{"product_id":"combustion-ion-chromatograph-quali-ic-3200-online","title":"Combustion Ion Chromatograph – Quali-IC™ 3200 (Online)","description":"\u003ch2\u003eCombustion Ion Chromatograph – Quali-IC™ 3200 (Online)\u003c\/h2\u003e\n\u003cp\u003eThe Quali-IC™ 3200 (Online) is a high-performance combustion ion chromatograph designed for precise, online determination of halogens and sulfur in solid and liquid samples.\u003c\/p\u003e\n\u003cp\u003eBy combining automated high-temperature combustion, efficient gas absorption, and ion chromatographic detection, the system eliminates the need for manual oxygen-bomb combustion while providing exceptional repeatability, traceability, and analytical efficiency.\u003c\/p\u003e\n\u003cp\u003eKey features include a multi-zone programmable combustion furnace, automated sample handling, rapid Peltier cooling, and optional ion enrichment. These capabilities make the Quali-IC™ 3200 an ideal solution for laboratories and process environments that demand continuous, reliable elemental analysis.\u003c\/p\u003e\n\u003ch2\u003eCombustion Ion Chromatograph – Quali-IC™ 3200 (Online) Applications\u003c\/h2\u003e\n\u003cp\u003eThe Combustion Ion Chromatograph Quali-IC™ 3200 is widely applied for elemental analysis in the following areas:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePetrochemical \u0026amp; Energy Industries\u003c\/strong\u003e\u003cbr\u003eOnline determination of halogens and sulfur in fuels, oils, and petrochemical products to support quality control and regulatory compliance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnvironmental Testing\u003c\/strong\u003e\u003cbr\u003eMeasurement of trace halides and sulfur species in solid and liquid environmental samples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChemical Manufacturing\u003c\/strong\u003e\u003cbr\u003eProcess monitoring and impurity analysis in raw materials, intermediates, and finished chemical products.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePharmaceutical \u0026amp; Fine Chemicals\u003c\/strong\u003e\u003cbr\u003eElemental impurity testing to ensure product safety and maintain quality standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eResearch \u0026amp; Contract Laboratories\u003c\/strong\u003e\u003cbr\u003eHigh-precision elemental analysis for method development, validation, and routine testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandards for Ion Chromatography (IC) Analysis\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThis overview highlights key standardized methods for ion chromatography across water, environmental, food, pharmaceutical, and electronics applications, ensuring accurate, repeatable, and regulatory-compliant results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e1. Water and Environmental Analysis (ASTM \u0026amp; US EPA)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM D2036: Standard test for common anions (chloride, sulfate, nitrate) in water.\u003c\/li\u003e\n\u003cli\u003eASTM D5794: Determination of inorganic anions in atmospheric deposition (rain, snow) using IC.\u003c\/li\u003e\n\u003cli\u003eASTM D6832: IC analysis of anions and cations in water for industrial and power generation processes.\u003c\/li\u003e\n\u003cli\u003eASTM D6919: Methods for measuring anions in water and wastewater.\u003c\/li\u003e\n\u003cli\u003eASTM D7359: Procedures for trace anion measurement using suppressed conductivity IC.\u003c\/li\u003e\n\u003cli\u003eASTM D7994: Modern IC techniques for determining inorganic anions in water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 300.0 \/ 300.1: IC measurement of fluoride, chloride, nitrate, nitrite, and sulfate in drinking water and wastewater.\u003c\/li\u003e\n\u003cli\u003eUS EPA 302.0: Determination of perchlorate in environmental water samples.\u003c\/li\u003e\n\u003cli\u003eUS EPA 314.0: Low-level perchlorate detection in drinking water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 321.8: Analysis of bromate, bromide, chlorite, and chlorate in drinking water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 332.0: Perchlorate analysis in drinking water using suppressed conductivity IC.\u003c\/li\u003e\n\u003cli\u003eUS EPA 1636: Procedures for measuring inorganic anions in aqueous samples for environmental monitoring.\u003c\/li\u003e\n\u003cli\u003eUS EPA 6860: IC determination of both inorganic anions and organic acids in water.\u003c\/li\u003e\n\u003cli\u003eUS EPA 9056 \/ 9058: Methods for inorganic anions in solid waste, soils, and aqueous extracts.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e2. Combustion Ion Chromatography (Halogens and Sulfur)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eASTM D8247: Determination of halogens, sulfur, and fluorine in materials using combustion IC.\u003c\/li\u003e\n\u003cli\u003eUS EPA 1621: Procedures for total organic fluorine, chlorine, and bromine via combustion IC.\u003c\/li\u003e\n\u003cli\u003eUOP 991: Combustion IC methods for total halogens and sulfur in petroleum products.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e3. Food and Nutritional Products (AOAC)\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAOAC 2001.02: Nitrate and nitrite determination in foods.\u003c\/li\u003e\n\u003cli\u003eAOAC 2012.20: Inorganic anion analysis in infant formula and nutritional products.\u003c\/li\u003e\n\u003cli\u003eAOAC 995.13: Measurement of chloride, nitrate, and sulfate in foods.\u003c\/li\u003e\n\u003cli\u003eAOAC 996.04: Analysis of organic acids and inorganic ions in food and beverages.\u003c\/li\u003e\n\u003cli\u003eAOAC 997.08: Detection of bromide and bromate in food and beverage matrices.\u003c\/li\u003e\n\u003cli\u003eAOAC 2000.11: Anion determination in dairy and processed food products.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003e4. Industry and Compliance\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 62321: IC and other analytical methods for halogen determination in electrical\/electronic products (RoHS compliance).