{"title":"Contactless Ultrasonicator","description":"\u003ch2\u003eContactless Ultrasonicator – Sealed Tube Ultrasonic Processing\u003c\/h2\u003e\n\u003cp\u003eA Contactless Ultrasonicator processes samples within sealed tubes without direct probe contact. This configuration supports contamination-controlled workflows, minimizes carryover risk, and delivers stable, repeatable results when multiple tubes require identical ultrasonic conditions.\u003c\/p\u003e\n\u003cp\u003eThis sealed-tube ultrasonic approach is ideal for sensitive laboratory applications where sample integrity and cross-contamination prevention are critical. It ensures consistent energy transfer while maintaining a closed environment throughout processing.\u003c\/p\u003e\n\u003ch2\u003eQualiUltra™ Contactless Ultrasonication Platforms\u003c\/h2\u003e\n\u003cp\u003eQualiUltra™ provides multiple contact-free ultrasonic processing configurations designed for flexible laboratory requirements:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMulti-tube rack systems for parallel batch processing of sealed samples under uniform conditions\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eIndirect cup sonication systems for non-contact energy transfer through an external medium\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eDry non-contact cooling setups for temperature-sensitive trace-level workflows\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eCompact sealed microtube processing units for efficient small-volume pretreatment in closed vessels\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThese configurations support a wide range of sealed-sample ultrasonic workflows, enabling consistent processing performance across different tube formats and laboratory applications.\u003c\/p\u003e\n\u003ch2\u003eApplications of Contactless Ultrasonicator\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMolecular Biology and Genomics Sample Preparation\u003c\/strong\u003e\u003cbr\u003eSealed-tube ultrasonic processing supports workflows such as ChIP sample preparation, DNA fragmentation, nucleic acid extraction, and sequencing sample homogenization. Multi-position tube racks help maintain consistent processing conditions across multiple samples in a single run, improving workflow uniformity and reproducibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMicrobiology Disruption and Intracellular Extraction\u003c\/strong\u003e\u003cbr\u003eContactless sonication enables efficient disruption of bacterial and cellular structures while supporting downstream extraction of intracellular proteins and nucleic acids. This closed-tube approach helps maintain a cleaner workflow by limiting exposure and reducing handling-related variability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBiopharmaceutical and Formulation Processes\u003c\/strong\u003e\u003cbr\u003eSealed ultrasonic processing is suitable for handling sensitive reagents and supporting emulsification-related reactions. Systems such as the FC Series are used for small-volume liposome preparation and controlled emulsification steps where precise cycle management is important for consistent outcomes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHeat-Sensitive Samples and Enhanced Safety Handling\u003c\/strong\u003e\u003cbr\u003eIntegrated temperature control with real-time monitoring helps protect temperature-sensitive biomolecules such as proteins and nucleic acids during processing. The non-contact design also helps limit aerosol or mist formation during high-energy sonication, supporting safer laboratory operation and improved containment during disruptive workflows.\u003c\/p\u003e\n\u003ch2\u003eComparison Table: Which Contactless Ultrasonicator Fits the Workflow?\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSeries\u003c\/th\u003e\n\u003cth\u003eCore approach\u003c\/th\u003e\n\u003cth\u003eBest for\u003c\/th\u003e\n\u003cth\u003eThroughput style\u003c\/th\u003e\n\u003cth\u003eTemperature support\u003c\/th\u003e\n\u003cth\u003eKey differentiator\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiUltra™ NC Series\u003c\/td\u003e\n\u003ctd\u003eMulti-hole bracket, sealed-tube indirect processing\u003c\/td\u003e\n\u003ctd\u003eUltra-trace, sterile workflows; genomics and microbiology\u003c\/td\u003e\n\u003ctd\u003eMultiple tubes per run\u003c\/td\u003e\n\u003ctd\u003eLow-temp compatibility; temperature display\u003c\/td\u003e\n\u003ctd\u003eBatch consistency across many tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiUltra™ CL Series\u003c\/td\u003e\n\u003ctd\u003eCup-type coupling chamber; sealed tubes in holders\u003c\/td\u003e\n\u003ctd\u003eBroad container support; sterile handling\u003c\/td\u003e\n\u003ctd\u003eHolder-base batches\u003c\/td\u003e\n\u003ctd\u003eChiller pairing for heat control\u003c\/td\u003e\n\u003ctd\u003eReduces probe-wear debris risk\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiUltra™ DCL Series\u003c\/td\u003e\n\u003ctd\u003eDry non-contact, single sealed tube; bottom module\u003c\/td\u003e\n\u003ctd\u003eTrace samples; nucleic-acid prep; fast pretreatment\u003c\/td\u003e\n\u003ctd\u003eSingle-tube workflows\u003c\/td\u003e\n\u003ctd\u003eSemiconductor cooling 8–12°C\u003c\/td\u003e\n\u003ctd\u003eDirect path to downstream detection steps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiUltra™ FC Series\u003c\/td\u003e\n\u003ctd\u003eContact-free processing of sealed microtubes\u003c\/td\u003e\n\u003ctd\u003eRapid detection and on-site inspection\u003c\/td\u003e\n\u003ctd\u003eCycle-based protocols\u003c\/td\u003e\n\u003ctd\u003eDesigned to reduce splashes\/aerosols vs open handling\u003c\/td\u003e\n\u003ctd\u003eSimple setup for fast, repeatable pretreatment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch2\u003eWhy Choose QualiUltra™ for Contactless Ultrasonicator Work?