{"product_id":"semi-automatic-melt-flow-indexer-mfi","title":"Semi Automatic Melt Flow Indexer (MFI)","description":"\u003ch2\u003eSemi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA\u003c\/h2\u003e\n\u003cp\u003eQualiFi™ 6000SA is a semi-automatic, safety-enhanced melt flow indexer developed for B2B plastics testing laboratories that require higher throughput, reduced operator involvement, and improved safety compared to a standard automatic weight-loading instrument. It measures MFR across 0.1–100 g\/10 min and MVR up to 3000 cm³\/10 min at temperatures from 50 to 450 °C. This melt flow index tester integrates pneumatic material compaction, pneumatic residual extrusion, pneumatic barrel cleaning, and a weight fall-prevention guard within the QualiFi™ Series platform—delivering a safer, faster, and more repeatable testing workflow than the QualiFi™ 5000. CE certified and CNAS proficiency-verified, the QualiFi™ 6000SA is a reliable upgrade melt flow index tester for high-frequency QC and production monitoring environments across North America.\u003c\/p\u003e\n\u003cp\u003eThe QualiFi™ 6000SA is a pneumatic-assisted semi-automatic melt flow indexer designed for plastics testing environments where test throughput, operator safety, and measurement repeatability are higher priorities than compact benchtop design. Built on the QualiFi™ Series platform, it retains the core measurement precision, dual PID temperature control, and software capabilities of the QualiFi™ 5000 while adding pneumatic-assisted functions and a weight fall-prevention guard that reduce manual intervention, minimize human error, and improve operator safety during frequent testing cycles.\u003c\/p\u003e\n\u003cp\u003eThe weight is manually selected by the operator but automatically lifted and lowered without physical handling once selected, similar to the QualiFi™ 5000 lifting mechanism. A weight fall-prevention guard is added in the 6000SA, physically securing the weight stack and reducing the risk of uncontrolled weight movement during operation. Material compaction is performed pneumatically with adjustable force and time (10–50 kg), removing variability from manual compaction and improving repeatability for high-viscosity materials.\u003c\/p\u003e\n\u003cp\u003ePneumatic residual material extrusion uses adjustable pneumatic load (10–50 kg) to remove remaining polymer from the barrel after each test, reducing between-test cleaning time and effort. Pneumatic barrel cleaning completes the post-test cycle using compressed air to clear internal residue, eliminating the need for manual rod cleaning typically required on standard melt flow index testers. These three pneumatic functions reduce total turnaround time between tests, making the QualiFi™ 6000SA suitable for high-frequency QC environments where multiple tests are performed per shift.\u003c\/p\u003e\n\u003cp\u003eAll core QualiFi™ Series platform features are retained, including the 10.1-inch HD touch screen, 50–450 °C dual PID temperature control, ±0.2 °C temperature accuracy, 0.002 mm piston displacement resolution, 8 customizable test plans, 5,000-group USB data storage with DMS software, optional PC two-way control, and multi-language interface support. The floor-standing design (580×480×1450 mm) accommodates the pneumatic assembly and weight guard system and requires a compressed air supply above 0.6 MPa.\u003c\/p\u003e\n\u003ch2\u003eSemi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA Applications\u003c\/h2\u003e\n\u003cp\u003eThe QualiFi™ 6000SA melt flow indexer is designed for B2B plastics testing environments where test frequency, operational safety, and throughput are key requirements, and where variations from manual compaction in a standard melt flow index tester can impact result consistency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Frequency Production QC:\u003c\/strong\u003e\u003cbr\u003eIncoming and outgoing inspection of polyolefin, engineering plastic, and specialty resin batches at high testing volumes. Pneumatic cleaning and residual extrusion reduce between-test downtime and improve workflow efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Viscosity Polymer Testing:\u003c\/strong\u003e\u003cbr\u003eMFR\/MVR evaluation of materials such as nylon, polycarbonate, fluoroplastics, and other engineering resins requiring stable and repeatable compaction force. Pneumatic compaction eliminates operator-dependent variation associated with manual loading.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePetrochemical \u0026amp; Compounding Lines:\u003c\/strong\u003e\u003cbr\u003eProcess control and product validation of polymer melts and compound formulations that require consistent test conditions and fast changeover between samples without dismantling the barrel assembly.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePlastics Manufacturing Operations:\u003c\/strong\u003e\u003cbr\u003eBatch qualification, supplier verification, and extrusion or injection molding process monitoring based on defined MFR limits in accordance with ISO 1133 and ASTM D1238 standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRegulated \u0026amp; Accredited Laboratories:\u003c\/strong\u003e\u003cbr\u003eThird-party testing, certification, and inspection workflows requiring traceable data export, user access control, and CNAS-verified measurement consistency across repeated test cycles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAcademic \u0026amp; Applied Research:\u003c\/strong\u003e\u003cbr\u003ePolymer behavior analysis, blend formulation studies, and comparative melt flow testing across material grades with detailed data logging and reproducible test conditions.