{"product_id":"ion-chromatograph-quali-ic-120","title":"Ion Chromatograph – Quali-IC™ 120+","description":"\u003ch2\u003eIon Chromatograph – Quali-IC™ 120+\u003c\/h2\u003e\n\u003cp\u003eThe Quali-IC™ 120+ is a high-performance ion chromatograph designed for precise and reliable analysis in environmental, industrial, and research laboratories. It provides accurate separation, identification, and quantification of anions and cations using high-sensitivity conductivity detection, covering trace (ppb) to higher (ppm) concentration levels.\u003c\/p\u003e\n\u003cp\u003eEquipped with intelligent safety monitoring, automated conductivity range adjustment, and chemically inert flow paths, the Quali-IC™ 120+ ensures stable long-term performance with minimal operator intervention. Its compact footprint, optional high-precision autosampler, and advanced data processing software make it ideal for both routine testing and demanding analytical workflows.\u003c\/p\u003e\n\u003ch2\u003eIon Chromatograph – Quali-IC™ 120+ Applications\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Monitoring\u003c\/strong\u003e\u003cbr\u003eDetermination of inorganic anions and cations in drinking water, wastewater, surface water, and groundwater.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFood \u0026amp; Beverage Testing\u003c\/strong\u003e\u003cbr\u003eAnalysis of preservatives, additives, and ionic contaminants to ensure product quality and safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePharmaceutical \u0026amp; Chemical Industries\u003c\/strong\u003e\u003cbr\u003eQuality control of raw materials, intermediates, and finished products.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower Generation \u0026amp; Electronics\u003c\/strong\u003e\u003cbr\u003eMonitoring ionic impurities in boiler water, ultrapure water, and electronic-grade chemicals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResearch \u0026amp; Academic Laboratories\u003c\/strong\u003e\u003cbr\u003eSupport for method development and advanced ion separation studies in educational and research settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards for Ion Chromatography (IC) Analysis\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards provide validated methods for ion chromatography across water, environmental, food, pharmaceutical, and electronics applications, ensuring accurate, repeatable, and regulatory-compliant results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Water and Environmental Analysis (ASTM \u0026amp; US EPA)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM D2036: Standard methods for analyzing common anions (chloride, sulfate, nitrate) in water.\u003c\/li\u003e\n\u003cli\u003eASTM D5794: IC determination of inorganic anions in atmospheric deposition samples.\u003c\/li\u003e\n\u003cli\u003eASTM D6832: Analysis of anions and cations in water used for power generation and industrial processes.\u003c\/li\u003e\n\u003cli\u003eASTM D6919: IC methods for determining anions in water and wastewater samples.\u003c\/li\u003e\n\u003cli\u003eASTM D7359: Measurement of trace anions in water using suppressed conductivity IC detection.\u003c\/li\u003e\n\u003cli\u003eASTM D7994: Determination of inorganic anions in water using modern IC techniques.\u003c\/li\u003e\n\u003cli\u003eUS EPA 300.0 \/ 300.1: IC measurement of fluoride, chloride, nitrate, nitrite, and sulfate in drinking water and wastewater.\u003c\/li\u003e\n\u003cli\u003eUS EPA 302.0: Determination of perchlorate in environmental water samples.\u003c\/li\u003e\n\u003cli\u003eUS EPA 314.0: Low-level perchlorate detection in drinking water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 321.8: Determination of bromate, bromide, chlorite, and chlorate in drinking water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 332.0: Perchlorate analysis in drinking water using suppressed conductivity IC.\u003c\/li\u003e\n\u003cli\u003eUS EPA 1636: Procedures for measuring inorganic anions in aqueous samples for environmental monitoring.\u003c\/li\u003e\n\u003cli\u003eUS EPA 6860: IC determination of inorganic anions and organic acids in water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 9056 \/ 9058: Analysis of inorganic anions in solid waste, soils, and aqueous extracts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e2. Combustion Ion Chromatography (Halogens \u0026amp; Sulfur)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM D8247: Analysis of halogens, sulfur, and fluorine in materials using combustion IC.\u003c\/li\u003e\n\u003cli\u003eUS EPA 1621: Procedures for total organic fluorine, chlorine, and bromine using combustion IC.\u003c\/li\u003e\n\u003cli\u003eUOP 991: Combustion IC methods for total halogens and sulfur in petroleum products.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3. Food and Nutritional Products (AOAC)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAOAC 2001.02: Determination of nitrate and nitrite in foods.\u003c\/li\u003e\n\u003cli\u003eAOAC 2012.20: Measurement of inorganic anions in infant formula and nutritional products.\u003c\/li\u003e\n\u003cli\u003eAOAC 995.13: Determination of chloride, nitrate, and sulfate in foods.\u003c\/li\u003e\n\u003cli\u003eAOAC 996.04: Analysis of organic acids and inorganic ions in beverages and food products.