{"title":"Vicat Needle Apparatus","description":"\u003ch2\u003eVicat Needle Apparatus for Cement, Mortar, and Gypsum Testing\u003c\/h2\u003e\n\u003cp\u003eThe Vicat Needle Apparatus is used to determine the setting time and standard consistency of cement and mortar in quality control and cement testing laboratories. The Vicat consistency test provides a reliable method for evaluating whether cement, mortar, and gypsum meet specified requirements for consistency and setting time.\u003c\/p\u003e\n\u003cp\u003eThese test methods determine the setting time of hydraulic cement using a Vicat needle. Two testing methods are available. Test Method A uses a manually operated standard Vicat apparatus as the reference method. Test Method B allows the use of an automatic Vicat apparatus that has demonstrated acceptable performance according to the qualification requirements of the applicable method.\u003c\/p\u003e\n\u003ch3\u003eStandard Consistency of Cement\u003c\/h3\u003e\n\u003cp\u003eStandard consistency refers to the consistency of cement paste that allows the Vicat needle or plunger to penetrate to a point 5 to 7 mm from the bottom of the Vicat mould under the specified test conditions. Determining standard consistency is an essential step in cement testing and setting-time evaluation.\u003c\/p\u003e\n\u003cp\u003eQUALITEST - TESTING offers a complete range of Vicat Needle Apparatus systems, including manual, single-station semi-automatic, and fully automatic models with multiple testing stations. These systems are designed to support consistent and efficient cement, mortar, and gypsum testing in laboratory environments.\u003c\/p\u003e\n\u003ch3\u003eApplicable Standard\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eASTM C191: Standard Test Methods for Time of Setting of Hydraulic Cement by Vicat Needle\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVicat Test Measurement Principle\u003c\/h2\u003e\n\u003cp\u003eThe Vicat test measures the penetration resistance of a standardized needle or rod assembly into a fresh cementitious mixture at specified time intervals. It is used to determine the setting behavior of hydraulic cement, mortar, and gypsum as the material changes from a fluid or plastic state to a rigid, load-bearing structure.\u003c\/p\u003e\n\u003cp\u003eWhen dry cement is mixed with water, the resulting paste initially has low resistance, allowing the weighted Vicat needle assembly to penetrate deeply into the specimen. As cement hydration progresses, calcium silicate hydrate (C-S-H) products form and develop an increasingly interconnected structure within the paste.\u003c\/p\u003e\n\u003cp\u003eAs this internal structure develops, the cement paste becomes progressively stiffer and offers greater resistance to needle penetration. The Vicat apparatus records the penetration depth at defined elapsed times, allowing the initial and final setting behavior of the material to be determined through direct physical measurement.\u003c\/p\u003e\n\u003cp\u003eThis testing method provides objective data for evaluating cement setting time, consistency, and hardening characteristics, supporting quality control and specification compliance in cement and construction-material laboratories.\u003c\/p\u003e\n\u003cpre\u003e\u003ccode class=\"language-plaintext\"\u003e [ Fresh Mixture: Water + Hydraulic Cement ]\n                          │\n                          ▼\n       [ Fluid Stage: Low-Viscosity Suspension ]\n       • Needle drops completely through to the bottom plate\n                          │\n                          ▼\n       [ Setting Stage: C-S-H Gel Network Multiplies ]\n       • Internal shear yield resistance increases\n       • Needle stops at 25 mm depth (ASTM) or 4 mm from bottom (EN)\n                          │\n                          ▼\n       [ INITIAL SET: Cut-off Threshold for Placing and Finishing ]\n                          │\n                          ▼\n       [ Hardening Stage: Dense, Interlocking Solid Grid ]\n       • Needle tip penetrates ≤ 0.5 mm; outer circular ring leaves no mark\n                          │\n                          ▼\n       [ FINAL SET: Material Reaches Full Initial Rigidity ]\u003c\/code\u003e\u003c\/pre\u003e\n\u003ch2\u003eApparatus Specifications Across Standards\u003c\/h2\u003e\n\u003cp\u003eThe Qualitest Vicat range supports all major international standard configurations across manual, semi-automated, and fully computerized multi-station systems:\u003c\/p\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"8\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eComponent \/ Parameter\u003c\/th\u003e\n\u003cth\u003eASTM Cement (ASTM C187 \/ C191)\u003c\/th\u003e\n\u003cth\u003eEuropean Cement (EN 196-3 \/ ISO 9597)\u003c\/th\u003e\n\u003cth\u003eMortar Method (ASTM C807)\u003c\/th\u003e\n\u003cth\u003eGypsum and Plaster (ASTM C472 \/ EN 13279-2)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMovable Rod Assembly Mass\u003c\/td\u003e\n\u003ctd\u003e300 ± 0.5 g\u003c\/td\u003e\n\u003ctd\u003e300 ± 1.0 g\u003c\/td\u003e\n\u003ctd\u003e400 ± 0.5 g\u003c\/td\u003e\n\u003ctd\u003e100 g to 300 g depending on probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsistency Plunger\u003c\/td\u003e\n\u003ctd\u003e10.00 ± 0.05 mm polished cylinder\u003c\/td\u003e\n\u003ctd\u003e10.00 ± 0.05 mm polished cylinder\u003c\/td\u003e\n\u003ctd\u003eNot applicable\u003c\/td\u003e\n\u003ctd\u003eConical or cylindrical probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInitial Setting Needle\u003c\/td\u003e\n\u003ctd\u003e1.00 ± 0.05 mm flat metal pin\u003c\/td\u003e\n\u003ctd\u003e1.13 ± 0.05 mm round pin (1.00 mm² area)\u003c\/td\u003e\n\u003ctd\u003e2.00 ± 0.05 mm rigid pin\u003c\/td\u003e\n\u003ctd\u003eStandardized conical needle attachment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFinal Setting Attachment\u003c\/td\u003e\n\u003ctd\u003e1.00 mm flat needle tip\u003c\/td\u003e\n\u003ctd\u003e1.13 mm needle with 5.0 mm circular ring (0.5 mm recess)\u003c\/td\u003e\n\u003ctd\u003eSpecialized broad plunger\u003c\/td\u003e\n\u003ctd\u003eSurface resistance verification tip\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard Mold Geometry\u003c\/td\u003e\n\u003ctd\u003e60 mm top × 70 mm base × 40 mm conical ring\u003c\/td\u003e\n\u003ctd\u003e70 mm top × 80 mm base × 40 mm cylindrical or conical mold\u003c\/td\u003e\n\u003ctd\u003e80 mm top × 90 mm base × 40 mm brass mold\u003c\/td\u003e\n\u003ctd\u003eSpecialized cylindrical plaster mold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuring Environment\u003c\/td\u003e\n\u003ctd\u003eMoist storage cabinet (23.0 ± 2.0°C, RH ≥ 90%)\u003c\/td\u003e\n\u003ctd\u003eTemperature-controlled water bath (20.0 ± 1.0°C)\u003c\/td\u003e\n\u003ctd\u003eControlled moist room\u003c\/td\u003e\n\u003ctd\u003eControlled ambient laboratory room\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eStandardized Test Procedures\u003c\/h2\u003e\n\u003ch3\u003eNormal Consistency Determination\u003c\/h3\u003e\n\u003cp\u003eSetting time runs require establishing the standard baseline water ratio first to prevent irregular, non-compliant readings.\u003c\/p\u003e\n\u003cpre\u003e\u003ccode class=\"language-plaintext\"\u003e       [ Mix Cement and Water at a Trial Ratio ]\n                          │\n                          ▼\n       [ Pack Fresh Paste into the Mold \u0026amp; Strike Off Top Surface ]\n                          │\n                          ▼\n       [ Attach 10 mm Plunger; Lower to Exact Surface Contact ]\n                          │\n                          ▼\n       [ Release the Plunger Catch for Exactly 30 Seconds ]\n                          │\n                          ▼\n       [ Evaluate Penetration Distance: ]\n       • ASTM C187: Sinks 10 ± 1 mm below top surface\n       • EN 196-3:  Stops 6 ± 2 mm above bottom base plate\n                          │\n                 ┌────────┴────────┐\n                 ▼                 ▼\n       [ Target Value Attained ]  [ Outside Target Range ]\n                 │                 │\n                 │ (Lock in %)     │ (Adjust water dosage, mix a\n                 ▼                 │  fresh batch, and re-test)\n       [ Proceed to Setting Time ] ▼\n                                  [ Repeat Consistency Run ]\u003c\/code\u003e\u003c\/pre\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eASTM C187 Method: A 10 mm consistency plunger is positioned on the surface of the cement paste and released. The normal consistency is achieved when the plunger penetrates 10 ± 1 mm below the surface within 30 seconds.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eEN 196-3 Method: Normal consistency is achieved when the plunger stops 6 ± 2 mm above the bottom glass plate, corresponding to a penetration depth of 34 ± 2 mm.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eInitial and Final Setting Time Determination\u003c\/h3\u003e\n\u003cp\u003eOnce the standard consistency water percentage is locked in, a fresh batch is mixed. Elapsed time is tracked starting the second dry powder contacts water.