{"product_id":"cooling-temperature-control-system-120-to-70-c","title":"Cooling Temperature Control System (–120 to –70°C)","description":"\u003cdiv class=\"ds-virtual-list-items _6f2c522\"\u003e\n\u003cdiv class=\"ds-virtual-list-visible-items\"\u003e\n\u003cdiv class=\"_4f9bf79 d7dc56a8 _43c05b5\" data-virtual-list-item-key=\"2\"\u003e\n\u003cdiv class=\"ds-message _63c77b1\"\u003e\n\u003cdiv class=\"ds-markdown ds-assistant-message-main-content\"\u003e\n\u003ch2 class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eCooling Temperature Control System (–120 to –70°C) – QualiCool™ Series\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eFor extreme sub-zero applications, reliable temperature regulation is critical. The QualiCool™ Series low-temperature circulating chiller provides stable, repeatable cooling for closed-loop processes involving reactors, jacketed vessels, condensers, and external heat exchangers.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThis system circulates thermal fluid through your process loop while a refrigeration unit removes heat, maintaining a setpoint between –120°C and –70°C—depending on load and fluid properties.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eDesigned for laboratory and pilot-scale operations, it delivers precise low-temperature control without requiring large cryogenic installations. The unit supports uninterrupted operation, controlled ramping, and steady circulation—ensuring consistent conditions for sensitive material testing, reaction development, and thermal performance analysis.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"ds-flex _0a3d93b\"\u003e\n\u003cdiv class=\"ds-flex _965abe9 _54866f7\"\u003e\n\u003ch2 class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eCooling Temperature Control System (–120 to –70°C) – QualiCool™ Series Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eLow-Temperature Reaction Control (Jacketed Reactors):\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eDelivers a stable reaction environment for kinetic studies and efficient heat dissipation during exothermic stages—especially valuable when sub-zero conditions improve reaction selectivity and process safety.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCrystallization \u0026amp; Precipitation Processes:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eManages cooling ramp rates to refine crystal size distribution and enhance batch-to-batch consistency, particularly critical when nucleation depends on precise thermal conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCondensation \u0026amp; Cold-Trap Support:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eSupplies reliable external cooling for condensers or vapor traps, boosting solvent recovery, improving vapor containment, and reinforcing overall process stability.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMaterials \u0026amp; Polymer Testing:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eFacilitates cold conditioning, thermal cycling test rigs, and low-temperature exposure experiments—any setup that requires a controlled, circulating fluid source for material evaluation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eInstrument \u0026amp; Sensor Verification at Sub-Zero Temperatures:\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003eServes as a circulating cold source for test fixtures or heat exchangers used in calibration and performance verification routines (configurations vary by laboratory setup).\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv\u003e\n\u003ch2 class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eCooling Temperature Control System (–120 to –70°C) – QualiCool™ Series Key Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eUltra-Low Temperature Control Range\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Designed for deep sub-zero process cooling, with reliable performance across the full –120 to –70°C spectrum.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eStable Circulating Output\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Provides consistent jacket and coil temperature regulation, even during extended operation runs.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eMultiple Capacity Options\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Choose from various power levels to match cooling output to your specific load size and ramp rate requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHigh-Flow Circulation Choices\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Accommodates different pressure drop scenarios and heat exchanger configurations for flexible system integration.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eCompact, Floor-Standing Design\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Combines refrigeration and circulation components into a single, space-saving unit for streamlined installation.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eIndustrial Connection Sizing\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Offered with standard fitting options to align with common process loop plumbing dimensions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eOptional Build Configurations\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Available in select variants, including stainless steel chassis and explosion-proof constructions, depending on site needs and supplier specifications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan class=\"\"\u003e\u003cspan\u003eTheory and Method\u003c\/span\u003e\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cspan class=\"\"\u003eThe QualiCool™ Series functions as a closed-loop circulating refrigeration system, following a four-step process:\u003c\/span\u003e\u003c\/p\u003e\n\u003col start=\"1\"\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eThermal Fluid Circulation\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– A pump propels the selected heat-transfer fluid through the external process loop, which may include reactor jackets, coils, or heat exchangers.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eHeat Absorption\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– As the fluid travels through the loop, it draws heat from the user's process and returns to the unit at a warmer temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eRefrigeration Cooling\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– Inside the chiller, a refrigeration circuit and dedicated heat exchanger remove the accumulated heat from the returning fluid, restoring it to the desired temperature.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp class=\"ds-markdown-paragraph\"\u003e\u003cstrong\u003e\u003cspan class=\"\"\u003eActive Control Loop\u003c\/span\u003e\u003c\/strong\u003e\u003cspan class=\"\"\u003e\u003cspan\u003e \u003c\/span\u003e– A temperature controller (typically PID-based) continuously monitors system conditions and adjusts compressor activity, valve positions, and circulation behavior to maintain the target setpoint—even as process loads fluctuate.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch2\u003eCooling Temperature Control System (–120 to –70°C) – QualiCool™ Series Technical Specification\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eQualiCool™ 30\u003c\/th\u003e\n\u003cth\u003eQualiCool™ 55\u003c\/th\u003e\n\u003cth\u003eQualiCool™ 95\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemp Range (°C)\u003c\/td\u003e\n\u003ctd\u003e-120 to -70\u003c\/td\u003e\n\u003ctd\u003e-120 to -70\u003c\/td\u003e\n\u003ctd\u003e-120 to -70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Power (kW)\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Power @20°C (kW)\u003c\/td\u003e\n\u003ctd\u003e0.3\u003c\/td\u003e\n\u003ctd\u003e0.55\u003c\/td\u003e\n\u003ctd\u003e0.95\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Flow (L\/min)\u003c\/td\u003e\n\u003ctd\u003e20\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003ctd\u003e35\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax Pressure (bar)\u003c\/td\u003e\n\u003ctd\u003e0.7\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003ctd\u003e1.0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Dimensions L×W×H (mm)\u003c\/td\u003e\n\u003ctd\u003e550 × 700 × 1650\u003c\/td\u003e\n\u003ctd\u003e700 × 800 × 1650\u003c\/td\u003e\n\u003ctd\u003e700 × 800 × 1650\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e380V\/50Hz~3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52668092219703,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/cooling-temperature-control-system-120-70degc1555821934.webp?v=1784100062","url":"https:\/\/qualitest.us\/es\/products\/cooling-temperature-control-system-120-to-70-c","provider":"Qualitest USA LC","version":"1.0","type":"link"}