{"title":"Probe Ultrasonicator","description":"\u003ch2\u003eProbe Ultrasonicator\u003c\/h2\u003e\n\u003cp\u003eThe QualiUltra™ Probe Ultrasonicator range uses ultrasonic cavitation to break cells, disperse particles, and homogenize liquids with precise energy control. This system concentrates acoustic power at a titanium probe tip, generating strong shear forces and efficient micro-mixing for fast, consistent processing in R\u0026amp;D and quality control environments.\u003c\/p\u003e\n\u003ch2\u003eKey Applications of a Probe Ultrasonicator\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eCell and tissue lysis: Enables extraction of proteins, enzymes, DNA\/RNA, and other intracellular materials from animal, plant, and microbial samples.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eMicrobial disruption: Breaks down bacterial and viral structures for analytical work, extraction, and research studies.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eEmulsification: Creates stable emulsions where uniform droplet size is critical for formulation performance.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eNanomaterial and pigment dispersion: Enhances deagglomeration, resulting in consistent suspensions and improved repeatability.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eParticle size reduction and homogenization: Supports uniform processing of heterogeneous samples and multi-phase systems.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eComparison Table: Which Probe Ultrasonicator Fits the Workflow?\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003cth\u003eWhat it’s built for\u003c\/th\u003e\n\u003cth\u003eWorkflow advantages\u003c\/th\u003e\n\u003cth\u003eTypical control features\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiUltra™ Probe Series\u003c\/td\u003e\n\u003ctd\u003eGeneral-purpose probe sonication\u003c\/td\u003e\n\u003ctd\u003eBroad probe\/volume flexibility for common lab tasks\u003c\/td\u003e\n\u003ctd\u003ePower, time, duty cycle, temperature alarms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiUltra™ Intre Series\u003c\/td\u003e\n\u003ctd\u003eIntegrated, space-efficient operation\u003c\/td\u003e\n\u003ctd\u003eEnclosure + lifting system reduces setup friction and bench clutter\u003c\/td\u003e\n\u003ctd\u003eTouchscreen, temperature alarms, electric lifting (remote-capable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiUltra™ Smart Series\u003c\/td\u003e\n\u003ctd\u003eMethod standardization and stability\u003c\/td\u003e\n\u003ctd\u003eAutomatic tracking helps consistency under changing loads; stored programs for repeat runs\u003c\/td\u003e\n\u003ctd\u003eFrequency tracking, impedance adaptation, program storage, diagnostics\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhy Choose QualiUltra™ for Probe Ultrasonicator Applications?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eConsistent results across workflows: Advanced controls and precise parameter settings support reproducible outcomes across different teams and routine lab processes.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFlexible system configurations: Available in benchtop, enclosed, and smart-controlled setups to suit varying lab environments and workflow requirements.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eTemperature-controlled operation: Built-in monitoring and alert systems help maintain stable conditions and reduce the risk of sample degradation during extended sonication.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdaptable probe options: A range of probe diameters allows accurate energy delivery based on sample volume, viscosity, and processing goals.\u003c\/li\u003e\n\u003c\/ul\u003e","products":[{"product_id":"probe-ultrasonicator-qualiultra-probe-series","title":"Probe Ultrasonicator – QualiUltra™ Probe Series","description":"\u003ch2\u003eProbe Ultrasonicator – QualiUltra™ Probe Series\u003c\/h2\u003e\n\u003cp\u003eThe QualiUltra™ Probe Series Probe Ultrasonicator delivers high-intensity ultrasonic cavitation for efficient cell disruption, particle dispersion, and liquid homogenization with precise, repeatable control. Adjustable power and timing settings allow labs to fine-tune energy input for delicate biomaterials, dense tissues, and challenging suspensions.\u003c\/p\u003e\n\u003cp\u003eDesigned for research and quality control workflows, QualiUltra™ Probe systems support rapid processing, uniform emulsions, and dependable particle size reduction. Common applications include cell and tissue lysis, dispersion, emulsification, and sample preparation for analytical procedures.