{"product_id":"ion-chromatograph-quali-ic-100-new","title":"Ion Chromatograph – Quali-IC™ 100 (New)","description":"\u003ch2\u003eIon Chromatograph – Quali-IC™ 100 (New)\u003c\/h2\u003e\n\u003cp\u003eThe Quali-IC™ 100 is a compact, reliable ion chromatograph designed for precise qualitative and quantitative analysis of inorganic anions and cations in aqueous samples. Featuring a high-performance dual-piston pumping system and metal-free flow paths, it provides stable baselines, excellent reproducibility, and dependable analytical performance for routine laboratory testing.\u003c\/p\u003e\n\u003cp\u003eBuilt for practical use, the Quali-IC™ 100 includes intelligent temperature control, automated post-flushing, and high-sensitivity conductivity detection. Its compact design and straightforward operation make it ideal for environmental, industrial, academic, and quality control laboratories that require consistent, accurate ion analysis without added complexity.\u003c\/p\u003e\n\u003ch2\u003eIon Chromatograph – Quali-IC™ 100 (New) Applications\u003c\/h2\u003e\n\u003cp\u003eThe Ion Chromatograph – Quali-IC™ 100 is widely used in the following applications:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Analysis\u003c\/strong\u003e\u003cbr\u003eMeasurement of anions and cations in drinking water, wastewater, and surface water for monitoring and compliance purposes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIndustrial Process Monitoring\u003c\/strong\u003e\u003cbr\u003eAnalysis of boiler water, cooling water, and chemical production streams to support process control and quality assurance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFood and Beverage Testing\u003c\/strong\u003e\u003cbr\u003eDetermination of ionic content for quality control in food and beverage products.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePharmaceutical and Chemical Laboratories\u003c\/strong\u003e\u003cbr\u003eSupport for raw material testing and formulation verification to ensure product consistency and safety.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAcademic and Research Institutions\u003c\/strong\u003e\u003cbr\u003eRoutine ion chromatography for educational purposes and applied research projects.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards for Ion Chromatography (IC)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe following standards provide validated methods for ion chromatography across water, environmental, food, pharmaceutical, and electronics applications, ensuring accurate, repeatable, and regulatory-compliant analysis.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM D2036: Standard methods for analyzing anions such as chloride, sulfate, and nitrate in water.\u003c\/li\u003e\n\u003cli\u003eASTM D5794: IC determination of inorganic anions in atmospheric deposition samples.\u003c\/li\u003e\n\u003cli\u003eASTM D6832: Analysis of anions and cations in water used for power generation and industrial processes.\u003c\/li\u003e\n\u003cli\u003eASTM D6919: IC methods for determining anions in water and wastewater.\u003c\/li\u003e\n\u003cli\u003eASTM D7359: Trace anion measurement in water using suppressed conductivity IC detection.\u003c\/li\u003e\n\u003cli\u003eASTM D7994: Determination of inorganic anions in water using modern IC techniques.\u003c\/li\u003e\n\u003cli\u003eUS EPA 300.0 \/ 300.1: Measurement of fluoride, chloride, nitrate, nitrite, and sulfate in drinking water and wastewater.\u003c\/li\u003e\n\u003cli\u003eUS EPA 302.0: Determination of perchlorate in environmental water samples.\u003c\/li\u003e\n\u003cli\u003eUS EPA 314.0: Low-level perchlorate detection in drinking water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 321.8: Determination of bromate, bromide, chlorite, and chlorate in drinking water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 332.0: Analysis of perchlorate in drinking water using suppressed conductivity IC.\u003c\/li\u003e\n\u003cli\u003eUS EPA 9056 \/ 9058: Methods for analyzing inorganic anions in solid waste, soils, and aqueous extracts.\u003c\/li\u003e\n\u003cli\u003eUS EPA 1636: Procedures for measuring inorganic anions in aqueous samples for environmental monitoring.\u003c\/li\u003e\n\u003cli\u003eUS EPA 6860: Determination of inorganic anions and organic acids in water.\u003c\/li\u003e\n\u003cli\u003eDIN 38409-59: IC procedures for measuring inorganic anions in water and wastewater (European standard).\u003c\/li\u003e\n\u003cli\u003eEN 17813: IC determination of anions in water for environmental compliance in Europe.\u003c\/li\u003e\n\u003cli\u003eAOAC 2001.02: Nitrate and nitrite determination in foods using IC.\u003c\/li\u003e\n\u003cli\u003eAOAC 2012.20: Measurement of inorganic anions in infant formula and nutritional products.\u003c\/li\u003e\n\u003cli\u003eAOAC 995.13: Determination of chloride, nitrate, and sulfate in foods.\u003c\/li\u003e\n\u003cli\u003eAOAC 996.04: Analysis of organic acids and inorganic ions in beverages and food products.\u003c\/li\u003e\n\u003cli\u003eAOAC 997.08: Detection of bromide and bromate in food and beverage matrices.