{"product_id":"integrated-heating-temperature-control-system","title":"Integrated Heating Temperature Control System","description":"\u003ch2 class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eIntegrated Heating Temperature Control System – QualiHeat™ IH Series\u003c\/span\u003e\u003c\/h2\u003e\n\u003ch3\u003e\u003cspan class=\"\"\u003eProcess Thermostat \u0026amp; Heating System (50°C to 300°C)\u003c\/span\u003e\u003c\/h3\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThis process thermostat and heating temperature control system maintains your process fluid at a precise setpoint while circulating it through reactor jackets, heat exchangers, or external loops. The QualiHeat™ IH Series provides stable, controlled heating from 50°C to 300°C via a closed-loop circulation design, ensuring repeatable batch conditions and consistent heat transfer throughout each run.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eDesigned for production laboratories and pilot-scale facilities, this system addresses critical temperature variables that directly affect yield, viscosity, and reaction kinetics. An intuitive touchscreen HMI with real-time curve visualization allows operators to monitor performance across extended operations. Flow rates, port sizes, and utility connections can be customized to fit specific installation requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe QualiHeat™ IH Series functions as a complete circulating temperature control unit, delivering and sustaining accurate thermal fluid temperatures over a broad operating range. Its advanced control algorithms, combined with multiple temperature sensors, regulate both outlet fluid temperature and product-level thermal targets with high precision.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eA fully sealed circulation loop minimizes oil vapor release at higher temperatures and reduces moisture uptake during low-temperature operation. Programmable control enables stepped ramp and soak profiles, supporting method development and standardised operating procedures. RS485\/MODBUS RTU communication allows straightforward connection to plant supervisory systems or data acquisition platforms.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2 class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eIntegrated Heating Temperature Control System – QualiHeat™ IH Series Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eReactor Jacket Temperature Control (Glass or Stainless Steel Reactors)\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003ePrecise jacket temperature regulation supports synthesis, neutralization, and thermal conditioning processes. Accurate heat-up rates and steady-state stability directly influence conversion efficiency and selectivity in batch reactions.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eDistillation, Evaporation, and Solvent Processing\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eConsistent thermal delivery to reboilers and external heat exchangers helps stabilize boil-up rates, reducing variation between batches and improving solvent recovery outcomes.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003ePolymer \u0026amp; Resin Processing (Lab to Pilot Scale)\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThermal media control ensures stable conditions for viscosity-sensitive operations, including dissolution, blending, and curing studies. Minimizing temperature drift preserves rheological properties throughout development.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCrystallization \u0026amp; Precipitation Studies\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eProgrammed ramping and isothermal holding functions enhance reproducibility during nucleation and crystal growth phases, where temperature profiles play a critical role in final particle characteristics.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMaterial \u0026amp; Component Conditioning\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eReliable thermal circulation supports test fixtures and thermal blocks used in R\u0026amp;D validation, performance verification, and extended endurance trials.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eProcess Equipment Thermal Management\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eControlled heating fluid is delivered to external loops, heat exchangers, and manifolds, maintaining consistent flow and pressure for downstream equipment requiring stable thermal input.