\u003c\/p\u003e\n\u003ch2\u003eProbe Ultrasonicator – QualiUltra™ Probe Series Applications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCell and Tissue Lysis (Animal, Plant, Microbial)\u003c\/strong\u003e\u003cbr\u003eUltrasonic cavitation breaks cell membranes and tissue structures, enabling efficient release of proteins, enzymes, DNA\/RNA, and other intracellular components for downstream analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBacteria and Virus Disruption\u003c\/strong\u003e\u003cbr\u003eHigh-frequency shear forces break down microbial structures, supporting extraction, characterization, and inactivation studies in laboratory settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEmulsification\u003c\/strong\u003e\u003cbr\u003eGenerates stable, uniform emulsions for formulation development, method optimization, and process screening where droplet consistency is critical.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNanomaterial and Pigment Dispersion\u003c\/strong\u003e\u003cbr\u003eReduces particle agglomeration and disperses powders into uniform suspensions, helping improve measurement accuracy and formulation consistency.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eParticle Size Reduction and Homogenization\u003c\/strong\u003e\u003cbr\u003eEnables rapid breakdown and even mixing of heterogeneous samples, including viscous liquids and multi-phase systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSoil, Rock, and Environmental Sample Preparation\u003c\/strong\u003e\u003cbr\u003eEnhances sample uniformity for structural and physical analysis, particularly for materials with mixed compositions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBiopharma Dispersion and Extraction\u003c\/strong\u003e\u003cbr\u003eSupports pharmaceutical dispersion and lab-scale extraction processes where controlled ultrasonic energy improves consistency and yield.\u003c\/p\u003e\n\u003ch2\u003eStandards and Compliance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61010-1\u003c\/strong\u003e\u003cbr\u003eDefines safety requirements for electrical equipment used in measurement, control, and laboratory environments, helping ensure safe operation in research and testing settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61326-1\u003c\/strong\u003e\u003cbr\u003eSpecifies electromagnetic compatibility (EMC) requirements, covering both immunity and emissions for laboratory and control equipment to maintain stable performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eISO 20427:2023\u003c\/strong\u003e\u003cbr\u003eOutlines procedures for ultrasonic dispersion using probe-type sonicators, supporting consistent and repeatable workflows for particulate dispersion.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eISO 11201\u003c\/strong\u003e\u003cbr\u003eProvides methods for measuring noise emission sound pressure levels at operator workstations, useful for validating acoustic enclosures and maintaining acceptable lab noise levels.\u003c\/p\u003e\n\u003ch2\u003eProbe Ultrasonicator – QualiUltra™ Probe Series Key Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eHigh-Intensity Cavitation for Fast Processing\u003c\/strong\u003e\u003cbr\u003eGenerates strong shear forces for efficient cell disruption, particle dispersion, and liquid homogenization across a wide range of lab samples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Control for Repeatable Methods\u003c\/strong\u003e\u003cbr\u003eAdjustable power levels and programmable timing support consistent protocols across operators and workflows.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eInterchangeable Probe Tips for Different Volumes and Viscosities\u003c\/strong\u003e\u003cbr\u003eMultiple titanium probe sizes allow accurate energy delivery for micro-volume samples as well as larger batch processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Monitoring for Sample Protection\u003c\/strong\u003e\u003cbr\u003eIntegrated temperature tracking with alerts helps minimize overheating during extended processing cycles.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePulse and Continuous Operation Modes\u003c\/strong\u003e\u003cbr\u003eDuty-cycle control enables pulse settings to limit heat buildup while maintaining effective cavitation performance.