{"product_id":"needle-flame-tester","title":"Needle Flame Tester","description":"\u003ch2\u003eNeedle Flame Tester – QualiFlame™ NFT\u003c\/h2\u003e\n\u003ch4\u003eNeedle Flame Test Apparatus for Fire Hazard Testing\u003c\/h4\u003e\n\u003cp\u003eThe QualiFlame™ NFT is designed to determine how electrical components and insulating materials behave when exposed\n    to a localized flame caused by an electrical fault. It generates a controlled 12 mm flame using a stainless steel\n    burner with a 0.5 mm bore, supplied with propane or butane. The tester is suitable for manufacturers of lighting\n    equipment, low-voltage switchgear, household appliances, electric motors, power tools, and electronic instruments.\n    It also supports testing activities in research facilities, manufacturing environments, and quality control\n    laboratories. An integrated PLC system and touchscreen interface manage the testing process.\u003c\/p\u003e\n\u003cp\u003eTesting is conducted in accordance with the needle-flame procedure specified in IEC 60695-11-5. The burner offers\n    three positioning angles: 0°, 20°, and 45°, allowing the flame to contact the specimen in the orientation required\n    by the applicable product standard. Flame exposure can be programmed from 0 s to 999.9 s, with increments of 0.1 s.\n    Although the equipment supports this full timing range, a 30-second exposure is commonly specified by product\n    standards. Afterflame duration is captured automatically, while the operator can also stop the measurement manually\n    when necessary.\u003c\/p\u003e\n\u003cp\u003eBefore specimen testing, burner performance is checked using a Cu-ETP copper block and a 0.5 mm Type K thermocouple.\n    The calibration procedure requires the copper block to reach the specified temperature rise within 23.5 seconds,\n    providing confirmation that the flame meets the required thermal output. A test chamber with an internal volume\n    greater than 0.5 m³ supplies the draught-free environment required by the method. The system operates with\n    commercially available bottled lighter gas containing at least 95% propane or butane, eliminating the need for a\n    dedicated specialty gas supply.\u003c\/p\u003e\n\u003ch2\u003eNeedle Flame Tester – QualiFlame™ NFT Applications\u003c\/h2\u003e\n\u003cp\u003eThe QualiFlame™ NFT supports fire hazard assessments across electrical product manufacturing, material development,\n    and laboratory inspection. It helps determine whether components and insulating materials can withstand localized\n    flame exposure under the conditions specified by relevant safety requirements.\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eLighting Products and Luminaires:\u003c\/strong\u003e Examines lamp holders, driver enclosures, and insulating\n            supports to determine their response when an internal electrical fault produces a flame.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eLow-Voltage Switchgear and Controlgear:\u003c\/strong\u003e Assesses protective barriers, arc chutes, and molded\n            enclosures used in circuit breakers, contactors, and electrical distribution assemblies.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eHousehold Appliance Manufacturing:\u003c\/strong\u003e Evaluates internal plastic parts and wiring supports\n            against needle-flame requirements referenced in appliance safety standards.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eElectric Motors and Rotating Machines:\u003c\/strong\u003e Investigates the flame resistance of slot liners,\n            terminal boxes, and winding insulation systems under potential electrical fault conditions.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003ePower Tools and Portable Equipment:\u003c\/strong\u003e Tests handle materials, switch housings, and internal\n            supporting components that may encounter flames resulting from motor or contact faults.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eElectrical and Electronic Instruments:\u003c\/strong\u003e Examines enclosure materials and internal insulation\n            used in measuring, monitoring, and control equipment.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eElectrical Connectors and Terminal Blocks:\u003c\/strong\u003e Determines how insulating housings perform when\n            positioned close to locations where electrical arcing may occur.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003ePrinted Circuit Board Assembly:\u003c\/strong\u003e Assesses circuit board substrates and component supports to\n            establish their susceptibility to flame propagation following a localized fault.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eInsulating Materials and Engineering Plastics:\u003c\/strong\u003e Compares different material formulations\n            during development and incoming material quality inspections.\u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStandards\u003c\/h2\u003e\n\u003cp\u003eThe QualiFlame™ NFT supports testing in accordance with established requirements for needle-flame apparatus\n    configuration, flame characteristics, and fire hazard evaluation.