{"product_id":"vertical-drain-discharge-capacity-tester-350-kpa","title":"Vertical Drain Discharge Capacity Tester (350 kPa)","description":"\u003ch2\u003e\u003cspan\u003eVertical Drain Discharge Capacity Tester (350 kPa) – QualiGTX™ DDCT V\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003eEvaluating how efficiently prefabricated vertical drains remove water from saturated soil requires testing under conditions that reflect the pressures encountered in actual ground improvement projects. The QualiGTX™ DDCT V is designed for this purpose, measuring longitudinal water flow through PVDs at confining pressures ranging from 10 to 350 kPa. It provides geotechnical laboratories, drainage board manufacturers, and ground improvement contractors with the measurements needed to assess whether a drain can deliver the hydraulic performance required by a consolidation design.\u003c\/p\u003e\n\u003cp\u003eThe testing process brings specimen preparation, hydraulic loading, and flow measurement together in one automated operation. Once the drain is secured, the apparatus establishes a constant hydraulic head and directs water through the specimen's drainage core. The discharged volume is measured over a controlled period, allowing the system to calculate discharge capacity without requiring manual collection and stopwatch measurements. Results are displayed on the touchscreen, and a test report is generated for printing or electronic transfer.\u003c\/p\u003e\n\u003cp\u003eMaintaining suitable water conditions is particularly important when measuring flow through narrow drainage channels. Air released from dissolved gases can form bubbles within the specimen, obstructing the flow passages and causing discharge capacity to appear lower than its actual value. To minimize this source of error, the DDCT V features an integrated de-aeration and thermostatic conditioning arrangement with a dissolved oxygen analyzer. Its 50 L stainless steel reservoir provides temperature-controlled water between 5 °C and 100 °C, maintaining the selected setting within ±0.5 °C. The analyzer also enables operators to check dissolved oxygen content before testing rather than relying on unverified water conditions.\u003c\/p\u003e\n\u003cp\u003eHydraulic gradient control is another important part of the measurement process. The industrial touchscreen computer manages specimen clamping, head positioning, timed volume collection, and final calculations. Operators enter the required gradient, and the system automatically adjusts the head difference, with a maximum available difference of 300 mm and gradient accuracy of 0.02. By coordinating these operations electronically, the instrument reduces variations associated with manual adjustments and timing. Laboratories can therefore assess individual band drain specimens under controlled conditions and maintain a documented record of every test.\u003c\/p\u003e\n\u003ch2\u003e\u003cspan\u003eVertical Drain Discharge Capacity Tester (350 kPa) – QualiGTX™ DDCT V Applications\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDischarge capacity testing helps determine whether drainage boards retain the required water-flow performance under the loading conditions associated with soft soil consolidation. The QualiGTX™ DDCT V supports this evaluation throughout product manufacturing, project qualification, independent testing, and geotechnical research.\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eSoft Soil Ground Improvement:\u003c\/span\u003e\u003cspan\u003e Determines whether prefabricated vertical drains provide the required drainage capacity before installation in projects involving compressible clay, including embankments, ports, and land reclamation developments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003ePVD and Band Drain Production:\u003c\/span\u003e\u003cspan\u003e Enables manufacturers to monitor drainage core channel dimensions and filter jacket performance, helping maintain consistent product quality between manufacturing lots.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eHighway and Railway Construction:\u003c\/span\u003e\u003cspan\u003e Evaluates drainage board performance against the requirements used in settlement acceleration designs for road and railway embankments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003ePort and Land Reclamation Projects:\u003c\/span\u003e\u003cspan\u003e Assesses vertical drains intended for marine clay consolidation, particularly where substantial surcharge loading subjects the drainage system to higher confining pressures.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eGeotechnical Research and Development:\u003c\/span\u003e\u003cspan\u003e Allows researchers to examine the effects of applied pressure, core deformation, filter clogging, and long-term creep on the remaining discharge capacity of drainage materials.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eIndependent Testing and Certification:\u003c\/span\u003e\u003cspan\u003e Provides third-party measurements for checking manufacturer-declared discharge capacity values and supporting compliance with tender specifications and contractual requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eGeotechnical Engineering and Design Validation:\u003c\/span\u003e\u003cspan\u003e Generates well resistance data used in consolidation calculations, engineering models, and settlement forecasts.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eVertical Drain Discharge Capacity Tester (350 kPa) – QualiGTX™ DDCT V Key Features\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eDesigned around the requirements of controlled PVD performance testing, the DDCT V combines mechanical loading, automated hydraulic regulation, conditioned water supply, and electronic data handling. Its principal features include:\u003c\/span\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eCentralized Touchscreen Operation:\u003c\/span\u003e\u003cspan\u003e A single industrial computer manages the complete testing sequence, including specimen positioning, clamping, hydraulic gradient settings, collection timing, and discharge capacity calculations. Technicians can operate the system without relying on separate measurement instruments.