{"product_id":"oil-particle-counter","title":"Oil Particle Counter","description":"\u003ch2\u003eOil Particle Counter – QualiOPC™ 1000\u003c\/h2\u003e\n\u003cp\u003eQualiOPC™ 1000 is a desktop Oil Particle Counter designed for accurate fluid cleanliness evaluation across a wide range of oils and compatible liquids. It measures the size and concentration of insoluble solid particles to support contamination assessment, predictive maintenance planning, and fluid condition monitoring.\u003c\/p\u003e\n\u003cp\u003eBuilt around the light-blocking measurement principle, the system performs contamination analysis for hydraulic oil, lubricating oil, shale oil, transformer oil, turbine oil, gear oil, engine oil, aviation kerosene, water-based hydraulic fluids, organic liquids, and polymer solutions. The platform delivers fast and consistent particle analysis to help laboratories maintain reliable testing workflows.\u003c\/p\u003e\n\u003cp\u003eThis desktop Oil Particle Counter integrates a semiconductor laser with a broad particle-size detection range, enabling detailed cleanliness evaluation across different fluid conditions. Multiple reporting standards, Windows-based instrument control, and integrated data management features support efficient operation and streamlined reporting.\u003c\/p\u003e\n\u003cp\u003eDesigned for demanding environments across military, aerospace, power generation, and transportation sectors, QualiOPC™ 1000 supports fluid cleanliness programs where equipment performance and operational reliability are closely linked to contamination control.\u003c\/p\u003e\n\u003cp\u003eThe system combines a high-capacity particle counting sensor with a controlled sampling mechanism to generate repeatable measurement results across an extended particle range. An industrial computer with Windows supports instrument operation, calculations, internal database storage, printer connectivity, and USB-based data export for convenient record management.\u003c\/p\u003e\n\u003ch2\u003eOil Particle Counter - QualiOPC™ 1000 Applications\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/o1-1166380177.webp?v=1779378029\" alt=\"Oil Particle Counter\"\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHydraulic and Lubricating Oil Monitoring:\u003c\/strong\u003e QualiOPC™ 1000 supports contamination monitoring across hydraulic oil, lubricating oil, turbine oil, gear oil, engine oil, and other service fluids. By measuring particle concentration and distribution, it helps maintenance teams identify contamination trends earlier and make informed decisions regarding fluid condition and equipment performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTransformer and Insulating Oil Analysis:\u003c\/strong\u003e QualiOPC™ 1000 is also suitable for transformer and insulating oil cleanliness evaluation. Particle monitoring in these fluids supports improved reliability of electrical systems by helping identify contamination that may influence insulation performance and operating stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAerospace and Defense Fluid Cleanliness:\u003c\/strong\u003e The system supports fluid cleanliness programs in aerospace and defense applications where hydraulic fluids, lubricants, and fuel-related systems require controlled contamination levels to maintain operational reliability and extend service intervals.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower and Transportation Industries:\u003c\/strong\u003e QualiOPC™ 1000 is suitable for power generation and transportation environments where fluid cleanliness is part of ongoing maintenance practices. Typical applications include turbine lubrication systems, rail and marine operations, and heavy-duty hydraulic and lubrication circuits requiring routine contamination tracking.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOrganic Liquids and Polymer Solutions:\u003c\/strong\u003e In addition to conventional oil analysis, QualiOPC™ 1000 can measure insoluble particles in organic liquids and polymer solutions. This broadens application flexibility for laboratories and industrial environments handling specialty fluids and process-related liquid testing.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/o2-732530930.webp?v=1779378027\" alt=\"Oil Particle Counter\"\u003e\u003c\/p\u003e\n\u003ch2\u003eStandards Compliance\u003c\/h2\u003e\n\u003cp\u003eQualiOPC™ 1000 supports recognized international cleanliness and particle analysis standards to help laboratories maintain consistent testing methods and standardized reporting across different industries and fluid applications.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eISO 4402\u003c\/strong\u003e – Hydraulic fluid power standard covering calibration methods for automatic particle counting instruments used to measure particles suspended in liquids.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eISO 11171\u003c\/strong\u003e – Standard for calibration of automatic liquid particle counters to support accurate and repeatable contamination measurement.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eISO 4406\u003c\/strong\u003e – Hydraulic fluid cleanliness coding standard used to classify contamination levels based on particle counts.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eNAS 1638\u003c\/strong\u003e – Aerospace fluid cleanliness classification standard for evaluating particulate contamination in hydraulic systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSAE AS4059E \/ SAE AS4059F \/ SAE AS4059FI\u003c\/strong\u003e – Aerospace cleanliness classification standards for reporting and controlling contamination levels in fluid systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eSAE ARP749D\u003c\/strong\u003e – Recommended aerospace practice focused on hydraulic fluid cleanliness control and contamination management procedures.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003e\u003cstrong\u003eGOST 17216\u003c\/strong\u003e – Particle contamination classification standard available as an optional reporting format for applicable testing requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese supported standards allow QualiOPC™ 1000 to align particle counting results with industry-recognized cleanliness classifications for maintenance, quality control, and condition monitoring programs.