\u003c\/p\u003e\n\u003ch2\u003eStandards\u003c\/h2\u003e\n\u003cp\u003eThe QualiFi™ 6000SA melt flow indexer is designed and verified in accordance with internationally recognized standards for thermoplastic melt flow rate testing, laboratory measurement accuracy, and equipment safety.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eISO 1133-1:2011 — Plastics: Determination of the melt mass-flow rate (MFR) and melt volume-flow rate (MVR) of thermoplastics — Part 1: Standard procedure\u003c\/li\u003e\n\u003cli\u003eISO 1133-2:2011 — Plastics: Determination of MFR and MVR of thermoplastics — Part 2: Method for materials sensitive to time-temperature history and\/or moisture\u003c\/li\u003e\n\u003cli\u003eASTM D1238 — Standard Test Method for Melt Flow Rates of Thermoplastics by Extrusion Plastometer (Procedures A and B)\u003c\/li\u003e\n\u003cli\u003eIEC 61010-1 \/ EN 61010-1:2010+A1:2019 — Safety requirements for electrical equipment used in measurement, control, and laboratory applications (CE certified)\u003c\/li\u003e\n\u003cli\u003eEN 61326-1:2013 — Electrical equipment for measurement, control, and laboratory use: EMC requirements (CE certified)\u003c\/li\u003e\n\u003cli\u003eISO 9001:2015 — Quality management system standard applied to laboratory instrument manufacturing processes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCertifications and Proficiency Verification\u003c\/h2\u003e\n\u003cp\u003eThe QualiFi™ 6000SA is built on the validated QualiFi™ Series platform and maintains the same core compliance framework across the product family, including CE certification and repeated CNAS proficiency testing validation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCE Certification:\u003c\/strong\u003e\u003cbr\u003eComplies with EN 61010-1:2010+A1:2019 (Low Voltage Directive) and EN 61326-1:2013 (EMC requirements), confirmed through ECM Certificate of Compliance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCNAS Proficiency Testing:\u003c\/strong\u003e\u003cbr\u003eVerified through consecutive CNAS inter-laboratory proficiency comparisons, with all results within acceptable limits. Reported Z-scores remain in the range of −0.07 to +0.11 across all evaluation rounds.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTechnical Patents:\u003c\/strong\u003e\u003cbr\u003eThe QualiFi™ Series includes multiple registered technical patents covering core measurement systems, thermal control architecture, and structural design innovations.\u003c\/p\u003e\n\u003ch2\u003eSemi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA Key Features\u003cbr\u003e\n\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/qualifitm-6000-1298853698_1.webp?v=1776683421\" alt=\"\"\u003e\u003c\/p\u003e\n\u003ch3\u003ePneumatic Systems and Safety Step-up from QualiFi™ 5000\u003c\/h3\u003e\n\u003cp\u003eThe QualiFi™ 6000SA integrates enhanced pneumatic systems over the QualiFi™ 5000, improving consistency, efficiency, and operator safety in melt flow index testing workflows.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Material Compaction (10–50 kg adjustable):\u003c\/strong\u003e\u003cbr\u003eProvides controlled compaction force and timing, eliminating operator-dependent variation during sample preparation and improving run-to-run MFR\/MVR repeatability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Residual Material Extrusion (10–50 kg adjustable):\u003c\/strong\u003e\u003cbr\u003eUses controlled pneumatic load to remove remaining polymer from the barrel after testing, reducing reliance on manual rod operation and accelerating post-test processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Barrel Cleaning:\u003c\/strong\u003e\u003cbr\u003eApplies compressed air to clear residual material from the barrel interior, significantly reducing between-test preparation time and improving efficiency in high-frequency testing environments.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/qualifitm-6000sa-2-868307007_1.webp?v=1776683419\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight Fall-Prevention Guard:\u003c\/strong\u003e\u003cbr\u003eA mechanical safety system that physically secures the weight stack, preventing uncontrolled descent during setup, weight changes, or loading operations. This adds an extra layer of operational safety compared to the QualiFi™ 5000.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePreloading System (Dual Mode):\u003c\/strong\u003e\u003cbr\u003eSupports two controlled loading ranges to ensure accurate and repeatable test conditions across different materials:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCalibration weight load: 0.325–21.6 kg\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdditional load: 10–50 kg\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eBoth modes allow adjustable positioning to support precise reproduction of test parameters for varied material types.