\u003c\/span\u003e\u003c\/p\u003e\n\u003cdiv class=\"ds-virtual-list-items _6f2c522\"\u003e\n\u003cdiv class=\"ds-virtual-list-visible-items\"\u003e\n\u003cdiv class=\"_4f9bf79 d7dc56a8 _43c05b5\" data-virtual-list-item-key=\"6\"\u003e\n\u003cdiv class=\"ds-message _63c77b1\"\u003e\n\u003cdiv class=\"ds-markdown ds-assistant-message-main-content\"\u003e\n\u003ch2 class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eIntegrated Heating Temperature Control System – QualiHeat™ IH Series Key Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eWide Heating Range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Covers 50°C to 300°C to accommodate diverse laboratory and pilot-scale thermal processing requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIntelligent Thermal Control\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Selectable setpoint modes allow regulation of either thermal media outlet temperature or direct material temperature, offering flexibility for various process needs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003e7‑Inch Touchscreen Interface\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Features real‑time temperature curve visualization and built‑in data recording, enabling quick performance checks and simplified reporting.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eProgrammable Temperature Profiles\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Multi‑step editing supports ramp, soak, and hold segments, ensuring consistent execution of standard operating procedures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClosed‑Loop Circulation Design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Minimizes oil vapor release at elevated temperatures and reduces moisture uptake during cooler operation, enhancing fluid longevity and system cleanliness.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRS485 \/ MODBUS RTU Communication\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Facilitates connection to data logging systems and external monitoring platforms for straightforward process supervision.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eComprehensive Safety Protections\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Includes self‑diagnostic functions and multiple interlock safeguards, covering overload, high pressure, overtemperature, low liquid level, and sensor fault conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eFlexible Model Configurations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Available in various sizes to match different flow rates, pressure requirements, and available floor or benchtop space.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ds-flex _0a3d93b\"\u003e\n\u003cdiv class=\"ds-flex _965abe9 _54866f7\"\u003e\n\u003ch2 class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eTheory and Method\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eClosed‑Loop Thermal Circulation\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eThe system heats a thermal transfer fluid (such as thermal oil or a compatible heat‑transfer medium) and circulates it through the external load—whether a reactor jacket, coil, or heat exchanger. A closed‑loop circulation design helps contain vapor and oil mist at elevated temperatures while limiting moisture ingress, resulting in more consistent thermal performance during extended operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eControl Strategy and Feedback Mechanism\u003c\/span\u003e\u003c\/strong\u003e\u003cbr\u003e\u003cspan class=\"\"\u003eIntelligent PID‑based control logic regulates thermal media temperature, delivering typical accuracy of ±0.5°C for standard heat‑transfer media. When the external sensor is correctly positioned and calibrated, reaction material control can achieve even tighter precision. Multiple PT100 feedback points—covering the unit outlet, medium temperature, and external material sensor—enable responsive adjustments during ramps and load fluctuations. Operators can set multi‑step programs to replicate heating profiles and holding segments with high repeatability, supporting reliable process outcomes across runs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2\u003eIntegrated Heating Temperature Control System – QualiHeat™ IH Series Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpec\u003c\/th\u003e\n\u003cth\u003eQualiHeat™ IH 25\u003c\/th\u003e\n\u003cth\u003eQualiHeat™ IH 35\u003c\/th\u003e\n\u003cth\u003eQualiHeat™ IH 55\u003c\/th\u003e\n\u003cth\u003eQualiHeat™ IH 75\u003c\/th\u003e\n\u003cth\u003eQualiHeat™ IH 100\u003c\/th\u003e\n\u003cth\u003eQualiHeat™ IH 150\u003c\/th\u003e\n\u003cth\u003eQualiHeat™ IH 250\u003c\/th\u003e\n\u003cth\u003eQualiHeat™ IH 380\u003c\/th\u003e\n\u003cth\u003eQualiHeat™ IH 600\u003c\/th\u003e\n\u003cth\u003eQualiHeat™ IH 950\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Power\u003c\/td\u003e\n\u003ctd\u003e2.5 kW\u003c\/td\u003e\n\u003ctd\u003e3.5 kW\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003ctd\u003e10.0 kW\u003c\/td\u003e\n\u003ctd\u003e15.0 kW\u003c\/td\u003e\n\u003ctd\u003e25.0 kW\u003c\/td\u003e\n\u003ctd\u003e38.0 kW\u003c\/td\u003e\n\u003ctd\u003e60.0 kW\u003c\/td\u003e\n\u003ctd\u003e95.