\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eReduced contamination risk with sealed-tube workflows that support cleaner sample handling and help limit cross-sample interference.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eFlexible throughput options covering both batch processing with multi-tube setups and focused single-tube operation for smaller workloads.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eThermal control designed for sensitive applications, including real-time temperature monitoring, low-temperature compatibility, and optional integrated cooling depending on the system configuration.\u003cbr\u003e\n\u003c\/li\u003e\n\u003cli\u003eHigh reproducibility through precise control settings, including adjustable power output, duty cycle control, and time programming, with parameter storage available in supported models for consistent method replication.\u003c\/li\u003e\n\u003c\/ul\u003e","products":[{"product_id":"non-contact-ultrasonicator","title":"Non-Contact Ultrasonicator","description":"\u003ch2\u003eNon-Contact Ultrasonicator – QualiUltra™ NC Series\u003c\/h2\u003e\n\u003cp\u003eThe QualiUltra™ NC Series Non-Contact Ultrasonicator provides advanced sample disruption inside sealed tubes without any direct probe contact. This contact-free ultrasonic processing method helps preserve sample integrity, reduces contamination risk, and maintains clean, consistent laboratory workflows. It is well-suited for sensitive materials where purity and trace-level control are essential.\u003c\/p\u003e\n\u003cp\u003eDesigned for higher throughput, the system supports multi-position tube racks that allow simultaneous processing of several samples, improving efficiency over single-tube setups. Adjustable settings for power output, processing time, and duty cycle give precise control over ultrasonic energy for different protocols.\u003c\/p\u003e\n\u003cp\u003eThe QualiUltra™ NC Series is optimized for sterile, ultra-trace, and temperature-sensitive applications, including nucleic acid preparation and protein research workflows. Low-temperature compatibility enables controlled cooling conditions during operation, helping manage heat buildup. Built-in temperature display supports real-time monitoring for stable and repeatable performance.\u003c\/p\u003e\n\u003ch2\u003eNon-Contact Ultrasonicator – QualiUltra™ NC Series Applications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eMolecular biology sample preparation\u003c\/strong\u003e\u003cbr\u003eSealed-tube ultrasonic processing supports ChIP sample preparation, DNA fragmentation, and nucleic acid extraction while minimizing cross-contamination between runs. This approach is well-suited for workflows where even trace contamination can impact downstream accuracy and reproducibility.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGenomics and high-throughput sequencing workflows\u003c\/strong\u003e\u003cbr\u003eMulti-position tube racks enable simultaneous processing of multiple sequencing samples, helping standardize preparation across batches. This improves consistency and supports efficient handling in high-throughput laboratory environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMicrobiology and cell disruption\u003c\/strong\u003e\u003cbr\u003eContactless sonication assists in bacterial and cell disruption as well as membrane protein extraction workflows. Adjustable duty cycle settings allow fine control over energy delivery, helping manage heat generation during extended processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBiopharmaceutical and formulation studies\u003c\/strong\u003e\u003cbr\u003eThe system supports ultrasonic treatment of sensitive reagents and emulsification-based processes. Working with sealed containers helps streamline handling steps while maintaining sample integrity during processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature-sensitive research applications\u003c\/strong\u003e\u003cbr\u003eLow-temperature compatibility supports workflows involving proteins, nucleic acids, and other heat-sensitive materials. Integrated temperature display allows real-time monitoring to maintain controlled processing conditions and improve result reliability.\u003c\/p\u003e\n\u003ch2\u003eStandards Compliance – QualiUltra™ NC Series\u003c\/h2\u003e\n\u003cp\u003eThe QualiUltra™ NC Series Non-Contact Ultrasonicator is aligned with internationally recognized laboratory equipment standards to support safe, stable, and controlled operation in research environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61010-1\u003c\/strong\u003e\u003cbr\u003eDefines safety requirements for electrical equipment used in measurement, control, and laboratory applications. This standard ensures safe operation under specified laboratory conditions, including protection against electrical hazards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61326-1\u003c\/strong\u003e\u003cbr\u003eCovers electromagnetic compatibility (EMC) requirements for laboratory and analytical instruments. It addresses both emission control and immunity performance, helping ensure reliable operation in environments with other electronic equipment.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eISO 20427:2023\u003c\/strong\u003e\u003cbr\u003eProvides standardized procedures for ultrasonic dispersion using laboratory ultrasonic devices, including both bath and probe systems. This standard supports consistency in ultrasonic processing methods used in sample preparation and dispersion workflows.\u003c\/p\u003e\n\u003ch2\u003eNon-Contact Ultrasonicator – QualiUltra™ NC Series Key Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eContactless, contamination-controlled processing\u003c\/strong\u003e\u003cbr\u003eSealed-tube operation ensures the sample is never exposed to a probe, helping maintain sterile conditions and lowering the risk of cross-contamination between samples.