{"title":"Free Lime Analyzer","description":"\u003ch2\u003eFree Lime Analyzer – Advanced Solutions for Accurate Lime Measurement\u003c\/h2\u003e\n\u003cp\u003eA Free Lime Analyzer is widely used in the cement, steel, and related industries to determine the free lime (CaO) content in materials such as clinker, cement, and steel slag. Precise free lime measurement plays a vital role in quality control, process efficiency, and meeting industry standards across production environments.\u003c\/p\u003e\n\u003cp\u003eReliable free lime testing supports better process optimization, helps maintain consistent product quality, and contributes to reduced energy usage during manufacturing. Real-time analytical results allow operators to monitor production more effectively and make informed adjustments when needed.\u003c\/p\u003e\n\u003cp\u003eOur advanced Free Lime Analyzers are engineered for high precision, fast analysis, and simple operation, making them suitable for both laboratory environments and industrial process control. From cement production lines improving clinker quality to steel facilities managing slag chemistry, these systems deliver consistent and dependable performance for better efficiency and cost control.\u003c\/p\u003e","products":[{"product_id":"free-lime-analyzer-qualicao-i","title":"Free Lime Analyzer - QualiCaO™ I","description":"\u003ch2\u003eFree Lime Analyzer QualiCaO™ I\u003c\/h2\u003e\n\u003cp\u003eThe Free Lime Analyzer QualiCaO™ I is engineered to evaluate the quality of cement and clinker calcination within thermal processing systems. It operates using an ethylene glycol extraction combined with a benzoic acid direct titration technique, enabling rapid and highly accurate determination of free lime content within approximately three minutes.\u003c\/p\u003e\n\u003cp\u003eThis system is well-suited for cement manufacturing process monitoring, materials research studies, and academic laboratory applications, ensuring reliable and consistent analytical results for quality control and process optimization.\u003c\/p\u003e\n\u003ch2\u003eFree Lime Analyzer QualiCaO™ I Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003eStepless adjustment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003eStandard deviation is 0.064%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eExtraction time\u003c\/th\u003e\n\u003ctd\u003e3 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e220V \/ 50HZ (110V is also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e300 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAverage temperature speed\u003c\/th\u003e\n\u003ctd\u003e60 ℃ \/ min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eAccessories\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e250 ml Erlenmeyer flask:1 piece\u003c\/li\u003e\n\u003cli\u003eMagnetic stir bar: 1 piece\u003c\/li\u003e\n\u003cli\u003eCondenser tube: 1 piece\u003c\/li\u003e\n\u003cli\u003ePlastic pipe: 2 meter\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52008332788023,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/free-lime-analyzer-qualicao-i201418322.webp?v=1776698559"},{"product_id":"free-lime-analyzer-qualicao-ii","title":"Free Lime Analyzer QualiCaO™ II","description":"\u003ch2\u003eFree Lime Analyzer QualiCaO™ II\u003c\/h2\u003e\n\u003cp\u003eThe Free Lime Analyzer QualiCaO™ II is an advanced solution for precise cement quality assessment, specifically designed for rapid measurement of fCaO (free calcium oxide). Accurate monitoring of free lime is essential for maintaining consistent cement quality and process stability in production environments.\u003c\/p\u003e\n\u003cp\u003eThis system measures fCaO using electrical conductivity technology, removing inaccuracies associated with traditional titration techniques and improving overall measurement reliability. The fully automated testing process delivers results within minutes, supporting fast and efficient quality control operations.\u003c\/p\u003e\n\u003cp\u003eWith features such as automatic result display, printing, and alarm notifications, the QualiCaO™ II reduces manual workload and testing time while enhancing operational efficiency. It serves as a reliable tool for maintaining consistent production standards and improving overall process control.\u003c\/p\u003e\n\u003ch2\u003eFree Lime Analyzer QualiCaO™ II Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003ctd\u003e220V\/50HZ (110V is also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMotor\u003c\/th\u003e\n\u003ctd\u003eStepless adjust\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003ctd\u003e500W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWork environment temperature\u003c\/th\u003e\n\u003ctd\u003e5~40℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWorking condition relative humidity\u003c\/th\u003e\n\u003ctd\u003e50~85%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTime\u003c\/th\u003e\n\u003ctd\u003e1~99 minutes (default 5 minutes)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature\u003c\/th\u003e\n\u003ctd\u003e0~99℃ (default 80℃)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature error\u003c\/th\u003e\n\u003ctd\u003e±1℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConductivity type\u003c\/th\u003e\n\u003ctd\u003eDJS-1 type platinum black electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrode constant\u003c\/th\u003e\n\u003ctd\u003eConstant is 1, the electrode with 0.9-1.1 range are in constant on 1 range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eMeasuring range\u003c\/th\u003e\n\u003ctd\u003efCaO within 4.0%, but more than 3.0% have exceeded according to the national standards\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003e5 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrical conductivity\u003c\/th\u003e\n\u003ctd\u003e0 ~ 2000 μs\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConductance resolution\u003c\/th\u003e\n\u003ctd\u003e1 μs\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAccuracy\u003c\/th\u003e\n\u003ctd\u003e1 μs\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eAverage speed\u003c\/th\u003e\n\u003ctd\u003e5 ℃ \/ min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52008369979703,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/free-lime-analyzer-qualicao-ii758110762.webp?v=1776698923"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/collections\/free-lime-analyzer1258908671.webp?v=1776698409","url":"https:\/\/qualitest.us\/es\/collections\/free-lime-analyzer.oembed","provider":"Qualitest USA LC","version":"1.0","type":"link"}