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-In Safety Alerts and Protections\u003c\/strong\u003e\u003cbr\u003eTime, temperature, and overload alerts support safe and reliable day-to-day use in lab environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptional Sound-Reduction Enclosure\u003c\/strong\u003e\u003cbr\u003eAvailable configurations include a soundproof enclosure to lower operational noise levels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePreset Program Storage for Routine Workflows\u003c\/strong\u003e\u003cbr\u003eSave and recall processing methods to maintain consistency across quality control and repeat applications.\u003c\/p\u003e\n\u003ch2\u003eProbe Ultrasonicator – QualiUltra™ Probe Series Technical specifications\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003cth\u003eFrequency\u003c\/th\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003cth\u003eStandard probe (Ø)\u003c\/th\u003e\n\u003cth\u003eOptional probe tips (Ø)\u003c\/th\u003e\n\u003cth\u003eSample volume range\u003c\/th\u003e\n\u003cth\u003eDuty cycle\u003c\/th\u003e\n\u003cth\u003eTemperature alarm\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiUltra™ Probe 1200\u003c\/td\u003e\n\u003ctd\u003e1200 W (1–100% adjustable)\u003c\/td\u003e\n\u003ctd\u003e19.5–20.5 kHz\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e20 mm\u003c\/td\u003e\n\u003ctd\u003e15, 25 mm\u003c\/td\u003e\n\u003ctd\u003e50–1000 mL\u003c\/td\u003e\n\u003ctd\u003e0.1–99.9%\u003c\/td\u003e\n\u003ctd\u003e0–99.9°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiUltra™ Probe 1000\u003c\/td\u003e\n\u003ctd\u003e1000 W (20–100 W adjustable)\u003c\/td\u003e\n\u003ctd\u003e20–25 kHz\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003ctd\u003e2, 3, 10, 15 mm\u003c\/td\u003e\n\u003ctd\u003e100 μL–60 mL\u003c\/td\u003e\n\u003ctd\u003e0.1–99.9%\u003c\/td\u003e\n\u003ctd\u003e0–99.9°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiUltra™ Probe 900\u003c\/td\u003e\n\u003ctd\u003e900 W (1–100%)\u003c\/td\u003e\n\u003ctd\u003e20–25 kHz\u003c\/td\u003e\n\u003ctd\u003e7-inch TFT touch screen\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003ctd\u003e2, 3, 10, 12, 15 mm\u003c\/td\u003e\n\u003ctd\u003e100–500 mL\u003c\/td\u003e\n\u003ctd\u003e0–99.9%\u003c\/td\u003e\n\u003ctd\u003e0–99.9°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiUltra™ Probe 650A\u003c\/td\u003e\n\u003ctd\u003e650 W (1–100% adjustable)\u003c\/td\u003e\n\u003ctd\u003e20–25 kHz\u003c\/td\u003e\n\u003ctd\u003e7-inch touch screen\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003ctd\u003e2, 3, 10 mm\u003c\/td\u003e\n\u003ctd\u003e100 μL–50 mL\u003c\/td\u003e\n\u003ctd\u003e0.1–99.9%\u003c\/td\u003e\n\u003ctd\u003e0–99.9°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiUltra™ Probe 650B\u003c\/td\u003e\n\u003ctd\u003e650 W (1–100%)\u003c\/td\u003e\n\u003ctd\u003e20–25 kHz\u003c\/td\u003e\n\u003ctd\u003e7-inch TFT touch screen\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003ctd\u003e2, 3, 10 mm\u003c\/td\u003e\n\u003ctd\u003e100–500 mL\u003c\/td\u003e\n\u003ctd\u003e0–99.9%\u003c\/td\u003e\n\u003ctd\u003e0–99.9°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiUltra™ Probe 250\u003c\/td\u003e\n\u003ctd\u003e250 W (1–100%)\u003c\/td\u003e\n\u003ctd\u003e20–25 kHz\u003c\/td\u003e\n\u003ctd\u003e7-inch TFT touch screen\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003ctd\u003e3 mm\u003c\/td\u003e\n\u003ctd\u003e10–100 mL\u003c\/td\u003e\n\u003ctd\u003e0–99.9%\u003c\/td\u003e\n\u003ctd\u003e0–99.9°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiUltra™ Probe 150\u003c\/td\u003e\n\u003ctd\u003e150 W (1–100%)\u003c\/td\u003e\n\u003ctd\u003e20–25 kHz\u003c\/td\u003e\n\u003ctd\u003e7-inch TFT touch screen\u003c\/td\u003e\n\u003ctd\u003e6 mm\u003c\/td\u003e\n\u003ctd\u003e3 mm\u003c\/td\u003e\n\u003ctd\u003e10–100 mL\u003c\/td\u003e\n\u003ctd\u003e0–99.9%\u003c\/td\u003e\n\u003ctd\u003e0–99.9°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52072148795703,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/probe-ultrasonicator-qualiultratm-probe-series1423922232.webp?v=1777589857"},{"product_id":"integrated-probe-ultrasonicator","title":"Integrated Probe Ultrasonicator","description":"\u003ch2\u003eIntegrated Probe Ultrasonicator – QualiUltra™ Intre Series\u003c\/h2\u003e\n\u003cp\u003eThe QualiUltra™ Intre Series Integrated Probe Ultrasonicator delivers high-intensity probe-based ultrasonication combined with a built-in enclosure, lifting system, and cooling-ready sample management. It uses ultrasonic cavitation to achieve efficient cell disruption, tissue breakdown, liquid homogenization, and particle dispersion with precise and stable energy control.\u003c\/p\u003e\n\u003cp\u003eThis integrated configuration reduces bench space requirements by combining essential components into a single compact system. It is designed for routine laboratory workflows that demand consistent results, reliable parameter control, and enhanced operational safety with continuous temperature monitoring.