{"product_id":"high-pressure-ion-chromatograph-quali-ic-180h","title":"High Pressure Ion Chromatograph – Quali-IC™ 180H","description":"\u003ch2\u003eHigh Pressure Ion Chromatograph – Quali-IC™ 180H\u003c\/h2\u003e\n\u003cp\u003eThe Quali-IC™ 180H is a high-performance high-pressure ion chromatograph designed for precise, trace-level analysis of inorganic and organic ions under elevated pressure conditions.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e45 MPa High-Pressure Pumping System – Enables high-resolution separation and reproducible flow for complex sample matrices.\u003c\/li\u003e\n\u003cli\u003ePrecision Eluent Generation – Supports accurate isocratic and gradient elution with consistent concentration control.\u003c\/li\u003e\n\u003cli\u003eIntelligent System Monitoring – Continuous tracking of pressure, flow, and eluent status ensures safe, stable, and reliable operation.\u003c\/li\u003e\n\u003cli\u003eFlexible Method Capabilities – Supports both suppressed and non-suppressed ion chromatography, with optional two-dimensional chromatography configurations.\u003c\/li\u003e\n\u003cli\u003eOptimized for Complex Samples – Ideal for environmental, pharmaceutical, chemical, and industrial quality control applications requiring multi-component ion analysis.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThis system is engineered to provide exceptional accuracy, method flexibility, and long-term operational reliability for demanding analytical laboratories.\u003c\/p\u003e\n\u003ch2\u003eHigh Pressure Ion Chromatograph – Quali-IC™ 180H Applications\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eEnvironmental Analysis – Accurate determination of anions and cations in drinking water, wastewater, surface water, and other environmental samples at trace levels.\u003c\/li\u003e\n\u003cli\u003ePharmaceutical Quality Control – Measurement of counter-ions, impurities, and residual inorganic species in drug substances and formulations.\u003c\/li\u003e\n\u003cli\u003eChemical \u0026amp; Petrochemical Testing – Quantitative analysis of ionic species in process chemicals, reagents, and industrial raw materials.\u003c\/li\u003e\n\u003cli\u003eFood \u0026amp; Beverage Testing – Assessment of inorganic ions, organic acids, and additives for quality assurance and regulatory compliance.\u003c\/li\u003e\n\u003cli\u003ePower \u0026amp; Energy Industries – Monitoring of ionic contaminants in boiler water, cooling water, and other process streams.\u003c\/li\u003e\n\u003cli\u003eResearch \u0026amp; Advanced Analytics – Supports method development, gradient separations, and complex multi-ion profiling under high-pressure conditions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eStandards for High-Pressure Ion Chromatography (Quali-IC™ 180H)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Water and Environmental Monitoring\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM D2036 – Standard methods for analyzing common anions (chloride, sulfate, nitrate) in water.\u003c\/li\u003e\n\u003cli\u003eASTM D5794 – Determination of inorganic anions in atmospheric deposition samples.\u003c\/li\u003e\n\u003cli\u003eASTM D6832 – Analysis of anions and cations in water for industrial and power generation processes.\u003c\/li\u003e\n\u003cli\u003eASTM D6919 – IC methods for anion determination in water and wastewater.\u003c\/li\u003e\n\u003cli\u003eASTM D7359 – Trace anion measurement using suppressed conductivity IC.\u003c\/li\u003e\n\u003cli\u003eASTM D7994 – Modern IC techniques for inorganic anion analysis in water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 300.0 \/ 300.1 – IC methods for fluoride, chloride, nitrate, nitrite, and sulfate in drinking water and wastewater.\u003c\/li\u003e\n\u003cli\u003eUS EPA 302.0 – Determination of perchlorate in environmental water samples.\u003c\/li\u003e\n\u003cli\u003eUS EPA 314.0 – Low-concentration perchlorate detection in drinking water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 321.8 – Determination of bromate, bromide, chlorite, and chlorate in drinking water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 332.0 – Perchlorate analysis using suppressed conductivity IC.\u003c\/li\u003e\n\u003cli\u003eUS EPA 1636 – Measurement of inorganic anions in aqueous samples for environmental monitoring.\u003c\/li\u003e\n\u003cli\u003eUS EPA 6860 – Analysis of organic acids and inorganic anions in water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 9056 \/ 9058 – Protocols for inorganic anions in soils, solid waste, and aqueous extracts.\u003c\/li\u003e\n\u003cli\u003eDIN 38409-59 \u0026amp; EN 17813 – European standards for inorganic anion measurement in water and wastewater.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e2. Combustion Ion Chromatography (Halogens \u0026amp; Sulfur)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM D8247 – Analysis of halogens, sulfur, and fluorine in materials using combustion IC.\u003c\/li\u003e\n\u003cli\u003eUS EPA 1621 – Procedures for total organic fluorine, chlorine, and bromine determination.\u003c\/li\u003e\n\u003cli\u003eUOP 991 – Determination of trace halogens and sulfur in petroleum products via combustion IC.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3. Food, Beverage, and Nutritional Analysis (AOAC)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAOAC 2001.02 – Nitrate and nitrite determination in foods.\u003c\/li\u003e\n\u003cli\u003eAOAC 2012.20 – Inorganic anion analysis in infant formula and nutritional products.\u003c\/li\u003e\n\u003cli\u003eAOAC 995.13 – Chloride, nitrate, and sulfate determination in foods.\u003c\/li\u003e\n\u003cli\u003eAOAC 996.04 – Analysis of organic acids and inorganic ions in beverages and food products.\u003c\/li\u003e\n\u003cli\u003eAOAC 997.08 – Bromide and bromate detection in food and beverage matrices.\u003c\/li\u003e\n\u003cli\u003eAOAC 2000.11 – Anion determination in dairy and processed foods.