\u003c\/p\u003e\n\u003cpre\u003e\u003ccode class=\"language-plaintext\"\u003e       [ Prepare Fresh Paste at Normal Consistency ]\n       (Time Zero = Point of Liquid-Powder Contact)\n                          │\n                          ▼\n       [ Position Mold in Prescribed Curing Setup ]\n       (ASTM: Moist Cabinet \/ EN: Submerged Bath)\n                          │\n                          ▼\n       [ INITIAL SETTING DETECTION ]\n       • ASTM C191: Needle settles to 25 mm depth\n       • EN 196-3:  Needle stops 4 ± 1 mm above base plate\n                          │\n                          ▼\n       [ FINAL SETTING DETECTION ]\n       • ASTM C191: Needle leaves zero complete circular mark\n       • EN 196-3:  Pin enters 0.5 mm; ring leaves no trace\u003c\/code\u003e\u003c\/pre\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eInitial Setting Time (ASTM C191): The initial setting time is reached when the 1 mm Vicat needle penetrates to a depth of 25 mm into the cement paste.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInitial Setting Time (EN 196-3): The initial setting time is reached when the 1.13 mm needle stops 4 ± 1 mm above the glass base plate.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFinal Setting Time (ASTM C191): The final setting time is identified when the 1 mm Vicat needle no longer produces a complete circular impression on the surface of the cement specimen.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFinal Setting Time (EN 196-3): The final setting time is reached when the 1.13 mm needle with the 5 mm annular attachment penetrates 0.5 mm into the cement paste, while the circular cutting ring no longer leaves an impression on the specimen surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTest Execution and Equipment Workflows\u003c\/h2\u003e\n\u003cpre\u003e\u003ccode class=\"language-plaintext\"\u003e       [ SELECTING THE TEST EXECUTION METHOD ]\n                          │\n           ┌──────────────┴──────────────┐\n           ▼                             ▼\n  [ METHOD A: Manual Testing ]  [ METHOD B: Automated Testing ]\n  • Manual drop releases        • Fully programmable drop cycles\n  • Manual needle wiping        • Integrated cleaning station\n  • Visual scale reading        • Electronic displacement logging\n           │                             │\n           │                             ▼\n           │                    [ AUTOMATED CONFIGURATIONS ]\n           │                    • Vicat306: Paper Drum Chart\n           │                    • Vicat360: Color LCD + LVDT\n           │                    • QualiVicat™ II: Auto-Clean\n           │                    • Multi-Station: Multi-Bay PC\n           │                             │\n           └──────────────┬──────────────┘\n                          │\n                          ▼\n       [ COMPLIANT TEST REPORTING \u0026amp; CURVE GENERATION ]\u003c\/code\u003e\u003c\/pre\u003e\n\u003ch3\u003eMethod A: Manual Reference Testing\u003c\/h3\u003e\n\u003cp\u003eManual Vicat Needle Apparatus \/ Consistency Tester: The manual Vicat apparatus serves as the reference setup for cement and construction-material testing according to ASTM C187, ASTM C191, ASTM C472, and EN 196-3. During testing, the operator manually releases the sliding rod at specified time intervals, reads the penetration depth from the graduated millimeter scale, and cleans the needle tip manually between measurements.\u003c\/p\u003e\n\u003ch3\u003eMethod B: Automated Vicat Testing Workflows\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eVicat306 – Single-Station with Paper Drum Recorder: Automates needle penetration at preset time intervals and records penetration depth mechanically on a rotating paper drum chart, providing a physical record of the test results.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eVicat360 – Single-Station with Color LCD Display: Uses an electronic linear variable differential transformer (LVDT) sensor to monitor needle displacement. Penetration data and curves are displayed in real time on the color LCD screen and can be exported using dedicated software.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eQualiVicat™ II – Single-Station Automated Workstation: Features motorized needle indexing to change the penetration location on the specimen after each testing cycle. An integrated cleaning and drying brush automatically cleans the needle tip between measurements, supporting unattended testing from the initial mix through the final setting stage.