\u003c\/li\u003e\n\u003cli\u003eAOAC 2000.11: Determination of anions in dairy and processed food products.\u003c\/li\u003e\n\u003cli\u003eASTM D8247: Analysis of halogens, sulfur, and fluorine in materials using combustion IC.\u003c\/li\u003e\n\u003cli\u003eUOP 991: Combustion IC methods for total halogens and sulfur in petroleum products.\u003c\/li\u003e\n\u003cli\u003eUS EPA 1621: Procedures for total organic fluorine, chlorine, and bromine using combustion IC.\u003c\/li\u003e\n\u003cli\u003eIEC 62321: Analytical methods, including IC, for halogen determination in electrical and electronic materials (RoHS compliance).\u003c\/li\u003e\n\u003cli\u003eIPC-TM-650 2.3.28: IC methods for measuring ionic contamination on printed circuit boards (PCBs).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIon Chromatograph – Quali-IC™ 100 (New) Key Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eHigh-Performance Dual-Piston Pump: Delivers high-pressure, low-pulsation flow for consistent chromatographic performance.\u003c\/li\u003e\n\u003cli\u003eWide Flow Rate Range: Adjustable from 0.001 to 12 mL\/min, providing flexibility for different column sizes and analytical methods.\u003c\/li\u003e\n\u003cli\u003eMetal-Free PEEK Flow Path: Chemically inert design compatible with eluents across pH 0–14, minimizing contamination risk.\u003c\/li\u003e\n\u003cli\u003eBuilt-In Peristaltic Pump: Enables automatic post-analysis flushing to maintain system cleanliness and long-term stability.\u003c\/li\u003e\n\u003cli\u003e3D Circulating Constant Temperature Control: Achieves thermal stability in under 30 minutes, enhancing baseline stability and analytical accuracy.\u003c\/li\u003e\n\u003cli\u003eGas–Liquid Separator: Removes bubbles from the flow path, ensuring a stable detector baseline.\u003c\/li\u003e\n\u003cli\u003eIntelligent Integrated Workstation: Centralized platform for startup, shutdown, maintenance, and multi-instrument management.\u003c\/li\u003e\n\u003cli\u003eSelf-Regenerating Suppressor Technology: Electrolytic micro-membrane suppressor increases sensitivity while reducing maintenance needs.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eIon Chromatograph – Quali-IC™ 100 (New) Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" style=\"width:100%;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQuali-IC™ 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Type\u003c\/td\u003e\n\u003ctd\u003eIon Chromatograph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Path Material\u003c\/td\u003e\n\u003ctd\u003eMetal-free PEEK\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEluent Compatibility\u003c\/td\u003e\n\u003ctd\u003epH 0–14, aqueous and compatible solvents\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Type\u003c\/td\u003e\n\u003ctd\u003eHigh-pressure, low-pulse dual-piston tandem pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pressure (Pump)\u003c\/td\u003e\n\u003ctd\u003e42 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Rate Range\u003c\/td\u003e\n\u003ctd\u003e0.001 – 12 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Stability\u003c\/td\u003e\n\u003ctd\u003e≤ 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Ripple\u003c\/td\u003e\n\u003ctd\u003e≤ 0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColumn Heater Temperature Range\u003c\/td\u003e\n\u003ctd\u003eAmbient +5 °C to 60 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Control Accuracy (Column)\u003c\/td\u003e\n\u003ctd\u003e±0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuppressor Type\u003c\/td\u003e\n\u003ctd\u003eSelf-regenerating electrolytic micro-membrane\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuppressor Max Pressure\u003c\/td\u003e\n\u003ctd\u003e6.0 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Method\u003c\/td\u003e\n\u003ctd\u003eConductivity detection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector Cell Volume\u003c\/td\u003e\n\u003ctd\u003e≤ 0.4 μL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003c\/td\u003e\n\u003ctd\u003e0 – 50,000 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline Noise\u003c\/td\u003e\n\u003ctd\u003e≤ 0.0003 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline Drift\u003c\/td\u003e\n\u003ctd\u003e≤ 0.001 µS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Detection Limit\u003c\/td\u003e\n\u003ctd\u003eCl⁻ ≤ 0.0001 µg\/mL; Li⁺ ≤ 0.0001 µg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e≥ 0.999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantitative Repeatability\u003c\/td\u003e\n\u003ctd\u003e≤ 0.25%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualitative Repeatability\u003c\/td\u003e\n\u003ctd\u003e≤ 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e150 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e310 × 400 × 530 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e22 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":51720280965431,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/ion-chromatograph-quali-ictm-100.webp?v=1772042355","url":"https:\/\/qualitest.us\/products\/ion-chromatograph-quali-ic-100-new","provider":"Qualitest USA LC","version":"1.0","type":"link"}