{"product_id":"automatic-vicat-needle-apparatus-single-station-with-paper-recording-device-model-vicat306","title":"Automatic Vicat Needle Apparatus – Single Station with Paper Recording Device - Model Vicat306","description":"\u003ch2\u003eAutomatic Vicat Needle Apparatus – Single Station with Paper Recording Device - Model Vicat306\u003c\/h2\u003e\n\u003cp\u003eThe Vicat306 Automatic Single Station Vicat Needle Apparatus is an entry-level testing instrument designed for determining the setting time of cement. It measures the initial and final setting stages by evaluating the penetration behavior of a 1.13 mm steel needle into a cement paste sample under specified test conditions.\u003c\/p\u003e\n\u003cp\u003eThe Vicat306 automatically performs the penetration test and records the results using an integrated paper recording device (drum). Its single-station configuration provides a practical solution for laboratories performing routine cement setting time tests.\u003c\/p\u003e\n\u003ch2\u003eCement Setting Time Testing\u003c\/h2\u003e\n\u003cp\u003eThe Vicat setting time test determines the initial and final setting times of cement paste by measuring the penetration of a steel needle under specified test conditions. The Automatic Vicat Needle Apparatus Single Station with Paper Recording Device, Model Vicat306, automates the penetration sequence and records test results on a paper recording drum.\u003c\/p\u003e\n\u003cp\u003eUsing the standard 1.13 mm diameter × 57 mm long needle, the Vicat306 provides a consistent approach to monitoring changes in cement paste penetration resistance during the setting process. The automated operation helps reduce the need for continuous manual timing and recording throughout the test.\u003c\/p\u003e\n\u003ch2\u003eStandards \u0026amp; Testing Methods\u003c\/h2\u003e\n\u003cp\u003eCement setting time testing is performed according to established international standards that define the required test conditions, apparatus configuration, and measurement procedures. The Vicat306 is designed for cement setting time testing in accordance with applicable requirements associated with ASTM C187, ASTM C191, BS 4550, DIN 1164, and EN 196.\u003c\/p\u003e\n\u003ch3\u003eManual Testing Method\u003c\/h3\u003e\n\u003cp\u003eThe traditional Vicat test requires an operator to control the needle penetration sequence, observe the measurement, record the readings, and repeat the process at specified intervals. This method requires regular operator attention throughout the test.\u003c\/p\u003e\n\u003ch3\u003eAutomatic Testing Method\u003c\/h3\u003e\n\u003cp\u003eAn Automatic Vicat Needle Apparatus performs the penetration sequence at controlled intervals, reducing repetitive manual operations during testing. The Vicat306 maintains the single-station test arrangement while automatically carrying out the penetration cycle and recording the results on a paper drum.\u003c\/p\u003e\n\u003ch2\u003eAutomated Test Operation\u003c\/h2\u003e\n\u003cp\u003eThe Vicat306 Automatic Single Station Vicat Needle Apparatus combines controlled penetration, timed testing intervals, and paper chart recording in a single laboratory instrument.\u003c\/p\u003e\n\u003ch3\u003eControlled Penetration Cycle\u003c\/h3\u003e\n\u003cp\u003eThe apparatus provides a controlled mechanical penetration sequence for testing cement paste. The standard 1.13 mm diameter × 57 mm length needle is used for penetration measurements, while the supplied final-set needle with special footing supports final setting determination.\u003c\/p\u003e\n\u003cp\u003eThe standard configuration also includes a Vicat mould measuring 70\/80 mm diameter × 40 mm and a sample container (water bath) according to EN 196-3.\u003c\/p\u003e\n\u003ch3\u003ePaper Drum Recording\u003c\/h3\u003e\n\u003cp\u003eThe Vicat306 records test results using an integrated paper recording device (drum). The rotating drum provides a physical record of the penetration measurements during the cement setting time test, allowing laboratory personnel to review the recorded test progression after completion.\u003c\/p\u003e\n\u003ch3\u003eNeedle Cleaning\u003c\/h3\u003e\n\u003cp\u003eConsistent needle condition is important during repeated penetration measurements. The Vicat306 includes a cleaning strip for cleaning the needle during the testing process. This helps maintain the needle surface for subsequent penetration measurements.\u003c\/p\u003e\n\u003ch3\u003eAdjustable Testing Intervals\u003c\/h3\u003e\n\u003cp\u003eThe apparatus features a delay timer adjustable from 30 seconds to a maximum of 6 hours. This allows laboratory personnel to set the required interval between penetration measurements according to the testing procedure.\u003c\/p\u003e\n\u003cp\u003eThe adjustable timing function makes the Vicat306 suitable for routine cement setting time testing where repeated measurements are required over a defined testing period.\u003c\/p\u003e\n\u003ch2\u003eVicat306 Standard Configuration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMain Unit\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eNeedle, 1.13 mm diameter × 57 mm length\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFinal-set needle with special footing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVicat mould, 70\/80 mm diameter × 40 mm\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSample container (water bath) according to EN 196-3\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlotting paper, 500 sheets\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCleaning strip\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTweezer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTee wrench\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDelay timer from 30 seconds to a maximum of 6 hours\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAutomatic Vicat Needle Apparatus - Model Vicat306 Technical Specifications:\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003cbr\u003eW x D x H)\u003c\/td\u003e\n\u003ctd\u003e280 x 430 x 465 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e17.2 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e110 - 230 V \/ 50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptions\/Accessories\u003c\/td\u003e\n\u003ctd\u003eCleaning Strip for Needle Cleaning, Vicat Mould EN 196, Initial Set Needle, Final Set Needle, Plotting Paper, Extra Recording Pen, Sample Container, Glass Base Plate 133 mm dia., Vicat Penetration Needle 1.0mm dia., Glass base plate 120 mm dia., Vicat Mould (Conical hard plastic ring) ASTM C187-191, Initial Set Needle ASTM C187-191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":53066862231863,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/automatic-vicat-needle-apparatus_3.webp?v=1790694917","url":"https:\/\/qualitest.us\/products\/automatic-vicat-needle-apparatus-single-station-with-paper-recording-device-model-vicat306","provider":"Qualitest USA LC","version":"1.0","type":"link"}