{"product_id":"advanced-cooling-and-heating-chiller","title":"Advanced Cooling and Heating Chiller","description":"\u003ch2 data-section-id=\"fc9a1v\" data-start=\"0\" data-end=\"62\"\u003eAdvanced Cooling and Heating Chiller – QualiCHC™ Adv Series\u003c\/h2\u003e\n\u003ch3 data-section-id=\"194aou5\" data-start=\"64\" data-end=\"120\"\u003eAdvanced Cooling and Heating Chiller (50°C to 300°C)\u003c\/h3\u003e\n\u003cp data-start=\"122\" data-end=\"362\"\u003eQualiCHC™ Adv Series is an advanced cooling and heating chiller engineered to provide precise, repeatable temperature control for circulating heat transfer fluid through external reactors, jacketed vessels, process coils, and test fixtures.\u003c\/p\u003e\n\u003cp data-start=\"364\" data-end=\"594\"\u003eThis Process Thermostat integrates refrigeration, electric heating, and a high-performance recirculation pump into a compact system, providing reliable heating and cooling across a broad operating range from 50°C to 300°C.\u003c\/p\u003e\n\u003cp data-start=\"596\" data-end=\"989\"\u003eDesigned for laboratory, pilot plant, and industrial process applications, the QualiCHC™ Adv Series delivers accurate temperature regulation with greater stability than conventional water cooling or ice bath methods. The system supports both internal reservoir temperature control and external closed-loop circulation, offering flexibility for a wide range of temperature-controlled processes.\u003c\/p\u003e\n\u003cp data-start=\"991\" data-end=\"1388\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eBuilt for continuous operation, this Process Thermostat maintains consistent process temperatures during extended testing and production cycles. It is well suited for holding stable setpoints, executing programmed temperature ramps or step changes, and compensating for heat generated by exothermic reactions or operating equipment, helping maintain reliable and repeatable process conditions.\u003c\/p\u003e\n\u003ch2 data-section-id=\"ic0fii\" data-start=\"0\" data-end=\"75\" class=\"PDq2pG_selectionAnchorContainer\"\u003eAdvanced Cooling and Heating Chiller – QualiCHC™ Adv Series Applications\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h2\u003e\n\u003cul data-start=\"77\" data-end=\"1065\" data-is-last-node=\"\" data-is-only-node=\"\"\u003e\n\u003cli data-section-id=\"tz87k6\" data-start=\"77\" data-end=\"287\"\u003eJacketed Reactor Temperature Control: Circulates heat transfer fluid through reactor jackets to maintain precise process temperatures during synthesis, crystallization, polymerization, and neutralization.\u003c\/li\u003e\n\u003cli data-section-id=\"14qik3w\" data-start=\"288\" data-end=\"463\"\u003eSample and Material Conditioning: Maintains stable temperatures for samples and materials before testing, helping improve measurement consistency and repeatable results.\u003c\/li\u003e\n\u003cli data-section-id=\"vzam6o\" data-start=\"464\" data-end=\"632\"\u003eCondenser and Heat Exchanger Cooling: Delivers controlled cooling fluid for laboratory condensers, compact heat exchangers, and closed-loop recirculation systems.\u003c\/li\u003e\n\u003cli data-section-id=\"1rdbfi5\" data-start=\"633\" data-end=\"835\"\u003eEquipment and Test Fixture Temperature Control: Provides reliable cooling and heating for thermal plates, process coils, custom fixtures, and research equipment used in development and validation.\u003c\/li\u003e\n\u003cli data-section-id=\"1jehwdn\" data-start=\"836\" data-end=\"1065\" data-is-last-node=\"\"\u003eLaboratory Process Thermostating: Replaces inconsistent tap water or manual cooling methods with a precise, monitored Process Thermostat for dependable temperature control across laboratory and pilot-scale applications.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eStandards\u003c\/h2\u003e\n\u003cp\u003eQualiCHC™ Adv Series is designed in accordance with internationally recognized electrical safety and electromagnetic compatibility requirements for laboratory and industrial temperature control equipment.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003eIEC 61010-1 – Safety requirements for electrical equipment used in measurement, control, and laboratory applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eUL 61010-1 – U.S. electrical safety standard harmonized with the IEC 61010-1 framework.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIEC 61326-1 – Electromagnetic compatibility (EMC) requirements for electrical equipment used in measurement, control, and laboratory environments.