{"title":"Automatic Vicat Needle Apparatus – Multi Station PC-Controlled for Cement \u0026 Gypsum","description":"\u003cp\u003eQUALITEST-TESTING offers a comprehensive range of advanced, PC-controlled, multi-station Automatic Vicat Needle Apparatus Systems designed for Cement and Gypsum Testing Laboratories. These automated Vicat testing systems support demanding testing requirements in accordance with applicable ASTM, EN, and DIN standards.\u003c\/p\u003e\n\u003cp\u003eChoose an Automatic Vicat Needle Apparatus based on your testing volume, laboratory requirements, budget, and applicable testing standards. QUALITEST-TESTING can help you identify the appropriate system configuration for accurate, efficient, and reliable Vicat testing.\u003cbr\u003e\u003c\/p\u003e\n\u003ch3\u003eAvailable Models:\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003eAutoVicat-366 6-Station Automatic Vicat Needle Apparatus\u003c\/li\u003e\n\u003cli\u003eAutoVicat-367 8-Station Automatic Vicat Needle Apparatus\u003c\/li\u003e\n\u003cli\u003eAutoVicat-366-EN-ASTM 6-Station Automatic Vicat Needle Apparatus (Combo EN-ASTM Model)\u003c\/li\u003e\n\u003cli\u003eAutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus (Combo EN-ASTM Model)\u003c\/li\u003e\n\u003cli\u003eAutoVicat-368-EN 12-Station Automatic Vicat Needle Apparatus\u003c\/li\u003e\n\u003cli\u003eAutoVicat-368-GZ 12-Station Automatic Vicat Needle Apparatus (For Gypsum \u0026amp; Cement Paste)\u003c\/li\u003e\n\u003cli\u003eAutoVicat-368-ASTM 12 Station Automatic Vicat Needle Apparatus (For Cement)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd class=\"text-align-center\" colspan=\"2\" rowspan=\"1\"\u003eMaterial\u003c\/td\u003e\n\u003ctd class=\"text-align-center\" colspan=\"2\" rowspan=\"1\"\u003eStandard\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003ePC-Controlled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eCement\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eGypsum\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eEN\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eASTM\u003c\/td\u003e\n\u003ctd class=\"text-align-center\" colspan=\"1\" rowspan=\"6\"\u003e6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoVicat-366\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"text-align-center\"\u003eX\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoVicat-366-ASTM\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"text-align-center\"\u003eX\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoVicat-366-EN-ASTM\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"text-align-center\"\u003eX\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoVicat-366-G\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"text-align-center\"\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoVicat-366-G\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"text-align-center\"\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoVicat-367\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"text-align-center\"\u003eX\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoVicat-367-ASTM\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"text-align-center\"\u003eX\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\" colspan=\"1\" rowspan=\"4\"\u003e8\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoVicat-367-EN-ASTM\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"text-align-center\"\u003eX\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoVicat-367-G\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"text-align-center\"\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoVicat-367-GZ\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp class=\"text-align-center\"\u003eX\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"6\"\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoVicat-368\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003ctd class=\"text-align-center\" colspan=\"1\" rowspan=\"5\"\u003e12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoVicat-368-ASTM\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoVicat-368-EN-ASTM\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoVicat-368-G\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003e \u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoVicat-368-GZ\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd class=\"text-align-center\"\u003eX\u003c\/td\u003e\n\u003ctd\u003e \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eStandard Vicat Testing Theory and Parameters\u003c\/h3\u003e\n\u003cp\u003eManual Vicat setting-time tests can be affected by operator reading and timing variations. The standard testing principle measures the penetration depth of a steel needle into cement or gypsum paste as the material gradually develops resistance during hydration and setting.\u003c\/p\u003e\n\u003cp\u003eFor consistent and repeatable testing, a PC-controlled Automatic Vicat Needle Apparatus, such as the Qualitest AutoVicat Series, automates needle penetration, electronic depth measurement, timing, and data recording.\u003c\/p\u003e\n\u003cp\u003eInternational testing standards, including ASTM C191, EN 196-3, DIN 1168, EN 13279-2, and EN 480-2, define key stages and parameters throughout the setting process:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eNormal Consistency: Determines the required water-to-powder ratio to achieve the specified consistency before setting-time testing begins.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInitial Setting Time: Identifies the stage when the needle no longer penetrates to the specified depth, with the penetration typically stopping approximately 6 ± 3 mm above the base plate according to the applicable procedure.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFinal Setting Time: Determines when the material has hardened sufficiently that the needle produces little or no visible penetration, according to the requirements of the applicable standard.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese testing procedures apply to hydraulic cement as well as plaster and gypsum-based materials. To support different testing requirements, Qualitest offers versatile combination EN-ASTM models, including the AutoVicat-366-EN-ASTM and AutoVicat-367-EN-ASTM, allowing laboratories to perform testing for multiple standards through a single automated system.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eOperational Advantages of Automated Vicat Systems\u003c\/h2\u003e\n\u003cp\u003eManual Vicat testing requires consistent operator attention for timing, needle positioning, penetration measurement, and result recording. A PC-controlled Automatic Vicat Needle Apparatus automates these steps using motorized mechanisms, electronic sensors, and programmable testing sequences to improve testing consistency and reduce manual intervention.