pump Pressure\u003c\/td\u003e\n\u003ctd\u003e42 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Rate Range\u003c\/td\u003e\n\u003ctd\u003e0.001 – 12 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Accuracy\u003c\/td\u003e\n\u003ctd\u003e≤ ±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Precision\u003c\/td\u003e\n\u003ctd\u003e≤ ±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Ripple\u003c\/td\u003e\n\u003ctd\u003e≤ 0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColumn Heater Temperature Range\u003c\/td\u003e\n\u003ctd\u003eAmbient +5 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Control Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuppressor Type\u003c\/td\u003e\n\u003ctd\u003eSelf-regenerating electrolytic micro-membrane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Detector\u003c\/td\u003e\n\u003ctd\u003eAuto-range conductivity detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003c\/td\u003e\n\u003ctd\u003e0 – 45,000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline Noise\u003c\/td\u003e\n\u003ctd\u003e≤ 0.001 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline Drift\u003c\/td\u003e\n\u003ctd\u003e≤ 0.005 µS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Detectable Concentration\u003c\/td\u003e\n\u003ctd\u003eCl⁻ ≤ 0.0003 µg\/mL; Li⁺ ≤ 0.0001 µg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e≥ 0.999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRepeatability (Qualitative)\u003c\/td\u003e\n\u003ctd\u003e≤ 0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e150 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e336 × 458 × 650 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e25.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":51720385003831,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/ion-chromatograph-quali-ictm-150.webp?v=1772043527","url":"https:\/\/qualitest.us\/products\/ion-chromatograph-quali-ic-150","provider":"Qualitest USA LC","version":"1.0","type":"link"}