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eMulti-Station PC-Controlled System – High-Throughput Testing: Designed for laboratories performing multiple tests simultaneously, this system controls several testing stations through integrated PC software. Built-in temperature-controlled water baths help maintain specified testing conditions for cement (EN 196-3, ASTM C191), concrete admixtures (EN 480-2), mortar (ASTM C807), and gypsum plasters (EN 13279-2, ASTM C472).\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e","products":[{"product_id":"automatic-vicat-needle-apparatus-single-station","title":"Automatic Vicat Needle Apparatus – Single Station","description":"\u003ch2\u003eAutomatic Vicat Needle Apparatus – Single Station QualiVicat™ II\u003c\/h2\u003e\n\u003cp\u003eThe Automatic Vicat Needle Apparatus – Single Station QualiVicat™ II is a precision testing instrument designed to automatically determine the initial and final setting times of cement and mortar pastes. Advanced electronic control provides reliable operation, accurate measurements, and consistent testing performance.\u003c\/p\u003e\n\u003cp\u003eDesigned for laboratory use, the QualiVicat™ II offers a convenient and efficient testing process with automated operation and user-friendly controls. Its precise measurement capabilities make it suitable for cement setting time testing, mortar testing, and laboratory quality control.\u003c\/p\u003e\n\u003ch2\u003eAutomatic Vicat Needle Apparatus – Single Station QualiVicat™ II Features\u003c\/h2\u003e\n\u003ch3\u003eAutomatic Position Calibration\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eOne-touch automatic calibration enables precise positioning for consistent cement and mortar setting time tests.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003ePosition Storage\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe system stores calibrated positions in memory, reducing the need for repeated calibration before each test.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eAutomatic Test Process\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eA single-button operation automates penetration measurements and automatically lifts the testing components when the test is complete.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIntelligent Test Control\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eReal-time penetration displacement values are displayed during testing, reducing the need for continuous operator monitoring.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eNo Needle Replacement for Initial and Final Setting Tests\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe same needle can be used for both initial and final setting time measurements, helping reduce testing costs and manual workload.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eIntelligent Result Evaluation\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eThe system automatically evaluates test results according to specified requirements and provides prompts for subsequent testing steps.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eData Report Storage\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eTest data is automatically generated and stored in chart format for convenient review and documentation. RS485 communication and a USB port support straightforward data transfer and result management.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCore Principle of Vicat Testing\u003c\/h2\u003e\n\u003cp\u003eThe Automatic Vicat Needle Apparatus – Single Station QualiVicat™ II determines the initial and final setting times of cement paste by measuring changes in penetration resistance as hydration progresses. By automating the traditional Vicat penetration method, the system provides controlled testing and reduces the subjectivity associated with manual penetration measurements.\u003c\/p\u003e\n\u003cp\u003eThe testing principle is based on monitoring the increasing resistance of cement paste as it changes from a fresh, workable material to a progressively stiffer and hardened state. A standardized 300 g sliding assembly with a testing needle is positioned above the fresh cement paste. During the early stage of testing, the needle penetrates deeply into the specimen. As hydration progresses, the paste develops greater resistance to penetration, resulting in progressively shallower penetration depths.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eInitial Setting Time: The point at which the cement paste has stiffened sufficiently that the standardized needle no longer penetrates to the bottom of the test mold.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eFinal Setting Time: The point at which the paste has hardened sufficiently that the needle produces only a slight indentation on the specimen surface.