{"product_id":"cord-anchorage-tester","title":"Cord Anchorage Tester","description":"\u003ch2\u003eCord Anchorage Tester – QualiCAT™\u003c\/h2\u003e\n\u003cp\u003eThe QualiCAT™ Cord Anchorage Tester evaluates the mechanical security of appliance power cords by subjecting their\n    connection points to controlled pulling forces and rotational loads. These tests determine whether the anchorage can\n    prevent cable movement and protect internal electrical connections from mechanical stress. Designed for appliance\n    manufacturers and product safety laboratories, the system combines both assessments into an automated testing cycle,\n    allowing operators to configure the required parameters before the instrument carries out the complete procedure.\n\u003c\/p\u003e\n\u003cp\u003eWhen a cord anchorage fails to hold the cable securely, external pulling and twisting forces can reach the electrical\n    terminals inside the appliance. Repeated cable movement may loosen connections or damage conductor insulation where\n    the cord enters the enclosure. The QualiCAT™ evaluates this risk by measuring the displacement of a reference mark\n    on the cord after both loading stages have been completed. This provides a measurable indication of how effectively\n    the anchorage prevents cable movement.\u003c\/p\u003e\n\u003cp\u003eTo accommodate different testing workloads, the QualiCAT™ is offered with either one or six testing stations. Its\n    PLC-based control system and touchscreen interface manage the pulling cycles and torque application, with adjustable\n    repetition counts and torque holding times for different appliance requirements. The supplied graduated weight\n    system provides tensile forces of 30 N, 60 N, and 100 N, together with torque settings of 0.1 Nm, 0.25 Nm, and 0.35\n    Nm.\u003c\/p\u003e\n\u003ch2\u003eCord Anchorage Tester – QualiCAT™ Applications\u003c\/h2\u003e\n\u003cp\u003eThe QualiCAT™ is suitable for manufacturers, component suppliers, and testing facilities that need to establish\n    whether a power cord remains securely attached to an electrical product under prescribed mechanical loading\n    conditions.\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eHousehold Appliance Manufacturing:\u003c\/strong\u003e Assess the effectiveness of power cord retention systems\n            in products such as kettles, blenders, vacuum cleaners, heaters, and other corded appliances subject to IEC\n            60335-1 requirements.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eCompliance and Certification Laboratories:\u003c\/strong\u003e Conduct independent tensile and torque\n            assessments on submitted appliance samples to establish whether their cord anchorage arrangements satisfy\n            safety certification requirements.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003ePower Tool and Portable Equipment Production:\u003c\/strong\u003e Evaluate whether cable clamps and strain\n            relief assemblies can withstand the pulling forces and repeated handling associated with handheld tools and\n            portable equipment.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eCord Set and Cable Assembly Suppliers:\u003c\/strong\u003e Examine molded strain relief components and\n            mechanical clamping arrangements to verify their suitability before supplying cable assemblies to appliance\n            manufacturers.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003ePermanently Connected Equipment:\u003c\/strong\u003e Assess flexible cord connections on equipment linked to\n            fixed electrical wiring, ensuring that mechanical loads are contained at the anchorage rather than\n            transferred to the terminal block.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eLighting and Luminaire Manufacturing:\u003c\/strong\u003e Verify the mechanical retention of flexible power\n            leads fitted to portable lighting products and pendant luminaires.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eMedical and Laboratory Equipment:\u003c\/strong\u003e Evaluate power cord attachment systems on mains-operated\n            instruments, where movement or loosening at an electrical connection could introduce a safety risk.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eDesign Verification and Failure Analysis:\u003c\/strong\u003e Compare alternative clamp configurations, grommet\n            materials, and overmold designs to identify differences in cord retention performance during product\n            development and failure investigations.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eIncoming Quality Control:\u003c\/strong\u003e Inspect purchased cord assemblies and partially assembled\n            appliances to determine whether their anchorage performance meets established purchasing and acceptance\n            requirements.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStandards\u003c\/h2\u003e\n\u003cp\u003eThe QualiCAT™ is designed to carry out cord anchorage assessments using the prescribed test arrangement, mechanical\n    loads, and application periods specified in the applicable household appliance safety standard.\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\u003cstrong\u003eIEC 60335-1:\u003c\/strong\u003e Household and Similar Electrical Appliances – Safety, Part 1: General\n        Requirements. Clause 25.15 specifies the cord anchorage pull and torque test.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCord Anchorage Tester – QualiCAT™ Key Features\u003c\/h2\u003e\n\u003cp\u003eThe QualiCAT™ integrates programmable test control and calibrated dead-weight loading to perform the required cord\n    retention assessments through a coordinated testing process.\u003c\/p\u003e\n\u003cul\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eIntegrated Pull and Torque Testing:\u003c\/strong\u003e Both mechanical assessments run in sequence under\n            automatic control. Once the programmed tension cycles are complete, the system proceeds to torque\n            application without requiring the operator to manually transfer between test stages.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003ePLC-Based Touchscreen Operation:\u003c\/strong\u003e An integrated touchscreen provides access to test settings\n            and operating controls, allowing technicians to configure and monitor procedures through a centralized\n            interface.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eSingle or Six Testing Stations:\u003c\/strong\u003e Available configurations accommodate different laboratory\n            capacities, whether testing individual development samples or processing six specimens simultaneously.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eProgrammable Tension Repetitions:\u003c\/strong\u003e The cycle counter can be configured from 0 to 9,999\n            repetitions, supporting the standard 25-cycle procedure as well as higher repetition requirements for other\n            product categories.