\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eIEC 60695-11-5:\u003c\/strong\u003e Fire Hazard Testing, Part 11-5: Test Flames, Needle-Flame Test Method,\n            Apparatus, Confirmatory Test Arrangement and Guidance.\u003c\/p\u003e\n    \u003c\/li\u003e\n    \u003cli\u003e\n        \u003cp\u003e\u003cstrong\u003eUL 746A:\u003c\/strong\u003e Standard for Polymeric Materials, Short Term Property Evaluations.\u003c\/p\u003e\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\n\n\u003ch2\u003eNeedle Flame Tester – QualiFlame™ NFT Key Features\u003c\/h2\u003e\n\u003cp\u003eThe QualiFlame™ NFT is built to control the conditions that influence needle-flame test results, from burner\n    positioning and exposure duration to flame verification and temperature measurement.\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eProgrammable PLC-Based Operation:\u003c\/strong\u003e A PLC controller coordinates the testing sequence through\n            a touchscreen interface, managing flame application and timing to minimize variations caused by manual\n            operation.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eThree Burner Positioning Angles:\u003c\/strong\u003e The burner can be positioned at 0°, 20°, or 45°, allowing\n            laboratories to reproduce the flame orientation specified for different product evaluations.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003ePrecision Stainless Steel Burner:\u003c\/strong\u003e A corrosion-resistant stainless steel burner with a 0.5 mm\n            bore produces the needle flame required by the test method while maintaining the specified burner geometry.\n        \u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eFlexible Flame Exposure Programming:\u003c\/strong\u003e Operators can set exposure periods anywhere from 0 s to\n            999.9 s, with 0.1 s resolution. This accommodates the commonly specified 30-second test as well as longer\n            exposure requirements.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eIntegrated Afterflame Monitoring:\u003c\/strong\u003e The instrument automatically measures and records how long\n            a specimen continues burning after flame removal. A manual stop function gives operators additional control\n            when the end of a burning event requires judgment.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003e12 mm Flame Height Verification:\u003c\/strong\u003e A dedicated measurement gauge allows operators to check\n            flame height before testing, helping ensure that every specimen receives the prescribed flame exposure.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eThermal Output Verification with Copper Block:\u003c\/strong\u003e The supplied Cu-ETP copper block provides a\n            measurable reference for checking burner performance. Its specified temperature rise must occur within 23.5\n            seconds to confirm that the flame meets the required thermal conditions.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eArmored Type K Thermocouple:\u003c\/strong\u003e The 0.5 mm thermocouple withstands temperatures up to 1100°C\n            and provides rapid temperature response during timed burner calibration.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eStandard Bottled Gas Operation:\u003c\/strong\u003e The burner accepts commercially available propane or butane\n            with a minimum purity of 95%, allowing laboratories to operate without installing a dedicated specialty gas\n            supply.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eIntegrated Draught-Free Test Chamber:\u003c\/strong\u003e With an internal volume exceeding 0.5 m³, the chamber\n            provides the space required for needle-flame testing under draught-free conditions without an additional\n            enclosure.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eTemperature Measurement from 0°C to 1000°C:\u003c\/strong\u003e The instrument covers a broad measurement range\n            for burner calibration and specimen temperature monitoring, eliminating the need for a separate temperature\n            measurement instrument for these tasks.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eEnglish Interface with Language Options:\u003c\/strong\u003e The standard English-language display is suitable\n            for North American laboratory operations, while alternative language configurations can be provided upon\n            request.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eAdaptable Electrical Configuration:\u003c\/strong\u003e The power supply can be customized to accommodate local\n            mains requirements when the standard 220 V configuration is unsuitable.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\n\n\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003eThe needle-flame test examines how materials respond when a localized fire originates from an electrical fault within\n    equipment. Such an event may begin at an arcing electrical contact or when insulation catches fire. The assessment\n    focuses on whether the initial flame remains confined to the affected area or causes nearby components to ignite and\n    sustain further burning. Unlike glow wire testing, which simulates excessive heating before ignition occurs, the\n    needle-flame method introduces an actual flame with controlled dimensions and thermal characteristics to evaluate\n    the specimen's response.