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBatch processing with multi-position tube racks\u003c\/strong\u003e\u003cbr\u003eMulti-hole brackets allow simultaneous processing of multiple tubes, increasing sample throughput compared to single-sample sonication setups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLow-temperature compatibility for sensitive samples\u003c\/strong\u003e\u003cbr\u003eSupport for controlled low-temperature operation helps protect heat-sensitive materials during ultrasonic disruption and homogenization.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBroad control range for protocol optimization\u003c\/strong\u003e\u003cbr\u003eAdjustable power settings, extended timing options, and precise duty cycle control enable workflows ranging from mild homogenization to more intensive disruption procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature monitoring display\u003c\/strong\u003e\u003cbr\u003eIntegrated temperature display provides real-time feedback during operation, supporting better control of processing conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eScalable platform design\u003c\/strong\u003e\u003cbr\u003eTwo model variants offer different tank capacities and bracket configurations, allowing users to select appropriate configurations based on sample volume and batch processing requirements.\u003c\/p\u003e\n\u003ch2\u003eTheory and Method – QualiUltra™ NC Series Non-Contact Ultrasonicator\u003c\/h2\u003e\n\u003cp\u003eThe QualiUltra™ NC Series Ultrasonicator operates through indirect ultrasonic energy transmission via a coupling medium in which sealed tubes are positioned within a multi-hole bracket. Ultrasonic waves generate cavitation in the surrounding medium, producing localized shear forces that disrupt cells and shear biomolecules inside the closed containers without any direct probe contact. This contactless mechanism helps maintain sample integrity while supporting contamination-controlled processing conditions.\u003c\/p\u003e\n\u003cp\u003eProcess intensity is managed through adjustable power settings and duty cycle control, allowing fine-tuning of energy delivery for different applications. Extended timing capability supports longer protocols where gradual or sustained ultrasonic exposure is required. Low-temperature compatibility can be integrated to maintain a controlled cool environment, helping protect heat-sensitive samples during processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eStandard operating workflow:\u003c\/strong\u003e\u003cbr\u003eBegin by selecting the appropriate tube format and bracket configuration based on sample volume. Place sealed tubes securely into the holder, then set parameters including power level, duty cycle, and total processing time. During operation, monitor the built-in temperature display to track thermal conditions. For proteins, nucleic acids, and other temperature-sensitive materials, cooling support is recommended to manage heat buildup during extended runs. Once processing is complete, remove the tubes and proceed with downstream extraction, purification, or analytical workflows.\u003c\/p\u003e\n\u003ch2\u003eNon-Contact Ultrasonicator – QualiUltra™ NC Series Technical Specification\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ NC 1800\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ NC 2200\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasonic frequency\u003c\/td\u003e\n\u003ctd\u003e40 kHz\u003c\/td\u003e\n\u003ctd\u003e40 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower rating\u003c\/td\u003e\n\u003ctd\u003e1800 W (1–99% adjustable)\u003c\/td\u003e\n\u003ctd\u003e2200 W (1–99% adjustable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTiming range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1–999 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty cycle\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1–99.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank volume\u003c\/td\u003e\n\u003ctd\u003e1.5 L\u003c\/td\u003e\n\u003ctd\u003e3 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTube holder \/ crushing brackets\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1–2 mL × 16 holes;\u003c\/p\u003e\n\u003cp\u003e5 mL × 8 holes;\u003c\/p\u003e\n\u003cp\u003e10–15 mL × 8 holes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1–2 mL × 32 holes;\u003c\/p\u003e\n\u003cp\u003e5 mL × 20 holes;\u003c\/p\u003e\n\u003cp\u003e10–15 mL × 17 holes\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature display\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e220\/110 V ±0.5, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCore features summary\u003c\/td\u003e\n\u003ctd\u003eAirtight container processing, sterile workflows, low-temperature adaptable\u003c\/td\u003e\n\u003ctd\u003eSame as QualiUltra™ CL 1800 with larger tank and higher throughput brackets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52072245362999,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/non-contact-ultrasonicator1488010427.webp?v=1777592488"},{"product_id":"contactless-ultrasonicator-qualiultra-cl-series","title":"Contactless Ultrasonicator – QualiUltra™ CL Series","description":"\u003ch2\u003eContactless Ultrasonicator – QualiUltra™ CL Series\u003c\/h2\u003e\n\u003cp\u003eThe QualiUltra™ CL Series Contactless Ultrasonicator is engineered for non-contact, cup-style sonication where samples are processed inside sealed tubes. This approach eliminates direct probe interaction, helping lower the risk of cross-contamination and supporting cleaner laboratory workflows.