\u003c\/li\u003e\n\u003cli\u003eAOAC 997.08: Detection of bromide and bromate in food and beverage matrices.\u003c\/li\u003e\n\u003cli\u003eAOAC 2000.11: Determination of anions in dairy and processed food products.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e4. Industry and Compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 62321: Analytical methods, including IC, for halogen determination in electrical and electronic materials (RoHS compliance).\u003c\/li\u003e\n\u003cli\u003eDIN 38409-59: IC procedures for measuring inorganic anions in water and wastewater.\u003c\/li\u003e\n\u003cli\u003eEN 17813: IC determination of anions in water samples for European environmental compliance.\u003c\/li\u003e\n\u003cli\u003eIPC-TM-650 2.3.28: IC methods for measuring ionic contamination on printed circuit boards (PCBs).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese standards provide laboratories with reliable protocols for accurate, reproducible ion chromatography analysis across environmental, industrial, food, and electronics applications.\u003c\/p\u003e\n\u003ch2\u003eIon Chromatograph – Quali-IC™ 120+ Key Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAccurate Anion and Cation Analysis: Engineered for precise separation and quantification of ions across a wide concentration range.\u003c\/li\u003e\n\u003cli\u003eAutomatic Range Conductivity Detector: Measures ppb to ppm levels without requiring manual adjustment.\u003c\/li\u003e\n\u003cli\u003eReal-Time Safety Monitoring: Includes pressure, liquid leakage, and eluent alarms with automatic system shutdown for protection.\u003c\/li\u003e\n\u003cli\u003eSelf-Regenerating Electrolytic Suppressor: Maintains a stable baseline while reducing maintenance requirements.\u003c\/li\u003e\n\u003cli\u003eGas–Liquid Separator: Removes bubbles from the flow path to enhance signal stability and measurement reliability.\u003c\/li\u003e\n\u003cli\u003eChemically Inert PEEK Flow Path: Metal-free design compatible with eluents from pH 0–14, minimizing contamination.\u003c\/li\u003e\n\u003cli\u003eOptional High-Performance Autosampler: Provides precise, repeatable sample injection for consistent results.\u003c\/li\u003e\n\u003cli\u003eIntelligent Software Algorithms: Includes baseline deduction and filtering to reduce gradient-related drift.\u003c\/li\u003e\n\u003cli\u003eProgrammable Startup and Warm-Up: Prepares the system for analysis before operator arrival, ensuring readiness.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIon Chromatograph – Quali-IC™ 120+ Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" style=\"width:100%;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Type\u003c\/td\u003e\n\u003ctd\u003eIon Chromatograph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Method\u003c\/td\u003e\n\u003ctd\u003eAuto-range conductivity detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003c\/td\u003e\n\u003ctd\u003e0–50,000 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e≤ 0.0020 nS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline Noise\u003c\/td\u003e\n\u003ctd\u003e≤ 0.001 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline Drift\u003c\/td\u003e\n\u003ctd\u003e≤ 0.01 μS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e≥ 0.999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantitative Repeatability\u003c\/td\u003e\n\u003ctd\u003e≤ 0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Detectable Concentration\u003c\/td\u003e\n\u003ctd\u003eCl⁻ ≤ 0.0005 μg\/mL; Li⁺ ≤ 0.0005 μg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Type\u003c\/td\u003e\n\u003ctd\u003eHigh-pressure, low-pulse dual-piston pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pump Pressure\u003c\/td\u003e\n\u003ctd\u003e42 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Rate Range\u003c\/td\u003e\n\u003ctd\u003e0.001 – 12 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Accuracy\u003c\/td\u003e\n\u003ctd\u003e≤ 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColumn Heater Range\u003c\/td\u003e\n\u003ctd\u003eAmbient +5 °C to 85 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Stability\u003c\/td\u003e\n\u003ctd\u003e≤ 0.1 °C\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuppressor Type\u003c\/td\u003e\n\u003ctd\u003eSelf-regenerating electrolytic micro-membrane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector Cell Volume\u003c\/td\u003e\n\u003ctd\u003e≤ 0.4 μL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutosampler (Optional)\u003c\/td\u003e\n\u003ctd\u003eUp to 120 vials (2 mL), multiple vial size options\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInjection Volume\u003c\/td\u003e\n\u003ctd\u003e1 – 1000 μL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarry-Over\u003c\/td\u003e\n\u003ctd\u003e≤ 0.001%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e150 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e360 × 500 × 560 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e30 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":51720347615543,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/ion-chromatograph-quali-ictm-120.webp?v=1772043119","url":"https:\/\/qualitest.us\/products\/ion-chromatograph-quali-ic-120","provider":"Qualitest USA LC","version":"1.0","type":"link"}