\u003c\/p\u003e\n\u003cp\u003eAutomated Vicat systems can also increase laboratory productivity, particularly in quality control environments where multiple samples require regular setting-time evaluation. Multi-station configurations allow several specimens to be tested within the same workflow while maintaining controlled testing parameters.\u003c\/p\u003e\n\u003ch3\u003eAutomated Testing Capabilities\u003c\/h3\u003e\n\u003ch4\u003eMulti-Station Parallel Testing\u003c\/h4\u003e\n\u003cp\u003eMulti-station Automatic Vicat systems allow laboratories to evaluate several samples within the same testing cycle. The Qualitest range includes the 6-station AutoVicat-366, 8-station AutoVicat-367, and 12-station AutoVicat-368-EN\/ASTM. The 12-station configuration places the measuring stations within a rectangular testing bath and integrates them with a stainless steel work table for convenient laboratory operation.\u003c\/p\u003e\n\u003ch4\u003eMulti-Axis Programmable Motion and Environmental Control\u003c\/h4\u003e\n\u003cp\u003eAdvanced Vicat systems provide programmable side-to-side, vertical, and rotational movement for automated sample testing. For ASTM C191 procedures, selected configurations can perform multiple programmed penetrations at defined intervals throughout an extended testing period. Models such as the AutoVicat-366 can also be configured with an optional cooling unit to help maintain the required temperature conditions during testing.\u003c\/p\u003e\n\u003ch4\u003eAutomated Continuous Operation\u003c\/h4\u003e\n\u003cp\u003eSelected models, including the AutoVicat-368-GZ, are designed for automated testing of gypsum and cement paste. Features such as motorized sample positioning, needle-cleaning wipers, programmable test sequences, and adjustable timing support continuous operation with minimal manual intervention. Automated penetration and electronic measurement also reduce dependence on visual scale readings and manual recording.\u003c\/p\u003e\n\u003ch3\u003ePerformance Comparison: Manual Testing vs. PC-Controlled Systems\u003c\/h3\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"8\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eTesting Variable\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eTraditional Manual Method\u003c\/th\u003e\n\u003cth scope=\"col\"\u003ePC-Controlled Automatic Method\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNeedle Deployment \u0026amp; Timing\u003c\/td\u003e\n\u003ctd\u003eOperated by a person (making it highly prone to annoying timing drift)\u003c\/td\u003e\n\u003ctd\u003eMotor-driven and tracked with second-by-second software precision\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePenetration Depth Measurement\u003c\/td\u003e\n\u003ctd\u003eVisual estimation of a physical ruler (heavily subject to operator bias)\u003c\/td\u003e\n\u003ctd\u003eHigh-resolution electronic displacement sensors recording to a tiny fraction of a millimeter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen Repositioning\u003c\/td\u003e\n\u003ctd\u003eShifting the sample cup by hand between drops\u003c\/td\u003e\n\u003ctd\u003eMotorized rotary stage spacing out each penetration perfectly\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Capture \u0026amp; Reporting\u003c\/td\u003e\n\u003ctd\u003eWriting numbers on paper and drawing charts by hand\u003c\/td\u003e\n\u003ctd\u003eAutomated digital logging, beautifully generated live-updating hydration curves, and exportable PDF files straight from the Qualitest interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eMechanical Interpretation of Vicat Penetration\u003c\/h2\u003e\n\u003cp\u003eVicat penetration testing provides more than a simple measurement of needle depth. It helps characterize the setting and hardening process by tracking changes in the resistance of cement or gypsum paste as hydration progresses. As the material reacts with water, its internal structure develops and resistance to needle penetration gradually increases.\u003c\/p\u003e\n\u003cp\u003eThis measurable relationship provides laboratories with objective numerical data for evaluating setting behavior rather than relying solely on visual observations or subjective estimates. The resulting data can support research and quality control activities, including the evaluation of chemical admixtures, mineral additives, and material formulations.\u003c\/p\u003e\n\u003cp\u003eWith an Automatic Vicat Needle Apparatus, penetration measurements can be performed at programmed intervals, recorded electronically, and organized for further analysis. This improves data traceability and helps laboratories maintain consistent testing procedures across multiple samples and batches.\u003c\/p\u003e\n\u003chr\u003e\n\u003ch2\u003eAlternative and Complementary Testing Methods\u003c\/h2\u003e\n\u003cp\u003eAlthough Vicat needle penetration remains a widely used reference technique for determining setting characteristics, laboratories may also use complementary methods to obtain additional information about cement and gypsum systems. These techniques can include electrical resistivity measurements, ultrasonic testing, and temperature monitoring through semi-adiabatic calorimetry.\u003c\/p\u003e\n\u003cp\u003eEach method evaluates different physical or chemical characteristics of the material. Electrical measurements can track changes in conductivity or resistivity, ultrasonic techniques can monitor changes in wave transmission, and calorimetry can provide information related to heat development during hydration.\u003c\/p\u003e\n\u003cp\u003eThese alternative techniques can complement conventional Vicat testing, but their measurements are not direct substitutes for the penetration parameters defined by applicable testing standards. For laboratories requiring standardized setting-time measurements, an Automatic Vicat Needle Apparatus provides direct penetration data that can be documented and compared according to the relevant testing procedure.\u003c\/p\u003e\n\u003cp\u003eSystems such as the AutoVicat-368 can further support high-volume testing by automating sample positioning, needle penetration, measurement intervals, and digital data recording, helping laboratories maintain consistent and traceable Vicat testing workflows.\u003c\/p\u003e","products":[{"product_id":"autovicat-367-en-astm-8-station-automatic-vicat-needle-apparatus-combo-en-astm-model","title":"AutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus (Combo EN-ASTM Model)","description":"\u003ch2\u003eAutoVicat-367-EN-ASTM – 8-Station Automatic Vicat Needle Apparatus\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-367-EN-ASTM is an advanced 8-Station Automatic Vicat Needle Apparatus designed for efficient and precise testing of construction materials. This EN-ASTM combination model supports testing procedures based on both European and ASTM standards, providing a versatile solution for cement and related material laboratories.