\u003c\/p\u003e\n\u003cp\u003eDesigned for multi-tube processing in a single cycle, the system enhances sample throughput and supports efficient routine laboratory operations. Built-in temperature display functionality allows real-time monitoring during extended runs, helping maintain controlled processing conditions.\u003c\/p\u003e\n\u003cp\u003eThe QualiUltra™ CL Series is well-suited for sterile environments and ultra-trace analysis workflows that demand consistent, repeatable results with minimal manual handling. It supports low to ultra-low volume processing while maintaining high standards of sample integrity and operational consistency.\u003c\/p\u003e\n\u003ch2\u003eApplications of QualiUltra™ CL Series Contactless Ultrasonicator\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eChIP assay sample preparation\u003c\/strong\u003e\u003cbr\u003eContactless sonication supports chromatin fragmentation workflows while keeping samples contained in sealed tubes. This reduces the risk of carryover between runs, especially during multi-sample processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBacterial and cell disruption with membrane protein extraction\u003c\/strong\u003e\u003cbr\u003eUltrasonic energy is transmitted through the cup to achieve efficient cell disruption without direct probe contact. This setup supports cleaner handling and is well-suited for sensitive protein extraction and routine cell lysis workflows.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSample preparation for high-throughput sequencing (NGS)\u003c\/strong\u003e\u003cbr\u003eMulti-tube holders enable simultaneous processing of multiple samples in a single run. This helps improve workflow consistency across batches and enhances overall laboratory productivity.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHomogenization and emulsification processes\u003c\/strong\u003e\u003cbr\u003eContactless sonication supports controlled mixing and emulsification reactions where stable energy delivery is important. Adjustable power levels and duty cycle settings allow fine-tuning based on specific protocol requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUltrasonic processing of valuable reagents\u003c\/strong\u003e\u003cbr\u003eSealed-tube operation helps safeguard limited or high-value reagents by minimizing exposure and handling steps. The non-contact design also eliminates the possibility of contamination from probe wear particles entering the sample.\u003c\/p\u003e\n\u003ch3\u003eStandards Compliance\u003c\/h3\u003e\n\u003cp\u003eThe QualiUltra™ CL Series Contactless Ultrasonicator is designed in alignment with internationally recognized laboratory equipment standards to support safe, reliable, and consistent operation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61010-1\u003c\/strong\u003e\u003cbr\u003eEnsures compliance with safety requirements for electrical equipment used in measurement, control, and laboratory environments, supporting operator protection and instrument reliability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61326-1\u003c\/strong\u003e\u003cbr\u003eCovers electromagnetic compatibility (EMC) requirements, including immunity and emission limits for laboratory and analytical equipment, helping maintain stable performance in controlled lab settings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eISO 20427:2023\u003c\/strong\u003e\u003cbr\u003eDefines standardized approaches for sample preparation methods involving ultrasonic dispersion, including both probe-based and bath-type systems, supporting consistent and reproducible laboratory workflows.\u003c\/p\u003e\n\u003ch2\u003eContactless Ultrasonicator – QualiUltra™ CL Series Key Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eNon-contact sonication for cleaner workflows\u003c\/strong\u003e\u003cbr\u003eSealed-tube processing eliminates direct probe contact with samples, helping reduce cross-contamination risk and supporting cleaner laboratory operations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnclosed processing for improved biological safety\u003c\/strong\u003e\u003cbr\u003eThe enclosed system helps contain aerosols during disruptive procedures, contributing to safer handling in sensitive biological applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh repeatability through adjustable parameters\u003c\/strong\u003e\u003cbr\u003eConfigurable power output, timing, and duty cycle settings enable consistent processing results across multiple batches and users.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBroad container compatibility\u003c\/strong\u003e\u003cbr\u003eSupports a range of commonly used tube formats, with optional custom holders available for specific volume requirements and workflow needs.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature-controlled processing with chiller integration\u003c\/strong\u003e\u003cbr\u003eCan be paired with external cooling systems to help manage heat buildup during extended sonication protocols, supporting sample stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRotating tube platform for uniform exposure\u003c\/strong\u003e\u003cbr\u003eAutomated rotation of tube holders promotes more even energy distribution across samples, improving consistency within a single run.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLow sample loss for ultra-small volume applications\u003c\/strong\u003e\u003cbr\u003eDesigned to support ultra-low volume workflows where sample conservation is critical, helping maintain integrity throughout processing.\u003c\/p\u003e\n\u003ch2\u003eTheory and Method – Contactless Ultrasonicator (QualiUltra™ CL Series)\u003c\/h2\u003e\n\u003cp\u003eThe QualiUltra™ CL Series Contactless Ultrasonicator operates using indirect ultrasonic energy transmitted through a coupling medium within a cup-style chamber. Ultrasonic cavitation and micro-streaming generated in the surrounding medium transfer controlled energy into sealed tubes, enabling efficient cell disruption and biomolecule fragmentation without direct probe interaction. This non-contact approach helps minimize cross-contamination and supports cleaner, more controlled sample handling in sensitive workflows.