\u003c\/p\u003e\n\u003cp\u003eThe test flame is generated by a needle burner featuring a 0.5 mm bore and supplied with propane or butane. Once\n    correctly adjusted, the burner produces a diffusion flame with a height of 12 mm. Maintaining this specified height\n    is essential because variations in flame dimensions affect the amount of heat transferred to the specimen. The\n    supplied flame-height gauge is therefore used to check the burner before each test series. The burner can also be\n    positioned at different angles to reproduce the required flame contact conditions. For example, a 45° orientation\n    creates a different pattern of heat exposure across the specimen surface compared with a vertically applied flame.\n\u003c\/p\u003e\n\u003cp\u003eBurner heat output is verified using a drilled Cu-ETP copper block weighing 0.58 g, together with a 0.5 mm Type K\n    thermocouple. Under the specified flame conditions, the copper block must achieve the required temperature rise\n    within 23.5 seconds. Meeting this time requirement confirms that the burner delivers the prescribed thermal energy\n    and gives the laboratory measurable calibration evidence rather than relying solely on visual flame assessment.\u003c\/p\u003e\n\u003cp\u003eOnce flame verification is complete, the specimen is exposed for the duration required by the applicable testing\n    standard, typically 30 seconds. The evaluation then considers how long the specimen continues burning after the\n    flame is removed, whether fire spreads across the material, and whether burning particles or other material ignite\n    the specified material positioned beneath the specimen.\u003c\/p\u003e\n\u003ch2\u003eNeedle Flame Tester - QualiFlame™ NFT Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table table-style-align-center\" align=\"center\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\" width=\"610\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth\u003eParameter\u003c\/th\u003e\n            \u003cth\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eModel\u003c\/td\u003e\n            \u003ctd\u003eQualiFlame™ NFT\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eNeedle Burner\u003c\/td\u003e\n            \u003ctd\u003eØ0.5 mm ±0.1 mm inner bore, ≥9 mm outer diameter, ≥35 mm length, stainless steel\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eBurner Angle\u003c\/td\u003e\n            \u003ctd\u003e0°, 20°, 45° (flame height adjustable)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eThermocouple\u003c\/td\u003e\n            \u003ctd\u003eØ0.5 mm Type K (Ni\/Cr-Ni\/Al), armored sheath rated to 1100°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eFlame Application Time\u003c\/td\u003e\n            \u003ctd\u003e0 s to 999.9 s ±0.1 s, adjustable (30 s typical)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eAfterflame Timing\u003c\/td\u003e\n            \u003ctd\u003e0 s to 999.9 s ±0.1 s, automatic recording with manual timeout\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eFlame Height\u003c\/td\u003e\n            \u003ctd\u003e12 mm ±1 mm (measurement gauge supplied)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eFlame Gas\u003c\/td\u003e\n            \u003ctd\u003ePropane or butane, 95% minimum purity (bottled lighter gas acceptable)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTemperature Measurement Range\u003c\/td\u003e\n            \u003ctd\u003e0°C to 1000°C\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eFlame Temperature Rise Requirement\u003c\/td\u003e\n            \u003ctd\u003e100°C ±2°C to 700°C ±3°C in 23.5 s ±1 s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eCalibration Copper Block\u003c\/td\u003e\n            \u003ctd\u003eØ4 mm ±0.01 mm, 0.58 g ±0.01 g before drilling, Cu-ETP\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTest Process\u003c\/td\u003e\n            \u003ctd\u003eAutomatic control, independent test cycle\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eChamber Volume\u003c\/td\u003e\n            \u003ctd\u003e≥0.5 m³\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eController\u003c\/td\u003e\n            \u003ctd\u003ePLC with integrated touch interface\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n            \u003ctd\u003e1100 × 740 × 1250 mm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eVoltage\u003c\/td\u003e\n            \u003ctd\u003e220 V, 48 Hz to 60 Hz, 800 VA (110V is also available)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eDisplay Panel Language\u003c\/td\u003e\n            \u003ctd\u003eEnglish (other languages available on request)\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":53638743654711,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/needle-flame-tester2131322765.webp?v=1794893440","url":"https:\/\/qualitest.us\/fr\/products\/needle-flame-tester","provider":"Qualitest USA LC","version":"1.0","type":"link"}