\u003c\/p\u003e\n\u003cp\u003eFeaturing programmable test sequences and dedicated data recording software, the system streamlines Vicat testing while improving measurement consistency and laboratory productivity. Its multi-station configuration allows multiple samples to be tested efficiently, while the supplied accessories support complete testing workflows.\u003c\/p\u003e\n\u003cp\u003eWith automated operation, computerized data management, and compatibility with EN and ASTM Vicat testing requirements, the AutoVicat-367-EN-ASTM provides a reliable solution for quality control, research, and material testing applications.\u003c\/p\u003e\n\u003ch2\u003eAutoVicat-367-EN-ASTM – 8-Station Automatic Vicat Needle Apparatus\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus is designed for automated determination of initial and final setting times of cement and related construction materials. This EN-ASTM combination model supports testing according to EN 196-3, ASTM C191 Method B, and EN 480-2, with the required optional equipment.\u003c\/p\u003e\n\u003cp\u003eThe system features eight measuring points arranged in a rectangular trough, allowing multiple samples to be tested within a single setup. Testing can be performed in air or in a constant-temperature water bath. The water-bath configuration can include a heat exchanger and cooler to help maintain the required test temperature.\u003c\/p\u003e\n\u003cp\u003eFor EN-based testing, the apparatus supports programmable test sequences, helping streamline automated Vicat penetration measurements. For ASTM testing, samples can be tested in humid air conditions above 95% relative humidity, as required by the applicable procedure.\u003c\/p\u003e\n\u003cp\u003eDuring operation, the system automatically records the initial setting time, final setting time, and corresponding setting plots. The combined weight of the plunger and Vicat needle is 300 g with a tolerance of ±1 g. After every penetration, the Vicat needle is automatically cleaned, helping maintain consistent testing conditions throughout the sequence.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e8-station automatic Vicat testing system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports EN 196-3, ASTM C191 Method B, and EN 480-2\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomated measurement of initial and final setting times\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic recording of setting curves and test data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProgrammable testing sequences for EN procedures\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting in air or constant-temperature water bath\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional heat exchanger and cooling system for temperature control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e300 g ±1 g combined plunger and needle weight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic cleaning of the Vicat needle after each penetration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRectangular trough with eight measuring positions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eImportant Note\u003c\/h3\u003e\n\u003cp\u003eA standard PC or laptop is required to operate the equipment and is not included with the apparatus.\u003c\/p\u003e\n\u003cp\u003eFor EN 480-2 testing, the following additional equipment is required:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAdditional weight: 1.0366.10\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlunger: 1.0366.12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional extra cooling unit: 1.0366.13, for maintaining a test temperature of 5°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTheory and Methodology\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus applies the standard Vicat penetration principle to evaluate how cement or gypsum paste develops resistance to penetration as setting progresses. By automating the penetration sequence and recording measurements digitally, the system helps reduce manual intervention and provides consistent monitoring of the material's transition from a workable paste toward a rigid structure.\u003c\/p\u003e\n\u003ch2\u003eStandard Vicat Penetration Theory\u003c\/h2\u003e\n\u003cp\u003eVicat testing determines setting behavior by measuring the penetration of a standardized needle or plunger into a prepared cement paste at controlled time intervals.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eInitial Setting Time: The point at which the penetration reaches the specified criterion for initial set, indicating that the paste is beginning to lose its plastic and workable characteristics.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFinal Setting Time: The point at which the penetration reaches the specified final-set criterion, indicating that the material has developed substantially greater structural rigidity.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe applicable requirements of ASTM C191 Method B, EN 196-3, and EN 480-2 define important testing parameters, including specimen preparation, apparatus configuration, environmental conditions, and penetration components. The combined weight of the plunger and Vicat needle is 300 g with a tolerance of ±1 g, according to the applicable setup.\u003c\/p\u003e\n\u003ch2\u003eAutoVicat-367-EN-ASTM Method Execution\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-367-EN-ASTM automates the Vicat penetration process through programmed mechanical operation, electronic measurement, and computerized data recording. This approach provides a repeatable testing sequence while reducing the need for continuous manual observation.\u003c\/p\u003e\n\u003ch3\u003eMulti-Station Testing Capacity\u003c\/h3\u003e\n\u003cp\u003eThe system incorporates eight measuring points arranged in a rectangular trough, allowing multiple specimens to be evaluated within one testing setup. The apparatus automatically moves between measuring positions according to the programmed sequence, supporting efficient multi-sample testing.\u003c\/p\u003e\n\u003ch3\u003eAutomated Needle Penetration\u003c\/h3\u003e\n\u003cp\u003eThe apparatus controls the penetration process mechanically according to the programmed test sequence. Automated positioning and measurement help maintain consistent testing intervals and reduce variations associated with repeated manual operation.\u003c\/p\u003e\n\u003ch3\u003eAutomatic Needle Cleaning\u003c\/h3\u003e\n\u003cp\u003eAfter each penetration, the Vicat needle is automatically cleaned before the next measurement. This helps prevent residual cement paste from affecting subsequent penetration measurements and supports consistent test conditions throughout the sequence.\u003c\/p\u003e\n\u003ch3\u003eTemperature and Humidity Control\u003c\/h3\u003e\n\u003cp\u003eTesting can be performed in air or in a constant-temperature water bath, depending on the applicable procedure and configuration. The water-bath setup can include a heat exchanger and cooling unit for maintaining the required temperature. For ASTM testing, the required humid-air conditions above 95% relative humidity can be provided using the appropriate environmental setup.