\u003c\/p\u003e\n\u003cp\u003eA standard workflow begins by selecting a tube holder compatible with the required sample volume and container size. Sealed tubes are then positioned in the holder before configuring key parameters such as power level, duty cycle, and total processing time. During operation, temperature readings can be monitored in real time to maintain process control.\u003c\/p\u003e\n\u003cp\u003eFor applications involving proteins or nucleic acids where thermal stability is important, integration with a chiller or external cooling system helps maintain stable conditions throughout the run. Once processing is complete, tubes are removed directly for downstream extraction, purification, or analytical procedures.\u003c\/p\u003e\n\u003ch2\u003eContactless Ultrasonicator – QualiUltra™ CL Series Technical Specification\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ CL 20 (Cup-Type)\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ CL 40A\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ CL 40B\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency\u003c\/td\u003e\n\u003ctd\u003e20 kHz (±0.5 kHz)\u003c\/td\u003e\n\u003ctd\u003e40 kHz\u003c\/td\u003e\n\u003ctd\u003e40 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e1800 W\u003c\/td\u003e\n\u003ctd\u003e2200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdjustable power\u003c\/td\u003e\n\u003ctd\u003e1–100%\u003c\/td\u003e\n\u003ctd\u003e1–99%\u003c\/td\u003e\n\u003ctd\u003e1–99%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTiming\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e1–999 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDuty cycle\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003e0.1–99.9%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTank volume\u003c\/td\u003e\n\u003ctd\u003e900 mL\u003c\/td\u003e\n\u003ctd\u003e1.5 L\u003c\/td\u003e\n\u003ctd\u003e3 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature display\u003c\/td\u003e\n\u003ctd colspan=\"3\"\u003eAvailable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTube holder capacity\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e0.5 mL × 12 wells;\u003c\/p\u003e\n\u003cp\u003e2 mL × 12 wells;\u003c\/p\u003e\n\u003cp\u003e0.2 mL × 12 wells;\u003c\/p\u003e\n\u003cp\u003ecustomizable 5–50 mL\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1–2 mL × 16 wells;\u003c\/p\u003e\n\u003cp\u003e5 mL × 8 wells;\u003c\/p\u003e\n\u003cp\u003e10–15 mL × 8 wells\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cp\u003e1–2 mL × 32 wells;\u003c\/p\u003e\n\u003cp\u003e5 mL × 20 wells;\u003c\/p\u003e\n\u003cp\u003e10–15 mL × 17 wells\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e220 V ±0.5, 50 Hz\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e220\/110 V ±0.5, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatching chiller\u003c\/td\u003e\n\u003ctd\u003eStandard equipment support\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52072251752759,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/contactless-ultrasonicator-qualiultratm-cl-series1026130552.webp?v=1777592746"},{"product_id":"dry-contactless-ultrasonicator","title":"Dry Contactless Ultrasonicator","description":"\u003ch2\u003eDry Contactless Ultrasonicator – QualiUltra™ DCL Series\u003c\/h2\u003e\n\u003cp\u003eThe QualiUltra™ DCL Series Dry Contactless Ultrasonicator is a non-contact, sealed-tube processing system designed for handling trace and low-volume samples. Its probe-free architecture eliminates direct interaction between the sonication source and the sample, helping lower contamination risks while streamlining workflow setup compared to conventional probe-based systems.\u003c\/p\u003e\n\u003cp\u003eThis system uses a bottom-mounted ultrasonic module that delivers energy through sealed sample tubes, enabling efficient processing without opening or transferring contents. Integrated semiconductor-based cooling maintains a controlled low-temperature environment throughout operation, helping preserve the stability of temperature-sensitive biomolecules such as proteins and nucleic acids.\u003c\/p\u003e\n\u003cp\u003eThe QualiUltra™ DCL Series is optimized for rapid pretreatment in high-throughput molecular workflows, including nucleic acid preparation steps used in detection and analysis pipelines. Once processing is complete, samples can proceed directly into amplification, hybridization, or other downstream procedures with minimal handling, supporting smoother laboratory workflows.\u003c\/p\u003e\n\u003cp\u003eDesigned for compact bench-top use, this Ultrasonicator supports small-volume applications such as membrane disruption and cell lysis in sealed 2.0 mL tubes. It operates within a working volume range of 500–1000 µL, making it suitable for a wide variety of trace-sample protocols that require speed and consistency.\u003c\/p\u003e\n\u003cp\u003eTemperature control is managed through an integrated semiconductor refrigeration system, maintaining a stable operating range of approximately 8–12°C during processing. This helps reduce heat-related degradation of sensitive biological targets. The system also supports stored parameter settings, allowing users to repeat optimized conditions for consistent experimental outcomes across multiple runs.\u003c\/p\u003e\n\u003ch2\u003eDry Contactless Ultrasonicator – QualiUltra™ DCL Series Applications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTrace-sample pretreatment for rapid detection workflows\u003c\/strong\u003e\u003cbr\u003eSupports fast processing of low-volume and trace samples where quick turnaround is essential. Designed for efficient preparation in time-sensitive detection and analytical pipelines.