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePreheating Function:\u003c\/strong\u003e\u003cbr\u003eSupports both no-load and loaded preheating operation modes, enabling flexible preparation protocols based on material characteristics and specific testing requirements.\u003c\/p\u003e\n\u003ch3\u003eCore Measurement Platform\u003c\/h3\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/qualifitm-6000sa-1-1322974009_1.webp?v=1776683418\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eCore components including the oven, die, and piston are manufactured from low-thermal-expansion, corrosion-resistant alloy materials that comply with ISO 1133 dimensional stability and hardness requirements, ensuring long-term measurement accuracy under high-temperature conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Control System:\u003c\/strong\u003e\u003cbr\u003eOperating range: 50–450 °C\u003cbr\u003eTemperature resolution: 0.01 °C\u003cbr\u003eMaximum indication error: ≤0.2 °C\u003cbr\u003eFluctuation: ≤±0.2 °C\u003cbr\u003eTemperature gradient: ≤±0.1 °C\u003c\/p\u003e\n\u003cp\u003eThe system uses dual PID temperature control for rapid, overshoot-free heating and stable regulation. After material loading, temperature recovery time is typically ≤2 minutes, supporting continuous high-frequency testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurement Precision System:\u003c\/strong\u003e\u003cbr\u003ePiston displacement resolution: 0.002 mm\u003cbr\u003eMaximum indication error: ±0.02 mm\u003cbr\u003eTimer resolution: 0.001 s\u003c\/p\u003e\n\u003cp\u003eThese parameters support high-accuracy MFR\/MVR determination with stable time and displacement tracking during extrusion testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtended Flow Measurement Capability:\u003c\/strong\u003e\u003cbr\u003eMaximum measurable flow rate reaches up to 3000 cm³\/10 min, extended through a lever-operated die plug device for broader material applicability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight Handling and Automation:\u003c\/strong\u003e\u003cbr\u003eThe system enables automatic lifting and lowering of weights without manual handling during operation. Weight selection is performed manually prior to test initiation, supporting controlled and repeatable loading conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUser Interface and Observation System:\u003c\/strong\u003e\u003cbr\u003eA 10.1-inch HD full-color touchscreen is integrated at the front of the oven for direct control and monitoring. A variable-angle metal observation mirror with 15° adjustable viewing and a shatter-resistant surface allows safe visual inspection during operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSafety Structure:\u003c\/strong\u003e\u003cbr\u003eA movable protective cover shields the area between the furnace body and loading mechanism during high-temperature operation, improving operator safety and reducing exposure to heated components.\u003c\/p\u003e\n\u003ch3\u003eSoftware and Data Management\u003c\/h3\u003e\n\u003cp\u003eThe system supports Mass Method (A), Volume Method A, and Volume Method B testing, with automatic identification of ISO\/ASTM test intervals and automated test initiation to streamline workflow execution.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTest Configuration:\u003c\/strong\u003e\u003cbr\u003eProvides 8 customizable test plans for direct selection before testing, reducing repetitive parameter setup in routine laboratory operations and improving workflow efficiency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReal-Time Monitoring:\u003c\/strong\u003e\u003cbr\u003eDisplays temperature–time and MVR–number curves in real time on the screen, enabling immediate evaluation of thermal stability and result consistency during testing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Storage and Reporting:\u003c\/strong\u003e\u003cbr\u003eUSB flash drive storage supports up to 5,000 test result groups. Integrated DMS data management software enables data export and structured report generation for laboratory documentation and traceability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePC Integration and Connectivity:\u003c\/strong\u003e\u003cbr\u003eOptional PC software allows two-way system control and remote database upload, supporting centralized data management in multi-instrument environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMulti-Language Interface:\u003c\/strong\u003e\u003cbr\u003eSupports English, French, German, Italian, Russian, and Chinese for flexible international laboratory use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUser Access Control:\u003c\/strong\u003e\u003cbr\u003eIncludes user authority management with configurable role-based permissions to safeguard measurement data integrity and prevent unauthorized parameter modifications in shared laboratory settings.\u003c\/p\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMelt Flow Rate Measurement Principle\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe QualiFi™ 6000SA operates based on the extrusion plastometer principle defined in ISO 1133 and ASTM D1238. A thermoplastic resin sample is introduced into a heated barrel and stabilized at the specified test temperature. A piston applies a defined load, forcing the molten polymer through a standard die (Φ2.095 mm) located at the base of the barrel.