\u003c\/p\u003e\n\u003ch3\u003eDigital Depth and Setting-Time Recording\u003c\/h3\u003e\n\u003cp\u003eElectronic measurement and PC-based software allow the system to record penetration data throughout the test. The apparatus automatically determines and records initial setting time, final setting time, and setting plots, providing a digital representation of the material's setting progression for analysis and documentation.\u003c\/p\u003e\n\u003ch2\u003eAutoVicat-367-EN-ASTM 8-Station Automatic Vicat Needle Apparatus (Combo EN-ASTM Model)Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e700 x 600 x 600 mm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e55 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e110 - 230 V \/ 50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScope of delivery\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThe Base unit is designed as a table model, including the control unit and standard software for programmable test sequences and data recording.\u003c\/li\u003e\n\u003cli\u003e8 Vicat molds (conical hard plastic rings) measuring 70\/80 mm in diameter and 40 mm in height (compliant with EN standards).\u003c\/li\u003e\n\u003cli\u003e8 Vicat molds (conical hard plastic rings) measuring 60\/70 mm in diameter and 40 mm in height (compliant with ASTM standards).\u003c\/li\u003e\n\u003cli\u003e8 glass base plates, each with a diameter of 120 mm.\u003c\/li\u003e\n\u003cli\u003e8 centerings for Vicat molds (conical hard plastic rings) measuring 70\/80 mm in diameter and 40 mm in height (EN compliant).\u003c\/li\u003e\n\u003cli\u003e8 centerings for Vicat molds (conical hard plastic rings) measuring 60\/70 mm in diameter and 40 mm in height (ASTM compliant).\u003c\/li\u003e\n\u003cli\u003e1 pair of cleaning brushes.\u003c\/li\u003e\n\u003cli\u003e1 tee wrench, size 1.25 mm.\u003c\/li\u003e\n\u003cli\u003e1 tee wrench, size 2 mm.\u003c\/li\u003e\n\u003cli\u003e2 spare glass plates, each with a diameter of 120 mm.\u003c\/li\u003e\n\u003cli\u003e2 spare initial-set needles, diameter 1.13 mm (EN).\u003c\/li\u003e\n\u003cli\u003e3 spare initial-set needles, diameter 1.0 mm (ASTM).\u003c\/li\u003e\n\u003cli\u003eCoarse filter sponge.\u003c\/li\u003e\n\u003cli\u003eFine filter sponge.\u003c\/li\u003e\n\u003cli\u003eSerial cable.\u003c\/li\u003e\n\u003cli\u003eFrame for the cover plate.\u003c\/li\u003e\n\u003cli\u003e8 cover plates for generating moist air (ASTM).\u003c\/li\u003e\n\u003cli\u003eHermetic stopper (ASTM).\u003c\/li\u003e\n\u003cli\u003eMud stop sponge (ASTM).\u003c\/li\u003e\n\u003cli\u003eDearerate set hose (ASTM).\u003c\/li\u003e\n\u003cli\u003eHumidity sensor cover (ASTM).\u003c\/li\u003e\n\u003cli\u003eUSB\/RS232 adapter.\u003c\/li\u003e\n\u003cli\u003eMains cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":53065213346103,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/autovicat-367-en-astm-8-station.webp?v=1790679742"},{"product_id":"autovicat-366-en-astm-6-station-automatic-vicat-needle-apparatus-combo-en-astm-model","title":"AutoVicat-366-EN-ASTM 6-Station Automatic Vicat Needle Apparatus (Combo EN-ASTM Model)","description":"\u003ch2\u003eAutoVicat-366-EN-ASTM 6-Station Automatic Vicat Needle Apparatus\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-366-EN-ASTM 6-Station Automatic Vicat Needle Apparatus is a versatile, PC-controlled testing system designed for efficient Vicat testing in accordance with applicable EN and ASTM standards. This combo EN-ASTM model provides a streamlined solution for laboratories that require consistent testing across multiple specimens.\u003c\/p\u003e\n\u003cp\u003eThe system features a base unit with programmable test sequences and data recording capabilities, allowing testing procedures to be configured and results to be recorded systematically. Six dedicated testing stations are supplied with Vicat molds, glass base plates, cleaning tools, spare parts, and essential accessories.\u003c\/p\u003e\n\u003cp\u003eDesigned for laboratories performing cement and related materials testing, the 6-station automatic Vicat apparatus supports efficient multi-sample testing while helping maintain consistent test conditions and reliable measurement results. Its combination of automated operation, programmable testing, and six testing positions makes the AutoVicat-366-EN-ASTM suitable for routine laboratory quality control and materials analysis.\u003c\/p\u003e\n\u003ch2\u003eAutoVicat-366-EN-ASTM 6-Station Automatic Vicat Needle Apparatus (Combo EN-ASTM Model)\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-366-EN-ASTM 6-Station Automatic Vicat Needle Apparatus is a universal testing system designed for Vicat setting time determination in accordance with EN 196-3, EN 480-2, and ASTM C191 Method B. This combo EN-ASTM model integrates six measuring positions in a 2 × 3 rectangular trough configuration, supporting efficient testing of multiple specimens.\u003c\/p\u003e\n\u003ch3\u003eFlexible Testing Conditions\u003c\/h3\u003e\n\u003cp\u003eThe apparatus supports testing in air or in a temperature-controlled water bath. The integrated heat exchanger and cooler help maintain a consistent water temperature throughout the test. For EN testing, programmable test sequences allow the testing procedure to follow defined measurement intervals and conditions. ASTM testing can be performed under humid air conditions above 95% relative humidity.\u003c\/p\u003e\n\u003ch3\u003eAutomatic Setting Time Measurement\u003c\/h3\u003e\n\u003cp\u003eThe system automatically monitors and records the initial setting time and final setting time of the tested material. Test results are presented as setting plots, providing a clear representation of penetration behavior throughout the testing process.\u003c\/p\u003e\n\u003cp\u003eThe Vicat plunger and needle assembly has an additional weight of 300 g ± 1 g, supporting the specified penetration procedure. After each penetration cycle, the apparatus automatically cleans the Vicat needle, helping maintain consistent testing conditions and reducing the need for manual cleaning between measurements.\u003c\/p\u003e\n\u003cp\u003eWith six measuring stations, programmable test sequences, automatic data recording, controlled testing conditions, and automatic needle cleaning, the AutoVicat-366-EN-ASTM provides an efficient solution for automated Vicat setting time testing of cement and related materials.