\u003c\/p\u003e\n\u003cp\u003eThe series includes two model options, supporting applications ranging from micro-volume processing to mid-scale sample handling, making it suitable for a wide range of research and analytical environments.\u003c\/p\u003e\n\u003ch2\u003eIntegrated Probe Ultrasonicator – QualiUltra™ Intre Series Applications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCell and tissue disruption\u003c\/strong\u003e\u003cbr\u003eHigh-intensity cavitation and localized shear forces assist in breaking cell membranes and tissue structures, supporting efficient homogenization and extraction workflows across molecular biology and biochemistry research.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBacterial and viral sample processing\u003c\/strong\u003e\u003cbr\u003eUltrasonic energy helps break down microbial structures for sample preparation tasks, including laboratory protocols that require controlled mechanical lysis and consistent processing conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEmulsification and formulation blending\u003c\/strong\u003e\u003cbr\u003eThe system enables stable emulsions for chemical and pharmaceutical R\u0026amp;D applications where uniform droplet size and mixture stability are critical for reproducible outcomes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNanomaterial preparation and dispersion\u003c\/strong\u003e\u003cbr\u003eProbe-based ultrasonication improves deagglomeration of fine powders and enhances dispersion quality, supporting nanoparticle suspension, material synthesis, and advanced materials research.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtraction, separation support, and defoaming\u003c\/strong\u003e\u003cbr\u003eThe platform is suitable for liquid-phase processing tasks such as extraction assistance, phase preparation steps, and removal of unwanted foam during sample preparation procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReaction enhancement and lab cleaning support\u003c\/strong\u003e\u003cbr\u003eUltrasonic cavitation can help accelerate selected laboratory-scale reaction steps and is also used in cleaning-related applications depending on the specific workflow requirements.\u003c\/p\u003e\n\u003ch3\u003eStandards Compliance\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61010-1\u003c\/strong\u003e\u003cbr\u003eSafety requirements for electrical equipment used in measurement, control, and laboratory environments, ensuring secure operation under defined laboratory conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61326-1\u003c\/strong\u003e\u003cbr\u003eElectromagnetic compatibility (EMC) requirements covering both immunity and emission levels for laboratory and measurement equipment, supporting stable performance in controlled environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eISO 20427:2023\u003c\/strong\u003e\u003cbr\u003eProvides a standardized methodology for ultrasonic dispersion using probe-type sonication, supporting consistent and reproducible laboratory procedures across applications.\u003c\/p\u003e\n\u003ch2\u003eIntegrated Probe Ultrasonicator – QualiUltra™ Intre Series Key Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpace-efficient integrated design\u003c\/strong\u003e\u003cbr\u003eA compact benchtop structure integrates the full sonication setup, helping optimize laboratory space and streamline workflow organization.\u003cbr\u003e\u003cstrong\u003eMotorized probe lifting with remote operation\u003c\/strong\u003e\u003cbr\u003eElectric lifting mechanism enables smooth probe positioning with remote-control functionality, supporting consistent setup and repeatable processing height.\u003cbr\u003e\u003cstrong\u003eMultiple probe options for varied applications\u003c\/strong\u003e\u003cbr\u003eA range of probe sizes allows adaptation to different sample volumes and processing intensities, from gentle emulsification to high-energy disruption tasks.\u003cbr\u003e\u003cstrong\u003eProgrammable control with fine power adjustment\u003c\/strong\u003e\u003cbr\u003ePrecise power settings support controlled energy delivery for method optimization, development work, and routine laboratory use.\u003cbr\u003e\u003cstrong\u003eTemperature control with safety alerts\u003c\/strong\u003e\u003cbr\u003eReal-time temperature tracking combined with built-in alarms helps maintain safer operating conditions during extended processing cycles.