{"product_id":"thermogravimetric-analyzer-tga-qualitga-1000c","title":"Thermogravimetric Analyzer TGA - QualiTGA-1000C","description":"\u003ch2\u003eThermogravimetric Analyzer TGA - QualiTGA-1000C\u003c\/h2\u003e\n\u003cp\u003eThe TGA Thermogravimetric Analyzer is a high-performance instrument engineered for accurate thermal analysis. It performs thermogravimetric testing by monitoring changes in a sample’s mass as temperature varies. Through detailed TGA data analysis, it delivers valuable insights into material composition, thermal stability, and decomposition behavior, making it essential for research and quality evaluation across diverse materials.\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003eThermogravimetric Analyzer TGA – QualiTGA™ 1000C is a compact, high-precision thermal analysis system designed for reliable and efficient performance. It operates on the electromagnetic force balance principle, delivering highly accurate mass change measurements during heating processes.\u003c\/p\u003e\n\u003cp\u003eEquipped with an industrial-grade wide touchscreen interface and Gigabit Ethernet connectivity, the system ensures smooth operation and seamless data communication for modern laboratory environments.\u003c\/p\u003e\n\u003cp\u003eThe advanced furnace sealing system provides full environmental isolation, while the integrated water bath insulation helps maintain stable and uniform thermal conditions throughout analysis. Its improved mechanical design includes fixed, flexible, and replaceable sample support rods, enabling smooth handling and consistent testing performance.\u003c\/p\u003e\n\u003cp\u003eBuilt with advanced engineering, QualiTGA™ 1000C features a fixed furnace body structure that removes the need for lifting mechanisms, improving safety and operational convenience. Users can precisely control heating and cooling rates based on analytical requirements. In addition, the detachable sample holder simplifies replacement, cleaning, and maintenance, even when handling contaminated samples, ensuring long-term reliability and ease of use.\u003cbr\u003e\u003c\/p\u003e\n\u003ch2\u003eFeatures of Thermogravimetric Analyzer TGA – QualiTGA™ 1000C\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIndustrial-grade wide touchscreen interface for smooth and intuitive operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eGigabit Ethernet communication interface for fast and stable data transfer\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCompact furnace design optimized for efficient thermal performance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eElectromagnetic force balance principle for high-precision mass measurement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWater bath insulation system ensuring stable and uniform thermal conditions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdvanced furnace sealing system providing complete environmental protection\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes standard samples and reference spectra for calibration and validation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eImproved installation system with mechanically fixed, flexible, and replaceable sample support rods\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntelligent software with automatic display adjustment based on screen size\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUser-friendly self-programming capability for customized testing requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated fixed furnace body design removes lifting requirements, enhancing safety and ease of use\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDetachable sample holder for convenient cleaning, replacement, and maintenance\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTechnical Specifications of Thermogravimetric Analyzer TGA - QualiTGA-1000C\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eModel\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eQualiTGA-1000C\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eTemperature range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eRT~1000 ℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eTemperature resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e0.01℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eTemperature fluctuations\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e± 0.1℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eHeating rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e0.1 ～ 80℃\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eCooling rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e0.1 ℃\/min -30 ℃\/min (constant cooling above 100 ℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eConstant temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eRoom temperature -1000 ℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eTemperature control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003ePID temperature regulation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eScale measurement range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e0.01mg-2g (optional ranges of 10g, 50g, etc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eThermogravimetric resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e0.01mg (optional resolutions of 1ug, 0.1ug, etc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eIncubation time\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e0-300min arbitrary setting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eGas control\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eNitrogen and oxygen gas control (instrument automatic switching)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eAC220V 50Hz or 60H or customized (110V also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eLink Method\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eGigabit Ethernet communication\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eCrucible size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e10mm*6mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003eBare metal size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e90cm * 55cm * 52cm, weight 90Kg, packaging weight 110kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e\u003cstrong\u003ePower\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e1000W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52183722590519,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/thermogravimetric-analyzer-tga-qualitga-1000c1245728331.webp?v=1779462928","url":"https:\/\/qualitest.us\/fr\/products\/thermogravimetric-analyzer-tga-qualitga-1000c","provider":"Qualitest USA LC","version":"1.0","type":"link"}