{"product_id":"smart-probe-ultrasonicator","title":"Smart Probe Ultrasonicator","description":"\u003ch2\u003eSmart Probe Ultrasonicator – QualiUltra™ Smart Series\u003c\/h2\u003e\n\u003cp\u003eThe QualiUltra™ Smart Series Probe Ultrasonicator delivers high-intensity ultrasonic cavitation for efficient cell lysis, tissue disruption, and uniform liquid homogenization with precise energy regulation. Advanced smart control capabilities ensure steady operation through automatic frequency tracking, impedance matching, and integrated safeguards against overload and excessive temperature.\u003c\/p\u003e\n\u003cp\u003eThis series is developed for laboratories that require highly repeatable protocols, secure parameter storage, and streamlined operating procedures. A noise-reducing enclosure combined with automated probe lifting and system enhancements supports safer handling during processing while maintaining a clean and organized workspace.\u003c\/p\u003e\n\u003cp\u003eThe QualiUltra™ Smart Series provides a scalable Probe Ultrasonicator platform suitable for both small and large sample volumes. Output power is adjustable across models, with a standard operating range of 20–25 kHz to maintain consistent cavitation performance. Built-in time and temperature regulation helps preserve method accuracy during routine workflows.\u003c\/p\u003e\n\u003cp\u003eA smart control architecture ensures stable and reliable operation, featuring automatic frequency tracking, system diagnostics, alert functions, and protected program storage. Connectivity options enable integration with a main unit computer for centralized control and remote printing support within lab networks.\u003c\/p\u003e\n\u003ch2\u003eSmart Probe Ultrasonicator – QualiUltra™ Smart Series Applications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCell lysis and biomolecule extraction\u003c\/strong\u003e\u003cbr\u003eUltrasonic cavitation disrupts cell membranes to support extraction of DNA, RNA, and proteins. It is widely used in sample preparation involving bacteria, viruses, and spores where strong mechanical disruption is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDNA\/RNA fragmentation and size control\u003c\/strong\u003e\u003cbr\u003ePrecisely managed sonication reduces nucleic acid fragment length for workflows requiring defined size ranges. Adjustable pulse modes and processing duration allow fine control of energy input while limiting excessive heat generation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChromatin immunoprecipitation (ChIP) preparation\u003c\/strong\u003e\u003cbr\u003eProbe-based ultrasonication supports chromatin fragmentation steps used in ChIP workflows. Consistent energy delivery improves reproducibility, while temperature monitoring and safety functions help maintain stable processing conditions during extended runs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNanomaterial dispersion and deagglomeration\u003c\/strong\u003e\u003cbr\u003eThe system facilitates dispersion and breakup of clustered nanomaterials such as carbon nanotubes and graphene, producing more uniform suspensions. This improves reliability in materials research, chemical studies, and formulation development.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEmulsification and homogenization processes\u003c\/strong\u003e\u003cbr\u003eHigh-intensity cavitation supports emulsification, homogenization, and particle size reduction in chemical and formulation applications. Stable power output and consistent frequency behavior enhance method repeatability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSoil, rock, and particulate sample preparation\u003c\/strong\u003e\u003cbr\u003eProbe ultrasonication assists in homogenizing soil, rock, and particulate samples for analytical workflows where uniform dispersion is required. It is also used across geological, marine, environmental, and biomedical sample preparation applications.\u003c\/p\u003e\n\u003ch2\u003eCompliance Standards\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 61010-1 — Safety requirements for electrical equipment used in measurement, control, and laboratory environments, ensuring protection against electrical, mechanical, and thermal hazards.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIEC 61326-1 — Electromagnetic compatibility (EMC) standard covering emission limits and immunity performance for laboratory and analytical instruments, supporting stable operation in controlled environments.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eISO 20427 — Standardized methodology for ultrasonic dispersion procedures using probe-type sonication systems, providing guidance for consistent and reproducible processing results.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSmart Probe Ultrasonicator – QualiUltra™ Smart Series Key Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSmart control architecture for stable output\u003c\/strong\u003e\u003cbr\u003eA microcontroller-based system using DSP + ARM processing is described to support steady operation, precise control, and reliable data handling during ultrasonic processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic frequency tracking and impedance matching\u003c\/strong\u003e\u003cbr\u003eReal-time frequency adjustment and impedance adaptation help maintain consistent cavitation performance even when sample conditions change.