\u003cbr\u003e\u003cstrong\u003ePulse and continuous processing modes\u003c\/strong\u003e\u003cbr\u003eFlexible operation modes allow pulse sonication for heat management or continuous output for higher throughput applications, with accurate timing control.\u003cbr\u003e\u003cstrong\u003eNoise-reducing enclosure with easy maintenance\u003c\/strong\u003e\u003cbr\u003eAn enclosed structure minimizes operational noise, while the smooth internal design supports quick and efficient cleaning between runs.\u003cbr\u003e\u003cstrong\u003eDurable titanium alloy probe construction\u003c\/strong\u003e\u003cbr\u003eHigh-strength titanium alloy probe components are designed to withstand repeated ultrasonic stress and long-term laboratory usage.\u003c\/p\u003e\n\u003ch2\u003eIntegrated Probe Ultrasonicator – QualiUltra™ Intre Series Technical specification\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ Intre-650A\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ Intre-650B\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasonic frequency\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e20–25 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower output\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e650 W (1–100%)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e7-inch capacitive touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard probe\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional probe sizes\u003c\/td\u003e\n\u003ctd\u003e2 mm, 3 mm, 8 mm, 10 mm, 13 mm\u003c\/td\u003e\n\u003ctd\u003e2 mm, 3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample volume\u003c\/td\u003e\n\u003ctd\u003e100 μL–250 mL\u003c\/td\u003e\n\u003ctd\u003e100 μL–50 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty cycle\u003c\/td\u003e\n\u003ctd\u003e0.1–99.9%\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm temperature \/ range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0–99.9°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTransducer lifting mode\u003c\/td\u003e\n\u003ctd\u003eElectric (optional remote control)\u003c\/td\u003e\n\u003ctd\u003eElectric, remote-control lifting as standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e312 × 334 × 510 mm\u003c\/td\u003e\n\u003ctd\u003e312 × 334 × 620 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefrigeration temperature\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e-4°C to room temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdapter\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eStandard: 2 mL, 50 mL refrigeration adapter; Optional: 0.2 mL, 0.5 mL, 5 mL, 10 mL, 15 mL refrigeration adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterior lighting\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSterilization function\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eListed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52072168718647,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/integrated-probe-ultrasonicator1338003992.webp?v=1777590110"},{"product_id":"smart-probe-ultrasonicator","title":"Smart Probe Ultrasonicator","description":"\u003ch2\u003eSmart Probe Ultrasonicator – QualiUltra™ Smart Series\u003c\/h2\u003e\n\u003cp\u003eThe QualiUltra™ Smart Series Probe Ultrasonicator delivers high-intensity ultrasonic cavitation for efficient cell lysis, tissue disruption, and uniform liquid homogenization with precise energy regulation. Advanced smart control capabilities ensure steady operation through automatic frequency tracking, impedance matching, and integrated safeguards against overload and excessive temperature.\u003c\/p\u003e\n\u003cp\u003eThis series is developed for laboratories that require highly repeatable protocols, secure parameter storage, and streamlined operating procedures. A noise-reducing enclosure combined with automated probe lifting and system enhancements supports safer handling during processing while maintaining a clean and organized workspace.\u003c\/p\u003e\n\u003cp\u003eThe QualiUltra™ Smart Series provides a scalable Probe Ultrasonicator platform suitable for both small and large sample volumes. Output power is adjustable across models, with a standard operating range of 20–25 kHz to maintain consistent cavitation performance. Built-in time and temperature regulation helps preserve method accuracy during routine workflows.\u003c\/p\u003e\n\u003cp\u003eA smart control architecture ensures stable and reliable operation, featuring automatic frequency tracking, system diagnostics, alert functions, and protected program storage. Connectivity options enable integration with a main unit computer for centralized control and remote printing support within lab networks.