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eAutomated Specimen Securing:\u003c\/span\u003e\u003cspan\u003e The clamping mechanism holds the drainage specimen in position without manual bolting. This simplifies preparation and reduces differences in applied clamping force between operators.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eAdjustable Confining Pressure:\u003c\/span\u003e\u003cspan\u003e The 10–350 kPa operating range allows laboratories to investigate drainage performance under pressures associated with both relatively shallow embankments and deep reclamation fills.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eProgrammable Hydraulic Gradient:\u003c\/span\u003e\u003cspan\u003e The apparatus automatically establishes the required head difference based on the operator's input and maintains gradient accuracy to 0.02, helping control a key variable affecting discharge capacity measurements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eIntegrated Water De-Aeration and Temperature Conditioning:\u003c\/span\u003e\u003cspan\u003e Prepares the supply water by removing dissolved gases and maintaining a controlled temperature, reducing measurement disturbances caused by bubbles forming inside the drain channels.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eDissolved Oxygen Monitoring:\u003c\/span\u003e\u003cspan\u003e The built-in analyzer measures dissolved oxygen with 0.01 mg\/L resolution, allowing operators to verify water conditions before starting a test.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eConstant Hydraulic Head:\u003c\/span\u003e\u003cspan\u003e Maintains a stable water level during flow measurement so that changes in the water supply do not cause unwanted variations in the applied gradient.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eAutomated Flow Measurement:\u003c\/span\u003e\u003cspan\u003e Collects and measures discharged water while recording elapsed time. The system uses these measurements to calculate discharge capacity and generate the corresponding report.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e50 L Stainless Steel Reservoir:\u003c\/span\u003e\u003cspan\u003e Provides the conditioned water supply in a corrosion-resistant tank sized to support extended testing operations.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eHeating and Cooling Capability:\u003c\/span\u003e\u003cspan\u003e Covers temperatures from 5 °C to 100 °C. The system takes approximately 30 minutes to heat water from ambient temperature to boiling and approximately 90 minutes to cool it from boiling to 20 °C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eSelf-Regulating PID Temperature Management:\u003c\/span\u003e\u003cspan\u003e Uses self-tuning PID control to respond to changing thermal loads automatically and correct measurement deviation to 0.1 °C.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eDual Fluid Circulation Options:\u003c\/span\u003e\u003cspan\u003e Offers internal circulation within the reservoir and external circulation for supplying conditioned fluid to another vessel. These modes allow the bath to support both internal temperature regulation and external heating or cooling applications.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eAluminum Alloy Clamping Assembly:\u003c\/span\u003e\u003cspan\u003e Maintains the specimen's flat, parallel position under applied pressure while providing corrosion resistance during prolonged contact with water.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003e304 Stainless Steel Worktable Container:\u003c\/span\u003e\u003cspan\u003e Combines a stainless steel construction with an electrostatic powder-coated surface to provide a practical working area for wet laboratory conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eSilicone Sealing Components:\u003c\/span\u003e\u003cspan\u003e Corrosion-resistant silicone seals prevent water from escaping the specimen chamber during repeated pressure cycles, helping ensure that collected water represents actual flow through the drainage specimen.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eAir-Cooled Refrigeration Arrangement:\u003c\/span\u003e\u003cspan\u003e Uses an outdoor condensing unit to reduce noise and energy consumption within the laboratory.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cdiv\u003e\n\u003cdiv\u003e\n\u003cp\u003e\u003cspan\u003eElectronic Reports and Data Export:\u003c\/span\u003e\u003cspan\u003e Generates printable test documentation and exportable data files, supporting internal quality records, customer reporting, and audit requirements.\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003cspan\u003eTheory and Method\u003c\/span\u003e\u003c\/h2\u003e\n\u003cp\u003e\u003cspan\u003eThe purpose of a vertical drain discharge capacity test is to establish how much water a drainage product can convey along its length under a specified hydraulic gradient. This property is represented by \u003c\/span\u003e\u003cspan\u003e\u003cspan data-math-source=\"q_w\" data-math-display=\"false\"\u003e\\(q_w\\)\u003c\/span\u003e\u003c\/span\u003e\u003cspan\u003e and provides designers with information about the drain's ability to transport pore water during soil consolidation.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe measurement is based on Darcy's law. Rather than allowing the hydraulic conditions to vary throughout the test, the apparatus maintains a defined gradient and measures the volume of water passing through the drain over a known period. The collected volume and elapsed time establish the flow rate, which is then divided by the applied hydraulic gradient to calculate qw\u003c\/span\u003e\u003cspan\u003e. The method assumes laminar flow; therefore, gradient settings must remain within limits that prevent turbulence from affecting the measured capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eHowever, the drainage capacity measured under no load does not necessarily represent performance after installation. In the field, surrounding soil applies lateral pressure to the vertical drain. Under an embankment, for example, increasing soil stress can compress the plastic core, reduce the dimensions of its internal flow channels, and force the filter jacket against the grooves. These changes restrict the available space for water movement and can reduce the drain's effective discharge capacity.