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePulse and continuous operation for thermal control\u003c\/strong\u003e\u003cbr\u003eMultiple operating modes, including pulse and continuous sonication, allow users to manage energy input and reduce temperature rise in sensitive samples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLarge touch display with real-time parameter view\u003c\/strong\u003e\u003cbr\u003eA 7-inch TFT touchscreen provides clear access to key settings such as temperature, power\/amplitude, and pulse configuration, enabling direct on-screen control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecure method storage for reproducible workflows\u003c\/strong\u003e\u003cbr\u003eUp to 20 method profiles can be saved, with password-based access control to support standardized and secure laboratory operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in diagnostics and protection systems\u003c\/strong\u003e\u003cbr\u003eSelf-check functions and safety alerts help monitor system status, with protections for overload and excessive temperature clearly indicated during operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnectivity for laboratory integration\u003c\/strong\u003e\u003cbr\u003eRJ-45 and wireless communication options support main unit system connectivity, enabling centralized control and remote printing within lab networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSound-reducing enclosure with integrated handling features\u003c\/strong\u003e\u003cbr\u003eAn enclosed chamber design includes illumination, sterilization function, automatic probe lifting, and door-lock safety features to support controlled and organized operation.\u003c\/p\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003eProbe-based ultrasonic systems produce alternating pressure waves in liquid media, leading to the formation of cavitation bubbles. The collapse of these bubbles generates localized shear forces and micro-jets that facilitate cell disruption, particle dispersion, and enhanced mixing efficiency. Consistent performance is achieved through stable energy delivery, supported by automatic frequency tracking and impedance matching to maintain uniform cavitation behavior.\u003c\/p\u003e\n\u003cp\u003eA standard workflow begins with selecting an appropriate probe tip size based on sample volume and viscosity. Next, define processing parameters such as target power level, pulse or continuous operation mode, and total processing duration. Temperature should be monitored throughout the cycle to avoid thermal impact on sensitive materials. For temperature-sensitive applications, a cooling system or ice bath can be used to maintain tighter thermal control. After completion, the probe should be cleaned thoroughly, and the optimized settings can be saved as a method to ensure consistent repetition in future runs.\u003c\/p\u003e\n\u003ch2\u003eSmart Probe Ultrasonicator – QualiUltra™ Smart Series Technical Specification\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ Smart 650\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ Smart 950\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ Smart 1200\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower range (adjustable)\u003c\/td\u003e\n\u003ctd\u003e5–650 W\u003c\/td\u003e\n\u003ctd\u003e5–950 W\u003c\/td\u003e\n\u003ctd\u003e5–1200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e20–25 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing volume\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.2–500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime range\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0–999 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature control\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0–100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlerts\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eTemperature, time, failure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoundproof box\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eInternal electric lifting device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoundproof box size\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e350 × 345 × 545 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard probe (horn)\u003c\/td\u003e\n\u003ctd\u003eØ6 mm\u003c\/td\u003e\n\u003ctd\u003eØ6 mm\u003c\/td\u003e\n\u003ctd\u003eØ20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional probe tips\u003c\/td\u003e\n\u003ctd\u003eØ2, Ø3, Ø10, Ø12 mm\u003c\/td\u003e\n\u003ctd\u003eØ2, Ø3, Ø10, Ø12, Ø15 mm\u003c\/td\u003e\n\u003ctd\u003eØ15, Ø25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional cooling cup\u003c\/td\u003e\n\u003ctd\u003e30 mL, 100 mL, 400 mL\u003c\/td\u003e\n\u003ctd\u003e30 mL, 100 mL, 400 mL\u003c\/td\u003e\n\u003ctd\u003e100 mL, 400 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard configuration\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eMain Unit + transducer + probe + software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52072180547895,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/smart-probe-ultrasonicator1852959175.webp?v=1777590404","url":"https:\/\/qualitest.us\/fr\/products\/smart-probe-ultrasonicator","provider":"Qualitest USA LC","version":"1.0","type":"link"}