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eAdvanced Cooling and Heating Chiller – QualiCHC™ Adv Series Key Features\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cp\u003e50°C to 300°C Operating Range: Supports precise heating and cooling across a broad temperature range for laboratory, pilot-scale, and industrial process applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eAccurate Temperature Stability: Delivers consistent temperature regulation for repeatable testing, process development, and production workflows.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated Heating, Cooling, and Circulation: Combines refrigeration, electric heating, and a recirculation pump in a compact system for efficient closed-loop temperature control.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eInternal Reservoir and External Circulation: Supports both internal bath applications and external process loops, including reactors, heat exchangers, and jacketed vessels.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eConfigurable Flow Performance: Multiple pump flow rates and pressure options are available to accommodate different piping layouts, circulation distances, and process requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eScalable System Configurations: Available in a range of capacities and reservoir sizes to support applications from research laboratories to higher-capacity process systems.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cp\u003eIntegrated Equipment Protection: Includes compressor protection features such as over-temperature and overload safeguards to enhance operational reliability and extend system service life.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eTheory and Method\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/thermostat-11-48397420.webp?v=1784110524\" alt=\"Advanced Cooling and Heating Chiller\"\u003e\u003c\/p\u003e\n\u003ch3 data-section-id=\"100y8vp\" data-start=\"22\" data-end=\"56\" class=\"PDq2pG_selectionAnchorContainer\"\u003eHow a Process Thermostat Works\u003cspan aria-hidden=\"true\" class=\"PDq2pG_selectionAnchor\"\u003e\u003c\/span\u003e\n\u003c\/h3\u003e\n\u003cp data-start=\"58\" data-end=\"561\"\u003eA Process Thermostat regulates the temperature of a circulating heat transfer fluid through an integrated heating and cooling system. The refrigeration circuit removes heat to lower fluid temperature, while electric heaters provide controlled heating to reach higher setpoints. A recirculation pump continuously moves the conditioned fluid through the internal reservoir or an external process loop connected to reactors, jacketed vessels, heat exchangers, or other temperature-controlled equipment.\u003c\/p\u003e\n\u003ch3 data-section-id=\"x0tq66\" data-start=\"563\" data-end=\"581\"\u003eControl Method\u003c\/h3\u003e\n\u003cp data-start=\"583\" data-end=\"1131\" data-is-last-node=\"\" data-is-only-node=\"\"\u003eA digital PID controller continuously monitors temperature using feedback from the reservoir and\/or circulation line, automatically adjusting heating and cooling output to maintain the selected setpoint. This closed-loop control method delivers stable temperature regulation, minimizes fluctuations, and improves repeatability during continuous operation. System response depends on factors such as circulation flow rate, thermal load, and external plumbing configuration, allowing the process to reach and maintain thermal equilibrium efficiently.\u003c\/p\u003e\n\u003ch2\u003eAdvanced Cooling and Heating Chiller – QualiCHC™ Adv Series Technical Specification\u003c\/h2\u003e\n\u003ctable class=\"table\" border=\"1\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003eTemp Range (°C)\u003c\/th\u003e\n\u003cth\u003eVolume (L)\u003c\/th\u003e\n\u003cth\u003eTemp Stability (°C)\u003c\/th\u003e\n\u003cth\u003ePump Flow (L\/min)\u003c\/th\u003e\n\u003cth\u003ePump Pressure (bar)\u003c\/th\u003e\n\u003cth\u003eCooling Capacity @25°C (kW)\u003c\/th\u003e\n\u003cth\u003eHeating Power (kW)\u003c\/th\u003e\n\u003cth\u003eTotal Power (kW\/h)\u003c\/th\u003e\n\u003cth\u003eDimensions L×W×H (mm)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiCHC™ Adv 5A\u003c\/td\u003e\n\u003ctd\u003e-5 to 100\u003c\/td\u003e\n\u003ctd rowspan=\"5\"\u003e6\u003c\/td\u003e\n\u003ctd rowspan=\"15\"\u003e±0.1\u003c\/td\u003e\n\u003ctd\u003e0–15\u003c\/td\u003e\n\u003ctd