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe QualiVicat™ II monitors penetration depth at defined time intervals and records the change in vertical displacement throughout the test. This provides a clear representation of the cement paste's setting behavior over time.\u003c\/p\u003e\n\u003ch2\u003eAutomated Test Operation and Mechanism\u003c\/h2\u003e\n\u003cp\u003eThe automated testing sequence provides controlled penetration measurements while reducing the need for repeated manual intervention during the test.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eControlled Needle Penetration: A precision stepping motor controls the movement of the weighted testing assembly, providing consistent positioning and penetration during each measurement cycle.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003ePrecision Depth Measurement: A high-precision LVDT displacement sensor measures the vertical position of the needle with a resolution of 0.01 mm, enabling accurate monitoring of penetration depth.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAutomated Result Evaluation: An integrated microprocessor controls the testing sequence, records penetration measurements at programmed intervals, and evaluates the setting-time results according to the selected testing requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eShared Needle for Initial and Final Setting Tests: The testing configuration allows the same needle to be used for both initial and final setting time measurements, simplifying the overall testing procedure and reducing component changes.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompliance with International Standards\u003c\/h2\u003e\n\u003cp\u003eThe Automatic Vicat Needle Apparatus – Single Station QualiVicat™ II is designed for cement setting time and consistency testing in accordance with recognized international testing requirements, including AASHTO T131, ASTM C187, ASTM C191, and EN 196-3.\u003c\/p\u003e\n\u003cp\u003eAs a single-station system, the apparatus tests one specimen at a time while automating the complete measurement sequence. Between penetration measurements, the specimen mold can be repositioned to help ensure that successive needle drops are performed on fresh areas of the cement paste without interfering with previous penetration points.\u003c\/p\u003e\n\u003cp\u003eDepending on the applicable testing requirements, the system can be configured with the appropriate testing accessories, including the EN 1.13 mm needle and 70\/80 mm conical mold, or an optional ASTM\/AASHTO 1 mm needle setup.\u003c\/p\u003e\n\u003ch2\u003eAutomatic Vicat Needle Apparatus – Single Station QualiVicat™ II Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetails\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime Control\u003c\/td\u003e\n\u003ctd\u003eTime display resolution: 0.1s\u003cbr\u003eTime control accuracy: ≤±0.1s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplacement\u003c\/td\u003e\n\u003ctd\u003eUsing High-precision LVDT displacement sensor, split structure, no friction then the needle falls.\u003cbr\u003eRange: 0-50mm\u003cbr\u003eDisplacement display resolution: 0.01mm\u003cbr\u003eRelative displacement accuracy: 0.1mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage\u003c\/td\u003e\n\u003ctd\u003e200 sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlide Assembly\u003c\/td\u003e\n\u003ctd\u003e300g ± 1g (including test rod\/test needle), meets the requirements of the standard.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCommunication Port\u003c\/td\u003e\n\u003ctd\u003eRS485 data output port\u003cbr\u003eUSB data export interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccessories\u003c\/td\u003e\n\u003ctd\u003eSupporting glass plate\u003cbr\u003eΦ10 mm Consistency plunger\u003cbr\u003eΦ1.13 mm needle and Φ70\/80mm conical mold to EN\u003cbr\u003e(Φ1 mm needle and Φ60\/70mm conical mould to ASTM\/AASHTO optional)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e390mm × 310mm × 575mm (L × W × H)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e220±10%VAC\/50Hz; maximum 40W (110V is also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":53065199419703,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/automatic-vicat-needle-apparatus.webp?v=1790679106"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/collections\/Vicat-Needle-Apparatus.webp?v=1790678891","url":"https:\/\/qualitest.us\/collections\/vicat-needle-apparatus.oembed","provider":"Qualitest USA LC","version":"1.0","type":"link"}