\u003c\/p\u003e\n\u003ch2\u003eAutoVicat-366-EN-ASTM 6-Station Automatic Vicat Needle Apparatus (Combo EN-ASTM Model) Technical Specifications:\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e700 x 600 x 600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e110 - 230 V \/ 50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScope of delivery\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThe Base unit is designed as a table model with the control unit and standard software for programmable test sequences and data recording\u003c\/li\u003e\n\u003cli\u003e6 Vicat molds (conical hard plastic rings) 70\/80 diameter x 40 mm (EN)\u003c\/li\u003e\n\u003cli\u003e6 Vicat molds (conical hard plastic rings) 60\/70 diameter x 40 mm (ASTM)\u003c\/li\u003e\n\u003cli\u003e6 glass base plates, 120 mm diameter\u003c\/li\u003e\n\u003cli\u003e6 centerings for Vicat molds (conical hard plastic rings) 70\/80 diameter x 40 mm (EN)\u003c\/li\u003e\n\u003cli\u003e6 centerings for Vicat molds (conical hard plastic rings) 60\/70 diameter x 40 mm (ASTM)\u003c\/li\u003e\n\u003cli\u003e1 pair of cleaning brushes\u003c\/li\u003e\n\u003cli\u003e1 tee wrench, 1.25 mm\u003c\/li\u003e\n\u003cli\u003e1 tee wrench, 2 mm\u003c\/li\u003e\n\u003cli\u003e2 spare glass plates, 120 mm diameter\u003c\/li\u003e\n\u003cli\u003e2 spare initial-set needles, 1.13 mm diameter (EN)\u003c\/li\u003e\n\u003cli\u003e3 spare initial-set needles, 1.0 mm diameter (ASTM)\u003c\/li\u003e\n\u003cli\u003eCoarse filter sponge\u003c\/li\u003e\n\u003cli\u003eFine filter sponge\u003c\/li\u003e\n\u003cli\u003eSerial cable\u003c\/li\u003e\n\u003cli\u003eFrame for cover plate\u003c\/li\u003e\n\u003cli\u003e6 x Cover plates for the generation of moist air (ASTM)\u003c\/li\u003e\n\u003cli\u003eHermetic stopper (ASTM)\u003c\/li\u003e\n\u003cli\u003eMud stop sponge (ASTM)\u003c\/li\u003e\n\u003cli\u003eDecrease set hose (ASTM)\u003c\/li\u003e\n\u003cli\u003eHumidity sensor cover (ASTM)\u003c\/li\u003e\n\u003cli\u003eUSB\/RS232 Adapter\u003c\/li\u003e\n\u003cli\u003eMain cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv id=\"gtx-trans\"\u003e\n\u003ch2 class=\"gtx-trans-icon\"\u003e \u003c\/h2\u003e\n\u003c\/div\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":53065214132535,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/autovicat-366-en-astm-6-station.webp?v=1790679950"},{"product_id":"autovicat-368-en-12-station-automatic-vicat-needle-apparatus","title":"AutoVicat-368-EN 12-Station Automatic Vicat Needle Apparatus","description":"\u003ch2\u003eAutoVicat-368-EN 12-Station Automatic Vicat Needle Apparatus\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-368-EN 12-Station Automatic Vicat Needle Apparatus is designed for efficient and precise Vicat testing of construction materials. With 12 automated measuring points, programmable test sequences, automatic data recording, and integrated needle cleaning, the system supports consistent determination of setting behavior. Testing can be performed in air or under controlled water-bath conditions for reliable laboratory results.\u003c\/p\u003e\n\u003ch2\u003eAutoVicat-368-EN 12-Station Automatic Vicat Needle Apparatus\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-368-EN provides a multi-station testing configuration for laboratories that require automated and repeatable Vicat testing. Its integrated stainless steel workbench, temperature-controlled water bath capability, programmable testing functions, and automatic penetration-point cleaning help streamline the testing process.\u003c\/p\u003e\n\u003ch3\u003eConfiguration and Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e12 Measuring Stations: The system provides 12 measuring points arranged in a 4\/4\/4 configuration within a rectangular trough integrated into the stainless steel workbench.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAir or Water-Bath Testing: Tests can be performed in air or in a constant-temperature water bath. A heat exchanger and cooler are included to help maintain the required water temperature.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProgrammable Test Sequences: Automated test sequences record the start and end times of the setting process and generate plots of the recorded setting data.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e300 g Additional Load: The plunger and Vicat needle assembly has an additional weight of 300 g ± 1 g.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic Needle Cleaning: The Vicat needle is automatically cleaned after each penetration, helping maintain consistent testing conditions between measurements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePC-Controlled Operation: A standard PC or laptop is required for operation and control of the testing system.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eImportant Notes\u003c\/h3\u003e\n\u003cp\u003eFor testing according to EN 480-2, the following components are required:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAdditional weight (1.0366.10)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlunger (1.0366.12)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional extra cooling unit (1.0366.13) for achieving a test temperature of 5°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eA standard PC or laptop is required for operation and is not included in the scope of delivery.\u003c\/p\u003e\n\u003ch2\u003eAutoVicat-368-EN 12-Station Automatic Vicat Needle Apparatus Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cp\u003eDimension (W x D x H)\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e1000 x 700 x 1140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e195 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e110 - 230 V \/ 50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScope of Delivery:\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eThe Base unit, a floor-mounted appliance, with the control unit\u003c\/li\u003e\n\u003cli\u003eStandard software for programmable test sequences and data recording\u003c\/li\u003e\n\u003cli\u003e12 Vicat molds (conical hard plastic rings), each measuring 70\/80 diameter x 40 mm\u003c\/li\u003e\n\u003cli\u003e12 glass base plates, each with a diameter of 120 mm\u003c\/li\u003e\n\u003cli\u003e12 centerings for Vicat molds (conical hard plastic rings), each measuring 70\/80 diameter x 40 mm\u003c\/li\u003e\n\u003cli\u003e2 pairs of cleaning brushes\u003c\/li\u003e\n\u003cli\u003e1 tee wrench, 1.25 mm\u003c\/li\u003e\n\u003cli\u003e1 tee wrench, 2 mm\u003c\/li\u003e\n\u003cli\u003e2 spare glass plates, each with a diameter of 120 mm\u003c\/li\u003e\n\u003cli\u003e2 spare initial-set needles, each with a diameter of 1.13 mm\u003c\/li\u003e\n\u003cli\u003eCoarse filter sponge\u003c\/li\u003e\n\u003cli\u003eFine filter sponge\u003c\/li\u003e\n\u003cli\u003eSerial cable\u003c\/li\u003e\n\u003cli\u003eUSB \/ RS232-Adapter\u003c\/li\u003e\n\u003cli\u003ePower supply\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":53065215672631,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/autovicat-368-en-12-station-auto.webp?v=1790680094"},{"product_id":"autovicat-367-8-station-automatic-vicat-needle-apparatus","title":"AutoVicat-367 8-Station Automatic Vicat Needle Apparatus","description":"\u003ch2\u003eAutoVicat-367 8-Station Automatic Vicat Needle Apparatus\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-367 8-Station Automatic Vicat Needle Apparatus is an automated testing system designed for accurate and efficient Vicat testing of cement, gypsum, and other suitable materials. With 8 measurement stations, programmable test sequences, automatic data recording, and automated needle cleaning, the system supports consistent laboratory testing and quality control workflows.