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSealed-tube cell and bacteria disruption\u003c\/strong\u003e\u003cbr\u003eEnables effective cell lysis and bacterial disruption inside sealed tubes without direct probe contact. This approach supports extraction of proteins, nucleic acids, and intracellular components while minimizing sample handling steps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNucleic acid amplification preparation\u003c\/strong\u003e\u003cbr\u003eProcessed samples are suitable for downstream amplification workflows, helping streamline the transition from sample preparation to analysis by reducing intermediate transfer steps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProbe hybridization and detection preparation\u003c\/strong\u003e\u003cbr\u003eSupports consistent sample conditioning for probe-based hybridization and molecular detection workflows. This helps maintain reliability in downstream diagnostic and analytical procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSmall-volume biomolecule extraction workflows\u003c\/strong\u003e\u003cbr\u003eWell-suited for extracting target biomolecules such as proteins and nucleic acids from disrupted samples in low-volume formats. Integrated temperature control supports stability during processing, especially for heat-sensitive targets.\u003c\/p\u003e\n\u003ch2\u003eStandards Compliance – QualiUltra™ DCL Series\u003c\/h2\u003e\n\u003cp\u003eThe QualiUltra™ DCL Series Dry Contactless Ultrasonicator is developed with alignment to internationally recognized laboratory and medical device standards, supporting safe operation, performance reliability, and structured quality management in regulated environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61010-1 – Laboratory Equipment Safety Requirements\u003c\/strong\u003e\u003cbr\u003eEnsures general safety principles for electrical equipment used in laboratory, measurement, and control applications, focusing on operator protection and safe system design.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61326-1 – EMC Compliance (Immunity \u0026amp; Emissions)\u003c\/strong\u003e\u003cbr\u003eDefines electromagnetic compatibility requirements for laboratory and measurement equipment, supporting stable performance without interference and controlled emission levels.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61010-2-101 – Safety Requirements for IVD Equipment\u003c\/strong\u003e\u003cbr\u003eSpecifies additional safety expectations for in vitro diagnostic (IVD) medical equipment, supporting safe handling in diagnostic and clinical workflows.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eISO 14971 – Medical Device Risk Management\u003c\/strong\u003e\u003cbr\u003eProvides a structured framework for identifying, evaluating, and controlling risks associated with medical devices, including IVD systems, throughout the product lifecycle.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eISO 13485 – Medical Device Quality Management System\u003c\/strong\u003e\u003cbr\u003eDefines quality management system requirements for medical device manufacturing, ensuring consistent design, production, and regulatory compliance processes.\u003c\/p\u003e\n\u003ch2\u003eDry Contactless Ultrasonicator – QualiUltra™ DCL Series Key Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSealed-tube, dry non-contact processing\u003c\/strong\u003e\u003cbr\u003eEnables sonication inside sealed tubes without direct probe interaction, supporting cleaner handling and reduced cross-sample interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSemiconductor-based temperature control system\u003c\/strong\u003e\u003cbr\u003eIntegrated cooling maintains stable low-temperature conditions during processing, helping preserve the integrity of temperature-sensitive biomolecules.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRapid pretreatment for time-critical workflows\u003c\/strong\u003e\u003cbr\u003eDesigned for fast sample processing, with effective preparation achievable in approximately two minutes for compatible sample types, supporting high-throughput environments.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eReduced aerosol and mist formation risk\u003c\/strong\u003e\u003cbr\u003eNon-contact energy transfer within sealed systems helps limit aerosol generation, supporting safer laboratory operation during disruption processes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompact and space-efficient design\u003c\/strong\u003e\u003cbr\u003eA small footprint allows flexible placement in limited or high-density laboratory setups without requiring extensive bench space.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCompatible with multiple downstream workflows\u003c\/strong\u003e\u003cbr\u003eProcessed samples are suitable for further steps such as nucleic acid amplification, probe-based detection, purification, and related analytical procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eUser-friendly operation with repeatable settings\u003c\/strong\u003e\u003cbr\u003eSimple button-based controls with an LCD interface, along with stored parameter sets, support consistent operation and reproducible results across repeated runs.\u003c\/p\u003e\n\u003ch2\u003eTheory and Method – QualiUltra™ DCL Series Dry Contactless Ultrasonicator\u003c\/h2\u003e\n\u003cp\u003eThe QualiUltra™ DCL Series operates using indirect ultrasonic energy transmission from a bottom-mounted ultrasound module into sealed sample tubes. This approach generates controlled mechanical forces through ultrasonic waves, enabling efficient cell disruption and membrane breakage without the need for probe immersion. By eliminating direct probe-to-sample contact, the system helps reduce contamination risk and simplifies routine laboratory handling.