\u003c\/li\u003e\n\u003cli\u003eDIN 38409-59: IC procedures for measuring inorganic anions in water and wastewater.\u003c\/li\u003e\n\u003cli\u003eEN 17813: Determination of anions in water samples for European environmental compliance.\u003c\/li\u003e\n\u003cli\u003eIPC-TM-650 2.3.28: IC methods for measuring ionic contamination on printed circuit boards (PCBs).\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese standards provide validated frameworks for accurate and consistent IC analysis across environmental, industrial, food, and electronics applications.\u003c\/p\u003e\n\u003ch2\u003eCombustion Ion Chromatograph – Quali-IC™ 3200 (Online) Key Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eAutomated High-Temperature Combustion: Replaces manual oxygen-bomb methods with programmable, automated combustion for enhanced accuracy, repeatability, and safety.\u003c\/li\u003e\n\u003cli\u003eMulti-Zone Gradient Heating Furnace: Five independently controlled temperature zones (up to 1200 °C) prevent sample splashing and ensure complete combustion.\u003c\/li\u003e\n\u003cli\u003eHigh-Capacity Autosampler: 50-position boat injection system allows unattended processing of both solid and liquid samples.\u003c\/li\u003e\n\u003cli\u003eAutomatic Sample Retention for Traceability: Integrated 46-position retention system stores absorbed samples for retesting, auditing, and data verification.\u003c\/li\u003e\n\u003cli\u003eEfficient Oxygen Purging Design: Reverse oxygen scavenging returns unburned residues to the reaction zone for complete combustion.\u003c\/li\u003e\n\u003cli\u003eIon Enrichment Capability: Optional enrichment columns enhance sensitivity for low-concentration analytes.\u003c\/li\u003e\n\u003cli\u003ePeltier Cooling Technology: Rapid gas cooling to 5 °C improves absorption efficiency and measurement stability.\u003c\/li\u003e\n\u003cli\u003eParallel Processing Workflow: Next-sample combustion can begin while ion chromatography analysis is in progress, increasing throughput.\u003c\/li\u003e\n\u003cli\u003eSeamless IC Integration: Fully compatible with high-pressure ion chromatograph systems for precise conductivity detection.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCombustion Ion Chromatograph – Quali-IC™ 3200 (Online) Technical Specifications\u003c\/h2\u003e\n\u003ch3\u003eCombustion \u0026amp; Absorption Unit\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\" class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFurnace Temperature Range\u003c\/td\u003e\n\u003ctd\u003eAmbient to 1200 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Zones\u003c\/td\u003e\n\u003ctd\u003e5 independently controlled zones\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolid Sample Weight\u003c\/td\u003e\n\u003ctd\u003e0–200 mg (recommended 20–50 mg)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLiquid Sample Volume\u003c\/td\u003e\n\u003ctd\u003e0–200 µL (manual injection)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutosampler Capacity\u003c\/td\u003e\n\u003ctd\u003e50 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRetention Sampler Capacity\u003c\/td\u003e\n\u003ctd\u003e46 positions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen Purity\u003c\/td\u003e\n\u003ctd\u003e≥99.999%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen Flow Range\u003c\/td\u003e\n\u003ctd\u003e0–500 sccm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArgon Purity\u003c\/td\u003e\n\u003ctd\u003e≥99.999%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eArgon Flow Range\u003c\/td\u003e\n\u003ctd\u003e0–300 sccm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorption Volume\u003c\/td\u003e\n\u003ctd\u003e5–100 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInjection Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.01 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003ePeltier (minimum 5 °C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAverage Analysis Time\u003c\/td\u003e\n\u003ctd\u003e≤30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (Combustion Unit)\u003c\/td\u003e\n\u003ctd\u003e2060 × 550 × 770 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eIon Chromatograph (Optional Configuration)\u003c\/h3\u003e\n\u003ctable style=\"width: 100%;\" class=\"table\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eEluent Types\u003c\/td\u003e\n\u003ctd\u003eKOH \/ NaOH \/ LiOH \/ MSA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEluent Concentration Range\u003c\/td\u003e\n\u003ctd\u003e0.1–100 mM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Pump Pressure\u003c\/td\u003e\n\u003ctd\u003e42 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFlow Rate Range\u003c\/td\u003e\n\u003ctd\u003e0.001–12 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSuppressor Type\u003c\/td\u003e\n\u003ctd\u003eSelf-regenerating electrolytic suppressor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetector Type\u003c\/td\u003e\n\u003ctd\u003eAuto-range conductivity detector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Resolution\u003c\/td\u003e\n\u003ctd\u003e≤0.0020 nS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLinearity\u003c\/td\u003e\n\u003ctd\u003e≥0.999\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantitative Repeatability\u003c\/td\u003e\n\u003ctd\u003e≤0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Detection Limit\u003c\/td\u003e\n\u003ctd\u003eCl⁻ ≤0.0003 µg\/mL; Li⁺ ≤0.0001 µg\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e150 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIC Dimensions\u003c\/td\u003e\n\u003ctd\u003e360 × 510 × 610 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e35.5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":51720263991607,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/combustion-ion-chromatograph-qua.webp?v=1772041934","url":"https:\/\/qualitest.us\/products\/combustion-ion-chromatograph-quali-ic-3200-online","provider":"Qualitest USA LC","version":"1.0","type":"link"}