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e4. Electronics and Industrial Compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 62321 – Halogen analysis in electrical and electronic materials for RoHS compliance.\u003c\/li\u003e\n\u003cli\u003eIPC-TM-650 2.3.28 – Measurement of ionic contamination on printed circuit boards.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese standards ensure that the Quali-IC™ 180H provides accurate, reliable, and regulatory-compliant ion chromatography results across multiple industries.\u003c\/p\u003e\n\u003ch2\u003eHigh Pressure Ion Chromatograph – Quali-IC™ 180H Key Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Pressure Pumping System\u003c\/strong\u003e\u003cbr\u003eDual-piston tandem pump capable of pressures up to 45 MPa (6600 psi) with low pulsation and high flow precision for stable and reproducible separations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Pressure Eluent Generator\u003c\/strong\u003e\u003cbr\u003eBuilt-in generator rated up to 42 MPa, supporting KOH, NaOH, LiOH, and MSA eluents with programmable gradients for automated and reproducible elution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdvanced Gradient Capability\u003c\/strong\u003e\u003cbr\u003eNine selectable gradient curves allow flexible separation strategies for complex ion mixtures and method optimization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntelligent System Protection\u003c\/strong\u003e\u003cbr\u003eIntegrated warning system detects over-pressure, low pressure, and liquid leakage, automatically protecting the instrument and preventing data loss.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eVoid-Volume-Free High-Pressure Connections\u003c\/strong\u003e\u003cbr\u003eTool-free connectors minimize dead volume, improving chromatographic efficiency and resolution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Definition Touchscreen Interface\u003c\/strong\u003e\u003cbr\u003eReal-time chromatogram display and system monitoring with one-touch stabilization and easy operational control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRemote Monitoring \u0026amp; Control\u003c\/strong\u003e\u003cbr\u003eMobile application support enables remote tracking of instrument status and adjustment of key parameters.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eColumn Thermostat with Heating \u0026amp; Cooling\u003c\/strong\u003e\u003cbr\u003eAccurate temperature regulation improves retention time stability and method reproducibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSuppressor Compatibility\u003c\/strong\u003e\u003cbr\u003eSupports both chemical suppressors and self-regenerating membrane suppressors for flexible detection options.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTwo-Dimensional Chromatography Ready\u003c\/strong\u003e\u003cbr\u003eValve switching with autosampler integration enables advanced multidimensional workflows for complex sample analysis.\u003c\/p\u003e\n\u003cp\u003eThis feature set positions the Quali-IC™ 180H as a high-resolution, high-pressure ion chromatography solution for environmental, pharmaceutical, food, chemical, and industrial applications requiring trace-level analysis and robust multi-ion separation.\u003c\/p\u003e\n\u003ch2\u003eHigh Pressure Ion Chromatograph – Quali-IC™ 180H Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" style=\"width:100%;\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQuali-IC™ 180H\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Type\u003c\/td\u003e\n\u003ctd\u003eHigh Pressure Ion Chromatograph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum System Pressure\u003c\/td\u003e\n\u003ctd\u003e45 MPa (6600 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEluent Generator Pressure Rating\u003c\/td\u003e\n\u003ctd\u003eUp to 42 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSupported Eluents\u003c\/td\u003e\n\u003ctd\u003eKOH, NaOH, LiOH, MSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEluent Concentration Range\u003c\/td\u003e\n\u003ctd\u003e0.1–100 mM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGradient Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.15%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Rate Range\u003c\/td\u003e\n\u003ctd\u003e0.001–15 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure Ripple\u003c\/td\u003e\n\u003ctd\u003e≤ 0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Accuracy \/ Precision\u003c\/td\u003e\n\u003ctd\u003e≤ 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDegassing System\u003c\/td\u003e\n\u003ctd\u003eIntegrated vacuum degasser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColumn Thermostat Range\u003c\/td\u003e\n\u003ctd\u003e15–80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuppressor Type\u003c\/td\u003e\n\u003ctd\u003eElectrolytic micro-membrane suppressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector\u003c\/td\u003e\n\u003ctd\u003eAuto-range conductivity detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003c\/td\u003e\n\u003ctd\u003e0–50,000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBaseline Noise\u003c\/td\u003e\n\u003ctd\u003e≤ 0.0005 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstrument Linearity\u003c\/td\u003e\n\u003ctd\u003e≥ 0.999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantitative Repeatability\u003c\/td\u003e\n\u003ctd\u003e≤ 0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e100–240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e120 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e380 × 520 × 620 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e35 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":51720559100215,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/high-pressure-ion-chromatograph.webp?v=1772044734","url":"https:\/\/qualitest.us\/products\/high-pressure-ion-chromatograph-quali-ic-180h","provider":"Qualitest USA LC","version":"1.0","type":"link"}