\u003c\/p\u003e\n\u003cp\u003eA typical workflow begins by loading 500–1000 µL of sample into a compatible 2.0 mL sealed ultrasound tube. The tube is then placed into the instrument chamber, where operational parameters such as ultrasonic power level and total processing time are selected, with timing adjustable within a 1–900 second range depending on sample requirements.\u003c\/p\u003e\n\u003cp\u003eDuring operation, an integrated semiconductor-based cooling system maintains a stable low-temperature environment, helping to protect temperature-sensitive biomolecules throughout the sonication process. After completion, the processed sample can be directly transferred to downstream applications such as nucleic acid amplification, hybridization assays, purification steps, or other analytical workflows without additional handling steps.\u003c\/p\u003e\n\u003ch2\u003eDry Contactless Ultrasonicator – QualiUltra™ DCL Series Technical Specification\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ DCL\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasonic frequency\u003c\/td\u003e\n\u003ctd\u003e20 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasonic power\u003c\/td\u003e\n\u003ctd\u003eMax 30 W, adjustable in 10 levels\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample throughput\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWorking volume\u003c\/td\u003e\n\u003ctd\u003e500–1000 µL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApplicable consumables\u003c\/td\u003e\n\u003ctd\u003e2.0 mL ultrasound sample tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTiming range\u003c\/td\u003e\n\u003ctd\u003e1–900 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature range\u003c\/td\u003e\n\u003ctd\u003e8–12°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature control method\u003c\/td\u003e\n\u003ctd\u003eSemiconductor \"parcel refrigeration\"\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eControl method\u003c\/td\u003e\n\u003ctd\u003eButton control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStored programs \/ data\u003c\/td\u003e\n\u003ctd\u003e99 sets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e200–240 V, 50–60 Hz (110V is also available)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall power\u003c\/td\u003e\n\u003ctd\u003e80 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating environment\u003c\/td\u003e\n\u003ctd\u003e15–30°C; RH ≤ 70%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e155 × 208 × 193 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.6 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52072264270135,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/dry-contactless-ultrasonicator1567370418.webp?v=1777593083"},{"product_id":"contact-free-ultrasonicator","title":"Contact Free Ultrasonicator","description":"\u003ch2\u003eContact Free Ultrasonicator – QualiUltra™ FC Series\u003c\/h2\u003e\n\u003cp\u003eThe QualiUltra™ FC Series Contact Free Ultrasonicator is engineered for rapid, non-contact processing of sealed microtubes. It delivers ultrasonic energy directly into samples without the need for a probe, helping minimize carryover risk and supporting cleaner, more controlled workflows. This system is optimized for fast sample pretreatment in trace analysis, on-site screening, and quick detection applications. Users can define sonication time, interval cycles, and total runtime to ensure consistent and repeatable processing across multiple runs.\u003c\/p\u003e\n\u003cp\u003eThe QualiUltra™ FC Series is a compact Contact Free Ultrasonicator built for efficient low-volume processing in standard 2 mL tubes. It removes common limitations associated with probe-based sonication, such as complex setup and direct sample contact. With adjustable intensity and programmable cycle settings, it allows precise control over each protocol while maintaining straightforward operation. This design supports contamination-aware sample preparation and improves workflow efficiency in routine laboratory environments.\u003c\/p\u003e\n\u003ch2\u003eContact Free Ultrasonicator – QualiUltra™ FC Series Applications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eRapid detection and field inspection workflows\u003c\/strong\u003e\u003cbr\u003eThis system is suited for fast sample pretreatment where quick turnaround is critical. It enables efficient processing of trace-level samples prior to downstream analytical or detection procedures, supporting time-sensitive screening workflows.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDisruption of microbial and cellular structures\u003c\/strong\u003e\u003cbr\u003eContact-free ultrasonic processing supports effective breakdown of cells, bacteria, viruses, spores, and related biological structures. This process helps release intracellular material required for further analysis and processing steps.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSupport for intracellular extraction workflows\u003c\/strong\u003e\u003cbr\u003eThe technology assists in isolating intracellular proteins, membrane proteins, nucleic acids, and other bioactive compounds. The sealed-tube format helps maintain clean handling conditions during sample preparation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePathogen-focused research applications\u003c\/strong\u003e\u003cbr\u003eThis platform is suitable for research workflows involving bacteria and viruses. The contact-free approach helps lower the chance of aerosol formation and reduces direct exposure during sample processing compared to open systems.