\u003c\/p\u003e\n\u003ch2\u003eOil Particle Counter – QualiOPC™ 1000 Key Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eMeasures particle size and concentration in liquids using the light-blocking measurement principle for reliable contamination analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eCalibration methodology, particle detection, and measurement performance are aligned with ISO 4402 and ISO 11171 requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eSupports integrated cleanliness classification and reporting formats including NAS 1638, ISO 4406 series, SAE AS4059, GOST 17216, SAE ARP749D, AETF1A, and combined NAS 1638 \/ ISO 4406 reporting options.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFeatures a high-sensitivity, large-range particle counting sensor designed for accurate particle detection across varied fluid conditions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIncludes an industrial computer with a Windows operating system for instrument management, calculations, data analysis, and reporting functions.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eOffers optional calibration curve selections including ACFTD, ISOMTD, latex sphere, and GOST reference curves to support different testing requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eTest results can be stored and exported through integrated printer output, internal software database management, and USB flash drive storage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eProvides broad particle measurement capability with detection coverage from 0.8 μm to 500 μm, with reporting ranges of 1–100 μm under ISO 4402 or 4–70 μm(c) under ISO 11171 calibration.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eControlled sampling and cleaning processes support stable and repeatable testing performance across routine measurement workflows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated pressure and vacuum handling capabilities assist with sample preparation, support higher-viscosity fluids, and reduce air bubble interference during analysis.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/o3-1440292250.webp?v=1779378026\" alt=\"Oil Particle Counter\"\u003e\u003c\/p\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003eQualiOPC™ 1000 operates using the light-blocking method, also known as the light obscuration principle, for measuring particle contamination in liquids. During analysis, particles suspended within the sample pass through a detection zone and partially interrupt a focused laser beam. The system captures these signal variations and converts them into particle size and particle count data as the sample moves through the measurement path.\u003c\/p\u003e\n\u003cp\u003eThis measurement principle is widely recognized for liquid particle analysis because it provides direct evaluation of contamination levels in oils and other compatible fluids. By analyzing the interaction between particles and the laser source, the instrument generates consistent cleanliness data across a broad particle range.\u003c\/p\u003e\n\u003cp\u003eQualiOPC™ 1000 combines this optical detection process with controlled sample handling, regulated flow conditions, and defined sample volumes to support stable and repeatable measurements. Integrated calibration options and support for recognized cleanliness classification standards allow results to be generated in reporting formats that align with laboratory procedures, maintenance programs, and industry-specific monitoring requirements.\u003c\/p\u003e\n\u003ch2\u003eOil Particle Counter - QualiOPC™ 1000 Technical Specification\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eQualiOPC™ 1000\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eProduct Name\u003c\/td\u003e\n\u003ctd\u003eOil Particle Counter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eModel\u003c\/td\u003e\n\u003ctd\u003eQualiOPC™ 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight Source\u003c\/td\u003e\n\u003ctd\u003eSemiconductor laser\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Principle\u003c\/td\u003e\n\u003ctd\u003eLight-blocking method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Range\u003c\/td\u003e\n\u003ctd\u003e0.8–500 μm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParticle Size Range\u003c\/td\u003e\n\u003ctd\u003e1–100 μm (ISO 4402) or 4–70 μm(c) (ISO 11171)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensitivity\u003c\/td\u003e\n\u003ctd\u003e1 μm (ISO 4402) or 4 μm(c)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Channels\u003c\/td\u003e\n\u003ctd\u003e32 channels, particle size can be set in 0.01 μm increments\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume\u003c\/td\u003e\n\u003ctd\u003e0.3–100 mL, 0.1 mL interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Volume Relative Error\u003c\/td\u003e\n\u003ctd\u003eBetter than ±0.5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Speed\u003c\/td\u003e\n\u003ctd\u003e5–60 mL\/min, default 15 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCleaning Speed\u003c\/td\u003e\n\u003ctd\u003e5–60 mL\/min, default 15 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eBetter than 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCoincidence Error Limit\u003c\/td\u003e\n\u003ctd\u003e12,000–40,000 particles\/mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCounting Repeatability\u003c\/td\u003e\n\u003ctd\u003eRSD \u0026lt; 2%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDetection Accuracy\u003c\/td\u003e\n\u003ctd\u003e±4.5 rating under ISO 4406 standard listing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eParticle Count Relative Error\u003c\/td\u003e\n\u003ctd\u003e±5%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Chamber Pressure\u003c\/td\u003e\n\u003ctd\u003eMaximum positive pressure 0.8 MPa; maximum vacuum -0.08 MPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Viscosity Range\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;650 cSt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Temperature\u003c\/td\u003e\n\u003ctd\u003e0–80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e-20 to 60°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-30 to 80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e220 V ±10%, 50 Hz (110V is also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd\u003e180 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e355 × 400 × 620 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e19 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52178357551415,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/oil-particle-counter771516043.webp?v=1779377998","url":"https:\/\/qualitest.us\/es\/products\/oil-particle-counter","provider":"Qualitest USA LC","version":"1.0","type":"link"}