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eConsistent 1 Hz Pulling Frequency:\u003c\/strong\u003e Each tension cycle is applied at a fixed rate of one per\n            second, maintaining the prescribed loading frequency for repeatable assessments.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eAdjustable Torque Holding Period:\u003c\/strong\u003e Operators can set the torque application duration between\n            0.1 and 999 seconds, accommodating the standard 60-second holding period and longer investigative tests.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eCalibrated Tensile Weight Set:\u003c\/strong\u003e The supplied dead weights can be combined to generate pulling\n            forces of 30 N, 60 N, and 100 N, corresponding to the specified appliance mass categories and\n            fixed-appliance requirement.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eThree Torque Loading Options:\u003c\/strong\u003e Dedicated graduated weights provide torque values of 0.1 Nm,\n            0.25 Nm, and 0.35 Nm, matching the corresponding force combinations required by the test procedure.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eGravity-Based Load Application:\u003c\/strong\u003e Dead weights maintain the applied mechanical load throughout\n            the holding period without servo-driven force adjustments or associated calibration drift.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eEnglish Touchscreen Interface:\u003c\/strong\u003e The instrument comes with an English-language operating\n            interface, with additional language options available upon request.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n    \u003cli\u003e\n\n\n        \u003cp\u003e\u003cstrong\u003eMobile Floor-Standing Construction:\u003c\/strong\u003e A cabinet fitted with caster wheels allows the tester to\n            be moved between laboratory workstations and testing areas without dismantling the equipment.\u003c\/p\u003e\n\n\n    \u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003eThe purpose of cord anchorage testing is to determine whether an appliance's cable retention arrangement can\n    withstand external mechanical forces without transferring them to the internal electrical connections. A properly\n    secured cord should remain in position when subjected to pulling and twisting loads. The assessment therefore\n    reproduces these forces under controlled conditions and measures any resulting cable displacement.\u003c\/p\u003e\n\u003cp\u003eBefore testing, the specimen is secured in position and the cord is subjected to the specified tensile load. While\n    this force is maintained, the operator places a reference mark approximately 20 mm from the anchorage. This marking\n    establishes the original measurement position, making it possible to determine how far the cable moves during the\n    complete procedure.\u003c\/p\u003e\n\u003cp\u003eThe first stage evaluates resistance to longitudinal movement through repeated tensile loading. The specified pulling\n    force is applied along the direction considered most unfavorable to the cord anchorage. Each application is\n    introduced smoothly rather than through a sudden impact and maintained for approximately one second. The QualiCAT™\n    repeats the loading cycle at a frequency of 1 Hz, with the repetition count programmable up to 9,999 cycles. This\n    repeated loading reveals gradual cable slippage that may not become apparent during a single pull. As the test\n    reaches its programmed cycle count, the controller automatically advances to the torque assessment.\u003c\/p\u003e\n\u003cp\u003eThe second stage examines the anchorage's ability to resist rotational movement. A controlled twisting moment is\n    applied near the cord entry point, challenging the clamp's ability to prevent the cable from turning within its\n    securing arrangement. Such movement can contribute to loose terminal screws and insulation abrasion where the\n    conductor contacts the enclosure edge. For this assessment, the QualiCAT™ applies the selected calibrated torque\n    weight and maintains the load for the programmed duration, adjustable from 0.1 to 999 seconds.\u003c\/p\u003e\n\u003cp\u003eAfter both stages are complete, the operator measures the final position of the reference mark on the cord. The\n    original 20 mm marking offset is deducted from the final measurement to establish the cable's longitudinal\n    displacement. This measured movement provides the quantitative basis for determining whether the cord anchorage\n    meets the applicable retention requirement.\u003c\/p\u003e\n\u003ch2\u003eCord Anchorage Tester - QualiCAT™ Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table table-style-align-center\" align=\"center\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n    \u003cthead\u003e\n        \u003ctr\u003e\n            \u003cth\u003eParameter\u003c\/th\u003e\n            \u003cth\u003eSpecification\u003c\/th\u003e\n        \u003c\/tr\u003e\n    \u003c\/thead\u003e\n    \u003ctbody\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eModel\u003c\/td\u003e\n            \u003ctd\u003eQualiCAT™\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eWork Stations\u003c\/td\u003e\n            \u003ctd\u003eOne or six (selectable configuration)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003ePull Weights\u003c\/td\u003e\n            \u003ctd\u003e10 N x 1, 20 N x 2, 60 N x 1, combinable to 30 N, 60 N, and 100 N\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTorque Weights\u003c\/td\u003e\n            \u003ctd\u003e2 N x 1, 5 N x 1, 7 N x 1, giving 0.1 Nm, 0.25 Nm, and 0.35 Nm\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTension Times\u003c\/td\u003e\n            \u003ctd\u003e0 to 9,999 (adjustable)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTension Frequency\u003c\/td\u003e\n            \u003ctd\u003e1 time\/s\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eTorque Time\u003c\/td\u003e\n            \u003ctd\u003e0.1 s to 999 s (adjustable)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eController\u003c\/td\u003e\n            \u003ctd\u003ePLC integrated control with touch interface operation\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eInterface Language\u003c\/td\u003e\n            \u003ctd\u003eEnglish (other languages available on request)\u003c\/td\u003e\n        \u003c\/tr\u003e\n        \u003ctr\u003e\n            \u003ctd\u003eVoltage\u003c\/td\u003e\n            \u003ctd\u003eAC 220 V, 50 Hz (customized supply available on request)\u003c\/td\u003e\n        \u003c\/tr\u003e\n    \u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":53636694737207,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/cord-anchorage-tester411781406.webp?v=1794850114","url":"https:\/\/qualitest.us\/fr\/products\/cord-anchorage-tester","provider":"Qualitest USA LC","version":"1.0","type":"link"}