\u003c\/p\u003e\n\u003cp\u003eMFR (mass method, Procedure A) is determined by measuring the mass of extrudate collected at timed intervals. MVR (volume methods A and B) is calculated from piston displacement over a defined time period. The QualiFi™ 6000SA automates weight lifting, timing control, cutting, and result calculation, while also integrating pneumatic compaction, pneumatic residual extrusion, and pneumatic barrel cleaning. These additions reduce the number of manual operations per test cycle compared to the QualiFi™ 5000.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Compaction System\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eMaterial compaction, the process of pressing the loaded polymer charge into the barrel prior to testing, is performed pneumatically on the QualiFi™ 6000SA with adjustable load and time (10–50 kg). In conventional melt flow index testers, this step is carried out manually using a feeding rod, which can introduce variation in applied force and compaction duration.\u003c\/p\u003e\n\u003cp\u003eThe pneumatic system provides a consistent and repeatable compaction force across all test cycles, independent of operator technique. This improves run-to-run repeatability of MFR\/MVR results, particularly for high-viscosity polymers and powder materials where pre-test density uniformity is critical.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePneumatic Residual Extrusion and Barrel Cleaning\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAfter each test cycle, remaining polymer in the barrel must be removed before the next sample is introduced. The QualiFi™ 6000SA performs this in two pneumatic stages:\u003c\/p\u003e\n\u003cp\u003eFirst, pneumatic residual extrusion applies an adjustable load (10–50 kg) to expel remaining polymer from the barrel and die, replacing manual push-rod operation used in conventional systems.\u003c\/p\u003e\n\u003cp\u003eSecond, pneumatic barrel cleaning uses compressed air to remove residual material from the internal barrel surface.\u003c\/p\u003e\n\u003cp\u003eTogether, these steps significantly reduce post-test turnaround time, minimize operator effort, and reduce exposure to high-temperature components, strengthening the safety-oriented design of the 6000SA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWeight Fall-Prevention Guard\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eIn floor-standing melt flow indexers, the weight stack is positioned at an elevated height, creating a potential risk of uncontrolled descent during setup, weight adjustment, or mechanical irregularities.\u003c\/p\u003e\n\u003cp\u003eThe QualiFi™ 6000SA incorporates a dedicated weight fall-prevention guard that physically restricts the weight stack movement and prevents uncontrolled descent events. This hardware safety mechanism is not included in the QualiFi™ 5000 and is specifically designed for the taller floor-standing structure of the 6000SA.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDual PID Temperature Control and High-Precision Displacement\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe QualiFi™ 6000SA retains the same core temperature control and measurement architecture as the QualiFi™ 5000 platform. A high-temperature heating system and sensor assembly rated for continuous operation from 50 to 450 °C is controlled by a dual PID temperature regulation system.\u003c\/p\u003e\n\u003cp\u003eThis ensures rapid, overshoot-free heating, stable multi-zone thermal distribution with a temperature gradient of less than ±0.1 °C, and recovery to stable conditions within 2 minutes after sample loading.\u003c\/p\u003e\n\u003cp\u003ePiston displacement is measured with a resolution of 0.002 mm and a maximum indication error of ±0.02 mm. Timer resolution is 0.001 s, supporting precise MVR calculation across a measurement range of 0.01 to 3000 cm³\/10 min.\u003c\/p\u003e\n\u003ch2\u003eSemi Automatic Melt Flow Indexer (MFI) – QualiFi™ 6000SA Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eQualiFi™ 6000SA\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Method\u003c\/td\u003e\n\u003ctd\u003eMFR (mass method) \/ MVR (volume method A \u0026amp; B)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMFR Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0.1–100 g\/10min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMVR Measurement Range\u003c\/td\u003e\n\u003ctd\u003e0.01–3000 cm³\/10min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay Mode\u003c\/td\u003e\n\u003ctd\u003eFull-color touch screen (10.1-inch HD)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCutting Method\u003c\/td\u003e\n\u003ctd\u003eAutomatic cutting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTimer Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Control Range\u003c\/td\u003e\n\u003ctd\u003e50–450 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Indication Error\u003c\/td\u003e\n\u003ctd\u003e≤ 0.2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Fluctuation\u003c\/td\u003e\n\u003ctd\u003e≤ ±0.2 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Gradient (0–75 mm above die)\u003c\/td\u003e\n\u003ctd\u003e≤ ±0.3 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Recovery Time (after loading)\u003c\/td\u003e\n\u003ctd\u003e≤ 2 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLoading Mode\u003c\/td\u003e\n\u003ctd\u003eElectric loading — weight preset manually, auto lifted\/lowered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight Selection Mode\u003c\/td\u003e\n\u003ctd\u003eManual pre-selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePreloading Range\u003c\/td\u003e\n\u003ctd\u003eCalibration weight: 0.325–21.6 kg; Additional load: 10–50 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic Compaction Load\u003c\/td\u003e\n\u003ctd\u003e10–50 kg (adjustable), pneumatic operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic Residual Extrusion Load\u003c\/td\u003e\n\u003ctd\u003e10–50 kg (adjustable), pneumatic operation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePneumatic Barrel Cleaning\u003c\/td\u003e\n\u003ctd\u003eYes — compressed air assisted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight Fall-Prevention Guard\u003c\/td\u003e\n\u003ctd\u003eYes — hardware fitted\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiston Displacement Indication Error\u003c\/td\u003e\n\u003ctd\u003e± 0.02 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePiston Displacement Resolution\u003c\/td\u003e\n\u003ctd\u003e0.002 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Die Diameter\u003c\/td\u003e\n\u003ctd\u003eΦ2.095 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage Capacity\u003c\/td\u003e\n\u003ctd\u003e5,000 groups (USB flash drive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTest Plans\u003c\/td\u003e\n\u003ctd\u003e8 configurable and saveable test plans\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAir Source Requirement\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; 0.6 MPa (required for pneumatic functions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e220V (-15% \/ +10%) VAC, 50Hz, 0.5 kVA (110V is also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions L×W×H\u003c\/td\u003e\n\u003ctd\u003e580 × 480 × 1450 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain Unit Weight\u003c\/td\u003e\n\u003ctd\u003e100 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertifications\u003c\/td\u003e\n\u003ctd\u003eCE (EN 61010-1:2010+A1:2019; EN 61326-1:2013); CNAS proficiency verified\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoftware Languages\u003c\/td\u003e\n\u003ctd\u003eEnglish, French, German, Italian, Russian, Chinese\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStandard Configuration\u003c\/h3\u003e\n\u003cp\u003eEach QualiFi™ 6000SA ships with all accessories required for immediate MFR and MVR testing per ISO 1133 and ASTM D1238, plus PC software. Note that a compressed air supply of more than 0.6 MPa is required for the pneumatic functions.\u003c\/p\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eQuantity\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMain unit (including 1 barrel)\u003c\/td\u003e\n\u003ctd\u003e1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBasic weight set (piston rod, guide bush, weight tray, weight cover)\u003c\/td\u003e\n\u003ctd\u003e1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard die Φ2.095 mm\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLevel\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarrel cleaning rod\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFeeding rod\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDie cleaning rod\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCutter\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFunnel\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse\u003c\/td\u003e\n\u003ctd\u003e2 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecial tweezers\u003c\/td\u003e\n\u003ctd\u003e2 pieces\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHexagon wrench (2 mm)\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUSB flash drive\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFixed wrench (8–10)\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower cable\u003c\/td\u003e\n\u003ctd\u003e1 piece\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC software (DMS data management)\u003c\/td\u003e\n\u003ctd\u003e1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOptional Accessories\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eItem\u003c\/th\u003e\n\u003cth\u003eDescription\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Forming Machine\u003c\/td\u003e\n\u003ctd\u003eCompression pre-forming device for powder, flake, film fragment, or granule specimens prior to MFR\/MVR testing — particularly useful for materials that cannot be loaded directly into the melt flow indexer barrel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52007856832823,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/semi-automatic-melt-flow-indexer-mfi653437803.webp?v=1776683406","url":"https:\/\/qualitest.us\/fr\/products\/semi-automatic-melt-flow-indexer-mfi","provider":"Qualitest USA LC","version":"1.0","type":"link"}