\u003c\/p\u003e\n\u003cp\u003eThe apparatus is supplied with 8 Vicat molds, glass base plates, cleaning tools, spare parts, and essential accessories, providing a complete setup for multi-sample Vicat testing.\u003c\/p\u003e\n\u003ch2\u003eAutoVicat-367 8-Station Automatic Vicat Needle Apparatus\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-367 provides an organized, multi-station solution for determining setting characteristics through automated Vicat needle penetration measurements. Its programmable operation and automatic recording functions help laboratories maintain consistent testing procedures while reducing manual intervention.\u003c\/p\u003e\n\u003ch3\u003eConfiguration\u003c\/h3\u003e\n\u003cp\u003eThe 8 measurement points, arranged in a 2 × 4 configuration, are installed in a rectangular trough. Testing can be performed in air or within a temperature-controlled water bath.\u003c\/p\u003e\n\u003cp\u003eThe water-bath configuration includes a heat exchanger and cooler to help maintain a constant test temperature. Programmable testing sequences allow test procedures to be configured according to the required testing workflow.\u003c\/p\u003e\n\u003cp\u003eDuring testing, the system automatically records:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eBeginning of setting time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEnd of setting time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSetting-time plots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePenetration test data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe plunger and Vicat needle assembly has an additional weight of 300 g with a tolerance of ±1 g. After each penetration, the Vicat needle is automatically cleaned, helping maintain consistent test conditions throughout repeated measurements.\u003c\/p\u003e\n\u003ch3\u003eKey Features\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e8-station Vicat testing configuration for multi-sample testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 × 4 measurement-point arrangement\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProgrammable testing sequences\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic recording of setting times and test data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic generation of setting plots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic Vicat needle cleaning after each penetration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting in air or temperature-controlled water bath\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eHeat exchanger and cooling system for controlled water-bath temperature\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e300 g additional plunger and Vicat needle weight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eWeight tolerance of ±1 g\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes Vicat molds, glass base plates, cleaning tools, spare parts, and essential accessories\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSuitable for laboratory testing and quality control applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eImportant Notes\u003c\/h3\u003e\n\u003cp\u003eA standard PC or laptop is required for operation and is not included in the scope of delivery.\u003c\/p\u003e\n\u003cp\u003eFor testing according to EN 480-2, the following additional items are required:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eWeight 1.0366.10\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlunger 1.0366.12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional extra cooling unit 1.0366.13 for a test temperature of 5°C\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAutoVicat-367 8-Station Automatic Vicat Needle Apparatus Technical Specifications:\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H) \u003c\/td\u003e\n\u003ctd\u003e700 x 600 x 600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e110 - 230 V \/ 50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScope of delivery\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBase unit provided as a table model with the control unit\u003c\/li\u003e\n\u003cli\u003eStandard software for programmable test sequences and data recording\u003c\/li\u003e\n\u003cli\u003e8 Vicat molds (conical hard plastic rings) measuring 70\/80 mm in diameter and 40 mm in height\u003c\/li\u003e\n\u003cli\u003e8 glass base plates, each with a diameter of 120 mm\u003c\/li\u003e\n\u003cli\u003e8 centerings for Vicat molds (conical hard plastic rings) measuring 70\/80 mm in diameter and 40 mm in height\u003c\/li\u003e\n\u003cli\u003e2 pairs of cleaning brushes\u003c\/li\u003e\n\u003cli\u003e1 tee wrench, 1.25 mm\u003c\/li\u003e\n\u003cli\u003e1 tee wrench, 2 mm\u003c\/li\u003e\n\u003cli\u003e2 spare glass plates, each with a diameter of 120 mm\u003c\/li\u003e\n\u003cli\u003e2 spare initial-set needles, each with a diameter of 1.13 mm\u003c\/li\u003e\n\u003cli\u003eCoarse filter sponge\u003c\/li\u003e\n\u003cli\u003eFine filter sponge\u003c\/li\u003e\n\u003cli\u003eSerial cable\u003c\/li\u003e\n\u003cli\u003eUSB \/ RS232-Adapter\u003c\/li\u003e\n\u003cli\u003eMains cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":53065218916663,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/autovicat-367-8-station-automati.webp?v=1790680350"},{"product_id":"autovicat-366-6-station-automatic-vicat-needle-apparatus","title":"AutoVicat-366 6-Station Automatic Vicat Needle Apparatus","description":"\u003ch2\u003eAutoVicat-366 6-Station Automatic Vicat Needle Apparatus\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-366 6-Station Automatic Vicat Needle Apparatus is designed for automated Vicat testing in accordance with EN 480-2. With six measuring stations arranged in a 2 × 3 configuration, the system supports controlled testing of setting behavior in cement, mortar, and related materials.\u003c\/p\u003e\n\u003cp\u003eAn optional additional cooling unit is available for maintaining a test temperature of 5°C when required by the testing procedure. The system also includes an additional weight and plunger to support accurate penetration measurements. A standard PC or laptop is required for operation and is not included with the apparatus.\u003c\/p\u003e\n\u003ch2\u003eConfiguration\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-366 features six measuring points arranged in a 2 × 3 grid inside a rectangular trough. Testing can be performed either in air or in a temperature-controlled water bath.