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTo evaluate this pressure-dependent behavior, the DDCT V applies confining loads between 10 and 350 kPa while maintaining water flow through the specimen. Measurements at different loading levels reveal how much drainage capacity is retained as pressure increases. This information helps engineers determine whether a selected drain can maintain adequate hydraulic performance under anticipated field stresses and whether its well resistance remains within the limits assumed by the consolidation design.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eWater quality must also be controlled because the measurement depends on accurately determining the volume that passes through the specimen. Dissolved gases can escape from the water when it enters the confined drainage channels, forming bubbles that occupy part of the available flow area. The resulting obstruction reduces the measured water volume, potentially indicating a loss of drainage capacity even when the drain itself has not experienced an equivalent reduction in performance.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eThe DDCT V addresses this problem through its water conditioning arrangement. The reservoir de-aerates the supply before testing, while the dissolved oxygen analyzer provides a measurement of the water's oxygen content so operators can verify its condition before proceeding.\u003c\/span\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cspan\u003eTemperature is another variable that must remain consistent between tests. As water temperature rises, its viscosity decreases, changing the way it moves through the drainage channels. Consequently, temperature differences can influence measured flow rates even when the specimens have similar properties. The thermostatic system maintains the selected temperature within ±0.5 °C, reducing this source of variation and supporting meaningful comparisons between specimens tested under controlled conditions.\u003c\/span\u003e\u003c\/p\u003e\n\u003ch2\u003eVertical Drain Discharge Capacity Tester (350 kPa) - QualiGTX™ DDCT V Technical Specifications\u003c\/h2\u003e\n\u003ctable class=\"table table-style-align-center\" align=\"center\" border=\"1\" cellspacing=\"0\" cellpadding=\"0\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eConfining Pressure Range\u003c\/td\u003e\n\u003ctd\u003e10 to 350 kPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Water Head Difference\u003c\/td\u003e\n\u003ctd\u003e300 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecimen Width\u003c\/td\u003e\n\u003ctd\u003e100 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Specimen Thickness\u003c\/td\u003e\n\u003ctd\u003e50 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEffective Specimen Length\u003c\/td\u003e\n\u003ctd\u003e400 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydraulic Gradient Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Control Range\u003c\/td\u003e\n\u003ctd\u003e5 °C to 100 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Control Mode\u003c\/td\u003e\n\u003ctd\u003eHeating and refrigeration, self-tuning PID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Analyzer Range\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mg\/L; 0 to 200 %; 0 to 400 hPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Analyzer Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5 % FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Analyzer Repeatability\u003c\/td\u003e\n\u003ctd\u003e±0.5 % FS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Analyzer Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 0.1 %; 1 hPa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Supply Tank Capacity\u003c\/td\u003e\n\u003ctd\u003e50 L, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Capacity\u003c\/td\u003e\n\u003ctd\u003e13,000 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Method\u003c\/td\u003e\n\u003ctd\u003eOutdoor air-cooled condensing unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompressor Power\u003c\/td\u003e\n\u003ctd\u003e1.1 kW (1.5 hp)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCirculation Modes\u003c\/td\u003e\n\u003ctd\u003eInternal and external\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInternal Circulation Pump Power\u003c\/td\u003e\n\u003ctd\u003e100 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExternal Circulation Pump Power\u003c\/td\u003e\n\u003ctd\u003e100 W, adjustable flow\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCirculation Pump Flow Rate\u003c\/td\u003e\n\u003ctd\u003e45 L\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeating Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 30 min, ambient to boiling\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCooling Time\u003c\/td\u003e\n\u003ctd\u003eApproximately 90 min, boiling to 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Conditioning System Power Supply\u003c\/td\u003e\n\u003ctd\u003e380 V \/ 50 Hz, 12 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Draw During Testing\u003c\/td\u003e\n\u003ctd\u003e1 kW\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOverall Dimensions (W × D × H)\u003c\/td\u003e\n\u003ctd\u003e1,380 × 780 × 1,870 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNet Weight\u003c\/td\u003e\n\u003ctd\u003e160 kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":53602345419063,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/vertical-drain-discharge-capacit.webp?v=1794470060","url":"https:\/\/qualitest.us\/ar\/products\/vertical-drain-discharge-capacity-tester-350-kpa","provider":"Qualitest USA LC","version":"1.0","type":"link"}