{"product_id":"portable-ultrasonicator","title":"Portable Ultrasonicator","description":"\u003ch2\u003ePortable Ultrasonicator – QualiUltra™ Port Series\u003c\/h2\u003e\n\u003cp\u003eThe QualiUltra™ Port Series Portable Ultrasonicator provides probe-type sonication in a compact, space-saving design, ideal for small-volume sample preparation. It supports a wide range of applications, including emulsification, dispersion, homogenization, extraction, degassing, cleaning, and nanomaterial processing—making it a practical alternative when a full bench-top system is unnecessary.\u003c\/p\u003e\n\u003cp\u003eThis series includes two models: the QualiUltra™ Port 250 for standard laboratory workflows and the QualiUltra™ Port 250S with battery support for field and mobile operations. A 4.3-inch touchscreen interface allows consistent parameter control, helping maintain repeatable results across different users.\u003c\/p\u003e\n\u003cp\u003eUsing ultrasonic cavitation at the probe tip, the system generates strong shear forces and efficient micro-mixing within liquid samples. This action enhances cell disruption and breaks down particle clusters effectively. Pulse mode operation assists in controlling temperature rise, while adjustable power output enables precise energy control for both sensitive biomolecules and more demanding dispersions.\u003c\/p\u003e\n\u003ch2\u003ePortable Ultrasonicator – QualiUltra™ Port Series Applications\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSmall-Volume Cell Disruption and Lysis\u003c\/strong\u003e\u003cbr\u003eProbe-based sonication enables efficient disruption of cells and microorganisms in microtubes and small vessels, supporting the release of intracellular components for downstream analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEmulsification and Homogenization\u003c\/strong\u003e\u003cbr\u003eUltrasonic energy enhances microscale mixing, resulting in stable emulsions and uniform sample consistency. Ideal for formulation testing and rapid laboratory trials.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNanomaterial Dispersion and Deagglomeration\u003c\/strong\u003e\u003cbr\u003eCavitation-driven shear forces break apart soft agglomerates and improve dispersion uniformity, supporting consistent treatment across multiple samples in comparative studies.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eExtraction and Sample Pretreatment\u003c\/strong\u003e\u003cbr\u003eUltrasound accelerates solvent interaction and mass transfer in small volumes, reducing preparation time for routine workflows and screening processes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eField and On-Site Sample Preparation\u003c\/strong\u003e\u003cbr\u003eThe QualiUltra™ Port 250S features built-in battery support for mobile use, allowing sample preparation directly at collection sites or within vehicle-based lab setups.\u003c\/p\u003e\n\u003ch3\u003eStandards\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61010-1\u003c\/strong\u003e\u003cbr\u003eDefines safety requirements for electrical equipment used in measurement, control, and laboratory environments, supporting safe operation and user protection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIEC 61326-1\u003c\/strong\u003e\u003cbr\u003eSpecifies electromagnetic compatibility (EMC) requirements to ensure reliable performance of laboratory and measurement equipment in environments with electrical interference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eISO 20427:2023\u003c\/strong\u003e\u003cbr\u003eOutlines standardized dispersion procedures, including the use of ultrasonic devices, to support consistent and well-documented sample preparation practices.\u003c\/p\u003e\n\u003ch2\u003ePortable Ultrasonicator – QualiUltra™ Port Series Key Features\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003ePortable, Small-Volume Sonication\u003c\/strong\u003e\u003cbr\u003eBuilt for micro-volume to low-milliliter processing, enabling fast and efficient sample preparation without requiring a large benchtop system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFlexible Operation Modes\u003c\/strong\u003e\u003cbr\u003eAutomatic mode supports consistent, repeatable workflows, while manual control—paired with an optional foot switch—gives users direct, real-time handling during processing.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery-Supported Mobility\u003c\/strong\u003e\u003cbr\u003eThe QualiUltra™ Port 250S features a battery-powered design, suitable for field sampling, on-site testing, and vehicle-based lab setups.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWide Frequency Tracking Range\u003c\/strong\u003e\u003cbr\u003eDesigned to maintain stable performance across varying sample loads and conditions, supporting reliable sonication results.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTouchscreen Interface for Consistency\u003c\/strong\u003e\u003cbr\u003eA 4.3-inch touch display allows easy setup and uniform control of time and output parameters across different operators.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePrecision Probe Tip\u003c\/strong\u003e\u003cbr\u003eA 3 mm probe is ideal for small tubes and limited sample volumes, offering better control during delicate procedures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eOver-Temperature Protection\u003c\/strong\u003e\u003cbr\u003eIntegrated temperature monitoring with alarm support enhances operational safety during routine use.\u003c\/p\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003eThe Portable Ultrasonicator converts electrical energy into high-frequency mechanical vibrations at the probe tip. These vibrations generate alternating pressure waves in the liquid, leading to cavitation. As microscopic bubbles form and collapse, they create localized shear forces that support cell disruption, enhance mixing, and improve particle dispersion. Pulse operation is commonly used to help manage heat buildup during extended processing.\u003c\/p\u003e\n\u003cp\u003eA typical workflow begins by selecting the appropriate probe and immersing it into the sample. The user then sets the desired power level and processing time. Many protocols rely on short pulse cycles with rest intervals, followed by temperature checks before repeating if required. After completion, the probe is rinsed, and the sample proceeds to extraction, analysis, or formulation stages.\u003c\/p\u003e\n\u003ch2\u003ePortable Ultrasonicator – QualiUltra™ Port Series Technical Specification\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ Port 250\u003c\/th\u003e\n\u003cth\u003eQualiUltra™ Port 250S\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax output power\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e250 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e19–25 kHz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTiming\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e0.1–99 min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe tip\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample volume range\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e100 µL–10 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperation modes\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003eAutomatic; manual (optional foot switch)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd colspan=\"2\"\u003e4.3-inch touch screen\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimension (L × W × H)\u003c\/td\u003e\n\u003ctd\u003e270 × 245 × 116 mm\u003c\/td\u003e\n\u003ctd\u003e122 × 252 × 200 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage\u003c\/td\u003e\n\u003ctd\u003e220 V \/ 50 Hz (110V is also available)\u003c\/td\u003e\n\u003ctd\u003e2A \/ 12 V charger; built-in lithium battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52070998311223,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/portable-ultrasonicator1550144460.webp?v=1777562846","url":"https:\/\/qualitest.us\/ar\/products\/portable-ultrasonicator","provider":"Qualitest USA LC","version":"1.0","type":"link"}