\u003c\/p\u003e\n\u003ch2\u003eSmart Probe Ultrasonicator – QualiUltra™ Smart Series Applications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCell lysis and biomolecule extraction\u003c\/strong\u003e\u003cbr\u003eUltrasonic cavitation disrupts cell membranes to support extraction of DNA, RNA, and proteins. It is widely used in sample preparation involving bacteria, viruses, and spores where strong mechanical disruption is required.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDNA\/RNA fragmentation and size control\u003c\/strong\u003e\u003cbr\u003ePrecisely managed sonication reduces nucleic acid fragment length for workflows requiring defined size ranges. Adjustable pulse modes and processing duration allow fine control of energy input while limiting excessive heat generation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eChromatin immunoprecipitation (ChIP) preparation\u003c\/strong\u003e\u003cbr\u003eProbe-based ultrasonication supports chromatin fragmentation steps used in ChIP workflows. Consistent energy delivery improves reproducibility, while temperature monitoring and safety functions help maintain stable processing conditions during extended runs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNanomaterial dispersion and deagglomeration\u003c\/strong\u003e\u003cbr\u003eThe system facilitates dispersion and breakup of clustered nanomaterials such as carbon nanotubes and graphene, producing more uniform suspensions. This improves reliability in materials research, chemical studies, and formulation development.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEmulsification and homogenization processes\u003c\/strong\u003e\u003cbr\u003eHigh-intensity cavitation supports emulsification, homogenization, and particle size reduction in chemical and formulation applications. Stable power output and consistent frequency behavior enhance method repeatability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSoil, rock, and particulate sample preparation\u003c\/strong\u003e\u003cbr\u003eProbe ultrasonication assists in homogenizing soil, rock, and particulate samples for analytical workflows where uniform dispersion is required. It is also used across geological, marine, environmental, and biomedical sample preparation applications.\u003c\/p\u003e\n\u003ch2\u003eCompliance Standards\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eIEC 61010-1 — Safety requirements for electrical equipment used in measurement, control, and laboratory environments, ensuring protection against electrical, mechanical, and thermal hazards.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIEC 61326-1 — Electromagnetic compatibility (EMC) standard covering emission limits and immunity performance for laboratory and analytical instruments, supporting stable operation in controlled environments.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eISO 20427 — Standardized methodology for ultrasonic dispersion procedures using probe-type sonication systems, providing guidance for consistent and reproducible processing results.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eSmart Probe Ultrasonicator – QualiUltra™ Smart Series Key Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSmart control architecture for stable output\u003c\/strong\u003e\u003cbr\u003eA microcontroller-based system using DSP + ARM processing is described to support steady operation, precise control, and reliable data handling during ultrasonic processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic frequency tracking and impedance matching\u003c\/strong\u003e\u003cbr\u003eReal-time frequency adjustment and impedance adaptation help maintain consistent cavitation performance even when sample conditions change.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePulse and continuous operation for thermal control\u003c\/strong\u003e\u003cbr\u003eMultiple operating modes, including pulse and continuous sonication, allow users to manage energy input and reduce temperature rise in sensitive samples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLarge touch display with real-time parameter view\u003c\/strong\u003e\u003cbr\u003eA 7-inch TFT touchscreen provides clear access to key settings such as temperature, power\/amplitude, and pulse configuration, enabling direct on-screen control.