\u003c\/p\u003e\n\u003cp\u003eA heat exchanger and cooling system help maintain the required water temperature during testing. The apparatus can execute programmed test sequences, providing a structured and automated testing process.\u003c\/p\u003e\n\u003cp\u003eDuring operation, the system automatically records:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eInitial setting time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFinal setting time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSetting-time data\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSetting curves and plots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe Vicat needle and plunger assembly are supplemented with an additional 300 g ± 1 g weight. After each penetration, the Vicat needle is automatically cleaned to prepare it for the next measurement.\u003c\/p\u003e\n\u003ch2\u003eEN 480-2 Configuration Requirements\u003c\/h2\u003e\n\u003cp\u003eFor testing according to EN 480-2, the following components are required:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eAdditional weight: 1.0366.10\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlunger: 1.0366.12\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional extra cooling unit: 1.0366.13, required when a test temperature of 5°C is needed\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe additional cooling unit helps achieve and maintain the specified 5°C testing temperature.\u003c\/p\u003e\n\u003ch2\u003ePC and Laptop Requirement\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-366 requires a standard PC or laptop for operation and test control. The computer is not included in the scope of delivery.\u003c\/p\u003e\n\u003ch2\u003eKey Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eSix-station automatic Vicat testing system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eDesigned according to EN 480-2 requirements\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSix measuring points in a 2 × 3 configuration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTesting in air or controlled-temperature water bath\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProgrammable test sequences\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic recording of initial and final setting times\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic generation of setting plots\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdditional 300 g ± 1 g weight\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomatic Vicat needle cleaning after penetration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOptional cooling unit for 5°C testing\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eRequires a standard PC or laptop for operation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAutoVicat-366 6-Station Automatic Vicat Needle Apparatus Technical Specifications:\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e700 x 600 x 600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e52 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e110 - 230 V \/ 50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScope of Delivery\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBase unit: Table model featuring the control unit and standard software for programmable test sequences and data recording.\u003c\/li\u003e\n\u003cli\u003e6 Vicat moulds: Conical hard plastic rings, each measuring 70\/80 mm in diameter and 40 mm in height.\u003c\/li\u003e\n\u003cli\u003e6 glass base plates: Diameter of 120 mm.\u003c\/li\u003e\n\u003cli\u003e6 centerings for Vicat moulds: Conical hard plastic rings, each measuring 70\/80 mm in diameter and 40 mm in height.\u003c\/li\u003e\n\u003cli\u003e1 pair of cleaning brushes.\u003c\/li\u003e\n\u003cli\u003e1 tee wrench: Size 1.25 mm.\u003c\/li\u003e\n\u003cli\u003e1 tee wrench: Size 2 mm.\u003c\/li\u003e\n\u003cli\u003e2 spare glass plates: Diameter of 120 mm each.\u003c\/li\u003e\n\u003cli\u003e2 spare initial-set needles: Diameter of 1.13 mm each.\u003c\/li\u003e\n\u003cli\u003eFilter sponge: Coarse.\u003c\/li\u003e\n\u003cli\u003eFilter sponge: Fine.\u003c\/li\u003e\n\u003cli\u003eSerial cable.\u003c\/li\u003e\n\u003cli\u003eUSB\/RS232-Adapter.\u003c\/li\u003e\n\u003cli\u003eMains cable.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv id=\"gtx-trans\"\u003e\n\u003ch2 class=\"gtx-trans-icon\"\u003e \u003c\/h2\u003e\n\u003c\/div\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":53065231892791,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/autovicat-366-6-station-automati.webp?v=1790680569"},{"product_id":"autovicat-368-astm-12-station-automatic-vicat-needle-apparatus-for-cement","title":"AutoVicat-368-ASTM 12 Station Automatic Vicat Needle Apparatus (For Cement)","description":"\u003ch2\u003eAutoVicat-368-ASTM 12 Station Automatic Vicat Needle Apparatus for Cement\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-368-ASTM 12 Station Automatic Vicat Needle Apparatus is designed for automated Vicat testing of cement. With 12 integrated measuring stations, programmable test sequences, automatic data recording, and controlled high-humidity conditions, the system provides a consistent approach to determining cement setting behavior.\u003c\/p\u003e\n\u003cp\u003eThe 12 measuring stations are arranged in a 4\/4\/4 rectangular configuration within a stainless steel testing tub, which is seamlessly integrated into a durable stainless steel work table.\u003c\/p\u003e\n\u003cp\u003eThe complete testing sequence can be programmed through the PC-controlled software, allowing automated test execution and evaluation. Testing takes place in a high-humidity environment with more than 95% moist air to support controlled testing conditions.\u003c\/p\u003e\n\u003cp\u003eDuring testing, the system automatically records the start and end of solidification and generates detailed solidification curves for analysis and evaluation.\u003c\/p\u003e\n\u003cp\u003eThe drop rod and Vicat needle assembly has a precise total weight of 300 g ± 1 g, supporting consistent penetration measurements throughout the test sequence.\u003c\/p\u003e\n\u003cp\u003eFor improved testing consistency, a built-in automatic cleaning device cleans the Vicat needle after each penetration. This helps maintain a clean needle tip and supports repeatable measurements across multiple test cycles.