rowspan=\"15\"\u003e0.45\u003c\/td\u003e\n\u003ctd\u003e0.42\u003c\/td\u003e\n\u003ctd rowspan=\"14\"\u003e1.0\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003ctd\u003e390 × 340 × 652\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiCHC™ Adv 10A\u003c\/td\u003e\n\u003ctd\u003e-10 to 100\u003c\/td\u003e\n\u003ctd\u003e0–15\u003c\/td\u003e\n\u003ctd\u003e0.32\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003ctd\u003e390 × 340 × 652\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiCHC™ Adv 20A\u003c\/td\u003e\n\u003ctd\u003e-20 to 100\u003c\/td\u003e\n\u003ctd\u003e0–15\u003c\/td\u003e\n\u003ctd\u003e0.42\u003c\/td\u003e\n\u003ctd\u003e1.4\u003c\/td\u003e\n\u003ctd\u003e390 × 340 × 652\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiCHC™ Adv 30A\u003c\/td\u003e\n\u003ctd\u003e-30 to 100\u003c\/td\u003e\n\u003ctd\u003e0–15\u003c\/td\u003e\n\u003ctd\u003e0.42\u003c\/td\u003e\n\u003ctd\u003e1.6\u003c\/td\u003e\n\u003ctd\u003e455 × 388 × 845\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiCHC™ Adv 40A\u003c\/td\u003e\n\u003ctd\u003e-40 to 100\u003c\/td\u003e\n\u003ctd\u003e0–15\u003c\/td\u003e\n\u003ctd\u003e0.48\u003c\/td\u003e\n\u003ctd\u003e1.9\u003c\/td\u003e\n\u003ctd\u003e455 × 388 × 845\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiCHC™ Adv 5B\u003c\/td\u003e\n\u003ctd\u003e-5 to 100\u003c\/td\u003e\n\u003ctd rowspan=\"6\"\u003e10\u003c\/td\u003e\n\u003ctd\u003e0–15\u003c\/td\u003e\n\u003ctd\u003e0.52\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003ctd\u003e395 × 336 × 715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiCHC™ Adv 10B\u003c\/td\u003e\n\u003ctd\u003e-10 to 100\u003c\/td\u003e\n\u003ctd\u003e0–15\u003c\/td\u003e\n\u003ctd\u003e0.42\u003c\/td\u003e\n\u003ctd\u003e1.3\u003c\/td\u003e\n\u003ctd\u003e395 × 336 × 715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiCHC™ Adv 20B\u003c\/td\u003e\n\u003ctd\u003e-20 to 100\u003c\/td\u003e\n\u003ctd\u003e0–15\u003c\/td\u003e\n\u003ctd\u003e0.62\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e395 × 336 × 715\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiCHC™ Adv 30B\u003c\/td\u003e\n\u003ctd\u003e-30 to 100\u003c\/td\u003e\n\u003ctd\u003e0–15\u003c\/td\u003e\n\u003ctd\u003e0.54\u003c\/td\u003e\n\u003ctd\u003e1.5\u003c\/td\u003e\n\u003ctd\u003e455 × 388 × 845\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiCHC™ Adv 40B\u003c\/td\u003e\n\u003ctd\u003e-40 to 100\u003c\/td\u003e\n\u003ctd\u003e0–15\u003c\/td\u003e\n\u003ctd\u003e0.46\u003c\/td\u003e\n\u003ctd\u003e1.9\u003c\/td\u003e\n\u003ctd\u003e455 × 388 × 845\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiCHC™ Adv 20C\u003c\/td\u003e\n\u003ctd\u003e-20 to 100\u003c\/td\u003e\n\u003ctd\u003e0–15\u003c\/td\u003e\n\u003ctd\u003e0.62\u003c\/td\u003e\n\u003ctd\u003e1.4\u003c\/td\u003e\n\u003ctd\u003e725 × 440 × 555\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiCHC™ Adv 35A\u003c\/td\u003e\n\u003ctd\u003e-35 to 100\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e0–15\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003ctd\u003e1.8\u003c\/td\u003e\n\u003ctd\u003e725 × 440 × 555\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiCHC™ Adv 35B\u003c\/td\u003e\n\u003ctd\u003e-35 to 100\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003ctd\u003e0–15\u003c\/td\u003e\n\u003ctd\u003e0.75\u003c\/td\u003e\n\u003ctd\u003e1.8\u003c\/td\u003e\n\u003ctd\u003e725 × 440 × 555\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiCHC™ Adv 5C\u003c\/td\u003e\n\u003ctd\u003e-5 to 100\u003c\/td\u003e\n\u003ctd\u003e7\u003c\/td\u003e\n\u003ctd\u003e0–15\u003c\/td\u003e\n\u003ctd\u003e0.52\u003c\/td\u003e\n\u003ctd\u003e1.4\u003c\/td\u003e\n\u003ctd\u003e725 × 440 × 555\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQualiCHC™ Adv 5D\u003c\/td\u003e\n\u003ctd\u003e-5 to 100\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e0–15\u003c\/td\u003e\n\u003ctd\u003e0.76\u003c\/td\u003e\n\u003ctd\u003e1.55\u003c\/td\u003e\n\u003ctd\u003e2.1\u003c\/td\u003e\n\u003ctd\u003e455 × 388 × 845\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Qualitest USA LC","offers":[{"title":"Default Title","offer_id":52669289038135,"sku":null,"price":100.0,"currency_code":"USD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0786\/1859\/1543\/files\/advanced-cooling-and-heating-chiller178587122.webp?v=1784110624","url":"https:\/\/qualitest.us\/ar\/products\/advanced-cooling-and-heating-chiller","provider":"Qualitest USA LC","version":"1.0","type":"link"}