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSecure method storage for reproducible workflows\u003c\/strong\u003e\u003cbr\u003eUp to 20 method profiles can be saved, with password-based access control to support standardized and secure laboratory operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in diagnostics and protection systems\u003c\/strong\u003e\u003cbr\u003eSelf-check functions and safety alerts help monitor system status, with protections for overload and excessive temperature clearly indicated during operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eConnectivity for laboratory integration\u003c\/strong\u003e\u003cbr\u003eRJ-45 and wireless communication options support main unit system connectivity, enabling centralized control and remote printing within lab networks.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSound-reducing enclosure with integrated handling features\u003c\/strong\u003e\u003cbr\u003eAn enclosed chamber design includes illumination, sterilization function, automatic probe lifting, and door-lock safety features to support controlled and organized operation.\u003c\/p\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003eProbe-based ultrasonic systems produce alternating pressure waves in liquid media, leading to the formation of cavitation bubbles. The collapse of these bubbles generates localized shear forces and micro-jets that facilitate cell disruption, particle dispersion, and enhanced mixing efficiency. Consistent performance is achieved through stable energy delivery, supported by automatic frequency tracking and impedance matching to maintain uniform cavitation behavior.\u003c\/p\u003e\n\u003cp\u003eA standard workflow begins with selecting an appropriate probe tip size based on sample volume and viscosity. Next, define processing parameters such as target power level, pulse or continuous operation mode, and total processing duration. Temperature should be monitored throughout the cycle to avoid thermal impact on sensitive materials. For temperature-sensitive applications, a cooling system or ice bath can be used to maintain tighter thermal control. After completion, the probe should be cleaned thoroughly, and the optimized settings can be saved as a method to ensure consistent repetition in future runs.\u003c\/p\u003e\n\u003ch2\u003eSmart Probe Ultrasonicator – QualiUltra™ Smart Series Technical Specification\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ Smart 650\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ Smart 950\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ Smart 1200\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower range (adjustable)\u003c\/td\u003e\n\u003ctd\u003e5–650 W\u003c\/td\u003e\n\u003ctd\u003e5–950 W\u003c\/td\u003e\n\u003ctd\u003e5–1200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e20–25 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProcessing volume\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.2–500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTime range\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0–999 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature control\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0–100°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlerts\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eTemperature, time, failure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoundproof box\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eInternal electric lifting device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoundproof box size\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e350 × 345 × 545 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard probe (horn)\u003c\/td\u003e\n\u003ctd\u003eØ6 mm\u003c\/td\u003e\n\u003ctd\u003eØ6 mm\u003c\/td\u003e\n\u003ctd\u003eØ20 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional probe tips\u003c\/td\u003e\n\u003ctd\u003eØ2, Ø3, Ø10, Ø12 mm\u003c\/td\u003e\n\u003ctd\u003eØ2, Ø3, Ø10, Ø12, Ø15 mm\u003c\/td\u003e\n\u003ctd\u003eØ15, Ø25 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptional cooling cup\u003c\/td\u003e\n\u003ctd\u003e30 mL, 100 mL, 400 mL\u003c\/td\u003e\n\u003ctd\u003e30 mL, 100 mL, 400 mL\u003c\/td\u003e\n\u003ctd\u003e100 mL, 400 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard configuration\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eMain Unit + transducer + probe + software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52072180547895,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/smart-probe-ultrasonicator1852959175.webp?v=1777590404"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/collections\/probe-ultrasonicator1509556151.webp?v=1777589655","url":"https:\/\/qualitest.us\/collections\/probe-ultrasonicator.oembed","provider":"Qualitest USA LC","version":"1.0","type":"link"}