\u003c\/p\u003e\n\u003ch2\u003eScope of Delivery\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-368-ASTM is supplied as a complete system mounted in a stainless steel cabinet, with the following components and accessories:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eDevice mounted in a stainless steel cabinet\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eStandard software for test execution and evaluation on a Windows operating system\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePC-based test control and evaluation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e12 × Vicat rings (Ø 60\/70 mm × 40 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e12 × glass plates (Ø 120 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e12 × centering rings for Vicat rings (Ø 60\/70 mm × 40 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 pairs of replacement cleaning brushes\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Allen key (1.25 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e1 × Allen key (2 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 × replacement glass plates (Ø 120 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e2 × replacement needles (Ø 1.0 mm)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSerial cable\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUSB\/RS232 adapter\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePower supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePC Requirement\u003c\/h3\u003e\n\u003cp\u003eA standard PC or laptop is required to operate the apparatus and run the Windows-based testing software. The PC or laptop is not included in the delivery scope.\u003c\/p\u003e\n\u003ch2\u003eAutoVicat-368-ASTM 12 Station Automatic Vicat Needle Apparatus (For Cement) Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e1000 x 700 x 1140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e195 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e110 - 230 V \/ 50 - 60 Hz \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv id=\"gtx-trans\"\u003e\n\u003cdiv class=\"gtx-trans-icon\"\u003e \u003c\/div\u003e\n\u003c\/div\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":53065241362743,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/autovicat-368-astm-12-station-au.webp?v=1790680750"},{"product_id":"autovicat-368-gz-12-station-automatic-vicat-needle-apparatus-for-gypsum-cement-paste","title":"AutoVicat-368-GZ 12-Station Automatic Vicat Needle Apparatus (For Gypsum \u0026 Cement Paste)","description":"\u003ch2\u003eAutoVicat-368-GZ 12-Station Automatic Vicat Needle Apparatus (For Gypsum \u0026amp; Cement Paste)\u003c\/h2\u003e\n\u003cp\u003eThe AutoVicat-368-GZ 12-Station Automatic Vicat Needle Apparatus is designed for testing gypsum and cement paste. It provides precise control with programmable test sequences and automatic data recording for efficient laboratory testing. The apparatus is supplied with Vicat moulds, glass base plates, cleaning brushes, spare parts, and essential accessories for comprehensive testing.\u003c\/p\u003e\n\u003ch2\u003eAutoVicat-368-GZ 12-Station Automatic Vicat Needle Apparatus\u003c\/h2\u003e\n\u003cp\u003eAccording to EN 196-3, EN 480-2*, EN 13279-2, and DIN 1168, tests can be performed either in air or in a water bath with a consistent temperature. A heat exchanger and cooler can be used to maintain a constant water temperature during testing. The beginning and end of setting time, along with setting plots, can be automatically recorded.\u003c\/p\u003e\n\u003ch3\u003eConfiguration\u003c\/h3\u003e\n\u003cp\u003eThe six measuring points (2 x 4) are positioned in a rectangular trough with programmed test sequences.\u003c\/p\u003e\n\u003cp\u003eFor gypsum and cement testing, the following drop bars and weights are included with the equipment:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eCement: The combined weight of the drop bar and Vicat needle is 300 g ± 1 g. For tests with 1000 g, the weight is 700 g.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePlaster: The combined weight of the drop bar and the additional weight for the consistency plunger is 100 g.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAdditional Weight: An additional 300 g ± 1 g weight is provided for the plunger and the Vicat needle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAfter each penetration, the Vicat needle is automatically cleaned.\u003c\/p\u003e\n\u003ch3\u003eImportant Note\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eA standard PC with a monitor or laptop is required to operate the apparatus and is not included in the package.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFor compliance with EN 480-2, the additional weight 1.0366.10, plunger 1.0366.12, and optionally the additional cooling unit 1.0366.13 for maintaining a test temperature of 5°C are necessary.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAutoVicat-368-GZ 12-Station Automatic Vicat Needle Apparatus (For Gypsum \u0026amp; Cement Paste) Technical Specifications:\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"1\" cellspacing=\"1\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension (W x D x H)\u003c\/td\u003e\n\u003ctd\u003e700 x 600 x 600 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e62 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e110 - 230 V \/ 50 - 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eScope of delivery\u003c\/td\u003e\n\u003ctd\u003e\n\u003cul\u003e\n\u003cli\u003eBase unit designed as a table model with the control unit and standard software for programmable test sequences and data recording\u003c\/li\u003e\n\u003cli\u003e12 Vicat moulds (conical hard plastic ring) with dimensions 70\/80 dia. x 40 mm\u003c\/li\u003e\n\u003cli\u003e12 Vicat moulds (conical hard plastic ring) with dimensions 65\/75 dia. x 40 mm\u003c\/li\u003e\n\u003cli\u003e12 glass base plates with a diameter of 120 mm\u003c\/li\u003e\n\u003cli\u003e12 centerings for Vicat moulds (conical hard plastic ring) with dimensions 70\/80 dia. x 40 mm\u003c\/li\u003e\n\u003cli\u003e12 centerings for Vicat moulds (conical hard plastic ring) with dimensions 65\/75 dia. x 40 mm\u003c\/li\u003e\n\u003cli\u003e2 pairs of cleaning brushes\u003c\/li\u003e\n\u003cli\u003e1 tee wrench with a size of 1.25 mm\u003c\/li\u003e\n\u003cli\u003e1 tee wrench with a size of 2 mm\u003c\/li\u003e\n\u003cli\u003e2 spare glass plates with a diameter of 120 mm\u003c\/li\u003e\n\u003cli\u003e2 spare initial-set needles with a diameter of 1.13 mm\u003c\/li\u003e\n\u003cli\u003e1 replacement cone\u003c\/li\u003e\n\u003cli\u003eCoarse filter sponge\u003c\/li\u003e\n\u003cli\u003eFine filter sponge\u003c\/li\u003e\n\u003cli\u003eSerial cable\u003c\/li\u003e\n\u003cli\u003eUSB\/RS232-Adapter\u003c\/li\u003e\n\u003cli\u003eMains cable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cdiv id=\"gtx-trans\"\u003e\n\u003ch2 class=\"gtx-trans-icon\"\u003e \u003c\/h2\u003e\n\u003c\/div\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":53065250341175,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/autovicat-368-gz-12-station-auto.webp?v=1790681000"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/collections\/automatic-vicat-needle-apparatus_1.webp?v=1790679525","url":"https:\/\/qualitest.us\/fr\/collections\/automatic-vicat-needle-apparatus-multi-station-pc-controlled-for-cement-gypsum.oembed","provider":"Qualitest USA LC","version":"1.0","type":"link"}