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling @200°C\u003c\/td\u003e\n\u003ctd\u003e2.0 kW\u003c\/td\u003e\n\u003ctd\u003e3.0 kW\u003c\/td\u003e\n\u003ctd\u003e5.5 kW\u003c\/td\u003e\n\u003ctd\u003e7.5 kW\u003c\/td\u003e\n\u003ctd\u003e10.0 kW\u003c\/td\u003e\n\u003ctd\u003e15.0 kW\u003c\/td\u003e\n\u003ctd\u003e25.0 kW\u003c\/td\u003e\n\u003ctd\u003e38.0 kW\u003c\/td\u003e\n\u003ctd\u003e60.0 kW\u003c\/td\u003e\n\u003ctd\u003e95.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling @100°C\u003c\/td\u003e\n\u003ctd\u003e1.3 kW\u003c\/td\u003e\n\u003ctd\u003e2.0 kW\u003c\/td\u003e\n\u003ctd\u003e4.0 kW\u003c\/td\u003e\n\u003ctd\u003e5.0 kW\u003c\/td\u003e\n\u003ctd\u003e8.0 kW\u003c\/td\u003e\n\u003ctd\u003e12.0 kW\u003c\/td\u003e\n\u003ctd\u003e20.0 kW\u003c\/td\u003e\n\u003ctd\u003e30.0 kW\u003c\/td\u003e\n\u003ctd\u003e48.0 kW\u003c\/td\u003e\n\u003ctd\u003e76.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling @65°C\u003c\/td\u003e\n\u003ctd\u003e0.6 kW\u003c\/td\u003e\n\u003ctd\u003e1.0 kW\u003c\/td\u003e\n\u003ctd\u003e1.8 kW\u003c\/td\u003e\n\u003ctd\u003e2.2 kW\u003c\/td\u003e\n\u003ctd\u003e3.4 kW\u003c\/td\u003e\n\u003ctd\u003e5.0 kW\u003c\/td\u003e\n\u003ctd\u003e8.5 kW\u003c\/td\u003e\n\u003ctd\u003e12.0 kW\u003c\/td\u003e\n\u003ctd\u003e19.0 kW\u003c\/td\u003e\n\u003ctd\u003e30.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Flow (max)\u003c\/td\u003e\n\u003ctd\u003e10 L\/min\u003c\/td\u003e\n\u003ctd\u003e20 L\/min\u003c\/td\u003e\n\u003ctd\u003e35 L\/min\u003c\/td\u003e\n\u003ctd\u003e50 L\/min\u003c\/td\u003e\n\u003ctd\u003e50 L\/min\u003c\/td\u003e\n\u003ctd\u003e75 L\/min\u003c\/td\u003e\n\u003ctd\u003e110 L\/min\u003c\/td\u003e\n\u003ctd\u003e110 L\/min\u003c\/td\u003e\n\u003ctd\u003e250 L\/min\u003c\/td\u003e\n\u003ctd\u003e250 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePump Pressure\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1.5 bar\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e2.0 bar\u003c\/td\u003e\n\u003ctd colspan=\"5\"\u003e2.5 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooler Interface\u003c\/td\u003e\n\u003ctd colspan=\"10\"\u003eDN20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterface Size\u003c\/td\u003e\n\u003ctd\u003eDN15\u003c\/td\u003e\n\u003ctd colspan=\"4\"\u003eDN20\u003c\/td\u003e\n\u003ctd\u003eDN25\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eDN32\u003c\/td\u003e\n\u003ctd\u003eDN40\u003c\/td\u003e\n\u003ctd\u003eDN50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Dimensions (L×W×H, mm)\u003c\/td\u003e\n\u003ctd\u003e350 × 560 × 750\u003c\/td\u003e\n\u003ctd\u003e400 × 600 × 1050\u003c\/td\u003e\n\u003ctd\u003e400 × 600 × 1050\u003c\/td\u003e\n\u003ctd\u003e400 × 600 × 1050\u003c\/td\u003e\n\u003ctd\u003e400 × 600 × 1050\u003c\/td\u003e\n\u003ctd\u003e600 × 600 × 1250\u003c\/td\u003e\n\u003ctd\u003e600 × 600 × 1250\u003c\/td\u003e\n\u003ctd\u003e600 × 600 × 1250\u003c\/td\u003e\n\u003ctd\u003e1500 × 1000 × 1650\u003c\/td\u003e\n\u003ctd\u003e2050 × 1250 × 2050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e35 kg\u003c\/td\u003e\n\u003ctd\u003e65 kg\u003c\/td\u003e\n\u003ctd\u003e78 kg\u003c\/td\u003e\n\u003ctd\u003e80 kg\u003c\/td\u003e\n\u003ctd\u003e88 kg\u003c\/td\u003e\n\u003ctd\u003e100 kg\u003c\/td\u003e\n\u003ctd\u003e130 kg\u003c\/td\u003e\n\u003ctd\u003e240 kg\u003c\/td\u003e\n\u003ctd\u003e360 kg\u003c\/td\u003e\n\u003ctd\u003e480 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAC 220V, 50 Hz (110V is also available)\u003c\/td\u003e\n\u003ctd colspan=\"8\"\u003eAC 380V, 50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Power (max)\u003c\/td\u003e\n\u003ctd\u003e2.5 kW\u003c\/td\u003e\n\u003ctd\u003e3.5 kW\u003c\/td\u003e\n\u003ctd\u003e5.9 kW\u003c\/td\u003e\n\u003ctd\u003e8.3 kW\u003c\/td\u003e\n\u003ctd\u003e10.8 kW\u003c\/td\u003e\n\u003ctd\u003e15.7 kW\u003c\/td\u003e\n\u003ctd\u003e26.5 kW\u003c\/td\u003e\n\u003ctd\u003e39.5 kW\u003c\/td\u003e\n\u003ctd\u003e63.0 kW\u003c\/td\u003e\n\u003ctd\u003e98.0 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52667907375415,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/integrated-heating-temperature-control-system1647903821.webp?v=1784098305","url":"https:\/\/qualitest.us\/products\/integrated-heating-temperature-control-system","provider":"Qualitest USA LC","version":"1.0","type":"link"}