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eSmall-volume formulation and preparation processes\u003c\/strong\u003e\u003cbr\u003eThe system is also suitable for low-volume applications such as liposome preparation, emulsification, and extraction procedures. Adjustable cycle settings allow controlled energy delivery for sensitive formulations and specialized protocols.\u003c\/p\u003e\n\u003ch3\u003eStandards Compliance\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61010-1\u003c\/strong\u003e\u003cbr\u003eDefines safety requirements for electrical equipment used in measurement, control, and laboratory environments, ensuring safe operation under intended conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61326-1\u003c\/strong\u003e\u003cbr\u003eSpecifies electromagnetic compatibility (EMC) requirements for laboratory and analytical equipment, supporting stable performance in standard lab settings without interference issues.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eISO 20427:2023\u003c\/strong\u003e\u003cbr\u003eProvides guidance for standardized ultrasonic dispersion procedures, supporting consistent method development and helping align experimental documentation across workflows.\u003c\/p\u003e\n\u003ch2\u003eContact Free Ultrasonicator – QualiUltra™ FC Series Key Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eContact-free sealed tube processing\u003c\/strong\u003e\u003cbr\u003eEnables ultrasonic treatment inside closed microtubes without direct probe contact, supporting cleaner handling and reduced cross-contamination risk.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOptimized for trace-level pretreatment\u003c\/strong\u003e\u003cbr\u003eDesigned for rapid processing of low-volume samples, making it suitable for fast detection workflows and field-based analytical applications.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProgrammable cycle control\u003c\/strong\u003e\u003cbr\u003eAllows users to define sonication duration, interval timing, and total run time, helping maintain consistent and repeatable processing conditions.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAdjustable power output\u003c\/strong\u003e\u003cbr\u003ePower settings can be fine-tuned to match different sample types and desired outcomes, enabling better control over energy delivery.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMultiple sample processing per run\u003c\/strong\u003e\u003cbr\u003eSupports batch handling of several tubes in a single session, improving workflow efficiency and throughput.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntuitive touchscreen interface\u003c\/strong\u003e\u003cbr\u003eA compact touchscreen control system simplifies setup and reduces operator training requirements while minimizing process variability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic tube positioning system\u003c\/strong\u003e\u003cbr\u003eAutomatic compression-based coupling ensures stable tube placement during operation, supporting uniform energy transfer and reliable results.\u003c\/p\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003eThis Ultrasonicator operates without direct probe insertion into the sample. Instead, ultrasonic energy is transmitted through the tube wall, generating mechanical effects within the sealed container that support effective mixing and disruption. This contact-free energy transfer helps maintain cleaner handling conditions while enabling consistent sample processing.\u003c\/p\u003e\n\u003cp\u003eThe system typically uses a cycle-based approach, combining an ultrasonic “on” phase with an “interval” phase that repeats until the defined total runtime is completed. This structured cycling helps control temperature build-up and improves reproducibility across multiple samples and runs.\u003c\/p\u003e\n\u003cp\u003eA standard method begins by transferring the sample into a compatible 2 mL tube and placing it into the designated holder. Users then configure key parameters such as power level, ultrasonic duration, interval timing, and total processing time via the touchscreen interface before initiating the run. Once processing is complete, the tube is removed and the sample can proceed to downstream workflows such as extraction, amplification, purification, or further analytical preparation depending on the protocol requirements.\u003c\/p\u003e\n\u003ch2\u003eContact Free Ultrasonicator – QualiUltra™ FC Series Technical Specification\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ FC 8020\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasonic power\u003c\/td\u003e\n\u003ctd\u003e50 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal time per run\u003c\/td\u003e\n\u003ctd\u003e120 s (30–600 s settable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUltrasonic time\u003c\/td\u003e\n\u003ctd\u003e1–99 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInterval time\u003c\/td\u003e\n\u003ctd\u003e1–99 s\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower setting\u003c\/td\u003e\n\u003ctd\u003e1–100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSamples per session\u003c\/td\u003e\n\u003ctd\u003e1–8 pcs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible tube types\u003c\/td\u003e\n\u003ctd\u003e2 mL EP tube; 2 mL freezing tube\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation mode\u003c\/td\u003e\n\u003ctd\u003e4.3-inch touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompression mode\u003c\/td\u003e\n\u003ctd\u003eAutomatic electric compression\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52072274919735,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/contact-free-ultrasonicator318660554.webp?v=1777593409"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/collections\/contactless-ultrasonicator1429897084.webp?v=1777592279","url":"https:\/\/qualitest.us\/collections\/contactless-ultrasonicator.oembed","provider":"Qualitest USA LC","version":"1.0","type":"link"}